COEFICIENTE PARA CALCULAR MOME

Carga P =

3500.00

Kg/m2

4.50

0.1

0.2

Coeficiente Radiale

0.075

0.073

0.067

Momentos Radiale

5,316

5,174

4,749

Coeficiente Tangenciales

0.075

0.074

0.071

Momentos Tangenciales

5,316

5,245

5,032

Radio de la loza =

A CALCULAR MOMENTOS EN LOSAS CIRCULARES

0.3

0.4

0.5

0.6

0.7

0.8

0.057

0.043

0.025

0.003

0.023

0.053

4,040

3,048

1,772

213

1,630

3,756

0.066

0.059

0.05

0.039

0.026

0.011

4,678

4,182

3,544

2,764

1,843

780

ES

0.9

0.087

0.125

6,166

8,859

0.006

0.025

425

1,772

F L E X U R A L
Ma

Ms

Probando con Armadura

b, ancho de la viga

Cover

h, altura total de la viga

d=h-Cover-0.5db

f'c

fy

f, para flexin

Mu =1.3x1.7x 3610.18 = 2.21x3610.18

Mu/(f*f'c*b*d^2)

f*f'c*b*d^2

Indice de refuerzo w

RUN

Mu=j*[b*d^2*f'c*w*(1-0.59*w)]

As=w*b*d*f'c/fy

a=d-(d^2-2*|Mu|/(0.85*f'c*j*b))^0.5

As=Mu/(j*fy*(d-0.5*a))

As,min=((3*(f'c)^0.5)/fy)*b*d

As,min=(200/fy)*b*d

=
#8

Yb, Altura entre lechos de varillas

Ycb=Yb+0.5*dbs+0.5*dbi

Y'

S T R E N G

d', Peralte al centroide de lechos

=
#8

As, Lecho Superior (dbs)

As, Lecho Inferior (dbi)

As,total

a=(As*fy)/(0.85*f'c*b)

Mu=j*As*fy*(d'-0.5*a)

r=As/b*d'

r=200/fy

Momento Flector por Carga

Momento Flector por Area de Acero

F.S = Mur/Mu = 9778.5/7978.48

Elaborad

E X U R A L

S T R E N G T H
41,593.75 kg-m
300.848 ft.-kips, 3610.17 in.-kips
1/1 in. = 2.5 cm
12 in. = 30 cm
2.00 in. = 5 cm
52 in. = 130 cm
49.938 in. = 124.84 cm
4 ksi. = 281.20 kg/cm2
60 ksi. = 4,218.40 kg/cm2
0.9 Flexin
7,978.48 in.-kips
0.0741
107730.17

RESET

0.078
0.00 in.-kips
3.101 in2
4.56 in. = 11.398 cm
3.100 in2
1.89 in2 (Ecuacin ACI 10-3)
2.00 in2 (Ecuacin ACI 10-3)

2.00

2#8 Lecho Superior (dbs)

0.00

in. = 0 cm

1.00

in. = 2.5 cm

3.00

in. = 7.5 cm

49.00

in. = 122.5 cm

3.00

3#8 Lecho Inferior(dbi)


1.57 in2
2.36 in2
3.93 in2
5.77 in. = 14.437 cm
9778.50 in.-kips, Momento Resistente
0.0067
0.0033
7,978.48 in.-kips
9,778.50 in.-kips
1.23 F.S > 1.10 OK!!

Elaborado por: Ing. Johnny ngel Calero Cuadra.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

CONTRAFUERTE EXT

25
26

CONTRAFUERTE EX

27
28
29
30
31
32
33
36
37
38

CONTRAFUERTE EX

39
40

CONTRAFUERTE INTERIOR

NTRAFUERTE EXTERIOR DEL MURO (Mz)

ONTRAFUERTE EXTERIOR DEL MURO

ONTRAFUERTE EXTERIOR DEL MURO

UERTE INTERIOR DE LOS MUROS CENTRALES

ACI 350-01 - FLEXURAL STRENGTH DESIGN METHOD


MOMENTO FLECTOR M11-M22

1,942.42 kg-m/m

Mu =1.3x1.7x 1942.416043

4,292.74 kg-m/m

Momento Actuenate

db, dimetro de varilla

3/4 in. = 1.875 cm

b, ancho de losa o muro para anlisis

12 in. = 30 cm

cover

2 in. = 5 cm

h, espesor de losa o muro

8 in. = 20 cm

d=h-cover-(db/2)

5.625 in. = 14.06 cm

f'c

3 ksi. = 210.90 kg/cm2

fy

40 ksi. = 2,812.30 kg/cm2

0.9 Factor de reduccin a flexin

Mu =1.3x1.7x 51.37

Mu/( j*f'c*b*d^2)

