You are on page 1of 211

EPLAN electric P8 training by Sysnet Controls Sdn. Bhd.

http://www.eplan.com.my/

















Version 1.7.12
Basic Training

Date : 10
th
September 2007 14
th
September 2007
Venue : Sysnet Controls Sdn Bhd Training Room






















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 1/213

Day 1 .......................................... Error! Bookmark not defined.
Installation .................................. Error! Bookmark not defined.
Project ........................................ Error! Bookmark not defined.
Opening a project ................................. Error! Bookmark not defined.
Project management ............................ Error! Bookmark not defined.
User interface ............................ Error! Bookmark not defined.
Creating / Configuring a workspace ..... Error! Bookmark not defined.
Saving a new workspace ...................... Error! Bookmark not defined.
Changing the key assignment for a command .... Error! Bookmark not
defined.
Creating an own icon and linking it to an action .. Error! Bookmark not
defined.
Transferring user-specific settings to a different computer in the
network ................................................. Error! Bookmark not defined.
Inserting a symbol ................................ Error! Bookmark not defined.
Exercise ................................................ Error! Bookmark not defined.
Symbol selection navigator .................. Error! Bookmark not defined.
Pair cross-reference or contact image at motor overload switch .. Error!
Bookmark not defined.
Notes Pad ............................................. Error! Bookmark not defined.
Day 2 .......................................... Error! Bookmark not defined.
New project ................................ Error! Bookmark not defined.
Changing the project structure .. Error! Bookmark not defined.
GED ........................................... Error! Bookmark not defined.
Hyperlink/image .................................... Error! Bookmark not defined.
External documents .............................. Error! Bookmark not defined.
Texts ..................................................... Error! Bookmark not defined.
Drawing a graphic ................................ Error! Bookmark not defined.
Layer management .............................. Error! Bookmark not defined.
Part / Device selection ............... Error! Bookmark not defined.
Part selection ........................................ Error! Bookmark not defined.
Device selection ................................... Error! Bookmark not defined.
Part management ...................... Error! Bookmark not defined.
Inserting a device ................................. Error! Bookmark not defined.
Generating a type ................................. Error! Bookmark not defined.
Writing back cable conductor data ....... Error! Bookmark not defined.
Synchronizing the parts database ........ Error! Bookmark not defined.

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 2/213
Device list ............................................. Error! Bookmark not defined.
Setting a user-defined part selection (project-specific) ................. Error!
Bookmark not defined.
Management Parts selection ................ Error! Bookmark not defined.
Management Parts management ......... Error! Bookmark not defined.
Notes Pad ............................................. Error! Bookmark not defined.
New function in Terminals navigator ........ Error! Bookmark not
defined.
Unplaced functions .................... Error! Bookmark not defined.
Interconnecting devices ............. Error! Bookmark not defined.
Connected functions .................. Error! Bookmark not defined.
Function types ........................... Error! Bookmark not defined.
Moving a main function and synchronizing data.. Error! Bookmark not
defined.
Macro techniques ...................... Error! Bookmark not defined.
Window macro ...................................... Error! Bookmark not defined.
Symbol macro ...................................... Error! Bookmark not defined.
Page macro .......................................... Error! Bookmark not defined.
Drag-and-drop ...................................... Error! Bookmark not defined.
Macro project / Macro variants ............. Error! Bookmark not defined.
Modifying a macro variant in the schematic ........ Error! Bookmark not
defined.
Updating the macro .............................. Error! Bookmark not defined.
Placeholder texts .................................. Error! Bookmark not defined.
Notes Pad ............................................. Error! Bookmark not defined.
Day 4 .......................................... Error! Bookmark not defined.
Numbering ................................. Error! Bookmark not defined.
Cable numbering with source / target ... Error! Bookmark not defined.
Plugs .................................................... Error! Bookmark not defined.
DT numbering ....................................... Error! Bookmark not defined.
Interruption points ...................... Error! Bookmark not defined.
Interruption point navigator ................... Error! Bookmark not defined.
Modifying the interruption point symbol Error! Bookmark not defined.
Diagonal "Exercise project TYP01" .......... Error! Bookmark not
defined.
Bundle ........................................ Error! Bookmark not defined.
Potential / signal ........................ Error! Bookmark not defined.
Connection numbering .............. Error! Bookmark not defined.

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 3/213
Numbering only for a specific potential or signal . Error! Bookmark not
defined.
How can I number only the connections for a group of DTs (for
example -F)? ........................................ Error! Bookmark not defined.
Contact image ............................ Error! Bookmark not defined.
Setting up personal properties ... Error! Bookmark not defined.
Changing the zoom, pan and scroll functions of the mouse
................................................... Error! Bookmark not defined.
Notes Pad ............................................. Error! Bookmark not defined.
Day 5 .......................................... Error! Bookmark not defined.
Tips and tricks ............................ Error! Bookmark not defined.
Finding the next free counter ................ Error! Bookmark not defined.
Placing a DT without the Properties dialog box opening .............. Error!
Bookmark not defined.
Predefinition of the identifiers ............... Error! Bookmark not defined.
Part selection with filter to identifier ...... Error! Bookmark not defined.
Sorting the terminals as drawn in the schematic (EPLAN 5 sorting
setting: .................................................. Error! Bookmark not defined.
Terminal on left) ................................... Error! Bookmark not defined.
Displaying property numbers ................ Error! Bookmark not defined.
Renaming property designations .......... Error! Bookmark not defined.
Check runs / Message management .... Error! Bookmark not defined.
Report generation ................................. Error! Bookmark not defined.
Creating ......... Error! Bookmark not
defined.
Drawing a terminal strip with motor
and placing a dynamic terminal
diagram form on the page ...... Error!
Bookmark not defined.

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 4/213
Updating the output when opening
the page ......... Error! Bookmark not
defined.
Labeling ......... Error! Bookmark not
defined.
Outputting a bill of materials to MS
Excel Error! Bookmark not defined.
Data transfer ......................................... Error! Bookmark not defined.
Entire project . Error! Bookmark not
defined.
Importing individual master data
........ Error! Bookmark not defined.
Notes Pad ............................................. Error! Bookmark not defined.

