Professional Documents
Culture Documents
MULTi-V
Flow rates up to :
140 m3/h
Head up to :
240 m
Max. discharge pressure :
16 & 25 bar
Max. suction pressure :
10 bar
Temperature range :
15 + 120*C
Max. ambient temperature :
+ 40C
DN of ports :
25 100
APPLICATIONS
240
Hm
MULTi-V
Qm3/h
140
ADVANTAGES
Stainless steel hydraulic unit : anticorrosion safety and increased pump
lifetime.
Oversized (lantern) bearing for longer
motor bearing life; eliminates axial and
other adjustments of moving parts.
Tungsten carbide intermediate bearing
to control and eliminate vibration and
stabilize the rotor with a large number
of stages.
Thick impeller sealing rings between
stages for insensitivity to thermal expansion and elimination of risk of seizing up.
O ptimal reliability: high-efficiency
impeller profiles limit the number of
stages, the sizes of the shafts, and axial
thrusts.
Standardized mechanical seal, can be
used up to +120C without maintenance.
Easy to install: In-Line ports.
M ULTi-V PN16
oval flanges
M
ULTi-V PN25
Victaulic union
M ULTi-V 1800 PN 25
All 316L stainless steel
hydraulic parts
Mechanical
cartridge Seal
N.T. No 141-7/ENG. - d. 5/09-06
MULTi-V
DESIGN
MULTi-V CONSTRUCTION
Hydraulic part
-Centrifugal.
-Multistage, from 2 to 24 stages.
-Vertical axis, suction and IN-LINE discharge
ports at bottom.
-Casing for PN 16 and PN25.
-Bottom guide bearing above second stage
for 1 to 60 m3/h versions (above 1st stage
on 2- and 3-stage models).
-Shaft sealing by standardized mechanical
seal.
-H ydraulics and casing assembled by tie
rods.
Motor
-Standard ventilated.
-W ith flange and shaft end as per IEC
standard.
-Link to pump by coupling with guards.
Rotation speed :
Winding 4kW 3-ph :
> 4kW 3-ph :
Frequency :
Insulating category :
Protection index :
2 pole motor
STANDARD CONSTRUCTION
Main part
liquids
models
Material
non-aggressive aggressive
all
except 80/100
36C/60C
Suc.-Discharge casing EN GJL 250
Inox 316L
cast iron steel cast iron steel
Motor support bearing
EN GJL 250 cast iron steel
Impellers
304 stainless steel 316L stainless steel
Stages (casings)
304 SS
316L SS
Outside jacket tube
304 SS
316L SS
Pump shaft
304 SS
316L SS
Intermediate bearing
Carbure de Tungstne
Mechanical seal
Carbure Si/Carbone
O-rings
EPDM (120)
Viton (90)
Plugs
316L SS
316L SS
NB: 316L stainless steel (X2Cr Ni Mo 17.12.2) is a recommended material which is highly resistant to corrosion.
Transport of clean, clear liquids, containing no fibre and little
sand/silica (maximum concentration 40g/m3).
* AISI 304 stainless steel. The MULTi-V 80/100/36C/60C
models are fitted with an AISI 431 stainless steel pump shaft.
Rigid coupling
with safety protector
Filling plug Draining valve
Priming/draining plug
MULTi-V
IDENTIFICATION
MULTI-V10004/2N-OGE-T/2/6/OEM/XX/B
Pump family
Version index
Number of impellers
Nothing = 50 hz
6 = 60 hz
Number of pole
M = Single-phase
T = Three-phase : 50Hz - 230/400V
60Hz - 220 to 255 /
380 to 440V
T4 = Three-phase : 50Hz - 400V
60Hz - 380 to 440V
nothing = no motor
CONFIGURATION OF SERIES
SERIE
MULTI-V 100
MULTI-V 200
MULTi-V 400
MULTi-V 800
MULTi-V 1600
MULTi-V 1800
MULTi-V 3600
MULTi-V 6000
MULTi-V 8000
MULTi-V 100.00
motor 50 Hz
2 pole
4 pole
--
--
--
--
--
--
----
--
--
----
--
--
----
--
----
--
----
--
----
--
--
--
---
number of stages
oval G1
round DN 25
oval G1
round DN 25
Victaulic 11/4
oval G11/4
round DN 32
round DN 32
Victaulic 11/4
oval G11/2
round DN 40
round DN 40
Victaulic 2
oval G2
round DN 50
round DN 50
round DN 50 (65)
round DN 50 (65)
round DN 50 (65)
round DN 65 (80)
round DN 65 (80)
round DN 65 (80)
round DN 80 (80)
round DN 80 (80)
round DN 80 (80)
round DN 100 (100)
round DN 100 (100)
round DN 100 (100)
round DN 100 (100)
2 14
2 24
2 12
2 20
2 20
2 12
2 19
10-14-20
2 19
2 12
2 19
10-14-20
2 19
2 11
2 11
6-9-12
28
2 14
9-12-16
27
2 12
7-10-12
27
39
59
15
17
14
15
MULTi-V
2 pole motor
10
20
30
40
50
100
200
Imp.gpm
Hm
MULTi-V
Hft
50hz
800
240
220
700
200
600
180
160
500
140
400
120
MULTi-V
1800
100
300
80
MULTi-V MULTi-V
8000
10000
MULTi-V
3600
60
200
MULTi-V
100
MULTi-V
200
MULTi-V
400
MULTi-V
800
MULTi-V
1600
40
MULTi-V
6000
100
20
30
0,5
3
40
50
8 9 10
20
100
1
200
2
300
4
30
400
40
500
50
60
1000
10
15
QI/min
20
30
QI/s
MULTi-V
HYDRAULIC SELECTION CHARTS - MULTi-V | 4 PoLE - 50 Hz
0
10
20
30
40
50
100
Hm
Imp.gpm
Hft
MULTi-V
50hz
200
60
55
180
50
160
45
140
40
120
35
MULTi-V
400
MULTi-V
800
MULTi-V
1800
MULTi-V
3600
100
30
25
80
20
60
MULTi-V
6000
MULTi-V
1600
15
40
10
20
30
0,5
3
40
50
9 10
20
100
1
200
2
300
4
400
30
Qm3/h
500
QI/min
QI/s
MULTi-V
SECTIONAL VIEW - MULTi-V 1 - 2 - 4
MULTi-V 1/2/4
11/4 - PN16
Part list
1111 - Pump casing
1150 - Stage housing with return channel
1154 - Stage centering device
