You are on page 1of 17

METODO DE GUMBEL

AO

Q m3/sg

1981

10.90

(Qi- Qm)
91.10

1982

10.60

85.41

1983

3.50

4.58

1984

12.40

121.85

1985

7.53

1986

18.37

289.22

1987

6.11

22.54

1988

8.40

49.64

1989

10.39

81.48

10

1990

1.36

0.00

11

1991

3.00

2.68

12

1992

2.80

2.08 Qm =

13

1993

6.00

21.58

14

1994

14.55

173.87

Yn

15

1995

1.86

0.25

20

0.52355

16

1996

3.51

4.62

50

0.54854

17

1997

2.74

1.90

100

0.56002

18

1998

4.81

11.90

19

1999

6.90

30.75

20

2000

10.97

92.32

1.36

4.66

38.13 Qm =

50 Qmax =

22.176 m3/seg
25.213 m3/seg

Calculo de AQ
Q

O = 1 - 1/T
O50 =

0.98

O100 =

0.99

AQ =

1 . 14

Calculo de caudales de diseo:


Qd = 27.170

m3/seg

50

Qd = 17.183

m3/seg

100

Qd = 30.206

m3/seg

100

Qd = 20.219

m3/seg

m3/seg

2
Qi

N 2
Qm

N 1

4.66 m3/seg

4.993 m3/seg

50

7.334620833

Qmax = Qm - (Sq/Sn)(Yn-ln T)

100 Qmax =

Qm

b. Los caudales maximos y minimos se usan en:


Maximos:

Proyectos de: defensas ribereas, puentes, presas

Minimos:

Proyectos de: aprovechamiento de recursos hidricos.

2
Qi

N 2
Qm

N 1

Sn
1.06283
1.16066
1.20649

DISEO DE BOCATOMA
Alumno
Curso

Q=
Q=
Q=
Q=
Q=
S=
Z=
b=
S=
n1 =
n2 =
n3 =
Z=
nf =
np =
Fb =
Fs =
a=

: ANCHIRAICO SEDANO, Alexis


: IRRIGACIONES

30.206
7.335
1.36
1.83375
0.30
0.04
0.75
22
0.002
0.03
0.045
0.035
1.5
0.02
0.015
1.2
0.2
0.75

m3/seg
m3/seg
m3/seg
m3/seg
m3/seg

Cdigo
Facultad

DATOS:
Caudal maximo de diseo
Caudal medio del rio
Caudal minimo
Caudal ecologico
Caudal a derivarse
Pendiente del cauce del rio
Talud del rio
Ancho fisico del rio
Pendiente del Canal de derivacion
Coeficiente de Manning de la orilla de rio margen derecha
Coeficiente de Manning del fondo de rio
Coeficiente de Manning de la orilla de rio margen izquierda
Talud del canal de derivacin
Coeficiente de Manning del canal de derivacin en la base
Coeficiente de Manning del canal de derivacin en las paredes
Factor de fondo
Factor de orilla
Parametro que caracteriza al cauce

1.- ESTIMADO DEL ANCHO DE ENCAUSAMIENTO DEL RO


a) Blench:
B = 24.36692963

b) Altunin:
B = 7.846859457

c) Petit:
B = 13.9598363

Donde:
B
Q
Fb
Fs
a
S

: 2004200401 L
: Ingeniera Civil

: Ancho de encausamiento.
: Caudal maximo de diseo.
: Factor de fondo.
: Factor de orilla.
: Parametro que caracteriza al cauce.
: Pendiente del rio.