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 5/213

1. PROJECT MANAGEMENT DATABASE

Project management displayed all the information contained in a project. Here you
can manage your project files such as:
a) Import / Export project.
b) Back up / Restore project.
c) Creating Basic Project.
d) Creating Project Template.
e) Sending Project via email.
f) Compress and Reorganize project.
g) Opening, rename, copying and delete project.
h) Editing Project Properties.
i) Outputting Project Information.
PROJECT > MANAGEMENT



Import / Export project.
Eplan project can be import and export ( in .epj format) in the project management.

To import a project

Project > Management > Organize > Import


















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 6/213
Looks for a .epj format files and click Open





















Select OK













Process of importing










EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 7/213


Here you go, your newly imported project




















To export a project

Project > Management > Choose A Project > Organize > Export


















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 8/213



Choose the directory where you want to output you exported project. Press OK after
you choose the directories.





















Eplan project exported.












EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 9/213

Back up / Restore project.
To back up a project

Project > Management > Choose A Project > Organize > Back up



Select the method you want use to back up your files and the medium where you
want your back up to be stored. Press OK when you done.
































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 10/213


Saving Method

Store Additionally Backing up copies the project to the target data
medium. In other words, the project remains
available in exactly the same form.

File Off for external processing The file-off function is used to copy the project to
the target data medium for additional external
editing or modification. The original project is then
locked to prevent any modifications being made to
it. Thus, only the filed-off project can be changed.
You can, however, open the original project on a
read only basis.
Archive Archiving is used to file completed projects to a
target data medium. The entire original project is
deleted from the current hard disk, leaving only an
information file. Archived projects are also
identified by a special symbol in the project
selection windows.

Press OK
























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 11/213


Process Of backing up











Your selected project has successfully been back up.
































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 12/213


To restore a project

Project > Management > Organize > Restore







Select the directory where you saved your back up files then press OK




































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 13/213


Press yes to overwrite the existing files with the back up files.













Process of restoring the files














Press OK















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 14/213


Creating Basic Project.
When you create a basic project from an existing project, the pages and all project-
specific settings are saved in the basic project. A basic project has the ebp suffix.
When you create a project from a basic project, the following settings from the basic
project are adopted in the new project:
All project related settings. Project related settings are the settings under
Options > Settings > Projects > "Project name".
Schemes for the page and device structure.
All pages. All pages in the basic project are adopted in the new project. Since
the pages are adopted you cannot change the page structure in the newly
created project.
Project > Management > Choose A Project > Extra > Create Basic Project





















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 15/213

Create a new name for your project template and click save.





















Project template
When you create a project template from an existing project, all project-specific
settings and the schemes for the project structure are saved. A project template has
the ept suffix.
When you create a project from a project template, the following data and settings
are adopted:
All project related settings. Project related settings are the settings under
Options > Settings > Projects > "Project name".
Schemes for the page and device structure. Since no pages are adopted from
the project template, you can change both the page and device structure in
the newly created project.









EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 16/213


Project > Management > Choose A Project > Extra > Create Project Template.
























Create a new name for your project template and click save













EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 17/213

Sending Project via email.
Project > Management > Choose A Project > Organize > Send By Email






















Click Yes





















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 18/213


Process of sending e-mail.













Link to e-mail account. Type in the e-mail address and sent






























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 19/213

Compress and Reorganize project.
This function irretrievably removes any deleted pages from the project and removes
gaps in the database. The project can be examined at the same time for data
consistency.

To compress a project.

Project > Management > Choose A Project > Organize > Compress



















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 20/213

Click Yes









Click Yes










Process of compressing project
























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 21/213


Click Close



















To reorganize the project

Project > Management > Choose A Project > Organize > Reorganize




















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 22/213

Click Yes










Process of reorganize the project.


































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 23/213


Opening, rename, copying and delete project


Opening a project


Project > Management > Choose A Project > Organize > Open






































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 24/213


Renaming a project

Project > Management > Choose A Project > Organize > Rename








Type in a new project name.



Your project has been rename











EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 25/213

Copying a project

Project > Management > Choose A Project > Organize > Copy



























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 26/213

Click OK


















Your project has been copied to a new files.


























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 27/213

Deleting a project

Project > Management > Choose A Project > Organize > Delete





























Click Yes to all















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 28/213


Editing Project Properties.

Project > Management > Choose A Project > Edit
















Change your properties accordingly and click save after the modification.

























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 29/213


Outputting project information

Project > Management > Choose A Project > Extra > Output Project
Information























Click OK




















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 30/213

Overview Of report.
































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 31/213


2. PLOT FRAMES

Defines the logical structure of the schematic, that is, the assignment of a plot frame
to a page determines the header, page size, and the division into rows and columns.
There are additional special texts available, the row and column texts.

Copying Existing Plot Frames

Utilities > Master data > Plot frame > Copy


































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 32/213

Select the plot frame you want to copy, create a new name youre your copied plot
frame and then click open.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 33/213

Creating New Plot Frames

Utilities > Master data > Plot frame > New









































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 34/213



Create a new name for your Plot Frame and Click Save.






















Set the setting for your new plot frame and click OK



To create what
















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 35/213

To displayed information in the plot frame, go to

Insert > Special Text > Project Properties/ Page Properties














By pressing the icon, you can choose the properties available.


























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 36/213

Choose the properties you want to displayed and click OK













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 37/213

Make sure the properties you choose is correct. Then Press OK



























Place where you want the properties to be appear in the plot frame.

















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 38/213


Once the plot frames is completed, just close the screen. Its auto save.











3. Symbols

Utilities > Master data > Symbol library > New
Firstly, if you are created a symbol in the totally new symbol libraries, follow the step as
below. If you want to create a symbol in a existing symbol libraries, ignore step 1, 2 and 3
below.
