1160 - Stage housing without return channel
9902D
1720 - Semelle de fixation pompe
9902C
2110 - Pump shaft
9946C
2250 - Impeller
9923B
2410 - Impeller spacer
6571
2460 A - Shaft jacket spacer
2460 C - Mechanical seal keeper ring
9946B
2460 D - Rondelle intermdiaire
2520 - Thrust ring
2911 - Bottom shaft end washer
3011 - Lantern ball bearing
3044 - Stage casing with intermediate bearing
3160 - Motor support bearing
3400 - Shaft jacket
4213 - Stationary ring holder
4220 - Rotary part | Mechanical
4240 - Stationary ring | seal
4610 A - O-ring (filling plug)
4610 B - O-ring (outer jacket tube)
| (bouchon de vidange
4610 C - O-ring
| et damorage)
4610 D - O-ring
6515 - Drain and priming plug
6521 - Filling and venting plug
6545 A - Circlip (lantern bearing)
6545 B - Half keeper (thrust ring)
6546 - Circlip (lantern bearing)
6571 - Tirant dassemblage
7212 - Coupling
7450 - Coupling guard
8010 - Flanged electric motor
9130 - Outer ealing jacket tube
9902 A - Top shaft end screw
9902 B - Bottom shaft end screw
9902 C - Vis de fixation accouplement
9902 D - Vis de fixation moteur
9906 E - Motor fixing screw
9923 B - Ecrou de tirant dassemblage
9923 E - Ecrou H. fixation moteur
9942 - Fan washer under screw 9902 B
9946 A - Washer under screw 9902 A
9946 B - Rondelle sous crou 9923 B
9946 C - Washer under screw 9902 C
8010
6521B
6521A
4610A
DN32 - PN25
6545B
4220
2520
4213
2410
9130
4610B
1154
1150
2250
2460D
2460A
3044
1160
4610B
3400
2460A
05
1111
MULTi-V 1/2
MULTi-V 4
6546
3011
9902A
9946A
7212
2110
4240
6545A
MULTi-V 1/2
DN25 - PN25
1720
9942
9902B
MULTi-V
SECTIONAL VIEW - MULTi-V 8
MULTi-V
8
1/2
1
- PN16
6546
8010
3011
9902A
6545A
9946A
2110
9902D
9902C
9946C
9923B
6571
9946B
2460C
4240
6545B
4213
4610B
2520
4610A
2410
1150
4220
1154
2250
9130
2460A
3400
2460A
3044
2911B
9942
9902B
1160
4610B
1720
1111
4610F
MULTi-V 8
DN40 - PN25
MULTi-V 8
2"-PN25 - VICTAULIC
MULTi-V
SECTIONAL VIEW - MULTi-V 16
8010
9906E
MULTi-V 16
DN50 - PN25
6545A
6546
9929E
3011
4610E
9902A
9946A
MULTi-V 16
2 - PN16
7212
4240
4213
4610B
2460C
6545B
4220
2520
1154
2460D
1,5
9130
2110
9902D
9902C
9946B
2250
2410
6571
1150
3044
2911
9902B
1160
3400
2460A
4610B
1111
9460A
9934A
MULTi-V 16
2 - PN16
MULTi-V 16
2 - VICTAULIC
6521B
6521A
4610A
MULTi-V
SECTIONAL VIEW - MULTi-V 18
MULTi-V 18
8010
9906E
6545A
6546
9929E
4610E
3011
9683
9902A
9946A
3160
7212
4240
4213
4220
4610B
1154
2460C
6545B
2520
9130
2110
9902C
9946C
6521B
6521A
4610A
9902D
7450
9946B
2410
2250
1150
6571
3044
2460A
3400
2460A
4610B
1160
2460D
4610C
4610D
6515
2911
9902B
1111
9460A
9934A
Part list
1111 - Pump casing
1150 - Stage housing with return channel
1154 - Stage centering device
1160 - Stage housing without return channel
2110 - Pump shaft
2250 - Impeller
2410 - Impeller spacer
2460 A - Shaft jacket spacer
2460 C - Mechanical seal keeper ring
2460 D - Rondelle intermdiaire
2520 - Thrust ring
2911 - Bottom shaft end washer
3011 - Lantern ball bearing
3044 - Stage casing with intermediate bearing
3160 - Motor support bearing
3400 - Shaft jacket
MULTi-V
SECTIONAL VIEW - MULTi-V 36
MULTi-V 36C
MULTi-V 36
DN65 - PN25
DN65 - PN16
8010
9906E
6545A
6546
9929E
3011
9683
9902A
9946A
9902C
9946C
7212
4213
1154
4240
4220
2460C
6545B
2520
9130
2460D
2110
2410
1150
2250
3044
9946B
9923B
6571
3400
2460A
1160
9902B
1111
6515
4610D
4610C
Part list
1111 - Pump casing
1150 - Stage housing with return channel
1154 - Stage centering device
1160 - Stage housing without return channel
2110 - Pump shaft
2250 - Impeller
2410 - Impeller spacer
2460 A - Shaft jacket spacer
2460 C - Mechanical seal keeper ring
2460 D - Rondelle intermdiaire
2520 - Thrust ring
3011 - Lantern ball bearing
3044 - Corps dtage avec palier intermdiaire
3160 - Lanterne support moteur
10
9460A
9934A
MULTi-V
SECTIONAL VIEW - MULTi-V 60
6546
MULTi-V 60
6545A
DN60 - PN25
3011
7212
9902A
4213
3160
9923B
4240
9946B
4220
1154
2410
2110
1150
2250
3044
2460D
3400
6571
6545B
9130
4610C
4610D
6515
11
MULTi-V
SECTIONAL VIEW - MULTi-V 80 - 100
9906E
6545A
9929E
6546
7470
7450
9902A
7212
9923B
9946B
6571
4240
4220
NOMENCLATURE
1150 - Stage housing with return channel
2110 - Pump shaft
2250 - Impeller
3400 - Shaft jacket
4220 - Rotary part
| Mechanical
4240 - Stationary ring
| seal
4610 C - O-ring
4610 D - O-ring
6515 - Drain and priming plug
6545 A - Circlip (lantern bearing)
6546 - Circlip (lantern bearing)
6571 - Tirants
7212 - 4 screw coupling
7450 - Coupling guard
7470 - Clip de fixation du protecteur daccouplement
9130 - Outer ealing jacket tube
9902 A - Top shaft end screw
9906 E - Motor fixing screw
9929 E - Nut for fixing screw motor
9923 B - Ecrou M16 des tirants
9946 B - Rondelle contact troite 16
Recommended spare parts.
