You are on page 1of 10

183168711.xls.

ms_office

CONTROL VALVE SIZING by S. Jane Stone Nomenclature P1 P2 Delta P Pv G

Based on Masonelian Method January '94

Upstream Pressure Downstream Pressure P1 - P2 Vapour Pressure Gas s.g. at S.C.

Cf Cv del Ps Pc Gf

Critical Flow Factor Valve Flow Coefficient Pressure drop for critical flow calculations Critical Pressure Gas s.g. at flowing temperature

Liquids
Job No. Tag No. Service Flow (gpm) P1 (psia) Delta P (psi) Fluid s.g. Fluid Pv (psia)

XXXX 76997 64294 64294

CV-XXX

LIQUID - Calc CV Cooler water TT heater water valve(sum) TT heater water valve(win)

48 56 485 39

45 40 40 40

5 5 10 10

1 1 1 1

15.64 15.64 3 3

XXXX

CV-XXX

LIQUID - Calc Delta P

48

45

15.64

XXXX

CV-XXX

LIQUID - Calc flow

48

45

15.64

INSTRUCTIONS 1 2 3 4 5 Press F5 and select whichever calculation you want to use (for example LIQUID-CalcCV) Pick Edit Copy Move the cursor to the line you want to copy to in the column under Job No. Pick Edit Insert Paste (it will ask you if you want to Shift Cells Down - pick OK) Enter values in all the cells with yellow backgrounds - other values will be calculated. FOR MORE INFO PRESS F5 and SELECT NOMENCLATURE

Page 1

183168711.xls.ms_office

Fluid Pc (psia)

Valve Cf

Check for Critical Flow Condition (cavitation or flashing) Flow del Ps Critical? Cv (psi)

Saturated Steam
Job No 67194 67194 63593 67194 76997 XXXXX XXXXX

Notes

3206 3206 3206 3206

0.75 0.75 1 1

NO NO NO NO

21.5 25.0 153.4 12.3

44.35 39.35 39.07 39.07

3206

0.75

NO

21.5

44.35 XXXXX 74896 76397 XXXXX

3206

0.75

NO

21.5

44.35

Page 2

183168711.xls.ms_office

Saturated Steam
Tag No Service Flow lb/hr 25600 106000 2590 15000 600 1000 1000 P1 (psia) 19.7 19.7 85 20 85 85 85 Delta P (psi) 5 5 37 5 5 10 10 Valve Cf 0.65 0.65 0.75 0.75 0.75 0.75 0.75

Check for Critical Flow Condition Cv 1092.5 4523.5 22.2 539.9 9.9 11.9 11.9 Flow Critical? YES YES YES NO NO NO NO

CANADA SALT OUTLET ADM OUTLET CV-105/205 Steam to water injector heater Steam line purge ster Sterlilizer steam CV-XXX CV-XXX SAT'D STEAM - Calc Cv SAT'D STEAM - Calc Delta P

CV-XXX

SAT'D STEAM - Calc Flow Steam to kettles PV804A-C Booster motive steam, 10" PV804D Booster motive steam, 4"

1000 6492 116563 22514

85 150 150 150

10 35 1 1

0.75 0.75 0.75 0.75

11.9 32.1 3210 620

NO NO NO NO

Page 3

183168711.xls.ms_office

Critical Flow Condition P2 (psia) 14.7 14.7 48 15 80 75 75 170 -1601.28

Gases
Job No Tag No

Notes

XXXXX XXXXX XXXXX 63593 XXXXX

CV-XXX CV-XXX CV-XXX Air CV-XXX

75 115 149 149

Page 4

183168711.xls.ms_office

Check for Critical Flow C Service Flow lb/hr Gas M.W. Temp (deg F) P1 (psia) Delta P (psi) Valve Cf Cv

GASES - Calc Cv GASES - Calc Delta P GASES - Calc Delta P Cylinder lift GASES - Calc Flow

15000 1000 1000 156 997

18 18 18 29 18

250 316 316 70 316

20 85 85 85 85

5 10 10 5 10

0.75 0.75 0.75 0.75 0.75

522.3 12.0 12.0 1.7 12

Page 5

183168711.xls.ms_office

Check for Critical Flow Condition at s.c.=32F, 14.7 psia Flow Gas s.g. Gf Critical? G

P2 (psia)

Notes

NO NO NO NO NO

0.62069 0.62069 0.62069 1 0.62069

0.45459 0.415926 0.415926 0.981132 0.415926

15 75 75 80 75 170 170 -1610.31 -1610.31

Page 6

183168711.xls.ms_office

Superheated Steam
Job No Tag No Service Flow lb/hr P1 (psia) Delta P (psi) Valve Cf

XXXXX XXXXX XXXXX XXXXX XXXXX

CV-XXX CV-XXX CV-XXX CV-XXX CV-XXX

SUPERHTD STEAM - Calc Cv SUPERHTD STEAM - Calc Delta P SUPERHTD STEAM - Calc Delta P SUPERHTD STEAM - Calc Flow SUPERHTD STEAM - Calc Flow

1000 1000 1000 1000 1000

85 85 85 85 85

10 10 10 10 10

0.75 0.75 0.75 0.75 0.75

Page 7

183168711.xls.ms_office

Check for Critical Flow Condition Superheat (deg F) Cv Flow Critical? P2 (psia)

Notes

0 0 0 0 0

11.9 11.9 11.9 11.9 11.9

NO NO NO NO NO

75 75 75 75 75 170 170 -1601.28 -1601.28

Page 8

183168711.xls.ms_office

Laminar Flow of Liquids


Job No. Tag No. Service Flow (gpm) P1 (psia) Delta P (psi) Fluid s.g.

XXXX XXXX

CV-XXX CV-XXX

LAMINAR LIQUID - Calc CV LAMINAR LIQUID - Calc Delta P

48 48

45 45

5 5

1 1

XXXX

CV-XXX

LAMINAR LIQUID - Calc flow

48

45

Page 9

183168711.xls.ms_office

Fluid Visc (cp)

Fluid Pv (psia)

Fluid Pc (psia)

Valve Cf

Check for Critical Flow Condition (cavitation or flashing) Required Turbulent Laminar Cv Cv Cv

del Ps (psi)

Notes

1000 1000

15.64 15.64

3206 3206

0.75

32.5

9.6

32.5 32.5

44.35 44.35

0.75 CV goes in Laminar Col

1000

15.64

3206

0.75 CV goes in Laminar Col

32.5

44.35

Page 10

You might also like