You are on page 1of 3

Pending Additions 1) should add sls combos (drop down list) for the sls checks (currently using

D+L)

y using D+L)

Footings Design
Designer Date Project Project no. Footing ID JL 11/19/2013 TTF-Taif 032415 5-A/B

INPUT Choose Load Combo: 2) 1.2D+1.6L

Wall Footing (Axial+Bending) *It is assumed that the designer's goal is to produce a footing with a trapezoidal stress distribution (i.e no negative stresses) *The loads input below are point loads Wall Width 250 mm Allowable B.Pressure, qa 200 KPa Concrete Grade, f'c 35 Mpa Density of Concrete, 24 kN/m3 Proposed Thickness of footing 650 mm Proposed Cover to Reinforcement 66 mm Proposed Effective depth, d 584 mm Depth of Soil above face of footing 0.82 m Density of Soil, 20 kN/m3 Axial Service Dead Load 0 kN Axial Service Live Load 1200 kN Wind Service Moment kN-m Seismic Ultimate Moment 7300 kN-m Proposed Length, L 13000 mm Proposed Width, B 3000 mm Proposed Area 39 m2 Footing Size Check Effective Bearing Pressure, qe Area required Tension Check P/A M/Z qmax qmin Strength Design P/A M/Z qmax qmin Bearing Pressure for Strength Design Lever Arm Vu d Design Moment, Mu

168 KPa 7.142857143 m2

Footing Size - OK

0.030769231 0.060473373 0.091242604 -0.02970414

MPa MPa MPa MPa

The tension in the footing is resisted by the concrete & soil-OK

0.049230769 0 0.049230769 0.049230769 49.23076923 1375 67.69230769 89.74186958 46.53846154

MPa MPa MPa MPa KPa mm kN/m mm Footing Thickness - OK kN-m/m

Bottom Reinforcement Calculation


db ds no. layers S Vertical (X-section) S Horizontal (X-section) cc f'c fy Es Mn Section is 25 mm mm 1 no. mm 200 mm 50 mm 35 Mpa 420 Mpa 200000 Mpa 637.2317789 kN-m/m O.K

Reinforcement Required Using T25@200mm produces a capacity of 637kN-m/m. Utilization Ratio is 0.07