9130
1150
2110
3400
2250
2250
3400
6515
4610D
4610C
MULTi-V 100
DN100 - PN25
12
MULTi-V
SECTIONAL VIEW - BEARING MULTi-V 80 - 100
13
MULTi-V
Motor 2 pole
10
Q Imp.gpm
Hm
MULTi-V
230
H ft
1m 50hz
3
220
124
700
123
210
200
121
190
600
180
170
118
160
500
150
116
140
114
130
400
120
110
112
100
110
90
300
109
80
108
70
60
107
106
50
200
105
40
104
30
102
20
100
103
10
0
0
0
1
10
2
20
0,2
30
3
50
40
0,4
0,6
0,8
0
Q m3/h
Q l/h
Q l/min
10
40
30
20
10
N.P.S.H
0
0
0
1
Q m3/h
P kW
2,0
1,0
0,0
0
14
Q m3/h
N.P.S.H (mCE)
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
10
15
20
Q Imp.gpm
Hm
H ft
230
MULTi-V
220
220
2m3 50hz
700
210
200
217
190
600
180
170
160
214
500
150
140
212
130
400
120
210
110
100
208
90
80
207
70
206
60
205
50
204
40
300
200
203
30
100
202
20
10
0
0
0
0
1
10
2
20
0,2
30
3
50
40
0,4
0,6
0,8
4
60
70
Q m3/h
5
1,2
80
90
1,4
Q l/h
Q l/min
40
20
N.P.S.H (mCE)
N.P.S.H
0
0
Q m3/h
Q m3/h
P kW
3,0
2,0
1,0
0,0
0
15
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
10
15
20
30 Q Imp.gpm
25
Hm
H ft
MULTi-V
419
210
4m3 50hz
200
417
190
600
180
170
414
160
500
150
140
412
130
400
120
410
110
100
90
408
80
407
70
406
60
405
50
300
200
404
40
403
30
100
402
20
10
0
0
0
2
20
3
40
60
0,5
6
100
80
8
120
1,5
Q m3/h9
Q l/h
Q l/min
40
N.P.S.H
20
0
0
Q m3/h9
Q m3/h
9
P kW
4
3
2
1
0
16
N.P.S.H (mCE)
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
10
20
30
40
50
Q Imp.gpm
Hm
H ft
MULTi-V
240
8m3 50hz
230
819
220
700
210
817
200
190
600
180
170
814
160
500
150
140
812
130
811
120
810
400
110
100
808
90
300
807
80
70
806
60
805
50
804
40
803
30
200
100
802
20
10
0
0
0
2
20
4
40
60
6
80
100
8
120
10
140
160
12
180
200
14
220
Q m3/h
240
Q l/h
Q l/min
60
40
20
N.P.S.H (mCE)
N.P.S.H
0
0
10
12
14
Q m3/h
10
12
14
Q m3/h
P kW
7
6
5
4
3
2
1
0
17
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
10
20
30
40
50
60
70
80
90
Q Imp.gpm
Hm
H ft
MULTi-V
130
16m3 50hz
1611
250
120
1610
110
1609
100
1608
200
90
1607
80
70
1606
60
1605
50
1604
40
150
1603
100
30
1602
20
10
0
0
2
4
50
6
100
10
12
200
150
2
14
16
250
4
18
300
20
22
350
24
400
26
Q m3/h
Q l/h
Q l/min
%
60
50
40
30
20
10
0
8
7
6
5
4
3
2
1
0
N.P.S.H
0
10
12
14
16
18
20
22
24
26
Q m3/h
10
12
14
16
18
20
22
24
26
Q m3/h
P kW
7,0
6,0
5,0
4,0
3,0
2,0
1,0
0,0
18
N.P.S.H (mCE)
0
0
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
20
40
60
80
Q Imp.gpm
Hm
H ft
240
MULTi-V
1814
18m3 50hz
230
1813
220
700
210
1812
200
190
1811
600
180
1810
170
160
1809
150
140
500
1808
130
400
1807
120
110
1806
100
90
300
1805
80
1804
70
200
60
1803
50
40
1802
100
30
20
10
0
0
0
0
12
200
100
1
16
20
24
400
300
4
Q m3/h
Q l/h
Q l/min
20
60
15
40
10
N.P.S.H
20
0
N.P.S.H (mCE)
5
0
12
16
20
24
Q m3/h
12
16
20
24
Q m3/h
P kW
12
8
4
0
0
19
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
50
100
150
Q Imp.gpm
Hm
H ft
MULTi-V
240
230
36m3 50hz
3613
220
3612
210
200
700
3611
190
600
3610
180
170
3609
160
500
150
3608
140
130
3607
400
120
3606
110
100
3605
90
80
300
3604
70
60
200
3603
50
40
3602
100
30
20
10
0
0
0
0
8
100
16
200
24
400
300
4
32
500
40
600
700
10
48
800
12
Q m3/h
Q l/h
14
Q l/min
20
60
15
40
10
N.P.S.H
20
0
5
0
16
24
32
40
48
Q m3/h
16
24
32
40
48
Q m3/h
P kW
20
15
10
5
0
20
N.P.S.H (mCE)
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
50
100
150
200
Q Imp.gpm
Hm
H ft
MULTi-V
240
60m3 50hz
230
220
6012
210
200
700
6011
190
180
600
6010
170
6009
160
150
500
6008
140
6007
130
400
120
6006
110
100
6005
90
80
300
6004
70
60
200
6003
50
6002
40
100
30
20
10
0
10
20
200
30
400
40
600
50
60
1000
800
10
70
Q m3/h
Q l/h
15
Q l/min
60
40
N.P.S.H
20
N.P.S.H (mCE)
0
0
0
0
10
20
30
40
50
60
70
Q m3/h
10
20
30
40
50
60
70
Q m3/h
P kW
25
20
15
10
5
0
0
21
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
100
200
300
400 Q Imp.gpm
Hm
H ft
MULTi-V
190
80m3 50hz
180
600
7/1
170
7/2
160
150
500
6/1
140
6/2
130
5
400
5/1
120
5/2
110
100
4/1
90
300
4/2
80
3
3/1
70
3/2
60
200
50
2/1
40
2/2
30
100
1
1/1
20
10
0
0
0
10
200
20
30
400
40
600
50
800
60
1000
70
1200
10
80
90
1400
100
1600
20
110
1800
Q m3/h
30
Q l/min
Q l/h
12
60
40
20
N.P.S.H
0
0
10
20
30
40
50
60
70
80
90
100
110
Q m3/h
10
20
30
40
50
60
70
80
90
100
110
Q m3/h
P kW
35
30
25
20
15
10
5
0
22
N.P.S.H (mCE)
MULTi-V
HYDRAULIC PERFORMANCES - 2900 rPM
0
100
200
300
400
500 Q Imp.gpm
Hm
H ft
MULTi-V
150
100m3 50hz
500
5/1
140
5/2
130
120
400
4/1
110
4/2
100
90
300
3/1
80
3/2
70
60
200
2/1
50
2/2
40
30
100
1/1
20
10
0
0
0
20
200
40
400
600
60
1000
800
10
15
80
1200
100
1600
1400
20
25
1800
120
2000
30
Q m3/h
2200
Q l/h
35
Q l/min
16
60
12
40
20
N.P.S.H (mCE)
N.P.S.H
0
0
20
40
60
80
100
120
140 Q m3/h
20
40
60
80
100
120
140
P kW
40
35
30
25
20
15
10
5
0
Q m3/h
23
MULTi-V
HYDRAULIC PERFORMANCES - 1450 rPM
0
10
15 Q Imp.gpm
Hm
H ft
MULTi-V
4m3 50hz
55
420
50
150
45
40
414
35
100
30
410
25
20
50
15
10
0
0
0
10
20
0,2
30
0,4
3
50
40
0,6
0,8
60
Q m3/h
70
Q l/h
Q l/min
40
20
N.P.S.H
0
0
Q m3/h
Q m3/h
