15
10
10
10
TYPICAL CLEARANCES
100
T.O.G.
A
850
B
1700 6626
3000 1300
1750
2759
1
1000
243
1000
900
1000
1707
700
300
1250
200 100
15 00 DI
10
175
1000
63 237
147
304
304
304 146
303 147
304
1000
4626
2020
4500
1250
4626 750
1086
1000
1066
100
REMOVABLE PANEL
200
500
500
1205
10 ON SLOPING WALKWAYS WHERE CLEATS ARE REQD. ALL STANDARD PANELS SHOULD BE IDENTICAL
1250
243
63
241 63 957
356 300 300 500 300 300 7726 1000 1700 1300 1100 1122 356 922
80 TYP 63
73
243
200 800
175
1000
707
900
CLEAT DETAILS
LOAD BAR LOAD BAR
NOTES: 1. ALL GRATING TO BE WEBFORGE A325MPG. 1000 1500 2. ALL PANELS & CUT-OUTS TO BE FULLY BANDED. 3. INDICATES LOAD BAR DIRECTION. PLAN 4. INDICATES ABRASIVE NOSING. 5. INDICATES 130 x 6FL KICK PLATE. 6. GRATING TO BE SECURED BY STANDARD WEBFORGE FASTENERS. 7. SPLICE GRATING AROUND CUT-OUTS DENOTED
ON RL 27.340 T.O.S.
CROSSROD
100 MIN
GRATING SYMBOLS
3 25(325) VARIES
CROSSROD
WELD ONE SIDE OF EVERY LOAD BAR WHERE GRATING IS NOT SUPPORTED
LOAD BAR
SUPPORT LUG
25(325)
ALL BANDING BARS TO BE 5mm ALL KICK PLATE TO BE 6mm ALL PENETRATIIONS/CUT-OUTS WILL BE TAKEN TO THE NEAREST LOAD BAR IF PENETRATIONS/CUT-OUTS FALL WITHIN 40mm OF A LOAD BAR PENETRATIONS INDICATED THUS * TO BE SPLIT PENETRATIONS/CUT-OUTS LESS THAN 100 TO BE FABRICATED SQUARE
ST
INDICATES ALL PANELS FULLY BANDED INDICATES PANELS CUT TO SIZE ONLY (ie. UNBANDED) INDICATES DIRECTION OF LOAD BARS INDICATES ABRASIVE NOSING INDICATES FLOOR PLATE NOSING INDICATES PERFORATED PLATE NOSING INDICATES SIDE JOIN INDICATES 10mm SQUARE BAR CLEATS INDICATES CUTTING START INDICATES KICK PLATE
WELDS TO BE STAGGERED
GRATING PENETRATIONS/CUT-OUTS
NOSING LINE
5 40 GOING
FOR
AL R E GEN
0
REV
SE A E REL
NG SI NO 15 LIN E
TW 19/5/05
BY DATE
RISE
STRINGER
10 MIN
STRINGER
WEBFORGE (WA)
24 TENNANT STREET, WELSHPOOL WESTERN AUSTRALIA A.C.N. 009 419 756
Phone (08) 9361 8933 Fax (08) 9361 7057
50 x 50 x 5L SUPPORT
50 x 50 x 5L SUPPORT
JOB: DETAIL:
WEBFORGE GRID TYPE DRAWN
STD - 003/0
REV.
TAW
DATE
30/1/03
STD - 003