El promedio de los tres valores se puede considerar el ancho de encausamiento


B=
15.39
m
B=
15.45
m
Nota: Este valor se debe comparar con el ancho fisico del rio
medido insitu. El ancho minimo debe ser el ancho fisico del rio.
B=
22
m
2.- DETERMINACION DEL TIRANTE NORMAL DEL RIO:
Se calcula con la frmula de Manning y Continuidad:

y=

0.493

np =
6.71

0.0444
=

coeficiente de Manning ponderado del ro


OK!!!
6.71

Completamos la geometria del rio


b=
22.00 m
y=
0.493 m
Z=
0.75
A= by+zy^2
11.028
P= b+2y(1+z^2)^(1/2)
23.233
T = b+2zy
22.740
R = A/P
0.475
D = A/T
0.485
V = Q/A
2.739
F = V/(g*R)^0.5
1.269
E = y+(V^2)/(2*g)
0.875

m2
m
m
m
m
Velocidad Erosiva
m/s
Flujo Super Crtico
m-Kg/Kg

Hallamos el tirante normal Yn por tanteos con la siguiente frmula:

yn =

0.493

np =
6.71

0.0444
=

coeficiente de Manning ponderado del ro


OK!!!
6.71

Completamos la geometria del rio


B=
22.000 m
0.493 m
yn=
Z=
0.75
A= by+zy^2
11.028
P= b+2y(1+z^2)^(1/2)
23.233
T = b+2zy
22.740
R = A/P
0.475
D = A/T
0.485
V = Q/A
2.739
F = V/(g*R)^0.5
1.269
E = y+(V^2)/(2*g)
0.875

m2
m
m
m
m
Velocidad Erosiva
m/s
Flujo Super Crtico
m-Kg/Kg

3.- DISEO DE LA COMPUERTA DE REGULACIN


DETERMINAMOS EL TIRANTE NORMAL EN EL CANAL DE DERIVACIN:
Se calcula con la frmula de Manning y Continuidad:

Para condiciones de:


0.0158
0.388

np =
y1=
0.106
b=
b=

MEH : Mxima Eficiencia Hidrulica


MI : Mnima infiltracin
MEH
b=
2 *(((1+Z^2)^0.5)-Z)
b = 0.605551275 y1
coeficiente de Manning ponderado del canal de derivacin
m
0.106

OK!!!

0.234953895 m
0.30
m

Volvemos a calcular con la frmula de Manning y continuidad:

np =
y1=
0.107

0.016
0.371

coeficiente de Manning ponderado del ro


m

0.107

Completamos la geometria del rio


b=
0.300 m
0.371 m
y1 =
f=
0.3 m
Z=
1.5
A= by+zy^2
0.318
P= b+2y(1+z^2)^(1/2)
1.638
T = b+2zy
1.413
R = A/P
0.194
D = A/T
0.225
V = Q/A
0.944
F = V/(g*R)^0.5
0.684
E = y+(V^2)/(2*g)
0.416

OK!!!

2.313
1.413
m2
m
m
m
0.300
m
Velocidad sin Problemas
m/s
Flujo Subcrtico
m-Kg/Kg

0.3
0.371

4.- DIMENCIONAMIENTO DE LA VENTANA DE CAPTACIN


PREFERENTEMENTE SE DEBE DISEAR COMO VERTEDERO:

Qdem C * B * ( H 3 / 2 hv 3 / 2 )
Se desprecia la velocidad de aproximacion; por consiguiente hv = 0
El ancho a tomar varia de 3 a 4 m
C=
1.84 Coeficientre de descarga
B=
0.30 Longitud de Barraje
H=
H=

0.10 m
0.10 m

Las dimensiones de la ventana de captacion seria:


b =
0.30 m
h2=
0.10 m
5.- CALCULO DE LA ALTURA DEL BARRAJE
La altura del azud esta dado por:
P = ho + h2
Donde:
P=
Altura del azud
ho =
Altura del fondo de rio a cresta de la ventana :
h2 =
Tirante de en la ventana
0.90 m

V
g .Y

-------- 0.6 ----------0.10

0.2

------------ 0.3 -------------

-------------- 0.9 ----------------

P=

6.- LONGITUD DEL BARRAJE FIJO Y MOVIL:


a) PREDIMENCIONAMIENTO:
a.1 Por relacin de reas
El rea hidrulica del canal desarenador tiene una relacin de 1/10 del rea obstruida por el aliviadero, teniendose:

A1 = A2 /10
Ld =
Ld =
Lperf =

2
2.00
20.00

m
m
m
Barraje Movil

P = 0.9

Barraje Fijo
A1
1.8 m2

A2 = 18 m2

----Ld=2--------"

