You are on page 1of 119

ZXMP S330(V1.

41)
System Introduction (completed)
V1.0
Course objective
Master functions and features of ZXMP S330
Master hardware structure of ZXMP S330

Outline
Product Overview
System Features
System Structure
Boards Information
ZXMP S330 Overview
ZTE SDH based multi-service node equipment provides all applications at the core
layer, convergence layer and access layer, and provides users with future-oriented
integrated MAN solutions.
As an SDH integrated service transmission equipment at the highest rate level of
STM-16, ZXMP S330 has not only generic features of the SDH transmission products,
but also powerful data service access capabilities. It can transmit TDM and DATA
traffic with small or medium capacity, be applicable to the construction and capacity
expansion of various transmission networks.
ZXMP S330 features a compact size, powerful functions, and flexible usage. It is
mainly applicable to LAN and MAN (at the access layer and convergence layer).

Core
Layer
Aggregation
Layer
Access Layer
ZXMP S325
ZXMP S320
ZXMP S385
ZXMP
ZXMP S380
ZXMP S390
S330
ZXMP S310
ZXMP S385
ZXMP S380
ZXMP S200
ZXMP S100
ZXMP S330
ZXMP S330 Product Highlight
ZXMP S330
Product
Highlight
Cross-connection capacity 20G,
provide service grooming;
12 service slots, accommodate
multiple rings and chains.
Support various services such
as PDH,SDH,FE/GE, ATM,etc.;
Embedded RPR promote IP
processing ability;
Control,Cross-connection,Clock,
and Line cards dispersed
configuration;
TPS protection can have 4
groups maximumlly.
Single-Fiber Bidirectional
solution help to save fiber
resource;
Colored optical interface help to
save invest in WDM and reduce
OPEX.
Powerful networking ability Service access ability
High reliability Flexibility & Convenience
Outline
Product Overview
System Features
System Structure
Boards Information
ZXMP S330 System Structure
Cross-Connection
Clock
Cross-Connection
Clock
STM-N
STM-N
STM-N
STM-N
NE
Control
Processing
Overhead
& Auxiliary
NE
Control
Processing
PDH
Interface
SDH
Interface
ATM
Interface
Ethernet
Interface
ZXMP S330 System Features
Small Size, Compactness, and Flexible Usage
ZXMP S330 features a small size and high integration. It can be
placed inside a standard 19-inch cabinet.
ZXMP S330 provides 12 slots for service boards. Among which, slot
5, 6, 11, 12 can hold any service board.

Good Electromagnetic Compatibility (EMC) and
Operation Safety
EMC, operation safety, and fire/explosion protection are fully
considered in the circuit board design, device selection, structure
design, and equipment labeling design for ZXMP S330.
ZXMP S330 is provided with standard labels, good EMC, and
reliable safety performance.
ZXMP S330 System Features
Powerful Service Access Capability
ZXMP S330 employs a modular structure. Its hardware contains the CS
board, clock board, NE control board, service boards, and service interface
boards. By combining different boards, the equipment can configure
different functions.
ZXMP S330 provides flexible traffic add/drop modes.
ZXMP S330 provides optical interfaces at the rate level of STM-16, STM-4,
and STM-1; electrical interfaces such as E1/T1, E3/T3, and STM-1; as well
as Ethernet/ATM data interfaces. The interface types and corresponding
maximum access capacities are listed in the Table:
Service
Type
Number of Interfaces
Per Board
Maximum Access
Capacity per Subrack
Service
Type
Number of Interfaces
Per Board
Maximum Access
Capacity per Subrack
STM-16 1 4 T1 21 252
STM-4 123 or 4 20 FE/o 24 or 8 96(56)
STM-1/o 123 or 4 40 FE/e 4 or 6 7248
STM-1/e 1 or 2 24 GE/o 2 24(8)
E3 3 36 GE/e 2 24(8)
T3 3 36 ATM 4 48(40)
E1 21 252
Diverse Optical Interfaces
The OL16 board of ZXMP S330 provides colorful optical interface,
which facilitates ZXMP S330 to directly connect with the mux/demux
unit of WDM equipment. In this way, the optical wavelength
conversion unit can be omitted and the cost can be reduced.
The OL1/4 board of ZXMP S330 supports single-fiber bidirectional
application. This application can simultaneously receive and transmit
optical signal in a single fiber, so as to save optical fibers.
ZXMP S330 provides the optical module verification function, which
detects whether the optical module in the equipment passes
verification. If not, service will become abnormal, the EMS will report
alarm. Only the optical module that has passed verification can work
normally. The optical module verification function prevents service
fault caused by the optical module that is not strictly tested.

ZXMP S330 System Features
Powerful Service Cross-Connect and Expansion
Capabilities
ZXMP S330 supports service co-working in a variety of directions.
The higher-order cross-connect capability is 128 128 VC4;
The lower-order cross-connect capability is 20162016 TU-12;
The access capacity is 88 x 88 VC-4.
ZXMP S330 can also be used as an expansion subrack of the
ZXMP S390, ZXMP S380, or ZXMP S385.
ZXMP S330 System Features
Perfect Equipment and Network Protection
Capabilities
Equipment protections
The key boards in the system are under the 1+1 redundancy
protection, such as clock boards (SC) and CSB boards.
The service boards are under the 1:N (N5) redundancy
protection.
ZXMP S330 adopts the dual power supply system. Each
functional board is fed in the distributed power supply mode.
This eliminates the power supply influence of one board upon
another, and greatly reduces the impact of board hot-plug in
the system.
ZXMP S330 System Features
Perfect Equipment and Network Protection
Capabilities
Network protections
MS chain protection;
2-fiber unidirectional/bidirectional path protection ring;
2-fiber bidirectional MS protection ring with or without extra
traffic;
STM-4/16 4-fiber bidirectional MS protection ring;
Dual Node Interconnection (DNI) protection;
Subnet Connection Protection (SNCP).
ZXMP S330 System Features
Reliable Timing and Synchronization Capability
ZXMP S330 provides 4 external reference clock outputs and 4 external
reference clock inputs;
The external reference clock interfaces are provided by the clock
interface (SCI-75 or SCI-120) board, which is independent of the SC
board;
The system allows setting 8 clock sources at the same time. The
primary timing reference can come from any line (or tributary), 2 MHz
interface, or 2Mbit interface;
The phase-locked loop is controlled by software;
The equipment supports the tributary re-timing for 2M service;
The equipment supports the synchronous priority switching and the
automatic switching based on SSM algorithm, which optimizes time
synchronization distribution in the network, reduces difficulty in
synchronization planning, prevents timing loops, and keeps the
network synchronization in an optimal status.
ZXMP S330 System Features
Highly Reliable and Easy for Maintenance and
Upgrade
Online download and remote upgrade of the board software allow
the upgrade to be intelligent, easy, and practical. During upgrade,
the system will give warning for possible service interruption, so
as to prevent misloading.
Upgrade and re-configuration of the system are reversible, thus
enhances the security of upgrade. The system can recover the
original services in the case of upgrade failure, without affecting
normal operation of services.
ZXMP S330 System Features
ZXMP
.
Remote software download,
easier for maintenance and upgrade
ECC ECC ECC
ZXMP ZXMP ZXMP
Highly Reliable and Easy for Maintenance and
Upgrade
Routine maintenance allows quick fault locating to board.
Critical boards that generate much heat are provided with the
temperature detect function.
The EMS, NCP software, and board software are independent of
each other, so that their upgrades will not affect others.
The EMS is independent of the board software version. This avoids frequent
network-wide upgrade and reduces workload and difficulty of upgrade.
When one software application is upgraded, there is no need to perform a
network-wide software upgrade due to software mismatch.
There is no need to perform upgrade of whole software set due to a single
module fault. The system upgrades itself in a modular way to the least extent.