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 39/213

Create a name for your symbol libraries






















Click OK






















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 40/213

To create a new symbol,

Utilities > Master data > Symbol > New























Select a variant for the symbol and click OK



















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 41/213

Type in a symbol name and the symbol description and click the icon to define
the symbol categories.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 42/213

Select the category your symbol will fall into. Let said that I want to create a coil, go
to Coils, contacts, and protective circuits, select the appropriate attributes for the
particular symbols.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 43/213


Select OK












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 44/213

The button is the insertion point of the symbol, you can used the free graphics
drawing to help you to designed the symbol.



















Example of a designed symbols.























Free Graphics Drawing

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 45/213



Now right click on top frame toolbar and activate the symbol editor toolbar.






















the connection point for the symbol.

















Symbol Editor Toolbar

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 46/213


To displayed the properties such as technical characteristics, counter, identifier
when you insert your symbol in your design in future,

Insert > Properties Text
















Or







In the
placement of properties dialog, press the button.

















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 47/213

Choose what are the properties you want to displayed and click OK.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 48/213

Once OK


Press the OK button.




















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 49/213

To have different variants in the symbol

Go to Utilities > Master Data > Symbol > New Variant.
















Choose the variant you want and click OK


























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 50/213

Select how you want the new variant to be rotated. Example Variant A rotated by 90
0
.
Continue the same step for different type of variant.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 51/213


Click the button if you have satisfied with your symbol.

























Now go to

Option > Setting > Projects > Project Name > Management > Symbol Libraries







EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 52/213
Press the button,

























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 53/213


Select the symbol libraries and click Open.





















Press OK






















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 54/213

Now go to

Insert > Symbol







Press the button,











Press button,























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 55/213


Type In the symbol libraries name and the description name, Click OK once you
have finished.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 56/213


Now pressed the button in the value column.






















Tick in the newly created symbol libraries. Press OK after you have completed





















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 57/213

Press OK























Here you go, your newly created symbol.





















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 58/213


4. Forms


Copying Existing Forms

Utilities > Master Data > Form > Copy.







































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 59/213

Select the type of form type.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 60/213

Select the form you want to copy and click Open.





















Create a name for your form.























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 61/213

If you want to modified the text properties;

Insert > Special text > Project properties or Page properties.












Choose what information you want to displayed by pressing the button.






























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 62/213

Select the type of properties you want to displayed in the form, click OK after you
have selected the properties












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 63/213

Press OK



























Click where you the properties text to be displayed when you generate the report on
the future.
















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 64/213

Close the window after you have done with your modification.
















Creating New Forms

Utilities > Master Data > Form > New


























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 65/213


Select the type of form you want to modified,






















Create a new name for your form. Click save after you have done with your setting.





















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 66/213
Free Graphics Line Toolbar


Change the setting accordingly and click OK after you have done with your setting.























Use the free graphics line toolbar to design your form.




















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 67/213

To insert the text properties, go to

Insert > Special text > Project Properties / Page Properties














Click the to choose the properties you want to displayed when you generate the
form.



























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 68/213


Select the properties you want to output and click OK












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 69/213


Press OK




























Place where you want to output in the form.















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 70/213

Close the window after you have modified the form.










Defining Form Properties

Form type:
Select the desired form type from the drop-down list (such as "Terminal connection
diagram", "Table of contents", "Order list", etc.). This property defines the type of
form. Each form type is assigned a particular ID. This is used internally to generate
the list of properties available (placeholder texts) that can be used during the editing
of the form. Thus each form has a specific list of available fields. The form type ID is
also used to generate the list of forms which are available in the "Reports" dialog for
the generation of a particular document. For instance, if you want to generate a
device tag list, only the forms present which are designated as device tag list forms
are offered for selection.
Property name / Value list:
The available properties are displayed depending on the selected category. Some of
them, for example "Company code" and "Modification date" have already been
assigned values that can't be changed. Others, for example "Description" and
"Version", can be assigned values or their existing values can be changed.
The following properties are particularly important:
Name (form, plot frame): "Data" category, file name, write-protected
Description (form, plot frame): "Data" category, string (multi-lingual)
Plot frame to edit form: "Settings" category, string
Form handling: "Settings" category, drop-down list; specifies the form as a
static or dynamic form.
Regenerate main sub-header: "Settings" category, special dialog
Number of columns / rows: "Settings" category, integer; maximum number of
columns / rows generated on a page
Column width / row height: "Settings" category, decimal (in "mm"); specifies
the width of columns / height of rows in the form.

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 71/213
Form structure: "Settings" category, drop-down list; order in which rows and
columns are filled in. The process always starts in the upper left. "By row"
means that first all cells of a row are filled in before switching to the next row.
In this case, bridges are displayed vertically. "By column" means that first all
cells of a column are filled in before switching to the next column. In this case,
bridges are displayed horizontally.
Dynamic row adjustment: "Settings" category, check box. If indirect properties
are indexed with 0, then the values for all (meaningful) indices are printed
together. This is generally done using one-row lists separated by semicolons.
In forms, however, you have the option of printing these values as
independent elements (rows / columns).
Example: Indirect goal.Name(0) gives M1;M2;X1:2. If dynamic row
adjustment is activated, then these four target names are printed one under
the other.
Jumpers: Height of first level: "Settings" category, decimal (in "mm"); height of
a jumper in the first level in the terminal diagram. The distance to the next
jumper is defined by the property "Jumpers: Spacing".
Jumpers: Distance: "Settings" category, decimal (in "mm"); distance between
two jumpers in neighboring levels. (The height of the first jumper is defined by
the property "Jumpers: Height of first level".)
Jumpers: Radius of connecting points: "Settings" category, decimal (in "mm");
since the nodes of jumpers are graphically shown in the terminal diagram with
a small filled circle, you specify the radius of this circle with this property (in
software coordinates). (Start and end "legs" don't have dots.)
Jumpers: Radius for nodes: "Settings" category, decimal (in "mm"); if jumpers
are shown graphically in the terminal diagram, then a small filled circle is set
on the base line on each "leg" of the jumper. The radius of this circle is
specified with this property (in software coordinates).
Jumpers: Height of external wire jumper: "Settings" category, decimal (in
"mm"); height of an internal / external jumper in the first level in the terminal
diagram. If the matching property is not set, this is used instead of "Jumpers:
height of first level".
Jumpers: Height of internal / external wire jumper: "Settings" category,
decimal (in "mm"); distance between two internal / external wire jumpers in
neighboring levels. If the property is not set, "Jumpers: distance" is used.
Format for automatic page description: "Settings" category, special dialog;
format for the page description automatically assigned when generating
report lists.
Assignment 'Index to graphic': "Settings" category, special dialog;
configuration property which assigns each graphic an index value; the
selection of graphics is this done in the "Fixed graphic" placeholder by giving
the index value.
Assignment: Function definition to graphic: "Settings" category, special dialog;
assignment of a terminal type number to a symbol variant. Used when
generating a page in order to create a fixed symbol graphic.