--------------------------------------------------- 20 m------------------------------------------------------

a.2 Longitud de compuertas del canal desarenador (Lcd)


N compuertas = 2
Lcd = 4Ld /(5No. Compuertas+1) =

Se usa Compuertas Comerciales:


30.00
pulg
Lcd =

0.73

a.3 Predimensionamiento del espesor del Pilar (e)


0.5
m
e = Ld/4=
e=
0.50
m
0.3
m
emin =
e = 0.50
m

0.76

28.630 Pulg

b) DIMENCIONES CALCULADAS:
0.5

P = 0.9

0.5

0.50

1.50

0.50

19.50

0.50

7.- CAPACIDAD DE DESCARGA DEL VERTEDERO


En este calculo se tendr que considerar que las compuertas deben estar abiertas ,
para ello el caudal de diseo se compartira entre el barraje movil y fijo.
"H" se calcula asumiendo un valor , calcular el coeficiente de descarga
"c" y calcular el caudal para el barraje fijo y movil
El caudal calculado debe ser igual al caudal de diseo.
Q diseo max. = Qaliviadero + Qcanal.limpia
a) DESCARGA SOBRE LA CRESTA (barraje fijo) = DESCARGA DEL ALIVIADERO (Qal)
DESCARGA EN EL BARRAJE FIJO
Qal = C * L * H^3/2
L = L1-0.1*N*h
Qal =
C =
L =
H =
L1 =
N =

Descarga del aliviadero


coeficiente de descarga
Longitud efectiva de la cresta
Carga sobre la cresta incluyendo hv
Longitud bruta de la cresta
Numero de contracciones

20.00
=
1.000

Se seguir un proceso Iterativo asumiendo


Para H:
C =
2.000
h =
0.800
m
Remplazando en la formula de "L" tenemos que:
19.92
m
L=
19.95
m
L=
Qbf =

28.55

m3/s

DESCARGA EN EL BARRAJE MOVIL


Qd= Cd * A*(2*g*y)

L = L1-0.1*N*h
Y1 =
Y2 =
a=
Y1/a =
Y2/a =
Cd =
b=

1.70
1.70
0.90
1.888888889
1.888888889
0.54
0.5

m
m
m

Remplazando en la formula tenemos que:


Qbm =
2.81
m3/s
Qt =

31.36
m3/s
>
30.206
El valos de h= 0.8 m. asumido es correcto

m3/s

8.- DETERMINAMOS LOS TIRANTES Yo, Y1 y Y2 DEL BARRAJE MEDIANTE ITERACIONES:

h (m)
0.8000

r (m)
0.08

Q (m3/s)
29.906

Tanteo
Y1 (m)
0.275

Verificacin
OK!!!

V1 (m/s) E1 (m*Kg/Kg)
5.441203
1.784005
Del tanteo tenemos:
29.906
Qmax =
20.000
Lperf =
h = Yo =
0.800
0.275
Y1 =
5.441
V1 =
1.784
E1 =
1.158
Y2 =

Lperf (m)
20.00

P (m)
0.90

Igualdad
1.78
1.78
Y2 (m)
1.158

m3/s
m
m
m
m/s
m*Kg/Kg
m

Eo (m*Kg/Kg)
1.78

9.- DISEO DEL PERFIL CREAGER:


Hd =
0.800
P=
0.90
0.08
a =
Vo =
1.869
PENDIENTE DE RECTA z =
1.5
A=
0.166685
Variacin de tanteo =
Copiar aqu --- A=
0.19796
Htotal =

RESULTADOS

m
m
m
m/s

--- Este valor copiar manualmente abajo


0.00001

0.9840054 m
RADIOS

R1 =
R2 =
R3 =

0.16 m
0.4 m
0.487 m

PERFIL CREAGER

PARED

0.8

-0.9
-0.9

-1.2256
-0.2256

0.8
0.8

EJE Y

-1.2256
-0.2256

-2

R1 = 0.16 m

0.6

1.8734967 -0.984
3.8734967 -0.984

0.4
0.2
0

-1

0
-0.2
-0.4
-0.6

1.8734967
2.2068301
2.5401634
1
2.8734967
3.2068301
3.5401634
3.8734967

-0.7738
-0.7351
-0.5146
2
-0.3087
-0.2624
-0.2493
0.17418

R2 = 0.4 m

CURVA

PENDIENTE DE
RECTA z = 1.5
R3 = 0.487 m

Espejo de agua

Losa Aguas Arriba

-0.8
-1

Losa Aguas Abajo

-1.2

EJE X

9.- CALCULO DE LA LONGITUD DEL COLCHON DISIPADOR:


0.275
m
Y1 =
5.441
m/s
V1 =
1.784
m*Kg/Kg
E1 =
1.158
m
Y2 =
Determinamos el Numero de Froude
F

Tipo Tanque
S.T
I
II
III, IV

1.7 a 2.5
2.5 a 4.5
F=
3.31
Se requiere Tanque Tipo II
4.50
DISEO DE UN ESTANQUE TIPO II (2,5 Fr1 4,5), ( V1 < 15 m/s) -- VER HOJA DE TANQUE TIPO II
a.- CALCULO DE LA LONGITUD DEL COLCHON DISIPADOR:
Se determina con los valores de d1 y d2 calculados
L = 4 Y2
U.S Bureau Of Reclamation
L = 5(Y2-Y1)
Baklmnetev - Martzke
L = 4.5 Y2
Lafranetz
L = 2.5(1.4 Y2-Y1)
Paulosky
L = 4 Y2
L = 5(Y2-Y1)
L = 4.5 Y2
L = 2.5(1.4 Y2-Y1)
Lprom =
L=

4.45

4.63
4.42
5.21
3.37
4.41 m
m

m
m
m
m

X
-0.2256
-0.2256
-0.2256
-0.223888
-0.219893333
-0.2149
-0.2042
-0.1935
-0.1828
-0.1721
-0.1614
-0.1507
-0.14
-0.14
-0.1225
-0.105
-0.0875
-0.07
-0.0525
-0.035
-0.0175
-0.009333333
-0.0028
0
0
0.05445
0.1089
0.16335
0.2178
0.27225
0.3267
0.38115
0.4356
0.49005
0.5445
0.5445
0.650385774
0.756271548
0.862157322
0.968043096
1.07392887
1.179814644
1.285700418
1.391586192
1.497471966
1.60335774
1.60335774
1.63037164
1.657385539
1.684399439
1.711413338
1.738427238
1.765441137
1.792455037
1.819468936
1.846482836
1.873496736

Y
-0.9
-0.166949829
-0.166949829
-0.143606542
-0.1245993
-0.109421488
-0.087012103
-0.07081664
-0.058027104
-0.047544008
-0.038800073
-0.031458169
-0.02530012
-0.02530012
-0.019219551
-0.014027203
-0.009687625
-0.006172627
-0.003460279
-0.001534192
-0.000382996
-0.000108904
-9.80012E-06
0
0
-0.002772934
-0.009996434
-0.021164788
-0.036037162
-0.054454542
-0.0762991
-0.101477784
-0.129914037
-0.161543037
-0.196308724
-0.196308724
-0.26689924
-0.337489756
-0.408080272
-0.478670788
-0.549261304
-0.61985182
-0.690442336
-0.761032852
-0.831623368
-0.902213884
-0.902213884
-0.918975992
-0.933428295
-0.945793996
-0.956241683
-0.964899856
-0.97186641
-0.977214973
-0.980999189
-0.983255583
-0.984005391

Y'
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.773227066
0.742723566
0.716500812
0.686875126
0.6539995
0.617985862
0.585864328
0.550554654
0.512120967
0.470618639
0.463949366
0.373551107
0.270938074
0.15775761
0.036241684
-0.085840079
-0.20740693
-0.323366384
-0.438006014
-0.550590019
-0.660525204
-0.667775864
-0.691571112
-0.710571513
-0.72739435
-0.740462833
-0.751494573
-0.76059518
-0.767000099
-0.770784315
-0.773040709
-0.773790517

1
0.97
0.97
0.98
0.98
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.97
0.95
0.93
0.91
0.9
0.89
0.89
0.88
0.87
0.86
0.97
0.97
0.98
0.98
0.988
0.989
0.99
0.995
1
1
1