P kW
0,4
0,2
0,0
24
N.P.S.H (mCE)
MULTi-V
HYDRAULIC PERFORMANCES - 1450 rPM
0
10
15
20
25
Q Imp.gpm
Hm
H ft
MULTi-V
8m 50hz
3
55
819
50
150
45
40
814
35
100
30
810
25
20
50
15
10
0
0
1
10
2
20
30
40
4
50
60
0,5
70
6
80
7
90
100
Q m3/h
Q l/h
1,5
Q l/min
40
20
N.P.S.H (mCE)
2
N.P.S.H
0
0
Q m3/h
Q m3/h
P kW
0,5
0,0
25
MULTi-V
HYDRAULIC PERFORMANCES - 1450 rPM
0
10
20
30
40
50
Q Imp.gpm
Hm
H ft
MULTi-V
16m 50hz
3
35
1612
100
30
25
1609
20
1606
15
50
10
0
1
2
20
3
40
4
60
5
80
6
100
7
120
9
140
10
160
11
180
12
200
13
220
14
15 Q m3/h
240
Q l/h
Q l/min
%
50
40
30
20
10
0
7
6
5
4
3
2
1
0
N.P.S.H
10
11
12
13
14
15 Q m3/h
10
11
12
13
14
15
P kW
1,0
0,8
0,6
0,4
0,2
0,0
0
26
Q m3/h
N.P.S.H (mCE)
0
0
MULTi-V
HYDRAULIC PERFORMANCES - 1450 rPM
0
10
20
30
40
Q Imp.gpm
Hm
H ft
MULTi-V
18m3 50hz
70
1816
200
60
1812
50
40
1809
100
30
20
10
0
2
4
50
6
100
10
12
200
150
2
Q m3/h
Q l/h
Q l/min
60
40
N.P.S.H
20
N.P.S.H (mCE)
0
0
0
0
10
12
Q m3/h
10
12
Q m3/h
P kW
0
0
27
MULTi-V
HYDRAULIC PERFORMANCES - 1450 rPM
0
20
40
60
Q Imp.gpm
60
Hm
H ft
MULTi-V
36m3 50hz
70
3616
60
200
3614
3612
50
3610
40
30
100
3607
20
10
0
4
0
0
12
100
1
16
200
2
20
24
300
4
Q m3/h
400
Q l/h
Q l/min
%
50
40
30
20
10
0
7
6
5
4
3
2
1
0
N.P.S.H
12
16
20
24
Q m3/h
12
16
20
24
Q m3/h
P kW
4
3
2
1
0
28
N.P.S.H (mCE)
MULTi-V
HYDRAULIC PERFORMANCES - 1450 rPM
0
20
40
60
80
100
120
Q Imp.gpm
Hm
H ft
MULTi-V
60m3 50hz
6012
50
150
6009
40
6007
100
30
6005
20
50
10
0
0
0
10
100
15
200
20
25
300
30
500
400
35
Q m3/h
600
Q l/h
10
Q l/min
60
40
N.P.S.H
20
0
N.P.S.H (mCE)
1
0
10
15
20
25
30
35
Q m3/h
10
15
20
25
30
35
Q m3/h
P kW
3
2
1
0
29
MULTi-V
MULTi-V 100 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 16 - DN G1
PN 25 - DN 25
M
Purge
G 3/8
Purge
G 3/8
Purge
G 3/8
Vidange
G 3/8
Vidange
G 3/8
Vidange
G 3/8
DN
25
h2
4 14
2 12
42,4
50
75
50
70
Rp
G1
75
157
171,6
20
20
85
120
250
160
100
CBOV G1 (PN16)
4 12
4 12
100
ORDER
REFERENCE
MOToR
P2
kW
0,37
0,37
0,37
0,37
0,55
0,55
0,55
0,55
0,75
0,75
0,75
0,75
0,75
0,75
1,1
1,1
1,1
1,1
1,1
1,1
1,5
1,5
1,85
1,85
2,2
2,2
3
In (A)
Flange
1x
3x
3x
Type
230 V 400 V 230 V
14/FT85
2,7
14/FT85
0,93
1,6
14/FT85
2,7
14/FT85
0,93
1,6
14/FT85
3,6
14/FT85
1,32 2,28
14/FT85
3,6
14/FT85
1,32 2,28
19/FT100 4,85
19/FT100
1,7
2,94
19/FT100 4,85
19/FT100
1,7
2,94
19/FT100 4,85
19/FT100
1,7
2,94
19/FT100 6,6
19/FT100
2,4
4,15
19/FT100 6,6
19/FT100
2,4
4,15
19/FT100 6,6
19/FT100
2,4
4,15
24/FT115 9,1
24/FT115
3,2
5,5
24/FT115
3,9
6,75
24/FT115
3,9
6,75
24/FT115
4,5
7,8
24/FT115
4,5
7,8
28/FT130
6
10,4
M
mm
140
140
140
140
140
140
140
140
162
170
162
170
162
170
162
170
162
170
162
170
182
193
193
193
193
193
217
4 12
180 212
100
Bote
bornes
180 212
180 212
30
210
204
100
MULTi-V 102-M/2
MULTi-V 102-T/2
MULTi-V 103-M/2
MULTi-V 103-T/2
MULTi-V 104-M/2
MULTi-V 104-T/2
MULTi-V 105-M/2
MULTi-V 105-T/2
MULTi-V 106-M/2
MULTi-V 106-T/2
MULTi-V 107-M/2
MULTi-V 107-T/2
MULTi-V 108-M/2
MULTi-V 108-T/2
MULTi-V 109-M/2
MULTi-V 109-T/2
MULTi-V 110-M/2
MULTi-V 110-T/2
MULTi-V 112-M/2
MULTi-V 112-T/2
MULTi-V 114-M/2
MULTi-V 114-T/2
MULTi-V 116-T/2
MULTi-V 118-T/2
MULTi-V 121-T/2
MULTi-V 123-T/2
MULTi-V 124-T/2
171,6
20
X
mm
107
118
107
118
107
118
107
118
121
127
121
127
121
127
121
127
121
127
121
127
131
151
151
151
151
151
160
PuMP
PN 16
PN 25
G1
DN 25
H
h
H
h
mm
mm
mm
mm
490
305
515
330
528
305
552
330
506
305
515
330
528
305
552
330
506
305
515
330
528
305
552
330
530
345
555
370
568
345
592
370
570
355
595
380
598
355
623
380
590
375
615
400
618
375
643
400
630
415
655
440
658
415
683
440
630
415
655
440
658
415
683
440
650
435
675
460
678
435
703
460
690
475
715
500
718
475
743
500
770
525
795
550
791
525
816
550
856
590
896
630
956
690
1016 750
1055 760
Weight
PN 25
PN 16
PN 25
Victaulic
Motor
Motor
H
h2 Without With Without With
mm
mm
Kg
Kg
Kg
Kg
13
19,7
14,1 20,8
528
305
13
19
14,1 20,1
14,9
24
16
25,1
598
355
14,9 23,9
16
25
16,8 25,9
17,9
27
658
415
16,8 25,8
17,9
26,9
17
27,8
18,1 28,9
658
415
17
27,2 18,1 28,3
17,7
28,4 18,8 29,6
678
435
17,7
27,8 18,8
29
19
29,8 20,1 30,9
718
475
19
29,2 20,1 30,3
24,9 38,9
871
605
26,3 40,3
931
665
28,4 44,4
991
725
30,3 46,3
1030 735
31,1
51,1
MULTi-V
MULTi-V 200 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 16 - DN G1
PN 25 - DN 25
M
Purge
G 3/8
Purge
G 3/8
Purge
G 3/8
Vidange
G 3/8
Vidange
G 3/8
Vidange
G 3/8
DN
25
h2
4 14
2 12
42,4
50
75
50
70
Rp
G1
75
157
171,6
20
20
85
120
250
160
210
204
100
100
CBOV G1 (PN16)
4 12
4 12
100
ORDER
REFERENCE
MOToR
P2
kW
0,37
0,37
0,55
0,55
0,75
0,75
0,75
0,75
1,1
1,1
1,1
1,1
1,5
1,5
1,5
1,5
1,85
2,2
3
3,7
In (A)
Flange
1x
3x
3x
Type
230 V 400 V 230 V
14/FT85 2,65 0,93
1,6
14/FT85 2,65 0,93
1,6
14/FT85 3,55
1,3
2,25
14/FT85 3,55
1,3
2,25
19/FT100
2,9
1,68
2,9
19/FT100
2,9
1,68
2,9
19/FT100 4,85 1,68
2,9
19/FT100 4,85 1,68
2,9
19/FT100 6,65
2,4
4,2
19/FT100 6,65
2,4
4,2
19/FT100 6,65
2,4
4,2
19/FT100 6,65
2,4
4,2
24/FT115
9,1
3,2
5,5