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 72/213
Connection diagram: Suppress jumper targets: "Settings" category, integer;
determines what type of jumper targets is not to be displayed in connection
point diagrams:
0 = Show all jumper targets
1 = Hide saddle jumper targets, show wire jumper targets
2 = Suppress saddle and wire jumper targets.
Connection diagram: Number of graphical levels (internal / external):
Category "Settings", Integer
Connection diagram: New row in the case of graphical overlapping: "Settings"
category, check box; if this property is set, then in case of overlapping of
graphical views in connection diagrams, a new row is started or an empty row
inserted. An overlap occurs when one of the relevant graphics layers does not
contain the same device as the next record on the same level. More compact
views can be implemented in connection diagrams in this way. The properties
"Connection diagram: Number of graphical levels (internal) / (external)" must
be set correctly.
Structure identifier overview: "Settings" category, drop-down list for selection
of structure identifiers to be displayed in the form.
Combine multi-level terminals: "Settings" category, check box; useful for
terminal line-up diagrams.
Assignment of property / value to graphic: "Settings" category, special dialog;
assignment of a property and / or value to a symbol variant.
Jumper display: "Settings "category, drop-down list (line, angle)
Jumpers: Line thickness: "Settings" category, decimal (in "mm")
Jumpers: Number of levels: Category "Settings", Integer
Number of cables...: Category "Settings", integer
Cable distance...: "Settings" category, decimal (in "mm")
Horizontal symbol distance: "Settings" category, decimal
Number of adjacent symbols: "Settings" category, integer "1-X"
Grid: "Settings " category, string (default: 4 mm)
Modification date (manual): "Revision" category, date
Version: "Revision" category, string
Company code: "Data" category, string, write-protected







EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 73/213

Dynamic Forms

Form in which the graphics can be changed (e.g., the number of lines: only those
are displayed which have data filled in, no empty ones), that is, the graphics are
adapted to the actual number of lines. In this kind of form, header, data, and footers
can also be determined within one page.


Check the form to be modified




































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 74/213






























Copy and paste in the same place, then rename to another form name, eg F04.f03
















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 75/213

Highlight the unwanted table, delete it.



















Click on the page, Open the page properties,(shift + D)
Go to properties and change the setting as follows:
1) Columns change to : 1 ( 1 column)
2) Horizontal symbols : 25 (cross-ref space)
3) Number of adjacent : 20 (component in a row)
4) Form handling : Dynamic (auto lines)




















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 76/213

Go to form and edit the properties of the forms

















Change the form accordingly .










EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 77/213















































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 78/213


Draw a normal lines








































From the Data area, Click the area that require repeated.



EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 79/213

Then close and proceed as below.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 80/213


5. Bus Topologies











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 81/213


6. Location Box

Adding Location Boxes

Everything inside a location box is allocated to a different DIN group from that which
is defined in the page properties. The components then have the same relationship
to the location box as they normally have to the page. This assumption of the DT
also occurs if only identifier blocks like installation and location are entered in a
component in the location box.

Insert > Box / connection point / mounting panel > Location box

Draw the rectangle representing the box.
































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 82/213

Enter the item data in the location box specific Properties dialog.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 83/213

In the Identifier tab, click [...] in the Full DT field.





























Accept the default for the DT or make new entries for the identifier blocks if
you would like to modify the structure.

Click [OK].












EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 84/213

Click OK













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 85/213


Specify the position for the new identifier in the Place identifiers dialog using
the buttons then click OK











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 86/213

7. Multi-User Access













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 87/213


8. User Rights Management


Managing Users

The rights management allows you to create users and assign them to particular
user groups. You can also subsequently edit or delete users.

Create users

Utilities > Rights management

To the left of the Rights management dialog, select the User folder, and click
[New].































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 88/213


In the User dialog, enter a name and short description of the new user.













You can assign a password in the Password field. To avoid typing errors on
entry, you must enter the password a second time into the Confirm password
field.

Click [OK].

Assign the user to one or more groups as described in the section "Editing
Users".























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 89/213


Edit users

Utilities > Rights management


To the left of the Rights management dialog, select the User folder.







































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 90/213


Select a (self-defined) user name in the right-hand field and click [Edit].



























In the User dialog, change the name, description and password and then click
[OK].















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 91/213

Delete users

Utilities > Rights management

To the left of the Rights management dialog, select the User folder.









































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 92/213

Select a (self-defined) user name in the right-hand field and click [Delete].













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 93/213


Assign users to groups

Utilities > Rights management

In the Rights management dialog, click the plus sign next to the User folder
to open the folder and select a user name.







































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 94/213

Select the check box corresponding to the user groups for which you wish the
user to be a member of.


Managing User Groups

The rights management allows you to create user groups and assign particular
editing rights to them. You can also subsequently edit or delete user groups.


Create user groups

Utilities > Rights management


To the left of the Rights Management dialog, select the Groups folder, and
click [New].





























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 95/213



In the Group dialog, enter a name and short description of the allowed editing
rights of the new user group.












Click [OK].


Assign editing rights to the group as described under "Editing user groups".


























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 96/213

Edit user groups

Utilities > Rights management

To the left of the Rights management dialog, select the Group folder.



























Select a (self-defined) user group in the right-hand field and click [Edit]. In the
Group dialog, change the name or description. Click [OK].












EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 97/213

Delete user groups

Utilities > Rights management

To the left of the Rights management dialog, select the Group folder. Select a
(self-defined) user group in the right-hand field and click [Delete].








































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 98/213


Assign editing rights to groups

in the Rights management dialog, click the plus sign next to the Group folder
to open the folder and select a user group.


























Select the check box in front of the user groups in which the current user is to
be a member. Click the plus sign to open the subordinate rights. Click [OK].













EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 99/213


Logging on or Changing Users

Log on users

The Logon dialog is automatically displayed when EPLAN starts.













Enter the user name and password and click [OK].


Switch users

Select the menu item Project > Switch user.

Enter the user name and password into the Logon dialog and click [OK].



















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 100/213


9. Revision Management

Completing Projects and Pages

In EPLAN, projects can be completed at any time. The project is then write-protected
and can no longer be changed. A completed project is stored in the project directory
with the extension *.elr.

Select the menu item Utilities > Revision control > Complete project.

Click [Yes] in the message window in order to use the comments on the
revision as the description for the page modification. (If you click [No], the
process will be canceled, and you can complete the pages manually).


Complete pages

Select the project or the modified pages in the page overview, and select the
menu item Utilities > Revision control > Complete pages.


























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 101/213


Generating Revisions

Utilities > Revision control > Generate revision

























In the Generate revision dialog, enter a name for the revision in the Revision
name field. In the Comment field you can enter a short description of the revision,
but the field may also be left blank. Click [OK].














EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 102/213

Generating Comparison Projects

Utilities > Revision control > Generate comparison project















In the Generate comparison project dialog, enter a name for the comparison
project in the Project name field.

In the Comment field you can enter a short description of the comparison
project, but the field may also be left blank.

Select the check box Generate temporary comparison project if you would
like to generate a non-write-protected project that you can delete again later.

Click [OK].


















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 103/213


Comparing Projects

Differences between two projects are registered by comparing particular properties
with one another. In the Compare projects dialog, you can determine which
projects will be compared. The properties to be compared are determined in the
Comparison settings dialog. If the value of the properties is identical for two
projects, then no difference is registered between them.


Select the desired project in the page navigator and select the menu item
Utilities > Revision control > Compare projects.

















In the Compare projects dialog, select the check box Show only associated
comparison projects.

In the list, select Compare with to select the comparison project you would
like to compare with the currently opened project.

In the Comparison settings field, select the scheme which determines the
settings for the comparison. (If you have not stored your own schemes, then
only the standard scheme will be offered here. In this case create a new
scheme by Specifying comparison settings.)

In the Text field, enter the text to be used to mark the revision changes in the
properties.

Click [OK].


EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 104/213


Removing Revision Markers

You can remove revision markers created via change tracking or a project
comparison from the project separately.

Utilities > Revision control > Delete revision markers


















In the Delete revision markers dialog, select which markers you would like to
delete: Check the corresponding check boxes. Click OK after you have done



















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 105/213


Removing Write Protection

Completed projects and comparison project are always write-protected. Only
temporary comparison projects are not write-protected. However, it is possible to
remove the write protection if necessary.

Utilities > Revision control > Remove write protection






































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 106/213


10. Translation

Setting Up Translation Database

Opening a Dictionary

As standard, EPLAN dictionaries are stored in the ..\Translation directory.
Select Utilities > Translation > Edit dictionary > Management tab.





































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 107/213


Click [...] next to the Dictionaries field.























Select the directory where the dictionary is located. Select the Microsoft Access-
Datenbanken (*.mdb) file type and then select the desired file.



















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 108/213


Creating a Dictionary

You can create and manage multiple dictionaries. Select the appropriate dictionary
for each of your projects.


Utilities > Translation > Edit dictionary > Management tab

Select [Extras] > New.




































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 109/213

To create a new database for the dictionary, enter a file name into the File
name field and select the Microsoft Access databases (*.mdb) file type.

Click [Save].





















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 110/213


Add dictionary language

In the Management tab, use [...] to select the dictionary to which you wish to
add a dictionary language.

Click (New) next to the Dictionary language field.







































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 111/213

One after the other, select all of the languages that should be available in the
dictionary.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 112/213


Delete dictionary language

In the Management tab, use [...] to select the dictionary from which you wish
to remove a dictionary language.




























Select a language in the Dictionary languages field.












EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 113/213

Click (Delete).













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 114/213

Language Translation

Utilities > Translation > Settings











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 115/213

In the project tabs, under display column, select new button













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 116/213















































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 117/213
































To export full sentences select the Translate whole sentences only check
box.

To export individual words deselect the Translate whole sentences only
check box.










EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 118/213

Exporting missing word













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 119/213

Create a file name, select the location where you want the files to be saved and click
Save






















Select the language files





















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 120/213


Importing Text Into Database

Once you have translate the output files,

Go to Utilities > Translation > Edit Dictionary








































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 121/213

Now, under management tab, go to Extra > Import













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 122/213

Select the translated files and click Open.






















Select the reference language






















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 123/213

Auto Correct / Auto Complete

AutoComplete:
If the check box is selected, words will be automatically completed while you type.
Utilities > Translation > Setting















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 124/213



Under User tab, In the Input column, select AutoComplete











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 125/213




AutoCorrect:
If the check box is selected, all of the words that you have specified in the AutoCorrect tab
will be replaced in the first display language by their replacement text.
Utilities > Translation > Setting













EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 126/213



Under User tab, In the Input column, select AutoCorrect.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 127/213


11. Advance Setting

In the Settings dialog, you can view and edit all settings for the Project, User,
Workstation, or Company categories.

Project Setting







































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 128/213


12. System Messages

Calling up System Messages

When you open a project, the System messages dialog lists errors which occur
during the program run in the currently opened project.

You can open the system messages at any time, even when no project is currently
open.

Utilities > System messages.


































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 129/213















































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 130/213


Storing System Messages

You can save the displayed system messages as a text file. You define the directory
for the file in the workstation settings. The file name EplLog.txt is predefined by
the program.

Select the menu item Utilities > System messages.






