METODO DIRECTO POR TRAMOS


DATOS:
Q=
30.206 m3/s
n=
0.0444
So =
0.04
b=
22 m
Z=
0.75
Y
1
0.493
0.614
0.734
0.855
0.976
1.097
1.217
1.338
1.459
1.579
1.700

A
2
11.03
13.78
16.56
19.36
22.18
25.02
27.89
30.78
33.68
36.62
39.57

Yinicial
Yfinal

=
=

V^2/(2g)

R^2/3

3
23.3044
23.6237
23.9430
24.2624
24.5817
24.9011
25.2204
25.5398
25.8591
26.1784
26.4978

4
0.4747
0.5857
0.6948
0.8021
0.9076
1.0115
1.1137
1.2143
1.3134
1.4111
1.5073

5
0.6085
0.7000
0.7845
0.8633
0.9374
1.0076
1.0744
1.1382
1.1993
1.2581
1.3146

6
2.74
2.19
1.82
1.56
1.36
1.21
1.08
0.98
0.90
0.82
0.76

0.493 m
1.70 m

7
0.3824
0.2448
0.1696
0.1241
0.0945
0.0743
0.0598
0.0491
0.0410
0.0347
0.0297

E
8
0.8754
0.8585
0.9040
0.9792
1.0703
1.1708
1.2770
1.3870
1.4996
1.6140
1.7297

E
9
0.0000
-0.0169
0.0455
0.0752
0.0911
0.1004
0.1062
0.1100
0.1126
0.1144
0.1157

SE

SE-S0

10
11
12
13
14
0.0399380453 0.00000 0.04000 0.0000 0.00
0.0193188921 0.0296 0.01037 -1.6291 -1.63
0.0106565053 0.0150 0.02501 1.8186 0.19
0.0064390076 0.0085 0.03145 2.3914 2.58
0.0041599695 0.0053 0.03470 2.6267 5.21
0.0028288917 0.0035 0.03651 2.7515 7.96
0.0020032147 0.0024 0.03758 2.8264 10.79
0.0014658264 0.0017 0.03827 2.8749 13.66
0.0011020681 0.0013 0.03872 2.9080 16.57
0.0008476635 0.0010 0.03903 2.9315 19.50
0.0006647567 0.0008 0.03924 2.9487 22.45

CURVA DE REMANSO
1.800

1.600
1.400
1.200

1.000
0.800

0.600
0.400

0.200
0.000

-5.00

0.00

5.00

10.00

15.00

20.00

25.00

DISEO DE UN ESTANQUE TIPO I (1,7 Fr1 2,5)


Autor: ANCHIRAICO SEDANO, Alexis
1.- Calcular el valor de TA de la siguiente ecuacin
TA = Y1 ( 1,539 Fr1 - 0,471 )
Y1 =
m
0.28
Fr =
3.31
TA =
1.27
2.- Calcular el tirante conjugado (Y2)

Y2 =

1.16

3.- Determinar la longitud del estanque amortiguador (LI)

6.30273337 m
m
6.35

4.- Calcular las dimensiones de los dientes deflectores.


Altura = 2*Y1 =
0.55 m
Ancho = Y1 =
0.28 m
Largo = Constructivo hasta cimacio
Espacio entre dientes = 2.5*Y1 =
0.69 m

Constructivo hasta cimacio


0.55 m

LI =
LI =

0.28 m
5.- Calcular el nmero de dientes (n).
n = ( b + 2,5 Y1 )/ ( 3,5 Y1 )
b=
20.00 m
n = 21.4935065
n=
dientes
21.00
6.- Calcular el espacio fraccional entre la pared y el diente deflector ms prximo a ella.
Espacio fraccional = [ b - (3,5 Y1 * n - 2,5 Y1 )] / 2
Espacio Fraccional =
0.24 m

7.- Obtener el dimensionamiento del umbral terminal.