ZXMP S330 System Features
Outline
Product Overview
System Features
System Structure
Boards Information
300mm(Depth) x 600mm(Width) x 2600mm(Height)
300mm(Depth) x 600mm(Width) x 2200mm(Height)
300mm(Depth) x 600mm(Width) x 2000mm(Height)
Cabinet Structure
Indicator

Name Status
On Off
Red Major Alarm
Indicator
Critical or major alarm,
accompany by sounds
alarm
No critical or major alarm
Yellow Minor Alarm
Indicator
Minor alarm No minor alarm
Green Power Status
Indicator
Power supply normal Power supply abnormal
Structure Parts

Structure Parts include:
Power Distribution Box
Subrack
Board Area
Backplane
Fan Plug-in Box
Dustproof Unit





Power
Distribution
Box
Dustproof Unit
Board Area
Backplane
Fan Plug-in Box
Power Distribution Box
Power distribution box receives external input of active/standby power
supply.
Power distribution box can allocate at most six pairs of active/standby
power supplies to the subracks, after filtering and lightning protection for
the external power supply.
A standard power distribution box can allocate four pairs of
active/standby power supplies to the subracks.

1. Mounting flange
2. Captive fastener
3. Subrack active power supply area
4. Connection terminal of external power input
5. Subrack standby power supply area
6. Alarm indicator board (LED)
7. Front panel
Subrack
The height of subrack is 10U.One to three subracks
can be configured in a 2000mm or 2200mm cabinet,
and one to four subracks in 2600mm cabinet.
User can fix subrack in the cabinet from the front.
The installation mode can meet the requirements of
maintenance from the equipment front, cabinet
installation against wall, and back-to-back
installation.
Subrack
S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
C
I


P
W
R

P
W
R

A
l
a
r
m

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

S
e
r
v
i
c
e

I
n
t
e
r
f
a
c
e

N
C
P
I


2
V
C
4

2
V
C
4

4
V
C
4

4
V
C
4

1
6
V
C
4

1
6
V
C
4

S
C

S
C

C
S
B

C
S
B

1
6
V
C
4

1
6
V
C
4

4
V
C
4

4
V
C
4

2
V
C
4

2
V
C
4


N
C
P


Fan Plug-in Box
Board Area
The board area has two layers, 17 slots in each layer;
Functional/service interface boards shall be plugged in the upper layer;
Except for the PWR board, functional/service boards shall be plugged in the
lower layer;
Subrack size:
443.7(Height)482.6(Width)270mm(Depth)
Subrack
Backplane
S330 backplane size is 432 mm (length)322 mm (width)4 mm
(thickness)
Backplane communicates with the ZXMP S330 boards, and
external signals via interfaces and sockets.
There are service bus, overhead bus, clock bus, board-in-
position bus on the Backplane.
There are tin bands serving as ground cables in the front and
rear of the motherboard where the motherboard contacts the
subrack, to ensure electrical connection between subrack and
motherboard.
The sockets and interfaces of motherboard can be divided into
the upper layer and the lower layer.
Functional/service interface boards are connected to the upper
layer sockets.
Functional/service boards are connected to the lower layer
sockets.
Subrack
Sockets and Interfaces
1Service interface board socket 2Service board socket
3SC board socket 4CS board socket 5NCP board socket
6NCPI board socket 715 A black connector terminal
8Indicator board alarm interface 9Power supply interface
10Power alarm interface 11SCI board socket
Subrack
Fan Plug-in Box
A fan plug-in box consists of one fan motherboard and
three independent fan boxes arranged side by side.
Fan box has electrical connection to the fan
motherboard through the socket at the box rear side.
Fan box has independent locking function, with
running and alarm indicators on its front panel
1. Mounting bracket 2. Fan box 1. Fan box 2. Fan 3. Indicator 4. Button switch
Subrack
Fan plug-in box
Fan plug-in box dissipates heat and cools the ZXMP S330 equipment. It consists
of one fan motherboard (FMB) and three independent fan boxes arranged sid by
side. Each subrack is configured with one fan plug-in box.
Controlled by the NCP board, the FAN board provides three levels of wind speed,
i.e., fast, slow and stop. It provides the NCP board with the running blocked
signal for monitoring. If a FAN board fails to communicate with the NCP board, it
will control the fan to run at the fast level.
Fan Motherboard (FMB)
Fan Board
NCP Subrack Motherboard (MB)
Fan Board Fan Board
Subrack
Dustproof Unit
A brand-new dustproof design adapts to ZXMP S330 to abandon the separate
dustproof plug-in box.
The pull-push operation mode makes periodic cleaning convenient.
Cleaning label appears on the front panel in addition.
The dustproof unit is installed under the fan plug-in box. It filters air and prevents
dusts from entering the subrack, to ensure subracks electrical performance.
1. Air filter 2. Front panel 3. Cleaning label
Outline
Product Overview
System Features
System Structure
Boards Information
ZXMP S330 Boards List
No. Name Meaning
1 MB Mother Board
2 CSB Cross-Switch type B
3 SC Synchronous Clock
4 SCI-75 Synchronous Clock Interface75
5 SCI-120 Synchronous Clock Interface120
6 NCP Net Control Processor
7 NCPI Net Control Processor Interface
8 PWR Power
9 OL16X1 Optical Line STM-16
10 OL1/4X4 Optical Line STM-1/44
11 LP1x1 Line Process STM-1
12 LP1x2 Line Process STM-12
13 LP4X1 Line Process STM-4
14 LP4X2 Line Process STM-42
ZXMP S330 Board List
No. Name Meaning
15 OIS1x1 Optical Interface of STM-11
16 OIS1x2 Optical Interface of STM-12
17 OIS1x4 Optical Interface of STM-14
18 OIS1x6 Optical Interface of STM-16
19 OIS4x1 Optical Interface of STM-41
20 OIS4x2 Optical Interface of STM-42
21 BIS1 Bridge Interface of STM-1
22 ESS1x2 Electrical Switching of STM-12
23 EPE1x2175 Electrical Process of E121 75
24 EPE1x21120 Electrical Process of E121 120
25 EPT1x21100 Electrical Process of T121 100
26 EPE1B Electrical Process of E1/T121
27 BIE1x21 Bridge Interface of E1/T1
28 ESE1x21 75 Electrical Switching of E121 75
29 ESE1x21 120 Electrical Switching of E1/T121120 /100
ZXMP S330 Board List
No. Name Meaning
30 EPE3x3 Electrical Process of E33
31 EPT3x3 Electrical Process of T33
32 EP3x3 Electrical Process of E3/T33
33 BIE3x3 Bridge Interface of E3/T33
34 ESE3x3 Electrical Switching of E3/T33
35 SFEx6 Smart Fast Ethernet
36 SED Enhanced Smart Ethernet
37 EIFEx4 Electrical Interface of Smart Fast Ethernet
38 EIFEx6
39 BIFE Bridge Interface of Fast Ethernet
40 AP1x4 ATM Processor with 4 STM-1 port
41 OA Optical Amplifier
42 RSEB Ethernet Processor with RPR Function
43 FAN FAN board
44 FMB Fan Mother Board
ZXMP S330 Subsystems
No. Unit and Subsystem Boards Involved
1 Power Subsystem PWR
2 Synchronous Clock Subsystem SCSCI
3 NE Control&Processing Subsystem NCPNCPI
4 Cross Connection Subsystem CSACSB
5 Optical Line Subsystem OL16x1, OL1/4x4, LP1x1LP1x2LP4x1LP4x2
OIS1x1OIS1x2OIS4x1OIS4x2ESS1x2BIS1
6 EP1 Subsystem EPE1x21EPT1x21EPE1BESE1x21BIE1x21
7 EP3 Subsystem EPE3x3EPT3x3EP3x3ESE3x3BIE3x3
8 EOS Subsystem SFEx6EIFEx4OIS1x4BIFE
9 ATM Subsystem AP1x4OIS1x4
10 RPR Subsystem RSEBOIS1x4EIFE4
Power Subsystem
PWR
The power distribution box outputs the -48 V power supply to PWR board via air switch.
PWR board filters out EMI and ripples using filter circuit, and then supplies the power to
subrack.
Supports 1+1 hot backup.
Can prevent reverse connection of power supply
Detects over/under-voltage and board-in-position signals.
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Power input interface
Power Subsystem
PWR interface
Power input interface uses a D-type connector with three
jacks. The signals of these jacks from top to bottom are:
-48V GND
PGND
-48V
-48V GND is connected to the -48V GND busbar of
power distribution box;
PGND is connected to the copper busbar at the side of
cabinet;
-48V is connected to the output terminal of air switch.
Synchronous Clock Subsystem
The SC unit is the timing unit of ZXMP S330 , It comprises SC
boards and SCI board.
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CSB
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CSB
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
SC board functions
Provides system clock signals and system frame head signals for all
the units of ZXMP S330.
Employs the software-controlled phase-locking circuit to achieve four
working modes as follows:
Fast capture mode
Tracing mode
Hold mode
Free-oscillation mode
Supports eight clock sources simultaneously. The timing reference
can come from any line or tributary, 2 MHz, or 2 Mbit/s interfaces.
Selects a timing reference for the NE from the effective timing
sources, and allocates it to other units in the NE.
Performs protection switching among reference sources based on
the alarm of reference source and the synchronization status.
Implements network-wide clock synchronization.
SC board supports hot standby mode.
SC board functional blocks
Timing
reference
selection unit
Control unit
Clock
generation and
allocation unit
Switching control unit
Board
Line/tributary clock inputs
2.048 MHz
2.048 Mbit/s
Power supply unit
External clock
output unit
SCI board
SCI board
SCI board
SC board front panel
There are three indicators on the front panel, which are in turn the RUN
(green) indicator, the M/S (green) indicator, and the ALM (red) indicator
from top to bottom.
RUN Status ALM Status Meaning
Flickers( once/second) Constantly off Running normally
Flickers( once/second) Constantly on
Fault or alarm occurs
during running
Flickers( once/second) Flickers( once/second)
Constantly on Flickers( 5 times/second)
Constantly on Flickers( once/second)
Flickers( 5 times/second) Flickers( 5 times/second)
Flickers( 5 times/second) Flickers( once/second)
Flickers( 5 times/second) Constantly on
M/S Status Meaning
Flickers( 5 times /second) Fast capture
Flickers( once /second) Tracing mode
Flickers( 0.5 times /second) Free-oscillation mode
Constantly on Hold mode
Constantly off Standby mode
SCI board functions
SCI board provides SC board with four channels of external
reference clock outputs, and four channels of external reference
clock inputs.
ZXMP S330 supports two kinds of SCI boards:
SCI-75 is a 75 SCI board. It provides two channels of 2.048 Mbit/s and 2.048
MHz coaxial 75 receiving/transmitting interfaces (led out via 8 coaxial
connectors). The first channel of 2.048 Mbit/s output and that of 2.048 MHz
output originate from the same clock source, while the second channel of 2.048
Mbit/s output and that of 2.048 MHz output originate from the same clock source.
SCI-120 is a 120 SCI board. It provides two channels of 2.048 Mbit/s and 2.048
MHz 120 RJ11l receiving/transmitting interfaces (led out via eight RJ11
connectors). The first channel of 2.048 Mbit/s output and that of 2.048 MHz
output originate from the same clock source, while the second channel of 2.048
Mbit/s output and that of 2.048 MHz output originate from the same clock source.
SCI board working principle
At the external clock input side:
SCI board sends the received 2.048 Mbit/s and 2.048
MHz clock
signals to the motherboard, and the motherboard
sends the clock
signals to SC board for processing.
At the external clock output side:
through the motherboard, SCI board receives the
2.048 Mbit/s and
2.048 MHz clock signals processed by SC board, and
then sends
the clock signals to external equipment.
75 SCI board
No. Interface ID Definition
1 INB1
The first channel of 2 Mbit/s synchronous clock
input interface
2 OUTB1
The first channel of 2 Mbit/s synchronous clock
output interface
3 INB2
The second channel of 2 Mbit/s synchronous
clock input interface
4 OUTB2
The second channel of 2 Mbit/s synchronous
clock output interface
5 INH1
The first channel of 2 MHz synchronous clock
input interface
6 OUTH1
The first channel of 2 MHz synchronous clock
output interface
7 INH2
The second channel of 2 MHz synchronous
clock input interface
8 OUTH2
The second channel of 2 MHz synchronous
clock output interface
SCI board front panel
120 SCI board
NE Control Processor Subsystem
NCP unit is the network element control and processing
unit. It comprises an NCP board and an NCPI board.
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CSB
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CSB
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
NCP board functions
NCP board has NE control and Order Wire functions
NE control functions
Sends the configuration commands to other boards and collects their
performance data and alarms.
Exchanges EMS information between NEs through ECC channel.
Through the Qx interface, NCP board reports to the SMCC the alarms and
performance messages of this NE and of the subnet to which the NE belongs,
and receives the commands and configurations sent by the SMCC to the NE
and to the subnet to which the NE belongs.
Detects the fan running status, and reports alarm once the fan stops running.
Provides a four-digit DIP switch to set the software state.
NCP software state may be "Download" or "Running".
The Download state: Set the DIP switch to all ON. It is used to download applications and NCP
parameter configuration.
The Running state: Set the DIP switch to not all ON and not all OFF. It is used to start the NCP
board application and makes the NCP board to enter the normal running state.
NCP board functions
NCP board has NE control and Order Wire functions
NE control functions
Implements orderwire interworking between NEs via the E1 and E2 bytes.
Provides two voice channels that are independent with each other. The
system can support up to 16 orderwire directions.
Achieves calls based on point-to-point, point-to-multipoint, point-to-group.
Sets orderwire numbers via the EMS.
Prevents the orderwire from being looped through orderwire control point set
by EMS.
The orderwire software can be downloaded online by the EMS.
Calling mode
1.Point-to-point S1S2S3
2.Point-to-multipoint #888S1S2S3
3.Point-to-group #999S1S2S3
NCP board functional block
Control unit
Real-time clock
Qx interface
ECC interface
Board-in-position
detection
Board reset
control
NE alarm output
External alarm
input
Fan and subrack
power monitoring
Connection Between NCP and Other Boards
NCP
board
NCPI
board
External alarm
input/output
SC
board
Service
board
Reference clock input
NCP Unit



