You are on page 1of 4

"U" Value Reference Table

http://www.combustionresearch.com/Infra-Spec/infra-spec/uvalue.html

Reference Table for "U" Values "U" Value is the coefficient of transmission, i.e., the transmission of heat through the materials, which compose the building's "envelope," or outer shell. "U" Value has an inverse relationship to "R" Value. For example, a building with material with an "R" Value of R-11 converts to an "U" Value of 0.09 ( 1/R or 1/11 = 0.09). The following is a table of common materials and their corresponding "U" Value.
Go back to Heat Loss Calculation.

Walls
Material Flat Metal Description 0" Fiberglass Insulation 1" Fiberglass Insulation 2" Fiberglass Insulation 3" Fiberglass Insulation 4" Fiberglass Insulation 6" Fiberglass Insulation 8" Fiberglass Insulation 12" Fiberglass Insulation Masonry 8" Brick 12" Brick 16" Brick 8" Conic Block, Solid 12" Conic Block, Solid 4" Conic Block, Hollow 8" Conic Block, Hollow 12" Conic Block, Hollow Poured Concrete (140 lb. / ft3) 2" Thick 4" Thick 6" Thick 8" Thick 10" Thick "U" Factor 1.20 0.22 0.12 0.09 0.07 0.05 0.041 0.027 0.41 0.31 0.25 0.39 0.36 0.51 0.39 0.37 0.99 0.86 0.75 0.67 0.61

1 of 4

1/2/2013 07:52

"U" Value Reference Table

http://www.combustionresearch.com/Infra-Spec/infra-spec/uvalue.html

12" Thick Poured Concrete (80 lb. / ft.3) 2" Thick 4" Thick 6" Thick 8" Thick 10" Thick 12" Thick Go back to Heat Loss Calculation. Doors Material Steel Description No Fiberglas Insulation Insulated Wood 1" Thick Go back to Heat Loss Calculation. Roofs Material Flat Metal - Roof Description 0" Fiberglass Insulation 1" Fiberglass Insulation 2" Fiberglass Insulation 3" Fiberglass Insulation 4" Fiberglass Insulation 6" Fiberglass Insulation 8" Fiberglass Insulation 12" Fiberglass Insulation Wood - Roof 0" Fiberglass Insulation 1" Fiberglass Insulation 2" Fiberglass Insulation 3" Fiberglass Insulation 4" Fiberglass Insulation 6" Fiberglass Insulation

0..55 0.62 0.42 0.31 0.25 0.21 0.18

"U" Factor 1.20 0.65 0.64

"U" Factor 0.90 0.26 0.16 0.11 0.071 0.05 0.039 0.027 0.48 0.21 0.12 0.10 0.075 0.052

2 of 4

1/2/2013 07:52

"U" Value Reference Table

http://www.combustionresearch.com/Infra-Spec/infra-spec/uvalue.html

8" Fiberglass Insulation 12" Fiberglass Insulation Concrete Deck - Roof 2" Thick 3" Thick 4" Thick Sky Lights Single Wall Double Wall Go back to Heat Loss Calculation. Floors - Exterior Exposure Material Floor - Exterior exposure Description Insulated Un-Insulated Go back to Heat Loss Calculation. Windows Material Glass Description Single Pane Double Pane Fiberglass Panels Go back to Heat Loss Calculation. Cold Mass Specific Gravity Material Steel Aluminum Copper Cast Iron Cement Concrete (140# / ft3) Sand & Stone Glass Specific Gravity 0.12 0.23 0.09 0.11 0.19 0.16 0.19 0.16

0.04 0.027 0.30 0.23 0.18 1.15 0.70

"U" Factor 0.55 0.81

"U" Factor 1.22 0.70 1.09

3 of 4

1/2/2013 07:52

"U" Value Reference Table

http://www.combustionresearch.com/Infra-Spec/infra-spec/uvalue.html

Rubber Wood

0.48 0.50

Go back to Heat Loss Calculation.

4 of 4

1/2/2013 07:52