L = 2,5 Y1 + 0,04 Y2
En la figura anterior (c) se presenta el dimensionamiento del umbral terminal.
L=
0.73
L=
m
0.75
8.- Dibujar y dimensionar el estanque amortiguador obtenido

DISEO DE UN ESTANQUE TIPO II (2,5 Fr1 4,5), ( V1 < 15 m/s)


Autor: ANCHIRAICO SEDANO, Alexis
1.- Calcular el valor de TA de la siguiente ecuacin
TA = Y1 ( 1,420 Fr1 - 0,604 )
Y1 =
m
0.28
Fr =
3.31
TA =
1.13
2.- Calcular el tirante conjugado (Y2)

Y2 =

1.16

3.- Determinar la longitud del estanque amortiguador (LII)

2.46802089 m
m
2.50

4.- Calcular las dimensiones de los dientes deflectores.


Altura = Y1 =
0.55 m
Ancho = Y1 =
0.28 m
Largo = 2*Y1 = Constructivo hasta cimacio
Espacio entre dientes = Y1 =
0.28 m
Espacio fraccional = 0.5*Y1 =
0.14 m

Constructivo hasta cimacio


0.55 m

LII =
LII =

0.28 m

5.- Calcular el nmero de dientes (n).


n = b / (2Y1)
b=
20.00 m
n = 36.3636364
n=
dientes
36.00
6.- Clculo de las dimensiones de los dados amortiguadores.
a) Clculo de h3 de la siguiente expresin:
h3 = Y1 ( 0,545 + 0,175 Fr1 )
h3 =
0.30919325
h3 =
m
0.35

b) Clculo de las dimensiones de los dados amortiguadores


Altura = h3 =
0.35 m
Ancho = 0,75 h3 =
0.26 m
Largo = 1,2 h3 =
0.42 m
Ancho superior = 0,2 h3 =
0.07 m
Espacio entre dados = 0,75 h3 =
0.26 m
Espacio Fraccional = 0,375 h3 =
0.13 m

d2 =
Ubicacin = 0,8 d2 =

2.49 m
1.992 m

c) Clculo del nmero de dados amortiguadores (n)


n = b / (1,5 h3 )
n=
38.10
n=
dados
38.00
7.- Clculo de las dimensiones del umbral terminal.
a) Clculo de h4 a partir de la siguiente expresin
h4 = Y1 (0,956 + 0,063 Fr1 )
h4 =
m
0.32
h4 =
m
0.35
b) Clculo de las dimensiones del umbral terminal.
Altura = h4 =
0.35 m
Ancho cara superior umbral = 0,04 h4 =
0.01 m
Largo = 2,04 h4 =
0.71 m
8.- Dibujar y dimensionar el estanque amortiguador obtenido

DISEO DE UN ESTANQUE TIPO III (Fr1 > 4,5 ) ; (V1 > 15 m/s).
Autor: ANCHIRAICO SEDANO, Alexis
1.- Calcular el valor de TA de la siguiente ecuacin
TA = Y1 (1,469 Fr1 - 0,318)
Y1 =
m
0.28
Fr =
3.31
TA =
1.25
2.- Calcular el tirante conjugado (Y2)

Y2 =

1.16

3.- Determinar la longitud del estanque amortiguador (LIII)

LIII =
LIII =

4.3370495 m
m
4.35

4.- Calcular las dimensiones de los dientes deflectores.


Altura = Y1 =
0.55 m
Ancho = Y1 =
0.28 m
Largo = 2*Y1 = Constructivo hasta cimacio
Espacio entre dientes = Y1 =
0.28 m
Espacio fraccional = 0.5*Y1 =
0.14 m

5.- Calcular el nmero de dientes (n).


n = b / (2Y1)
b=
20.00 m
n = 36.3636364
n=
dientes
36.00

Constructivo hasta cimacio

6.- Clculo de las dimensiones del umbral terminal


Altura = 0,2Y2 =
0.23 m
Ancho = 0,15 Y2 =
0.17 m
Espacio entre dientes = 0,15 Y2 =
0.17 m
Ancho superior del diente = 0,02 Y2 =
0.02 m
En la figura anterior (b) se representan estos parmetros.
7.- Dibujar y dimensionar el estanque amortiguador obtenido

0.55 m

Constructivo hasta cimacio

0.28 m