NCP
MCU

MCU

...

MCU



Subnetwork 2
LCT

f interface

NCP
NCP NCP
NCP NCP NCP

Qx interface

SDH Network Management System
Subnetwork 1
ECC interface
S interface
SMCC
NCP board front panel
1 Indicators (RUN, OW, and ALM)
2 f Interface
3Qx interface
There are three indicators on the front panel, which
are in turn the RUN (green) indicator, the M/S (green)
indicator, and the ALM (red) indicator from top to
bottom.
There are three interfaces on the front panel, which
are in turn the f interface, Qx interface, OW interface
from top to bottom
There are two buttons on the front panel, which are in
turn the Bell-Off, RESET from top to bottom.
4 Orderwire interface (OW)
5 Ring trip button (BELL-OFF)
6 Reset button (RESET)
NCPI board
1User loop trunk interface (TRK)
2Alarm output interface to head cabinet with DB9 socket
3 F1 interface/External alarm input interface
The NCPI board provides the user loop trunk
interface, alarm output interface of column head
cabinet, and F1 interface/external alarm input
interface.
There are three interfaces on NCPI board
User loop trunk interface (TRK): Connects orderwire calls
between two subnets. Uses the RJ11 socket;
Alarm output interface to head cabinet with DB9 socket;
F1 interface/External alarm input interface: Inputs
external alarms and connects the 64 K codirectional
interface equipment. It use DB15 socket(female).