24/FT115
9,1
3,2
5,5
24/FT115
9,1
3,2
5,5
24/FT115
9,1
3,2
5,5
24/FT115
3,9
6,75
24/FT115
4,4
7,6
28/FT130
6,3
10,6
28/FT130
7,8
13,5
M
mm
150
150
150
150
170
170
170
170
170
170
170
170
190
190
190
190
190
190
213
213
4 12
180 212
100
Bote
bornes
180 212
180 212
MULTi-V 202-M/2
MULTi-V 202-T/2
MULTi-V 203-M/2
MULTi-V 203-T/2
MULTi-V 204-M/2
MULTi-V 204-T/2
MULTi-V 205-M/2
MULTi-V 205-T/2
MULTi-V 206-M/2
MULTi-V 206-T/2
MULTi-V 207-M/2
MULTi-V 207-T/2
MULTi-V 208-M/2
MULTi-V 208-T/2
MULTi-V 210-M/2
MULTi-V 210-T/2
MULTi-V 212-T/2
MULTi-V 214-T/2
MULTi-V 217-T/2
MULTi-V 220-T/2
171,6
20
X
mm
123
123
123
123
143
143
143
143
143
143
143
143
148
148
148
148
148
148
158
158
PuMP
PN 16
PN 25
G1
DN 25
H
h
H
h
mm
mm
mm
mm
511
297
536
322
517
297
542
322
511
297
536
322
517
297
542
322
571
331
596
356
571
331
596
356
595
355
620
380
595
355
620
380
619
379
644
404
619
379
644
404
643
403
668
428
643
403
668
428
689
437
714
462
717
437
742
462
737
485
762
510
765
485
790
510
813
533
838
558
886
606
1008 688
1136 760
Weight
PN 25
PN 16
PN 25
Victaulic
Motor
Motor
H
h2 Without With Without With
mm
mm
Kg
Kg
Kg
Kg
15
23,5 15,3 24,8
516,5 296,5
15
23
15,3 24,3
15,5
26
17
27,3
570,5 330,5 15,5 25,5
17
26,8
15,5
26
17,5
27,3
594,5 354,5 15,5 25,5 17,5 26,8
17
28,5 18,3 29,8
618,5 378,5
17
28
18,3 29,3
17
28,5 19,5 29,8
642,5 402,5
17
28
19,5 29,3
21,5
36
24,6
37,1
716,5 436,5 21,5 35,5 24,6 36,6
22,5
37
25,8 38,3
764,5 484,5 22,5 36,5 25,8 37,8
812,5 532,5
23
38
26,3 39,3
860,5 580,5
27
43
983 662,5
28
49
1111 734,5
32
61
31
MULTi-V
MULTi-V 400 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 16 - DN G11/4
PN 25 - DN 32
M
PN 25 - VICTAULIC Union11/4
M
Purge
G 3/8
Purge
G 3/8
Purge
G 3/8
Vidange
G 3/8
Vidange
G 3/8
Vidange
G 3/8
DN
32
h2
4 18
2 12
42,4
50
75
50
78
Rp
G11/4
75
157
171,6
20
20
100
140
250
160
100
4 12
100
4 12
ORDER
REFERENCE
MOToR
P2
kW
0,55
0,55
0,75
0,75
1,1
1,1
1,1
1,1
1,5
1,5
1,5
1,5
1,85
2,2
3
3
3,7
4
In (A)
Flange
1x
3x
3x
Type
230 V 400 V 230 V
14/FT85 3,55
1,3
2,25
14/FT85 3,55
1,3
2,25
19/FT100 4,85 1,68
2,9
19/FT100 4,85 1,68
2,9
19/FT100 6,65
2,4
4,2
19/FT100 6,65
2,4
4,2
19/FT100 6,65
2,4
4,2
19/FT100 6,65
2,4
4,2
24/FT115 9,1
3,2
5,5
24/FT115 9,1
3,2
5,5
24/FT115 9,1
3,2
5,5
24/FT115 9,1
3,2
5,5
24/FT115
3,9
6,75
24/FT115
4,4
7,6
28/FT130
6,3
10,6
28/FT130
6,3
10,6
28/FT130
7,8
13,5
28/FT130
8,4
14,5
M
mm
150
150
170
170
170
170
170
170
190
190
190
190
190
190
213
213
213
240
4 12
180 212
100
Bote
bornes
180 212
180 212
32
210
204
100
MULTi-V 402-M/2
MULTi-V 402-T/2
MULTi-V 403-M/2
MULTi-V 403-T/2
MULTi-V 404-M/2
MULTi-V 404-T/2
MULTi-V 405-M/2
MULTi-V 405-T/2
MULTi-V 406-M/2
MULTi-V 406-T/2
MULTi-V 407-M/2
MULTi-V 407-T/2
MULTi-V 408-T/2
MULTi-V 410-T/2
MULTi-V 412-T/2
MULTi-V 414-T/2
MULTi-V 417-T/2
MULTi-V 419-T/2
171,6
20
X
mm
123
123
143
143
143
143
143
143
148
148
148
148
148
148
158
158
158
170
PuMP
PN 16
PN 25
G1
DN 25
H
h
H
h
mm
mm
mm
mm
537
297
562
322
543
297
567
322
547
307
572
332
547
307
572
332
571
331
596
356
571
331
596
356
595
355
620
380
595
355
620
380
641
389
666
414
669
389
694
414
665
413
690
438
693
413
718
438
717
437
742
462
765
485
790
510
863
543
888
568
936
615
1013 688
1136 760
Weight
PN 25
PN 16
PN 25
Victaulic
Motor
Motor
H
h2 Without With Without With
mm
mm
Kg
Kg
Kg
Kg
14,5
23
15,8 24,3
535,5 296,5
22,5
23,8
15,5
26
16,8 27,3
546,5 306,5
25,5
26,8
16,4
27,9
17,7
29,2
570,5 330,5
27,4
28,7
19
33,5 20,3 34,8
688,5 388,5
33
34,3
30
51
988 682,5
31
60
1111 734,5
32
54
MULTi-V
MULTi-V 400 ELECTRICAL DATA AND DIMENSIONS - 4 POLE
PN 16 - DN 32
M
Purge
G 3/8
H
Vidange
G 3/8
DN
32
4 18
75
78
171,6
20
100
140
250
100
4 12
180 212
ORDER
REFERENCE
MULTi-V 410-M/4
MULTi-V 410-T/4
MULTi-V 414-M/4
MULTi-V 414-T/4
MULTi-V 420-M/4
MULTi-V 420-T/4
MOToR
P2
kW
0,37
0,37
0,55
0,55
0,55
0,55
Flange
Type
14/FT85
14/FT85
19/FT100
19/FT100
19/FT100
19/FT100
1x
230 V
2,9
2,9
4,3
4,3
4,3
4,3
In (A)
3x
400 V
0,93
0,93
1,3
1,3
1,3
1,3
3x
230 V
1,6
1,6
2,25
2,25
2,25
2,25
M
mm
150
150
170
170
170
170
PuMP
DN 32 / 40
X
H
mm
mm
123
704
123
710
143
836
143
836
143
980
143
980
h
mm
490
490
596
596
740
740
Weight kg
Motor
Without
With
kg
kg
16,4
23,9
16,4
24,4
19,5
30
19,5
29,5
23,2
33,7
23,2
33,2
33
MULTi-V
MULTi-V 800 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 16 - DN G11/2
PN 25 - DN 40
M
PN 25 - VICTAULIC Union 2
M
Purge
G 3/8
Purge
G 3/8
Purge
G 3/8
Vidange
G 3/8
Vidange
G 3/8
Vidange
G 3/8
DN
40
h2
4 18
2 12
60,3
80
80
80
88
Rp
G11/2
100
187
187
20
20
280
200
261
250
130
130
4 12
4 12
130
34
MOToR
P2
kW
0,75
0,75
1,1
1,1
1,5
1,5
1,85
2,2
3.00
3.00
3,7
4.00
5,5
5,5
5,5
5,5
7,5
7,5
Flange
Type
19/FT100
19/FT100
19/FT100
19/FT100
24/FT115
24/FT115
24/FT115
24/FT115
28/FT130
28/FT130
28/FT130
28/FT130
28/FT130
38/FF265
28/FT130
38/FF265
38/FF265
38/FF265
1x
230 V
4,85
4,85
6,65
6,65
9,1
9,1
In (A)
3x
400 V
1,68
1,68
2,4
2,4
3,2
3,2
3,9
4,4
6,3
6,3
