CALCULO DE LA RED DOMICILIARIA DE AGUA POTABLE

TRAMO

CAUDAL
CAUDAL
LONG
N
INSTALADO MAX PROB DIAM VELOC REAL CODO
(l/m)
(l/m)
(mm) (m/s)
(m)

1-2

164

58.4

32

1.21

7.4

1.0

2-3

144

53.4

25

1.82

7.7

1.0

3-4

75

34.1

19

2.01

1.0

4-5

33

25.0

19

1.47

3.0

1.0

5-6

15

15.0

19

0.88

2.0

3.0

N
TEE
DIR

N
N
LONG LONG
TEE
VALV EQUIV TOTAL
LAT/BIL GLO
(m)
(m)

J
UNIT
(m/m)

J
TOT
(mca)

PIEZOMET
INICIAL
(m)

1.61

9.01 0.0588

0.53

114.00

2.0

3.77

11.47 0.1626

1.87

113.47

1.0

1.09

2.09 0.2728

0.57

111.60

1.0

6.55

9.55 0.1586

1.51

111.03

1.0

6.56

8.56 0.0648

0.56

109.52

1.0

1.0

CELDAS RESALTADAS EN AMARILLO: DATOS QUE DEBE PROPORCIONAR EL USUARIO


PRIMERA COTA PIEZOMETRICA INICIAL = COTA DE TERRENO EN SOLERA FRENTE AL MEDIDOR + PRESIN RED PBLICA (14mca)

PIEZOMET COTA PRESION


FINAL
ARTEF DISPONIB
(m)
(m)
(mca)
113.47 100.20

13.27

111.60 100.20

11.40

111.03 100.20

10.83

109.52 102.85

6.67

108.96 104.65

4.31

CALCULO DE LA RED DOMICILIARIA DE AGUA POTABLE CALIENTE


TRAMO

CAUDAL
CAUDAL
LONG
N
INSTALADO MAX PROB DIAM VELOC REAL CODO
(l/m)
(l/m)
(mm) (m/s)
(m)

1-2

114

45.5

25

1.55

1.5

1.0

2-3

65

30.9

19

1.82

1.0

3-4

23

23.0

19

1.35

3.0

1.0

4-5

15

15.0

19

0.88

2.0

3.0

N
TEE
DIR

N
N
LONG LONG
TEE
VALV EQUIV TOTAL
LAT/BIL GLO
(m)
(m)
1.0

1.0

1.0
1.0

J
UNIT
(m/m)

J
TOT
(mca)

PIEZOMET
INICIAL
(m)

9.02

10.52 0.0988

1.04

111.60

1.09

2.09 0.1848

0.39

110.56

1.0

6.55

9.55 0.1104

1.05

110.17

1.0

6.56

8.56 0.0522

0.45

109.12

CELDAS RESALTADAS EN AMARILLO: DATOS QUE DEBE PROPORCIONAR EL USUARIO

NTE
PIEZOMET COTA PRESION
FINAL
ARTEF DISPONIB
(m)
(m)
(mca)
110.56 100.30

10.26

110.17 100.30

9.87

109.12 102.85

6.27

108.67 104.65

4.02