CS subsystem
CSA
The higher-order cross-connection capacity is 104104 VC-4include lower-
order cross-connect capacity
The lower-order cross-connect capacity is 10081008 VC-12
CSB
The higher-order cross-connection capacity is 128128 VC-4 include lower-
order cross-connect capacity
The lower-order cross-connect capacity is 20162016 VC-12
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CSB
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CSB
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
CS board functions
CSB board cross-connects the traffic of ZXMP S330.
Implements the service interworking among multiple directions and
provides external traffic access.
Completes multiplex section APS protection switching.
Monitors the alarm information of AUs in all directions and
implements path protection switching.
Monitors the state of all service boards and implements the 1:N
(N5) board protection.
Can insert the AU-AIS signal or unequipped VC-4 data to the un-
configured service.
Can overlap 2 M traffic, namely, combine the traffic of multiple 2 M
electrical service boards into a group of AU-4 signals.
Supports 1+1 backup.
CS board functional blocks
Multiplexing/De
multiplexing
unit
2.5 G optical
transmit interface
Monitoring
unit
NCP
board
CS, SC
boards
Traffic
processing
unit
Control
unit
Optical
module
2.5 G optical
receive interface
CS board capacity
CS board capacity
CSA
The higher-order cross-connection capacity is 104104AU4
The lower-order cross-connection capacity is 1616 AU4
CSB
The higher-order cross-connection capacity is 128128AU4
The lower-order cross-connection capacity is 3232 AU4
The service access capacity assigned by CS board in each slot.
1
6
2 2 4 4
1
6
1
6
S
C
2 2 4 4
1
6
S
C
C
S
C
S
N
C
P
Note: The numbers represent service access capacity, the unit is AU-4
indicator
CS board front panel
There are three indicators on the front
panel, which are in turn the RUN (green)
indicator, the M/S (green) indicator, and
the ALM (red) indicator from top to
bottom.
The M/S indicator is the master/standby
indicator. If this indicator is constantly ON,
it indicates that the current board is in the
active state; If this indicator is constantly
OFF, it indicates that the current board is
in the standby state.

Optical Line Processor
High speed OLP board: the interface
and service processing are together in
the same board.
Low speed OLP boards: the interface
and service processing are separated
in different boards.

Optical Line board OL16x1
OL16x1 board has one STM-16 optical interface with LC/PC connector;
OL16x1 board can be installed in the slot 5,6,11,12.
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
OL16x1 board funtions
Terminates and regenerates the STM-16 regenerator section over
head and multiplex section overhead;
Interprets the AU-4 pointer and obtains the VC payload.
Forwards EMS information from optical line board to NCP board;
Outputs the received reference clock to SC board;
Supports query of parameters of four optical modules: optical
received power module, optical launched power module,
temperature module, and laser working current module;
Supports color optical interface.
Supports online query of optical module type.
Supports HP-TCM( Higher-order Path Tandem Connection
Monitoring) function. On the border of different carriers networks, it
can detect the number of B3 block errors received by this network,
as well as the number of B3 block errors sent from this network to
next network.
OL16x1 board functional blocks
Multiplexing/De
multiplexing
unit
2.5 G optical
transmit interface
Monitoring
unit
NCP
board
CS, SC
boards
Traffic
processing
unit
Control
unit
Optical
module
2.5 G optical
receive interface
OL16x1 board front panel
1Running status indicator RUN
2Work indicator M/S
3Alarm indicator ALM
4Optical transmit interface and receive interface RX/TX
5Laser warning sign
6Laser level sign
Optical line board OL1/4x4
OL1/4x4 board can process four channels of STM-1 or STM-4 optical signals.
User can set the number of optical interfaces to be 1, 2, 3, or 4 as per the
actual requirements. OL1/4x4 board supports the following three work modes:
OL1 mode: rates of all the optical interfaces are STM-1.
OL4 mode: rates of all the optical interfaces are STM-4.
OL1/4 mode: rates of some optical interfaces are STM-1, and rates of others are STM-4.
Position of OL1/4x4 Board in Subrack :
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Optical line board OL1/4x4
Descriptions of OL1/4x4 Board Positions in ZXMP S330 Subrack
Slot No. Descriptions
Lower-layer service board slots
1, 2, 15, 16
OL1/4x4 board inserted in these slots can only work in
OL1 mode. And the 3rd and 4th optical interface pairs
can only work for regenerator, not for adding/dropping
traffic.
Lower-layer service board slots
3, 4, 13, 14
OL1/4x4 board inserted in these slots can work in either
OL1 mode or OL4 mode.
When working in OL4 mode, the 2nd, 3rd and 4th optical
interface pairs can only work for regenerator, not for
adding/dropping traffic.
Lower layer service board slots
5, 6, 11, 12
OL1/4x4 board inserted in these slots can work in OL1
mode, OL4 mode, or OL1/OL4 mode.
Note: If all the optical interfaces of OL1/4x4 board work for regenerator, this OL1/4x4 board
can be inserted in any lower-layer service board slot.
OL1/4x4 board functions
OL1/4x4 board processes STM-1/4 optical signals. Its interface types
are LC/PC. It supports bidirectional fiber.
Implements conversion between optical and electrical signals.
Forwards EMS information from optical line board to NCP board.
Outputs the received reference clock to SC board.
Supports query of parameters of four optical modules: optical
received power module, optical launched power module,
temperature module, and laser working current module.
Supports online query of optical module type.
Supports HP-TCM (Higher-order Path Tandem Connection
Monitoring) function. On the border of different carriers networks, it
can detect the number of B3 block errors received by this network,
as well as the number of B3 block errors sent from this network to
next network.
OL1/4x4 board functional blocks
Multiplexing/De
multiplexing
unit
622 M/155 M optical
transmit interface
Monitoring
unit
NCP
board
CS, SC
boards
Traffic
processing
unit
Control
unit
Optical
module
622 M/155 M optical
receive interface
OL1/4x4 board front panel
1. Running status indicator (RUN)
2. Work indicator (M/S)
3. Alarm indicator (ALM)
4. Optical transmit interfaces and receive interfaces (TX, RX)
5. Laser warning sign
6. Laser level sign
OL1/4 Subsystem
Processes STM-1 or STM-4 optical traffic, and STM-1 electrical
traffic.Provides 1:N (N5) protection for the boards that process
STM-1 electrical traffic.
different board combinations implement different functions.
Function Boards Involved
Process STM-1 optical traffic LP1x1 (or LP1x2), OIS1x1 (or OIS1x2)
Process STM-1 electrical
traffic
LP1x1 (or LP1x2), ESS1x2
Provide 1:N (N5) protection
for the board processing
STM-1 electrical traffic
LP1x1 (or LP1x2), ESS1x2, BIS1
Process STM-4 optical traffic LP4x1 (or LP4x2), OIS4x1 (or OIS4x2)
Note: ZXMP S330 can support at most two groups of 1:N (N5) protection for
the boards that process STM-1 electrical traffic.
Connection relations in OL1/4 subsystem
The interface board and the service board are connected via STM-1/4 electrical signals.
The service board is connected to the CS board via a bus. The service board converts the
STM-1/4 data got from the interface board into a bus and then sends the data to the CS
board. And the service board also obtains the bus data sent by the CS board, processes
the data, and then sends the data to the interface board.
The service board exchanges the DCC information on the line with the NCP board, and
provides overhead bytes for the orderwire part of the NCP.
The SC board provides the service board with the system clock and the system frame
head. The service board divides the frequency of the received clock, and then sends it to
the SC board as one of the reference clocks.
Service board CS board
SC board
NCP board
R
e
c
e
i
v
e
d

c
l
o
c
k

r
e
f
e
r
e
n
c
e

S
y
s
t
e
m

c
l
o
c
k

a
n
d

f
r
a
m
e

h
e
a
d

Interface board
Switching board
Positions of boards in OL1/4 subsystem
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Available Slots of Boards in OL1/4 Subsystem
Board ID Available Slots Remarks
LP1x1
LP1x2
Lower-layer service board slots 1
to 6 and slots 11 to 16
The protection board can only be inserted in
slot 1 and slot 16.
LP4x1
LP4x2
Lower-layer service board slots 3
to 6 and slots 11 to 14
When LP4x2 board is inserted in slot 3, 4, 13,
or 14, its 2nd optical interface pair can only
work for regenerator, not for adding/dropping
traffic.
BIS1
Upper-layer service interface board
slot 1 and slot 16.
It is used when the 1:N (N5) protection is
required for the boards that process STM-1
electrical traffic.
OIS1x1
OIS1x2
Upper-layer service interface board
slots 1 to 6 and slots 11 to 16
-
ESS1x2
Upper-layer service interface board
slots 1 to 6 and slots 11 to 16
-
OIS4x1
OIS4x2
Upper-layer service interface board
slots 3 to 6 and slots 11 to 14
OIS4x1 board works with LP4x1 board.
OIS4x2 board works with LP4x2 board.
OL1/4 Subsystem functional blocks
Multiplexing/De
multiplexing
unit
622 M/155 M optical
transmit interface
Monitoring
unit
NCP
board
CS, SC
boards
Traffic
processing
unit
Control
unit
Optical
module
622 M/155 M optical
receive interface
LP1x1/LP1x2 boards
LP1x1 board processes one channel of STM-1 traffic.
LP1x2 board processes two channels of STM-1 traffic.
Forwards EMS information from optical line board to NCP board, and
outputs the received reference clock to the SC board.
Works with ESS1x2 board to process STM-1 electrical traffic.
Works with ESS1x2 board and BIS1 board to implement 1:N (N5)
protection for the boards that process STM-1 electrical traffic.
Works with OIS1x1 or OIS1x2 board to process STM-1 optical traffic.
indicator

LP1 board front panel
There are three indicators on the
front panel, which are in turn the
RUN (green) indicator, the M/S
(green) indicator, and the ALM
(red) indicator from top to bottom.
M/S indicator is ON if the board is
in active status. It is OFF if the
board is in standby status.