7,8
8,4
10,5
10,8
10,5
10,8
14,3
14,3
PuMP
PN 16
G1
3x
230 V
2,9
2,9
4,2
4,2
5,5
5,5
6,75
7,6
10,6
10,6
13,5
14,5
4 12
215 252
215 252
215 252
ORDER
REFERENCE
130
Bote
bornes
MULTi-V 802-M/2
MULTi-V 802-T/2
MULTi-V 803-M/2
MULTi-V 803-T/2
MULTi-V 804-M/2
MULTi-V 804-T/2
MULTi-V 805-T/2
MULTi-V 806-T/2
MULTi-V 807-T/2
MULTi-V 808-T/2
MULTi-V 810-T/2
MULTi-V 811-T/2
MULTi-V 812-T4/2
MULTi-V 812N-T4/2
MULTi-V 814-T4/2
MULTi-V 814N-T4/2
MULTi-V 817-T4/2
MULTi-V 819-T4/2
187
20
110
150
M
mm
170
170
170
170
190
190
190
190
213
213
213
240
240
280
240
280
280
280
X
mm
143
143
143
143
148
148
148
148
158
158
158
170
170
194
170
194
194
194
H
mm
574
574
604
604
656
684
714
744
824
854
919
10540
10540
10730
h
mm
334
334
364
364
404
404
434
464
504
534
594
654
654
673
PN 25
DN 25
H
mm
574
574
604
604
656
684
714
744
824
854
919
10540
10540
10730
11140
11330
12230
12830
h
mm
334
334
364
364
404
404
434
464
504
534
594
654
654
673
714
733
823
883
Weight
PN 16
PN 25
Motor
Motor
Without With Without With
Kg
Kg
Kg
Kg
19,5
30
20,5
31
19,5
29,5
20,5
30,5
20,5
32
21,5
33
20,5
31,5
21,5
32,5
22,5
38
24,5
39
22,5
37,5
24,5
38,5
23,5
38,5
25,5
39,5
25.0
41
26
42
26,4
47,4
27,4
48,4
27.0
48,5
28,5
49,5
27,5
50,7
29,1
51,7
28,5
520
30
53
29,8
61,8
30,8
62,8
31,5
58,5
34,3
66,3
36,5
74,8
39
78
40,5
81,5
43,5
84,5
MULTi-V
MULTi-V 800 ELECTRICAL DATA AND DIMENSIONS - 4 POLE
PN 16 - DN 40
M
Purge
G 3/8
H
Vidange
G 3/8
DN
40
4 18
80
88
187
20
110
150
280
130
4 12
215 252
ORDER
REFERENCE
MULTi-V 810-M/4
MULTi-V 810-T/4
MULTi-V 814-M/4
MULTi-V 814-T/4
MULTi-V 819-M/4
MULTi-V 819-T/4
MOTOR
P2
kW
0,55
0,55
0,75
0,75
1,1
1,1
Flange
Type
19/FT100
19/FT100
19/FT100
19/FT100
24/FT115
24/FT115
1x
230 V
4,3
4,3
5,5
5,5
8,5
8,5
In (A)
3x
400 V
1,3
1,3
1,68
1,68
2,4
2,4
3x
230 V
2,25
2,25
2,9
2,9
4,2
4,2
M
mm
170
170
170
170
190
190
PUMP
DN 32 / 40
X
H
mm
mm
143
814
143
814
143
934
143
934
148
1106
148
1134
h
mm
574
574
694
694
854
854
Weight
Motor
Without
With
kg
kg
19,7
30,2
19,7
29,7
22,6
34,6
22,6
33,6
27,8
45,3
27,8
41,8
35
MULTi-V
MULTi-V 1600 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 16 - DN G2
PN 25 - DN 50
M
PN 25 - VICTAULIC union 2
On demand
Purge
G 3/8
Purge
G 3/8
Purge
G 3/8
Vidange
G 3/8
Vidange
G 3/8
Vidange
G 3/8
DN
50
h2
4 18
2 12
60,3
90
90
90
99
Rp
G2
100
187
187
20
20
300
200
261
250
130
130
CBOV G2 (PN16)
4 12
130
4 12
36
MOToR
P2
kW
1,5
2,2
3.00
3,7
4.00
5,5
5,5
7,5
7,5
7,5
Flange
Type
24/FT115
24/FT115
28/FT130
28/FT130
28/FT130
28/FT130
38/FF265
28/FT130
38/FF265
38/FF265
38/FF265
38/FF265
1x
230 V
3,2
4,4
6,3
7,8
8,4
10,5
10,8
10,5
10,8
14,3
14,3
14,3
In (A)
3x
400 V
5,5
7,6
10,6
13,5
14,5
PuMP
PN 16
G1
3x
230 V
190
190
210
210
240
240
280
240
280
280
280
280
4 12
215 252
215 252
215 252
ORDER
REFERENCE
130
Bote
bornes
MULTi-V1602-T/2
MULTi-V1603-T/2
MULTi-V1604-T/2
MULTi-V1605-T/2
MULTi-V1606-T/2
MULTi-V1607-T4/2
MULTi-V1607N-T4/2
MULTi-V1608-T4/2
MULTi-V1608N-T4/2
MULTi-V1609-T4/2
MULTi-V1610-T4/2
MULTi-V1611-T4/2
187
20
125
165
M
mm
140
140
150
150
160
160
180
160
180
180
180
180
X
mm
648,5
723,5
773,5
848,5
928,5
1004
1023
1004
1023
1098
1098
1173
H
mm
368,5
443,5
453,5
528,5
528,5
603,5
623
603,5
623
698
698
773
h
mm
17,2
19,2
20,3
22,3
22,7
24,7
31,7
25,2
32,2
35
35,4
35,8
PN 25
DN 25
H
mm
31
35
41,1
51,3
51,7
53,4
65,7
53,9
66,2
76
76,4
76,8
h
mm
17,2
19,2
20,3
22,3
22,7
24,7
31,7
25,1
32,1
34,1
34,5
36,6
Weight
PN 16
PN 25
Motor
Motor
With Without With Without
Kg
Kg
Kg
Kg
31
17,6
31,4
35
19,6
35,4
41,1
20,7
41,5
51,3
22,7
51,7
51,7
23,1
52,1
53,4
25,1
53,8
65,7
32,1
66,1
53,8
25,5
54,2
66,1
32,5
66,5
75,1
34,5
75,5
75,5
34,9
75,9
77,6
37
78
MULTi-V
MULTi-V 1600 ELECTRICAL DATA AND DIMENSIONS - 4 POLE
PN 16 - DN 50
M
Purge
G 3/8
H
Vidange
G 3/8
DN
50
4 18
90
99
187
20
125
165
300
130
4 12
215 252
MOToR
ORDER
REFERENCE
MULTi-V1606-T/4
MULTi-V1609-T/4
MULTi-V1612-T/4
PuMP
DN 50
In (A)
P2
kW
0,55
0,75
1,1
Flange
Type
19/FT100
19/FT100
24/FT115
3x
400 V
1,3
1,68
2,4
3x
230 V
2,25
2,9
4,2
M
mm
163
163
190
X
mm
143
143
148
Weight
Motor
H
mm
761,5
911,5
1039
h
mm
508,5
658,5
743,5
With
Kg
20,5
24,9
29,3
Without
Kg
30,5
35,9
43,3
37
MULTi-V
MULTi-V 1800 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 16 and 25 - 2 and 4 Pole - DN 50
215
130
4 x 14
h2
4 x 18
90
Order
REFERENCE
38
194
300
252
MULTi-V 1802-T
MULTi-V 1803-T
MULTi-V 1804-T
MULTi-V 1805-T4
MULTi-V 1805N-T4
MULTi-V 1806-T4
MULTi-V 1806N-T4
MULTi-V 1807-T4
MULTi-V 1808-T4
MULTi-V 1809-T4
MULTi-V 1809N-T4
MULTi-V 1810-T4
MULTi-V 1810N-T4
MULTi-V 1811-T4
MULTi-V 1811N-T4
MULTi-V 1812-T4
MULTi-V 1813-T4
MULTi-V 1814-T4
MULTi-V 1809-T
MULTi-V 1812-T
MULTi-V 1816-T
orifice de vidange
20
65
102
125
position
bote bornes
orifice de purge
Motor
P2
kW
2,2
3
4
5,5
5,5
5,5
5,5
7,5
7,5
9
11
11
11
11
11
15
15
15
1,1
1,5
2,2
In (A)
3X230
3X400V
7,6
4,4
10,6
6,3
14,5
8,4
10,5
10,8
10,5
10,8
14,3
14,3
17
19,2
20
19,2
20
19,2
26,5