0.1107

l= j*f'c*b*d^2

1025.16

Indice de refuerzo w

0.119

l*(1-0.59*w)*w

113.53 in.-kips/ft

As=w*b*d*f'c/fy

0.60 in 2 /ft

a=d-(d^2-2*|Mu|/(0.85*f'c*j*b))^0.5

0.79 in. = 1.97 cm

b 1=0.85-0.05*((f'c-4000)/1000)

0.85 0.65 b1=0.9 0.85

cb=(87000/(87000+fy))*d

3.85 in. = 9.6 cm

amax=0.75* b 1*cb

If a=0.79in amax=2.46in, entonces

As=Mu/(j*fy*(d-a/2))

0.60 in 2 /ft

As,min=((3*(f'c)^0.5)/fy)*b*d

0.28 in 2 /ft

As,min=(200/fy)*b*d

0.34 in 2 /ft

4.281 ft.-kips, 51.37 in.-kips

113.53 in.-kips/ft

2.46 in. = 6.1 cm


OK!!!

#6

8.00

in. = 20 cm. Refuerzo General

#0

8.00

in. = 20 cm. Dobelas

As,general

0.66 in 2 /ft

As,dobelas

0.00 in 2 /ft

As(total)

0.66 in 2 /ft

a=(As(total)*fy)/(0.85*f'c*b)

0.87 in. = 2.166 cm

Mu= j*As(total)*fy*(d-a/2)

123.86 > 113.54 in.-kips/ft [ 8.34%]

Anlisis del Control de Grietas. Alternate (Working Stress) Design Method. ACI 350-01
Momento Actuenate

n = 29,000/[57 (f'c=3)1/2]

r = As(total)/b*d

0.0098

0.3455

j = 1-(k/3)

0.8848

fs = Ma/(As*j*d)

k = [(2 r n + ( r n)^2)]

1/2

- rn

51.37 in.-kips/ft

15.58 ksi, Fs = 20 ksi, para Grado 40

fc = (2*Ma)/(k*j*b*d )

0.89 ksi, Fc = 1.35 ksi, para f'c = 3 ksi.

dc = 2 + 0.375

2.0469 in. = 5.1 cm

A = 2*dc*bw

32.750 in 2

z = fs*(dc*A) 1/3

63 kip/in

Z, para un ancho de grieta de 0.254mm

115 kip/in

Elaborado por: Ing. Johnny ngel Calero Cuadra.

N.Bar

3.00

D.Bar

0.38

pulg

0.03

pie

A.Bar

0.11

pulg2

0.0008

pie2

Peso volumetrico del acero

490.00

lb/pie3

Peso/pies de refuerzo

0.38

lb/pie

Longitud de la varilla

20.00

pie

6.00

qq

100.00

lb

Peso .Bar

7.52

lb

Numero de varillas/diametro

13.30

Bar

14.00

Bar

Costo US$/lb

0.42

Longitud total de refuerzo

Mano de Obra

0.21

Peso/pie del armado

Costo

0.63

L(pie)
Quintales de acero

Factor de desperdicios

0.05

%
Longitud total de refuerzo

Refuerzo de #2

0.40

US$/lb

Peso/pie del armado

Refuerzo de #3

0.60

US$/lb

L(pie)

Refuerzo de #4

0.80

US$/lb

Quintales de acero

Refuerzo de #5

1.00

US$/lb

Refuerzo de #6

1.20

US$/lb

Longitud total de refuerzo

Refuerzo de #8

1.60

US$/lb

Peso/pie del armado


L(pie)
Quintales de acero

Dia

Dia

Bar

C$/QQ

Refuerzo de #2

1/4 pulg

6.35 mm

30.00

645.06

Refuerzo de #3

3/8 pulg

9.525 mm

14.00

701.71

Refuerzo de #4

1/2 pulg

12.7 mm

8.00

688.40

Refuerzo de #5

5/8 pulg

15.875 mm

5.00

688.50

Refuerzo de #6

6/8 pulg

19.05 mm

4.00

814.60

Refuerzo de #8

1 pulg

25.4 mm

2.00

724.60
723.56

0.38

lb/pie

22.96

pie

8.62895 lb

1.04

lb/pie

pie

lb

1.50

lb/pie

pie

lb

8.63

lb

0.00

lb

0.00

lb

TASA

IVA

US$/QQ

19.41

1.15

38.22

19.41

1.15

41.57

19.41

1.15

40.78

19.41

1.15

40.79

19.41

1.15

48.26

19.41

1.15

42.93
42.09