LP4x1/LP4x2 board
LP4x1 board processes one channel of STM-4 traffic.
LP4x2 board processes two channels of STM-4 traffic.
Forwards EMS information from optical line board to NCP board, and
outputs the received reference clock to the SC board.
Works with OIS4x1 or OIS4x2 board to process STM-4 optical traffic.

ESS1x2 board
ESS1x2 board is the interface switching board. It has the following functions:
Provides LP1x1/LP1x2 board with two STM-1 electrical receive interfaces
and two STM-1 electrical transmit interfaces.
When 1:N (N5) protection for LP1x1/LP1x2 board is not required, the
ESS1x2 board only performs STM-1 electrical interface function.
When 1:N (N5) protection for LP1x1/LP1x2 board is required, ESS1x2
board works with BIS1 board to implement 1:N (N5) protection for
LP1x1/LP1x2 board.
At the receive side, ESS1x2 board receives the 155 Mbit/s electrical
signal from the outside. Then it processes the electrical signal and sends
it to LP1x1/LP1x2 board via the motherboard for further processing.
At the transmit side, ESS1x2 board receives the 155 Mbit/s electrical
signal sent by LP1x1/LP1x2 board via the motherboard. It processes the
electrical signal, and then sends the signal to the outside.
In the case of 1:N (N5) protection for LP1x1/LP1x2 board, ESS1x2
board decides whether to send the electrical signal to the working
LP1x1/LP1x2 board or to the protection LP1x1/LP1x2 board according to
the control signal from the CS board.
1. Electrical receive interface
2. Electrical transmit interface
3. Electrical receive interface
4. Electrical transmit interface
OIS1x1/OIS1x2/OIS4x1/OIS4x2 board
OIS1x1 board provides LP1x1 board with one STM-1 optical
receive/transmit interface.
OIS1x2 board provides LP1x2 board with two STM-1 optical
receive/transmit interfaces.
OIS4x1 board provides LP4x1 board with one STM-4 optical
receive/transmit interface.
OIS4x2 board provides LP4x2 board with two STM-4 optical
receive/transmit interfaces.
The optical transmit interfaces can shut down laser.
At the receive side, the board receives 622 Mbit/s or 155
Mbit/s optical signal, it converts the optical signal into
electrical signal, and informs the service board about optical
signal loss. Finally, it sends the electrical signal to line
processor board via motherboard for further processing.
At the transmit side, the board receives electrical signal sent
by line processor board via the motherboard. Then, it
converts the electrical signal into 622 Mbit/s or 155 Mbit/s
optical signal. In addition, it controls the laser shutdown.
Finally, it transmits the optical signal to the outside.
11
21
32
42
BIS1 board
BIS1 board is a bridge interface board
Used only when the 1:N protection for LP1x1/LP1x2 board is
required, and inserted in the service interface board slot
corresponding to the protection LP1x1/LP1x2 board.
According to the protection control signal from CS board, BIS1
board functions as a bridge between the protection LP1x1/LP1x2
board and the ESS1x2 board which corresponds to the faulty
LP1x1/LP1x2 board.
When fault occurs to a working LP1x1/LP1x2 board, according to
the control signal sent by CS board, BIS1 board bridges the
signals sent/received by the ESS1x2 board which corresponds to
the faulty LP1x1/LP1x2 board to the protection LP1x1/LP1x2
board for processing.
BIS1 board has no front panel and external interface.
OL1/4 Subsystem Configuration Example
With this configuration, the subsystem can process STM-1 electrical
traffic.
It can provide one group of 1:3 protection for LP1x1 boards. The
LP1x1 board in slot 1 is the protection board; and the LP1x1 boards
in slots 2, 3, and 4 are working boards.
BIS1
1
E
S
S
1
x
2
2 3 4 5 6
SCI PWR PWR
11 12 13 14 15 16
NCPI
E
S
S
1
x
2
7 8 9 10 17
E
S
S
1
x
2
Fan plug-in box
1 2 3 4 5
SC CS CS
11 12 13 14 15 16
NCP SC
17 6 7 8 9 10
L
P
4
x
1
L
P
4
x
1
L
P
1
x
1
O
I
S
4
x
1
O
I
S
4
x
1
O
I
S
1
x
1
L
P
4
x
1
L
P
4
x
1
L
P
1
x
1
L
P
1
x
1
L
P
1
x
1
L
P
1
x
1
O
I
S
4
x
1
O
I
S
4
x
1
OA board
OA board amplifies one channel of optical signal.
Its amplification function is independent of optical signal rate.
By amplifying the optical power of light with 1550 nm wavelength,
OA board can improve the non-regenerator transmission distance
and provide transparent transmission channel for optical signals.
The data rate can be 2.5 Gbit/s, 622 Mbit/s, or 155 Mbit/s.
OA board supports query of four kinds of parameters: optical
launched power, optical received power, module temperature, and
laser working current.
E
a
s
t

o
p
t
i
c
a
l

l
i
n
e

b
o
a
r
d
OA
board
W
e
s
t

o
p
t
i
c
a
l

l
i
n
e

b
o
a
r
d

OA board
In practice, EDFA is classified into Optical Booster Amplifier (OBA),
Optical Pre-Amplifier (OPA), or Optical Line Amplifier (OLA)
according to the position and effect of EDFA.
OBA locates at the transmitting end of the system. It boosts the optical launched
power of the system, and extends the distance of the regenerator.
OPA locates at the receiving end of the system. It amplifies the weak transmitted
signals, and boosts the input power of the system receiver.
OLA locates in the middle of the optical fiber line of the system. It replaces the
optical regenerator.