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 131/213


Click [Save] in the dialog.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 132/213


13. Change Of Standard

Replacing Symbol Libraries and Symbols - Changing Standards

You can replace basic symbol libraries, symbol libraries, and individual symbols. The
basic symbol library contains the symbols for the basic symbol preview. When
exchanging the basic symbol libraries and symbol libraries, the source data is saved
in the target project. Individual symbols are replaced there.

Utilities > Change of standard > Project tab > [Next] > Rotation / mirroring
tab > [Next]

Assign target symbol libraries

In the Master data tab in the Name column select the symbol library to be
replaced.





























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 133/213

Within the same row, click [...] in the New name column.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 134/213

In the Select Symbol Library dialog, select the symbol library to be used for
the target project and click [Open].












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 135/213

To assign the entire symbol library click [Next] in the Master data tab and do
the same in the Symbols tab.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 136/213

To assign the source symbol library symbols to the target symbol library
symbols, select the Individual assignment check box in the Master data tab
and click [Next].











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 137/213

In the Symbols tab in the Scheme column select an assignment scheme.

Click [Next].











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 138/213




14. Single Line Diagram / Overview

Drawing Schematics in Single-line Representation
For the single-line display of schematics, you can use pages with a special page
type. The placed symbols are connected together via autoconnecting. Using a
connection definition point, you can display the number of conductors in the cable.

You have opened a project.

Page > New

































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 139/213


In the New page dialog, select Schematic single-line from the drop-down list
in the Page type field.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 140/213

Place the symbol

Select Insert > Symbol.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 141/213

Select the desired symbol from the Symbol selection dialog then press OK



























Place the symbol on the page in the graphical editor.

















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 142/213

Place the connection definition point

Select Insert > Connection definition point.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 143/213

Place the connection definition point on the auto connection line between
the desired symbols in the graphical editor.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 144/213

In the Properties <...> dialog, in the Connection definition point tab, enter
the desired data then click OK












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 145/213

Synchronizing Data between Single-Line and Multi-Line Displays

If you make a change to a multi-line object or a single-line object belonging to one,
you can synchronize the objects with one another. You can be sure in this way that
the change has been transferred to the matching counterpart object.


1. Select the desired object.

2. Select the menu item Utilities > Synchronization and, for a multi-line object
select Multi-line --> single-line and overview, for a single-line object select
Single-line --> multi-line and overview and for an object in the overview,
select Overview--> multi-line and single-line.

































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 146/213

Generating Connection

To number the connection

Project data > Connections > Numbering > Place



















Choose the type of setting.





















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 147/213


Project Data > Connections > Numbering > Enter Designation


















Press OK

























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 148/213















































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 149/213


Connection Setting

Settings for connection numbering are saved in schemes. This way you can access
previously specified settings at any time and even change them, if necessary.

Project data > Connections > Numbering > Settings

In the Settings: Connection numbering dialog, select a user-defined
scheme from the drop-down list, or create a new scheme using (New).




































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 150/213


In the Filter tab select the check box for the trade and connection type you
want to number. In the Placement tab select where and how often you want to place
the connection definition points on the connections.










































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 151/213


In the Designation tab, define the format groups that are to be formatted
together.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 152/213


In the Display tab specify formatting for connection designations generated on
the connection definition point. Among these formatting options are, for
example, horizontal and vertical increments of the connection designation from
the connection line, as well as text color, size, etc. Click OK after you have done.









































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 153/213


Creating Format Groups

Project data > Connections > Numbering > Settings

In the Settings: Connection numbering dialog, select a user-defined
scheme from the drop-down list, or create a new scheme using (New).







































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 154/213

Move the Designation tab to the foreground and in the toolbar above the
Format groups field, click (New).












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 155/213

In the Connection numbering: Formats dialog, in the Connection group
field, select one of the predefined connection groups or the "Browse..." entry.
































If you selected "Browse..." and opened the Device tag list dialog, select one
of the DT's in the project and click [OK].

In the Extent field specify the range of connections that are to receive the
same format for their connection designations. Select an entry from the dropdown
list.

In the Available format elements field select a format element and move it
over to the right using the arrow button into the list of selected format
elements.


EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 156/213

Define the formatting in the subsequent dialog. If desired, you can change the
sequence of the formatting elements using the arrow buttons. Click [OK] when you
have done with the setting.


15. Managing Master Data


Managing Master Data
Master data files to be edited or stored in the project can be opened in the standard
dialog, which is in a default directory. You can specify settings for this via Options >
Settings > User > Management > Directories.
Actual storage and management depends on the type of master data in question, in
which the program distinguishes between the management of:
Parts data
Forms
Plot frames
Macros
Symbol libraries.
If the specified form / plot frame is not in the master data pool, it can be found using
the Complete project function and can even be automatically stored. If missing
master data can't be found in the master data pool, a message is displayed.
























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 157/213

Defining Master Data Directories

Options > Settings > User > Management > Directories
The paths to the required databases and files are defined in the defaults for
directories when selecting or editing master data. This information is used by certain
program elements and functions when particular data is required. The settings are
user dependent in order for you to manage and organize your own pool of master
data.

1. In the Projects field of the Settings: Directories dialog, click [...].


























In the Browse for Folder dialog select the desired drive and directory. Click [OK].
Proceed this way for all further master data types with default directories that
you would like to change. (The default after installing EPLAN is
<Drive_EPLAN>:\<Programs folder>\<Master data type>\<Company
code>. Click [OK].





EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 158/213

Master Data: Managing Parts Data

In addition to the general parts database there is a project-related Parts project
database, in which the parts data used in the project are managed separately. Data
for a part is taken from the internal parts database and transferred to the project for
each part, even if only the part number is stored on the component in the graphical
editing at the time the part is selected.

Project data can be synchronized later in both directions with the system master
data. Furthermore, certain stored parts properties can be removed from the project.

Synchronize project data with master data

1. Open the project whose master data is to be synchronized.






























2. Select Utilities > Parts > Current project --> parts database.

EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 159/213

Synchronize master data with project data

1. Open the project whose master data is to be synchronized.






























Select Utilities > Parts > Parts database --> current project.












EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 160/213

Delete stored part properties

1. Open the project whose master data is to be synchronized.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 161/213

Select Utilities > Parts > Delete stored properties.



















In the Delete stored parts properties dialog, select the Delete check box for
each part property that you would like to delete from the part stored in the
project. Click [OK].



EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 162/213

Master Data: Managing Forms

Forms are edited as individual files and added individually to the project as soon as
they are used in the project. This means: As soon as a form is selected for use in a
project (e.g. on a page) the selected form if it does not already exist in the project
it is automatically stored. An original form is not deleted from the project when
another form is selected, but rather it remains embedded even if it is no longer used.

If the selected form is not in the master data pool it can be found via the menu item
Utilities > Master data > Complete current project and, if necessary,
automatically corrected. If missing master data cannot be found in the master data
pool, then an appropriate message is displayed.

Store form in project

Select Utilities > Master data > Form > Open.






























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 163/213


Select the form to be edited in the Open forms dialog.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 164/213

In the page navigator, select the page to which you would like to assign the
form.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 165/213

Select Popup menu > Properties.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 166/213


If the Form name property is not yet in the list of properties, click (New)
next to the Category field in the Properties group box of the Page properties
dialog.










































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 167/213

In the Property selection dialog select the Form name property. Then press OK













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 168/213

Open the drop-down list in the Value field for the Form name property.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 169/213

Click [Browse]. Select the changed form in the Select form dialog then pressed
Open. Press OK after you have done with the setting.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 170/213

If required, you can change the values of the other properties of the page. Click [OK]
after you have done with the setting.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 171/213


Form master data is referenced as follows:
All forms used on pages
All forms stored in the settings for reports (Options > Settings > Projects >
"Project name" > Reports > Graphical output)
All forms saved in the following function types: mounting panel objects,
terminal and plug definition texts, cables
Placed forms (e.g. enclosure legends).


Master Data: Managing Plot Frames

Plot frames are edited as individual files and added individually to the project as
soon as they are used in the project. This means: As soon as a plot frame is
selected for use in a project (e.g. on a page) if it does not already exist in the
project it is automatically stored. An original plot frame is not deleted from the
project when another plot frame is selected, but rather it remains embedded even if
it is no longer used.

If the selected form is not in the master data pool, it can be found via the menu item
Utilities > Master data > Complete current project and, if necessary,
automatically
corrected. If missing master data cannot be found in the master data pool, then an
appropriate message is displayed.

Store plot frame in project

Select Utilities > Master data > Plot frame > Open.


















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 172/213


Select the plot frame to be edited in the Plot frame selection dialog. Click Open






















In the page navigator, select the page to which you would like to assign the
plot frame.




















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 173/213

Select Popup menu > Properties.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 174/213

If the Plot frame name property is not yet in the list of properties, click
(New) next to the Category field in the Properties group box of the Page
properties dialog.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 175/213

In the Property selection dialog select the Plot frame name property. Click OK
after you have done.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 176/213

Open the drop-down list in the Value field for the Plot frame name property.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 177/213

Click [Browse]. Select the changed plot frame in the Select plot frame dialog. After
you have selected the frame, click Open. Select OK after you have done with the
setting.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 178/213

Master Data: Managing Macros

Macros are broken up in the project as soon as they are inserted. Data is then
undistinguishable from manually inserted individual elements. All data in a macro are
referenced when stored (except foreign language texts).

The name of the symbol library from which the macro was generated (drawn) is
stored in the macro. This way the macro preview will use the correct symbol library
for the display.

In the operating system layer, macros are individual files that can be sent to end
customers, for example.

Master Data: Managing Symbol Libraries
Symbols are compiled, edited, and managed in symbol libraries. The project settings
(inherited by symbols, e.g. line thickness of the symbol) for the current project are
used in managing the symbol libraries.

Symbol selection (Insert > Symbol) only displays those symbols from the stored
symbol libraries and symbol libraries are identified by name (without the path) in
projects.


Store symbol libraries (copy to the project)
Symbol libraries are added to the project as soon as they are entered into the project
settings, or they are opened or generated in the project.

Options > Settings > Projects > "Project name" > Management > Symbol
Libraries

1. In the Settings: Symbol libraries dialog, click [...] in a column below Symbol
libraries.

2. In the Select symbol library dialog select the new symbol library.

3. Click on [Open].

4. If you have clicked [...] in the column of an already assigned symbol library,
EPLAN checks whether the original symbol library and the newly selected one
are both compatible. If this is not the case, the process will be interrupted with
a prompt. If the two symbol libraries are compatible, you have to confirm the
exchange in the Exchange symbol libraries dialog. Click [Yes].




EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 179/213

5. If you have clicked [...] in an empty column, the storage process is
automatically started.

6. Select the Synchronize check box if the symbol library should be managed on
a project basis.

7. If necessary, change the preceding sign (the default is the first letter of the
symbol library) so that you can differentiate between the symbol libraries in the
list view in the Symbol selection if you select Popup menu > Name with
preceding sign.

8. Proceed this way for all of the further symbol libraries that you would like to
store in the project.

9. Click [OK].


File off symbol libraries (delete from the project)
Before deleting a symbol library from the settings, and therefore from the project, the
library is checked for symbols that are still used in the project. It is possible to delete
if the symbol library is not being used.

Options > Settings > Projects > "Project name" > Management > Symbol
libraries

1. In the Settings: Symbol libraries dialog, select the symbol library that you
would like to delete from the project.



















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 180/213

Click (Delete). If symbols from the selected symbol library are still being used in
the project, click [OK] to confirm the prompt.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 181/213

Master Data: Defining Form Settings

Master data is stored on a project-related basis and can be synchronized with the
master data pool when opening, saving, or restoring the project. There are project
settings especially for forms, which you can specify as follows:

Options > Settings > Projects > "Project name" > Reports > Output to page

1. In the Settings: Output to page dialog, open the Form drop-down list for the
reporting type whose settings you would like to edit.




































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 182/213

Click [Browse].


























3. Select the desired form in the Select form dialog. Only the data type
appropriate to the currently selected report type will be displayed under Files
of type.