26,5
26,5
4,34
2,5
5,92
3,4
8,34
4,8
Pump
P max
bar
16
16
16
16
16
16
16
16
16
16
16
16
bar
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
Flange
type
24/FT115
28/FT130
28/FT130
28/FT130
38/FF265
28/FT130
38/FF265
38/FF265
38/FF265
38/FF265
42/FF300
38/FF265
42/FF300
38/FF265
42/FF300
42/FF300
42/FF300
42/FF300
24/FT115
24/FT115
28/FT130
H
mm
714
749
863,5
898
968
932,5
1003
1072
1072
1141
1281
1141
1281
1210
1350
1350
1419
1419
955,5
1025
1198
h2
mm
419
429
464
498
518
533
553
621,5
621,5
690,5
720,5
690,5
720,5
759,5
789,5
789,5
858,5
858,5
660,5
729,5
877,5
M
mm
190
215
240
240
300
240
300
300
300
300
340
300
340
300
340
340
340
340
190
190
215
X
mm
140
150
160
160
180
160
180
180
180
180
240
180
240
180
240
240
240
240
140
140
150
Weight (kg)
With packing
With
Without
Motor
Motor
57,7
42
67,5
44,5
76,5
46,5
91,5
48,5
99,5
56,5
93,5
50,5
101,5
58,5
115,5
62,5
115,5
62,5
115,5
66,5
146,5
74,5
121,5
66,5
145,5
73,5
125,5
70,5
149,5
77,5
149,5
77,5
153,5
81,5
153,5
81,5
68,3
56
76,1
60,5
94
70
MULTi-V
MULTi-V 3600 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 16 - 2 and 4 Pole - DN 65
h2
Orifice
de purge
4 x 18
145
Orifice
de vidange
195
125
80
105
35
235
320
ORDER
REFERENCE
MULTi-V 3602-T
MULTi-V 3603-T4
MULTi-V 3603N-T4
MULTi-V 3604-T4
MULTi-V 3605-T4
MULTi-V 3605N-T4
MULTi-V 3606-T4
MULTi-V 3606N-T4
MULTi-V 3607-T4
MULTi-V 3607-T
MULTi-V 3610-T
MULTi-V 3612-T
4 x 14
239
MOTOR
P2
kW
4
5,5
5,5
7,5
9
11
11
11
15
1,5
2,2
3
In (A)
3X230
14,5
5,92
8,34
11,3
3X400V
8,4
10,5
10,8
14,3
17
19,2
20
19,2
26,5
3,4
4,8
6,5
195
PUMP
P max
bar
16
16
16
16
16
16
16
16
16
16
16
16
Flange
type
28/FT130
28/FT130
38/FF265
38/FF265
38/FF265
42/FF300
38/FF265
42/FF300
42/FF300
24/FT115
28/FT130
28/FT130
H
mm
840
886
906
952
1094
1174
1094
1174
1312
940
1220
1220
h2
mm
440
486
506
552
644
674
644
674
812
660
900
900
M
mm
240
240
280
280
298
340
298
340
340
190
213
213
X
mm
170
170
194
194
194
235
194
235
235
148
158
158
Weight (kg)
With packing
With
Without
Motor
Motor
96
64
105,5
66,5
119,5
74,5
128
77
152,5
81,5
172,5
88,5
162
82
176
89
196,5
103,5
92,5
77,5
120
91
124
92
39
MULTi-V
MULTi-V 3600 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 25 - 2 Pole - DN 65
h2
Orifice
de purge
Orifice
de vidange
220
8 x 18
145
80
120
125
35
4 x 14
220
262
260
320
ORDER
REFERENCE
MULTi-V 3602-T
MULTi-V 3603-T4
MULTi-V 3603N-T4
MULTi-V 3604-T4
MULTi-V 3605-T4
MULTi-V 3605N-T4
MULTi-V 3606-T4
MULTi-V 3606N-T4
MULTi-V 3607-T4
MULTi-V 3608-T4
MULTi-V 3609-T4
MULTi-V 3610-T4
MULTi-V 3611-T4
MULTi-V 3612-T4
MULTI-V3613C-T4
40
MOTOR
P2
kW
4
5,5
5,5
7,5
9
11
11
11
15
15
18,5
18,5
22
22
30
In (A)
3X230
14,5
3X400V
8,4
10,5
10,8
14,3
17
19,2
20
19,2
26,5
26,5
33
33
38,1
38,1
53
PUMP
P max
bar
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
Flange
type
28/FT130
28/FT130
38/FF265
38/FF265
38/FF265
42/FF300
38/FF265
42/FF300
42/FF300
22/FT300
42/FF300
42/FF300
42/FF300
42/FF300
55/FF350
H
mm
855
901
921
967
1109
1189
1109
1189
1327
1327
1322
1460
1517
1517
1774
h2
mm
455
501
521
567
659
689
659
689
827
827
827
965
965
965
1175
M
mm
240
240
280
280
298
340
298
340
340
340
340
340
350
350
415
X
mm
170
170
194
194
194
235
194
235
235
235
230
230
253
253
255
Weight (kg)
With packing
With
Without
Motor
Motor
98
66
107,5
68,5
121,5
76,5
130
79
157,5
83,5
177,5
90,5
161
84
178
91
198,5
105,5
199
106
215
107
221
113
232
115
232
115
275,9
117,9
MULTi-V
MULTi-V 6000 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
PN 16 and 25 - 2 et 4 Pole - DN 80
X
h2
160
orifice
de purge
8 x 18
orifice
de vidange
80
220
105
30
4 x 14
260
Order
REFERENCE
MULTi-V 6002-T4
MULTi-V 6002N-T4
MULTi-V 6003-T4
MULTi-V 6004-T4
MULTi-V 6004N-T4
MULTi-V 6005-T4
MULTi-V 6006-T4
MULTi-V 6007-T4
MULTi-V 6008-T4
MULTi-V 6009-T4
MULTI-V6010C-T4
MULTI-V6011C-T4
MULTI-V6012C-T4
MULTi-V 6005-T
MULTi-V 6007-T
MULTi-V 6009-T
220
320
260
Motor
P2
kW
5,5
5,5
7,5
11
11
15
15
18,5
22
22
30
30
30
1,5
2,2
3
In (A)
3X230
3X400V
10,5
10,8
14,3
20
19,2
26,5
26,5
33
38,1
38,1
53
53
53
5,92
3,4
8,34
4,8
11,3
6,5
Pump
P max
bar
16
16
16
16
16
16
16
16
16
16
16
bar
25
25
25
25
25
25
25
25
25
25
25
Flange
type
28/FT130
38/FF265
38/FF265
38/FF265
42/FF300
42/FF300
42/FF300
42/FF300
42/FF300
42/FF300
55/FF350
55/FF350
55/FF350
24/FT115
28/FT130
28/FT130
H
mm
872
941
1003
1064
1204
1327
1327
1449
1479
1541
1853
1853
1853
1002
1160
1221
h2
mm
472
491
553
614
644
767
767
889
889
951
1254
1254
1254
707
840
901
M
mm
240
300
300
300
340
340
340
340
380
380
415
415
415
190
215
215
X
mm
160
180
180
180
240
240
240
240
260
260
255
255
255
140
150
150
Weight (kg)
With packing
With
Without
Motor
Motor
96,5
53,5
104,5
61,5
117,5
64,5
123
68
147,5
75,5
152,5
80,5
153,5
81,5
175
87
187
88
190
91
277,5
119,5
278,6
120,6
279,7
121,7
80,1
64,5
95,5
71,5
101,5
75,5
41
MULTi-V
MULTi-V 8000 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
X
Position
bote bornes
ASP.