OA board can be inserted in any service board slot in ZXMP
S330 subrack
OA board front panel
1. Running status indicator (RUN)
2. Work indicator (M/S)
3. Alarm indicator (ALM)
4. Optical transmit interface and receive interface (TX, RX)
5. Laser warning sign
6. Laser level sign
EP1 Subsystem
Maps/demaps PDH E1/T1 electrical signals.
Provides 1:N (N5) protection for E1/T1 tributary boards.
The EP1 subsystem comprises EPE1x21, EPT1x21, EPE1B,
BIE1x21, and ESE1x21 boards.
Different board combinations can implement different functions
Function Boards Involved
Process E1 electrical signal EPE1x21 (or EPE1B) and ESE1x21
Provide 1:N (N5) protection for E1
tributary board
EPE1x21 (or EPE1B), BIE1x21, and
ESE1x21
Process T1 electrical signal EPT1x21 (or EPE1B) and ESE1x21
Provide 1:N (N5) protection for T1
tributary board
EPT1x21 (or EPE1B), BIE1x21, and
ESE1x21
Positions of EP1 Subsystem Boards
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Available Slots of Boards in EP1 Subsystem
Board ID Available Slots Remarks
EPE1x21,
EPT1x21,
EPE1B
Lower-layer service board slots 1
to 6 and slots 11 to 16
The protection board can be
inserted in any slot of lower-
layer service board slots 1 to 6
and slots 11 to 16.
ESE1x21
Upper-layer service interface board
slots 1 to 6 and slots 11 to 16.
-
BIS1
Upper-layer service interface board
slots 1 to 6 and slots 11 to 16.
It is used when the 1:N (N5)
protection is required for E1/T1
tributary board. It is inserted in
the service interface board slot
corresponding to the protection
tributary board.
EPE1x21/EPT1x21/EPE1B board
These boards are E1/T1 (electrical) tributary boards.
EPE1x21 can process up to 21 channels of E1 traffic.
EPT1x21 can process up to 21 channels of T1 traffic.
EPE1B can process up to 21 channels of E1 or T1 traffic.
The timeslots used to add traffic and the timeslots used to drop traffic can be different.
Supports concurrent transmitting and preferred receiving. "Preferred receiving" is implemented by
detecting alarm and performance data in different timeslots, and then selecting the relatively normal
timeslots for demapping. "Concurrent transmitting" is implemented by sending data to different AU
bus timeslots concurrently.
Extracts and inserts path overheads.
For each board, four tributaries support tributary retiming, and four tributaries support clock
extraction from tributary.
Works with BIE1x21 and ESE1x21 boards to implement the 1:N (N5) protection for tributary board.
ZXMP S330 supports at most two groups of 1:5 protection for EPE1x21/EPT1x21/EPE1B boards.
Besides the above functions, EPE1B board supports the unframing and framing methods:
Unframing method: The board only detects LOS alarm, AIS alarm, and CV performance count at
E1/T1 interface.
Framing method: Besides all the information detected in the unframing method, the board also
detects the LOF/RAI framing alarm of received E1/T1 signal, and displays them on the EMS. User
can judge whether fault is caused by transmission equipment or by terminal equipment according to
the EMS framing alarm information.

EPE1x21/EPT1x21/EPE1B board functional
blocks
Traffic
processing
unit
Clock unit
E1/T1 tributary traffic
System clock,
frame head
Tributary clock
Control unit
Power
supply unit
NCP
board
CS
board
ESE1x21 board
ESE1x21 board is the interface switching board.
Provides twenty-one E1/T1 electrical interface pairs.
When 1:N (N5) protection for tributary board is needed, ESE1x21 board
works with BIE1x21 board to implement the protection.
When 1:N (N5) protection for tributary board is not needed, ESE1x21
board only provides E1/T1 electrical interfaces.
At the receive side, ESE1x21 board receives the E1/T1 electrical signal
from the outside, extracts the electrical signal, and then sends it to the
electrical tributary board via the motherboard for processing.
At the transmit side, ESE1x21 board receives the signal sent by the
electrical tributary board via the motherboard, and then sends the signal to
the outside.
In the case of 1:N (N5) protection for tributary board, ESE1x21 board
determines whether to send the electrical signal to the working tributary
board or to the protection tributary board according to the control signal
from CS board.
1. Electrical interface
BIE1x21 board
Functions as a bridge between the protection tributary board and the
interface switching board corresponding to the faulty tributary board.
Used only when 1:N (N5) protection for E1/T1 tributary board is
required.
Is inserted in the service interface board slot corresponding to the
protection tributary board.
When fault occurs to a working EPE1x21/EPT1x21/EPE1B board,
according to the control signal sent by CS board, BIE1x21 board
bridges the signals sent/received by the ESE1x21 board which
corresponds to the faulty tributary board to the protection tributary
board for processing.
BIE1x21 board has no front panel and external interface.
EP1 Subsystem Configuration Example
With this configuration, the system can process E1 electrical traffic.
It can provide one group of 1:3 protection for EPE1x21 boards. The
EPE1x21 board in slot 1 is the protection board; and the EPE1x21
boards in slots 2, 3, 4 are working boards.
B
I
E
1
x
21
1
E
S
E
1
x
2
2 3 4 5 6
SCI PWR PWR
11 12 13 14 15 16
NCPI
E
S
E
1
x
2
7 8 9 10 17
E
S
E
1
x
2
Fan plug-in box
1 2 3 4 5
SC CS CS
11 12 13 14 15 16
NCP SC
17 6 7 8 9 10
O
L
16
x
1
E
P
E
1
x
21
E
P
E
1
x
21
E
S
E
1
x
21
E
S
E
1
x
21
O
L
16
x
1
O
L
16
x
1
E
P
E
1
x
21
E
P
E
1
x
21
E
P
E
1
x
21
E
P
E
1
x
21
EP3 Subsystem
Maps/demaps PDH E3/T3 electrical signals.
Provides 1:N (N5) protection for E3/T3 tributary boards.
Comprises EPE3x3, EPT3x3, EP3x3, ESE3x3, and BIE3x3 boards.
Different board combinations can implement different functions
Function Boards Involved
Process E3 electrical signal EPE3x3 (or EP3x3), ESE3x3
Provide 1:N (N5) protection for E3
tributary board
EPE3x3 (or EP3x3), BIE3x3,
ESE3x3
Process T3 electrical signal EPT3x3 (or EP3x3), ESE3x3
Provide 1:N (N5) protection for T3
tributary board
EPT3x3 (or EP3x3), BIE3x3,
ESE3x3
Positions of EP3 Subsystem Boards









S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Available Slots of Boards in EP3 Subsystem
Board ID Available Slots Remarks
EPE3x3,
EPT3x3,
EP3x3
Lower-layer service board slots 1
to 6 and slots 11 to 16
The protection board can only be
inserted in slot 1 and slot 16.
ESE3x3
Upper-layer service interface
board slots 1 to 6 and slots 11 to
16.
-
BIS1
Upper-layer service interface
board slot 1 and slot 16.
It is used when the 1:N (N5)
protection is required for E3/T3
tributary board. It is inserted in
the service interface board slot
corresponding to the protection
tributary board.
EPE3x3/EPT3x3/EP3x3 board functions
These three boards are (electrical) tributary boards.
EPE3x3 can process three channels of E3 traffic.
EPT3x3 can process three channels of T3 traffic.
EP3x3 can process three channels of E3 or T3 traffic. Its port rate can be configured as E3 or
T3 via the EMS. It supports mapping/demapping and multiplexing/demultiplexing of three
channels of E3/T3 signals into/from any timeslot of an AU-4.
EP3x3 supports the unframing and framing methods:
Unframing method: For E3 interface, EP3x3 board detects LOS/AIS alarm and CV
performance count. For T3 interface, EP3x3 board only detects LOS alarm and CV
performance count.
Framing method: Besides all the information detected in the unframing method, EP3x3 board
also detects the LOF/RAI framing alarm of received E3/T3 signal, and AIS alarm of received
T3 signal; and displays them on the EMS. User can judge whether fault is caused by
transmission equipment or by terminal equipment according to the EMS framing alarm
information.
The timeslots used to add traffic and the timeslots used to drop traffic can be different.
Reads the alarm and performance information of E3/T3 interface and VC-3 path; and reports
them to the EMS.
Works with BIE3x3 and ESE3x3 boards to implement the 1:N (N5) protection for tributary
board.
ZXMP S330 supports at most two groups of 1:5 protection for EPE3x3/EPT3x3/EP3x3
boards.
EPE3x3/EPT3x3/EP3x3 board functional
blocks
Traffic
processing unit
Control unit
Clock unit
Line interface
unit
E3/T3 tributary
traffic
System clock
Reference clock
NCP
board
CS
board
Power
supply unit
ESE3x3 board
ESE3x3 board is the interface switching board.
Provides three E3/T3 electrical interface pairs.
When 1:N (N5) protection for tributary board is needed, ESE3x3 board
works with BIE3x3 board to implement the protection.
When 1:N (N5) protection for tributary board is not needed, ESE3x3
board only provides E3/T3 electrical interfaces.
At the receive side, ESE3x3 board receives E3/T3 electrical signal from
the outside, extracts the electrical signal, and then sends the signal to
the electrical tributary board via the motherboard for processing.
At the transmit side, ESE3x3 board receives the signal sent by the
electrical tributary board via the motherboard, and then sends the
signal to the outside.
In the case of 1:N (N5) protection for tributary board, the ESE3x3
board determines whether to send electrical signal to the working
tributary board or to the protection tributary board according to the
control signal from CS board.

