Fault detection
Automatic
Fault analysis measures by
EWSD
Fault signalling System
Alarm confirmation
manual
measures by
Fault clearance with O&M staff
Diagnosis and removal
Fig 1.0
MML - CMD to read contents of HF.ARCHIVE file.
SWITCHING NETWORK SN
MESSAGE BUFFER MB
CENTRAL UNITS CU
RECOVERY RECOV
SGC DEFECT
FAULT LOCATION:TSG-side-tsgSGC
CONFIGURATION:TSG-side-tsgFROM: zzz TO: UNA
SUPPLEMENTRY INFORMATION
H’ zzzzzzzz zzzzzzzz zzzzzzzz zzzzzzzz
H’ zzzzzzzz zzzzzzzz zzzzzzzz zzzzzzzz
General Procedure for fault clearance in EWSD
SYP 100
N
Alarm END of procedure
Present
at
Y N
Buzzer at SYPD on
Y
Press accept-key
Set up session to exchange
NP means NOT PROCESSED
DISP ALARM: ALSTAT = NP,
(ALARMS)
OBJECT = xxx
MSGNO is taken from the output of DISP ALARM cmd..
SRCH ALARM : MSGNO = xxx;
SET ALSTAT : MSGN = xxx, IP means IN PROCESS i.e. ALARM is being processed.
ALSTAT = IP
DACT OUTSUP means output suppression on OMT has been
DACT OUTSUP:
deactivated
LOCDEV =Systemdevice-FUOMT,
Fault clearance Relevant MMN details are taken from
According to MMN the fault message/printout.
SYP101 is a standard procedure for ending the HW fault clearance.
SYP 100
SRCH ALARM
MSGNO = xxx;