REF.
h2
8x23 8x19
4x14
orifice
de vidange
180
280
190
orifice
de purge
100
45
350
350
264
PN25
PN16
380
Order
REFERENCE
Multi-V8001/1-T4
Multi-V8001N-T4
Multi-V8001-T4
Multi-V8002/1N-T4
Multi-V8002/1-T4
Multi-V8002/2-T4
Multi-V8002N-T4
Multi-V8002-T4
Multi-V8003/1-T4
Multi-V8003/2-T4
Multi-V8003-T4
Multi-V8004/1-T4
Multi-V8004/2-T4
Multi-V8004-T4
Multi-V8005/1-T4
Multi-V8005/2-T4
Multi-V8005-T4
Multi-V8006/1-T4
Multi-V8006-/2-T4
Multi-V8006/2-T4
Multi-V8007/1-T4
Multi-V8007/2-T4
42
199
Motor
P2
kW
4
5,5N
5,5
11N
9
7,5
11N
11
15
15
18,5
22
18,5
22
30
30
30
37
37
30
37
37
In (A)
3X230 3X400V
13,68
7,9
10,3
10,8
19,6
17
13,8
19,6
20
26,5
26,5
32,2
38,1
32,2
38,1
53
53
53
64,5
64,5
53
64,5
64,5
Pump
P max
bar
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
bar
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
Flange
type
28/FT130
38/FF265
28/FT130
42/FF300
38/FF265
38/FF265
42/FF300
38/FF265
42/FF300
42/FF300
42/FF300
42/FF300
42/FF300
42/FF300
55/FF350
55/FF350
55/FF350
55/FF350
55/FF350
55/FF350
55/FF350
55/FF350
H
mm
831
919,5
874,5
1233
1039,5
1004,5
1233
1039,5
1318
1318
1337
1446
1422
1446
1611
1611
1611
1696
1718
1718
1803
1803
h2
mm
539
559
539
757
644
644
757
644
842
842
842
927
927
927
1012
1012
1012
1097
1097
1097
1182
1182
M
mm
217
279
235
325
280
279
325
280
325
325
325
370
325
370
415
415
415
415
415
415
415
415
X
mm
160
182
168
208
182
182
208
182
208
208
235
249
235
249
255
255
255
275
275
255
275
275
Weight (kg)
With packing
Without
With
Motor
Motor
86,5
115,5
86,5
119,5
94,5
133,9
98,5
148,5
98,5
158,5
106,5
183,5
98,5
158,5
106,5
183,5
110
194
110
194
110
209
119
213
119
236
119
236
126
315
126
315
126
315
130
319
130
341
130
341
137
345
137
345
MULTi-V
MULTi-V 100.00 ELECTRICAL DATA AND DIMENSIONS - 2 POLE
X
Position
bote bornes
ASP.
REF.
4x14
orifice
de vidange
180
280
190
h2
8x23 8x19
orifice
de purge
100
45
350
350
264
PN25
PN16
380
Order
REFERENCE
MULTI-V10001/1-T4
MULTI-V10001-T4
MULTI-V10002/2-T4
MULTI-V10002/1-T4
MULTI-V10002-T4
MULTI-V10003/2-T4
MULTI-V10003/1-T4
MULTI-V10003-T4
MULTI-V10004/2-T4
MULTI-V10004/1-T4
MULTI-V10004-T4
MULTI-V10005/2-T4
MULTI-V10005/1-T4
MULTI-V10005-T4
199
Motor
P2
KW
7,5
9
15
15
18,5
22
30
30
30
37
37
45
45
45
I (A)
400V
13,8
17
26,5
26,5
32,2
38,1
53
53
53
64,5
64,5
79
79
79
Pump
Pmax
bar
16
16
16
16
16
16
16
16
16
16
-
bar
25
25
25
25
25
25
25
25
25
25
25
25
25
25
Flange
type
38/FF265
38/FF265
42/FF300
42/FF300
42/FF300
42/FF300
55/FF350
55/FF350
55/FF350
55/FF350
55/FF350
55/FF400
55/FF400
55/FF400
H
mm
932,5
967,5
1259
1259
1278
1400
1480
1480
1578
1600
1600
1704
1704
1704
H2
mm
572
572
783
783
783
881
881
881
979
979
979
1077
1077
1077
M
mm
279
280
325
325
325
370
415
415
415
415
415
456
456
456
X
mm
182
182
208
208
235
249
255
255
255
275
275
275
275
275
Weight (kg)
With packing
Without
With
Motor
Motor
145
95
155
95
192
108
192
108
207
108
234,5
112,5
281,5
115,5
281,5
115,5
314,5
125,5
336,5
125,5
336,5
125,5
371
134
371
134
371
134
43
MULTi-V
ACCESSORiES
Features
a) Electrical
-T Types : three-phase 230-400 V - 50 Hz or
Three-phase 400 V above 4 kW.
- 50 Hz
-M Types: single phase 230V
with outside capacitor.
- Motor protection overload circuit breaker.
-Connections to the motor terminal by gland
stuffing box.
Discontactor
for TP motor protection
Check valve
b) Installation
- On foundation block with anchor bolt fixing.
-Pump installation suction with compulsory
strainer-foot valve, or pump on-load on
storage tank or on town water network with
guard system against running dry.
-Connection to the pump by oval or round
mating pipe flanges for the PN16 series, and
by round mating pipe flanges or Victaulic
clip for the PN 25 series.
Isolation valve
Anti-vibration sleeves
c) Packaging
PN 16 series
-with oval flanges - pump supplied with castiron oval mating pipe flanges, gaskets and
bolts;
-with round flanges - pump supplied with gaskets and bolts without mating pipe flanges
(optional).
PN 25 series
-with round flanges - pump supplied with gaskets and bolts without mating pipe flanges
(optional).
-with Victaulic unions - pump supplied with
gaskets and bolts (Victaulic clips optional).
Anti-vibration sleeves
d) Maintenance
Spare part replacement recommended ()
susceptible to wear and tear.
44
53, bd de53,
la Rpublique
- Espace -Lumire
Bt. 6 - -78403
bd de la Rpublique
Espace -Lumire
Bt. 6 Chatou
- 78403Cedex
ChatouFrance
Cedex
SALMSON
Contact
: +33 :(0)
820 0000 44 | www.salmson.com
SALMSON
Contact
0820
Fax. : +33
Fax. :(0)1
01 30 09 82 82