1. Electrical receive interface 1 2. Electrical transmit interface 1
3. Electrical receive interface 2 4. Electrical transmit interface 2
5. Electrical receive interface 3 6. Electrical transmit interface 3
BIE3x3 board
Functions as a bridge between the protection tributary board and the
ESE3x3 board corresponding to the faulty tributary board.
Used only when 1:N (N5) protection for E3/T3 tributary board is
required.
Inserted in the service interface board slot corresponding to the
protection tributary board.
When fault occurs to a working EPE3x3/EPT3x3/EP3x3 board,
according to the control signal sent by CS board, BIE3x3 board
bridges the signals sent/received by the ESE3x3 board which
corresponds to the faulty tributary board to the protection tributary
board for processing.
BIE3x3 board has no front panel and external interface.
EP3 Subsystem Configuration Example
With this configuration, the system can process E3 and T3 electrical
traffic.
It can provide one group of 1:3 protection for EPE3x3 boards. The
EPE3x3 board in slot 1 is the protection board; and the EPE3x3
boards in slots 2, 3, 4 are working boards.
B
I
E
3
x
3
1
E
S
E
3
x
3
2 3 4 5 6
SCI PWR PWR
11 12 13 14 15 16
NCPI
7 8 9 10 17
Fan plug-in box
1 2 3 4 5
SC CS CS
11 12 13 14 15 16
NCP SC
17 6 7 8 9 10
O
L
16
x
1
O
L
16
x
1
O
L
16
x
1
E
P
E
3
x
3
E
P
E
3
x
3
E
P
E
3
x
3
E
P
E
3
x
3
O
L
16
x
1
E
S
E
3
x
3
E
S
E
3
x
3
E
S
E
3
x
3
E
S
E
3
x
3
E
P
E
3
x
3
E
P
T
3
x
3
EOS Subsystem
Provides Ethernet electrical interfaces or Ethernet optical
interfaces.
Provides 1:N (N5) protection for Ethernet processor board that
processes Ethernet electrical traffic.
Connects the traffic between LANs, and the traffic between LAN
and WAN, through the SDH system.
The EOS subsystem comprises SFEx6, EIFEx4, EIFEx6, OIS1x4,
OIS1x6 and BIFE boards.
Different board combinations can implement different functions.
Function Boards Involved Remarks
Process Ethernet electrical traffic
SFEx6, EIFEx4, SED
and EIFEx6
-
Provide 1:N (N5) protection for
SFEx6 board that processes Ethernet
electrical traffic
SFEx6, EIFEx4, and
BIFE
-
Process Ethernet optical traffic
SFEx6, OIS1x4, SED
and OIS1x6
Provides no protection
for the interface.
EOS Subsystem Board Positions
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Available Slots of Boards in EOS Subsystem
Board ID Available Slots Remarks
SFEx6,
SED
Lower-layer service
board slots 1 to 6 and
slots 11 to 16
When 1: N (N5) Ethernet electrical service
protection is needed, the protection board
SFEx6 can be inserted in any slot of lower-layer
service board slots 1 to 6 and slots 11 to 16.
EIFEx4 and
EIFEx6,
OIS1x4 and
OIS1x6
Upper-layer service
interface board slots 1 to
6 and slots 11 to 16.
-
BIFE
Upper-layer service
interface board slots 3 to
6 and slots 11 to 14.
It is used when the 1:N (N5) protection is
required for SFEx6 boards that process Ethernet
electrical traffic. It is inserted in the service
interface board slot corresponding to the
protection SFEx6 board.
SFEx6 board
SFEx6 board is the smart fast Ethernet board. It implements switching, mapping, and
demapping of traffic between Ethernet interfaces.
Supports four user ports (LAN interfaces) at the user side. Processes four channels of
optical or electrical Ethernet traffic. Optical interfaces are provided by the OIS1x4
board, and electrical interfaces are provided by EIFEx4 board.
Provides six system ports (WAN interfaces), and each with bandwidth of N2.176 M.
Each WAN interface can be allocated with one to forty-six VC-12s, i.e., 2 M to 100 M,
using virtual concatenation method as per the requirement.
Up to 252 VC-12s can be allocated to all the WAN interfaces at the system side.
Traffic of any WAN interface at the system side is carried by N (N= 1 to 46) bound
VC-12s.
The bindings are configured in the EMS. Multiple bound VC-12s are mapped into VC-
4 using the virtual concatenation method.
Four LAN interfaces (user ports) can switch between each other at the L2 (the second
layer of OSI model) line rate. In the transparent transmission mode, the four LAN
interfaces and the first to fourth WAN interfaces can implement pure transparent
transmission of fixed connections.
Supports two VLAN modes: port-based VLAN and TAG-based VLAN.
All the ports together support 4094 VLAN IDs.
In the EMS, user can configure VLAN, flow control, address learning, spanning tree,
QoS, and Trunk.
Drops timeslots from AU bus, and maps traffic into the corresponding AU timeslots.
Provides path protection for traffic.
Extracts/inserts path overheads.
SFEx6 board functional blocks
Mapping/
demapping
unit
Control
unit
Clock
allocation unit
Power
supply unit
System clock,
frame head
L2
switching
unit
Ethernet
interface
unit
Optical/electrical
interface board
CSB
board
SED
Supports 8 FE and 2 GE Ethernet interfaces at the user side, thus accesses 10 channels of Ethernet
signal (LAN signal).
There are 2 GE interfaces and 2 FE optical interfaces on the panel of the SED board. Among them, the
GE interfaces support SFP optical or electrical interface module. As for the other 6 FE Ethernet
interfaces, the physical electrical interfaces are provided by the EIFEx6 interface board and the
physical optical interfaces are provided by the OIS1x6 interface board.
Supports 16 VCG (EOS) ports at the system side, each port has the system bandwidth up to 8 AUGs.
These VCG ports support 16:1 convergence ratio and bidirectional throughput capacity is up to 1Gbit/s.
Supports three kinds of virtual concatenation: VC-12-Xv, VC-3-Xv and VC-4-Xv. Among which, VC-12-
Xv and VC-3-Xv can be mapped into a same VC-4 virtual container.
A virtual concatenation supported by the SED board can contain 504 VC-12s, 24 VC-3s or 8 VC-4s at
most. Each virtual concatenation group can bind 1-63 VC-12s, 1-24 VC-3s or 1-8 VC-4s.
Uses a flexible VLAN processing mode, to configure the VLAN as per the service requirements, as well
as to add, strip or modify the VLAN.
Supports identifying QinQ and uses the outmost label 802.1Q as VLAN label to perform the research
and learning, as well as isolate the service in the ring network.
Supports the speed limitation based on port, VLAN ID or priority.
Supports Jumbo frame of 1600 bytes.
Supports LCAS and Spanning Tree Protocol (STP).
Supports Trunk function at the port.
Supports GFP encapsulation structure.
Implements extracting/inserting path overhead.
SED board functional blocks
Mapping/
demapping
unit
Control
unit
Clock
allocation unit
Power
supply unit
System clock,
frame head
Ethernet
switching
unit
Ethernet
processing
unit
10 M/100 M
Ethernet
interface
CSB
board
1000 M
Ethernet
interface
OIS1x4/OIS1x6 board
OIS1x4 and OIS1x6 boards are the optical interface boards.
Provide the service processing board with 4 or 6 STM-1 optical
interfaces separately.
Support the function of shutting down the laser.
At the receive side, the board receives optical signal from the outside.
Then it converts the optical signal into electrical signal and extracts the
line signal. Finally, it sends the processed electrical signal to the service
processing board via the motherboard for processing.
At the transmit side, the board receives electrical signal sent by the
service processing board via the motherboard. Then, it converts the
electrical signal into optical signal. Finally, it transmits the optical signal
to the outside.
The board structures of OIS1x4 and OIS1x6 are similar with each other
except for the interface number on the front of the boards.
Take an OIS1x4 board as an example. The interfaces on the OIS1x4 board are Ethernet
optical interfaces with LC/PC connectors, with the ascending numberings from top to
bottom.
The optical interfaces employ the SFP optical module. When working as Ethernet optical
interfaces, they support the 100 M duplex work mode.
SED board front panel
1. Running status indicator (RUN)
2. Master/slave indicator (M/S)
3. Alarm indicator (ALM)
4. FE optical interface
5. GE optical interface
EIFEx4/ EIFEx6 board
Provide 4/6 pairs of the Ethernet electrical interface.
When 1:N (N5) protection is needed, EIFEx4 board works
with BIFE board to implement the protection.
When 1:N (N5) protection is not needed, EIFEx4 board only
provides Ethernet electrical interfaces.
EIFEx4 and EIFEx6 have the same working principle.
At the receive side, the board receives Ethernet electrical signal from the
outside, extracts the electrical signal, and then sends the signal to the
Ethernet board via the motherboard for processing.
At the transmit side, the board receives the signal sent by the Ethernet
board via the motherboard, and then sends the signal to the outside.
In the case of 1:N (N5) protection, EIFEx4 board determines
whether to send the signal to the working board or to the
protection board according to the control signal from the CSB
board.
BIFE board
BIFE board is the bridge interface board.
Functions as a bridge between the protection SFEx6 board and the interface
switching board (EIFEx4) corresponding to the faulty SFEx6 board.
Used only when 1:N (N5) protection for FE electrical traffic is required.
Inserted in the service interface board slot corresponding to the protection
board.
When fault occurs to a working SFEx6 board, according to the control signal
sent by CS board, BIFE board bridges the signals sent/received by the
EIFEx4 board which corresponds to the faulty SFEx6 board to the protection
SFEx6 board for processing.
BIFE board has no front panel and external interface.
EOS Subsystem Configuration Example
With this configuration, the system can process Ethernet electrical
traffic by the SFEx6 board and Ethernet optical traffic by the SED
board.
It can provide one group of 1:3 protection for Ethernet electrical
traffic. The SFEx6 board in slot 3 is the protection board; and the
SFEx6 boards in slots 1, 2, 4 are working boards.
B
I
F
E
1
E
I
F
E
x
4
2 3 4 5 6
S
C
I
11 12 13 14 15 16
N
C
P
I
P
W
R
P
W
R
7 8 9 10 17
Fan plug-in box
1 2 3 4 5
S
C
C
S
B
11 12 13 14 15 16
N
C
P
S
C
17 6 7 8 9 10
O
L
16
x
1
O
L
16
x
1
S
F
E
x
6
S
E
D
S
F
E
x
6
S
F
E
x
6
S
F
E
x
6
E
I
F
E
x
4
E
I
F
E
x
4
C
S
B
O
I
S
1
x
6
ATM Subsystem
ATM subsystem converges or aggregates ATM traffic to SDH
transmission network.
It comprises AP1x4 board and OIS1x4 board.
AP1x4 board is the ATM processor board, OIS1x4 board is the
service interface board.
Slots for AP1x4 board: slots 1 to 6 and slots 11 to 16 at subrack lower layer.
Slot for OIS1x4 board: upper-layer service interface board slot corresponding to
AP1x4 board.
ATM Subsystem board positions