4. Select the Preview check box in order to display the graphic for the form that
is selected in the list.

5. Click [Open].

6. Select the Project related check box if the form should be managed on a
project basis..








EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 183/213

7. Specify additional settings for the form.



























8. Click [OK].

















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 184/213

Synchronizing Master Data

The master data (e.g. a symbol library) is not referenced, but rather stored in the
project, i.e. copied into the project. The storage of the master data being used thus
occurs within the Project. Depending on the project settings specified under Options
> Settings > Projects > "Project name" > Management > General, Options >
Settings > Projects > "Project name" > Management > Symbol libraries, and
Options > Settings > Projects > "Project name" > Reports > Display / output
you can, if necessary, manually start the synchronization of project master data with
the system-specific data.

Synchronize individual master data objects
Preconditions:
You have opened the project whose master data is to be synchronized.
You have no editor open for working on master data (Plot frame editor, Form
editor, etc.).
Utilities > Master data > Synchronize current project





























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 185/213


1. In the Synchronization of master data <Project name> dialog click the
column heading in the tables in order to sort the data alphanumerically either
ascending or descending by column. For example, if you click the column
Type, all entries will be sorted and displayed according to the Master data
type.








































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 186/213

2. In the Project master data list select the master data objects that you would
like to transfer to the system master data. (Multiple selection is possible.)












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 187/213


3. Click .












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 188/213


4. In the System master data list select the master data objects that you would
like to transfer to the project master data. (Multiple selection is possible.)











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 189/213


5. Click . Click [Close] after you have done with the setting.












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 190/213

Globally synchronize master data

Utilities > Master data > Synchronize current project

























1. In the Synchronization of master data <Project name> dialog select
[Update] > Project in order to globally replace all outdated project master
data with newer system master data.















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 191/213


2. Select [Update] > System to globally replace all outdated system master data
with newer project master data.








3. Click [Close].


































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 192/213


16. Numbering Devices

Numbering Using PLC data

Options > Settings > Projects > "Project name" > Devices > Number using PLC
data







































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 193/213





























1. In the dialog Settings: Number using PLC data select a user-defined
scheme from the drop-down list, or create a new scheme using (New).

2. In the Settings: Number using PLC data dialog, click (New) above the
Format groups field.

3. In the Number using PLC data: Format dialog, select the group of devices
from the Group drop-down list for which you want to determine the format.
You can choose between terminals, pins, and devices.

4. In the Extent drop-down list, select the scope of numbering for the selected
group.

5. In the Available format elements field select a format element and move it
over to the right using into the list of selected format elements.


EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 194/213

6. Define the formatting in the subsequent dialog.

7. If desired, you can change the sequence of the formatting elements using the
arrow buttons.

8. Click [OK].


Numbering Online

The online numbering format applies to devices that you newly place in the
schematic using the menu item Insert > Symbol. It also applies to copied devices
and devices in newly inserted macros.

You have opened a project.

Options > Settings > Projects > "Project name" > Devices > Numbering (online)
1. In the Settings: Numbering (online) dialog, click [...] next to the Numbering
format field.



























EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 195/213

2. To create a numbering format click (New) next to the Scheme field.




























3. Enter a descriptive name into the Name field and click [OK].



EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 196/213


4. Change to the DT tab.





























5. To allow all devices in the "General DT" device group to be numbered online,
select the General DT check box.


6. Click [...] next to the General DT field.










EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 197/213


7. In the Available format elements field of the DT format dialog, select the
"Counter" format element and click (Move right).





























8. In the Format dialog, in the Minimum number of digits field, enter the
number of positions to be used for the DT counter and click [OK].

9. Select all of the desired format elements sequentially. Pay attention to the
rules for the Online numbering format.

10. Click [OK].

11. To define the online numbering for all other device groups and connections,
proceed in the same manner in the DT and Connection Points tabs.




EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 198/213


12. Click (Save) and then click [OK].












































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 199/213

Setting Preceding Signs in Displayed DT

The displayed DT can be displayed with a prefix, e.g. -M1 or without a prefix e.g. M1.
Click [OK].










































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 200/213

Numbering Devices Online

When you insert new devices into the schematic then you can define that these
devices are to be automatically numbered.

A DT is determined and assigned online for every device that you insert. The
counter for DT is incremented by one in the process.

Options > Settings > Projects > "Project name" > Devices > Numbering (online)





































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 201/213

Click [OK].













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 202/213

Number online and set flags

1. In the dialog Settings: Numbering (online) dialog, in the On insertion of
symbols group box, select the Number with flag "?" option. Click [OK].




















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 203/213

Not Numbering Devices Online
When you insert new devices into the schematic then you can define that these
devices are not to be automatically numbered.

Options > Settings > Projects > "Project name" > Devices > Numbering (online)









































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 204/213

Exclude device groups from numbering
Devices that are excluded from the numbering are allocated an identifier and a
counter. The counter is not incremented.

1. In the Settings: Numbering (online) dialog, click [...] next to the Numbering
format field.








































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 205/213

2. Select a user defined scheme from the Schemes field.













































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 206/213

3. Change to the DT tab.




























Deselect the check box for each device group that is not to be numbered
online.

Click (Save) and then click [OK].













EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 207/213

Insert devices without a DT
A device can be inserted without a DT. In this case, the entries for the displayed and
full DT remain empty.

1. In the dialog Settings: Numbering (online) dialog, in the On insertion of
symbols group box, select the Empty field option. Click [OK] when you have
done.

















EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 208/213

Numbering the Devices Offline

You can number devices in the page navigator, the device navigator, or the
graphical editor. Which option you choose depends on which scope of numbering
you need.

1. Select a project, pages, functions, or structure identifier layers.







































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 209/213

Specify offline numbering

Project data > Devices > Number.











































EPLAN ELECTRIC P8 Basic Training
Sysnet Controls Sdn. Bhd. Page 210/213

In the Format column of the Number (offline) dialog, select a numbering
format. Select the Preview of result check box. Click [OK].

To accept the DT numbering, click [OK].

You might also like