S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CSB
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CSB
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
AP1x4 board
AP1x4 board is the ATM processor board.
Provides four 155 Mbit/s optical interfaces at the ATM side, and four
155 Mbit/s non-concatenated data flows at the system side.
User can select one to four VC-4 channels to transmit ATM traffic.
It can extract the line clock which can serve as the clock source for
equipment.
Supports four ATM traffic types: Constant Bit Rate (CBR) traffic, real-
time Variable Bit Rate (rt-VBR) traffic, non real-time Variable Bit Rate
(nrt-VBR) traffic, and Unspecified Bit Rate (UBR) traffic.
Supports VP/VC local exchange.
Supports VP protection switching upon alarms such as VP-AIS,
LOS, LOF, OOF, LAIS, and LCD.
AP1x4 board functional blocks
CS
board
Clock
processing
unit
ATM traffic
processing unit
Control unit
SC
board
ATM traffic
Ethernet interface
(for debugging, or
communication with
maintenance console)
OIS1x4
board
ATM Subsystem Configuration Example
With this configuration, the system can process ATM traffic.
1 2 3 4 5 6
SCI PWR PER
11 12 13 14 15 16
NCPI
7 8 9 10 17
Fan plug-in box
1 2 3 4 5
SC CS CS
11 12 13 14 15 16
NCP SC
17 6 7 8 9 10
O
L
16
x
1
O
L
16
x
1
O
L
16
x
1
O
L
16
x
1
A
P
1
x
4
O
I
S
1
x
4
RPR Subsystem
Maps Ethernet traffic to RPR.
Implements the unique functions of RPR.
Uses the channel bandwidth resource of SDH/MSTP ring network to
provide the dual-ring topology required by RPR, and to interconnect
the rings.
RPR subsystem comprises RSEB, EIFEx4, and OIS1x4 boards.
Different board combinations can implement different functions.
Function Boards Involved
Process RPR service (GE optical interface, FE electrical
interface)
RSEB and EIFEx4
Process RPR service (GE optical interface, FE optical interface) RSEB and OIS1x4
Note: EIFEx4 board provides RSEB board with electrical interfaces. OIS1x4 board provides
RSEB board with optical interfaces. Refer to the EIFEx4/EIFEx6 Board section and the
OIS1x4/OIS1x6 Board section for details about these two boards.
RPR Subsystem Board Positions
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

PWR SCI
S
e
r
v
i
c
e

i
n
t
e
r
f
a
c
e

b
o
a
r
d

NCPI
S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

CS
S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

S
e
r
v
i
c
e

b
o
a
r
d

SC SC
S
e
r
v
i
c
e

b
o
a
r
d

NCP
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
RSEB board
Supports the Q in Q identification; uses the outmost 802.1Q identifier as the VLAN identifier to
isolate users; participates in learning, searching, and isolating traffic on the ring network.
Supports different users by identifying them with VLAN ID. Every user can have multiple VLAN
IDs, so that he can be completely isolated not only at local site but also between different sites,
and thus satisfies the requirement of different user for data security.
Every user can have traffic of different priorities (including class A, B, and C). And VLAN ID varies
with the traffic class.
The bandwidth and peak-value rate of traffic with a certain priority can be configured.
Supports the fairness algorithm.
Supports the topology discovery and protection function, and passthrough mode.
Supports the configuration of EMS, query of alarm and performance, and other queries (including
port running status and RPR ring topology relation diagram).
The RPR ring bandwidth can be configure; supports VC4-xv and VC3-xv virtual concatenation;
supports the bandwidth-adjustable RPR ring with granularity of VC-4.
Supports the Bypass RPR MAC function: traffic is only switched by Ethernet and is not switched by
RPR MAC.
There are two kinds of RSEB board: RSEB-RPR and RSEB-EOS.
RSEB-RPR board is the ordinary RSEB board. It provides the RPR networking function.
RSEB-EOS board implements the pure EOS function with two GE interfaces (RPR system ports) by using Bypass RPR MAC
switching.
RSEB board functional blocks
Ethernet traffic accesses to RPR network through four FE interfaces,
two GE interfaces, or four EOS system ports.
Traffic at these interfaces/ports is aggregated to the system GE
interface (RPR system port) via the Ethernet switching unit, and then
is sent to the RPR processing unit to implement all the functions of
the RPR MAC adaptation layer.

RPR
processing
unit
RPR MAC
Span 1
Span 2
Local
traffic
GE/FE
interface
EOS
unit
POS/
EOS
EOS system
port
FE interface
RPR system
port
VCG(RPR Span)port
VCG(EOS)
Accessing side
System side
GE
interface
...
802.3
Ethernet
switching
unit
RSEB board front panel
1. Indicators
2. GE optical interface pair 1
3. GE optical interface pair 2
4. Laser warning sign
5. Laser level sign
RPR Subsystem Configuration Example
With this configuration, the RPR system can process RPR traffic.
1 2 3 4 5 6
S
C
I
11 12 13 14 15 16
N
C
P
I
P
W
R
P
W
R
7 8 9 10 17
Fan plug-in box
1 2 3 4 5
S
C
C
S
C
S
11 12 13 14 15 16
N
C
P
S
C
17 6 7 8 9 10
O
L
16
x
1
O
I
S
1
x
4
R
S
E
B
O
L
16
x
1
O
L
16
x
1

You might also like