You are on page 1of 173

CLASS A General Items

Item No. Code No. A100 Description CONTRACTUAL REQUIREMENTS Bond A111 A112 Performance Bond. Design Guarantee Bond [for roof structure (to be designed by the Contractor) of (..)]. Insurances A121 A122 A123 Insurance of the Works. Public Liability Insurance. SOCSO/Workmen Compensation Insurance. Statutory Obligations A131 A140 CIDB Levy. Stamp duty. sum sum sum sum sum sum sum Unit Qty. Rate Amount (RM)

A200

ENGINEER/SO/PD'S REQUIREMENTS Facilities for the Engineer/SO/PD's representative. Rate shall be deemed to include the provision of water supply, electricity, and communication facilities.

A211

Establishment and removal of [transportable type cabin] office [with a floor area of 70 m2]. Maintenance of office. Establishment and removal of [purpose built] laboratories [with a floor area of 60 m2 as shown in Drawing Nos. (.) to (..)]. Maintenance of laboratories. Equipment for Use by the Engineer/SO/PD's Representative

sum

A212 A213

mth sum

A214

mth

A221

Establishment and removal of office equipment [with type and quantity as per Specification clause (). Equipment to be reverted to the Contractor after completion]. Maintenance of office equipment.

sum

A222

mth

Page Total carried to Summary of Class A

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class A: General Items Page BQA1 of BQA173

CLASS A General Items


Item No. Code No. A223 Description Establishment and removal of laboratory equipment [with type and quantity as per Specification clause (). Equipment to be reverted to the Contractor after completion]. Maintenance of laboratory equipment. Surveying equipment [with type and quantity as per the Specification, Clause (). Equipment to be reverted to the Contractor after completion]. Unit sum Qty. Rate Amount (RM)

A224 A225

mth sum

A226

Maintenance of survey equipment. Services for the Engineer/SO/PD's Representative

mth

A231.1

Provision of transport vehicle [Type A as per Specification clause (..). Vehicle to be reverted to the Contractor after completion]. Provision of transport vehicle [Type B as per Specification clause (..). Vehicle to be reverted to the Contractor after completion]. Maintenance of vehicle [Type A]. Maintenance of vehicle [Type B]. Provision of mobile phones [and to be reverted to the Contractor after completion]. Maintenance of mobile phones. Provision of camera [and to be reverted to the Contractor after completion]. Attendance for Engineer/SO/PD's Representative

sum

A231.2

sum

A232.1 A232.2 A233

mth mth sum

A234 A235

mth sum

A241 A242 A243 A244 A245

[2 Nos.] Drivers for [Type A and Type B vehicle]. [2 Nos.] Survey assistants. [2 Nos.] Laboratory assistants. [4 Nos.] General labours. [2 Nos.] Security guards.

man-mth man-mth man-mth man-mth man-mth

Page Total carried to Summary of Class A

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class A: General Items Page BQA2 of BQA173

CLASS A General Items


Item No. Code No. Description Submission of Documents A251 Project execution plan [as per Specification clause (..)]. Drawings [as per Specification clause (..)]. Method statement [as per Specification clause (..)]. sum Unit Qty. Rate Amount (RM)

A252 A253

sum sum

A254

Work programme [in Microsoft Project on a Gantt Chart format]. Miscellaneous

sum

A261

Progress report [ in five sets]. Rate to include progress photographs. Project signboard. As built drawings. Video recording [as per Specification clause (....)].

mth

A262 A263 A264

nr sum sum

A265

Temporary fencing and hoarding.

sum

A300 A310

PROJECT REQUIREMENTS Survey and setting out [by licensed surveyor]. Quality Assurance/Quality Control (QA/QC) sum

A321 A322

QA/QC Plan [as per Specification clause (..)]. Testing of materials; [concrete test cubes; samples and method of testing as per Specification clause (..)]. Testing of work [for cold water plumbing system as per Specification clause (.)]. Factory acceptance test [for hydrostatic testing of butterfly valves] for three (3) person of the S.O. representatives. Testing and commissioning [of plant for a duration of three (3) months]. Operation and Maintenance of Plant

sum

sum

A323

sum

A324

sum

A325

sum

A331 A332

Operation and Maintenance Manual. Training of operating personnel [for a period of 10 weeks].

sum sum

Page Total carried to Summary of Class A

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class A: General Items Page BQA3 of BQA173

CLASS A General Items


Item No. Code No. A333 Description Provision of manpower [for a period of 12 months]. Unit sum Qty. Rate Amount (RM)

A334

Provision of chemicals and consumable [for a period of 12 months]. Utility cost [for a period of 12 months]. Maintenance of Road

sum

A335

sum

A341

Routine maintenance for existing road as per Specification clause [..]. Periodic maintenanceas for existing road per Specification clause [..]. Routine maintenance for temporary road diversion as per Specification clause [..]. Periodic maintenance for temporary road diversion as per Specification clause [..]. Clearance of site upon completion.

sum

A342

sum

A343

sum

A344

sum

A350

sum

A400

AUTHORITIES' REQUIREMENTS Occupational Safety and Health Requirements

A411 A412

Health and safety plan. Occupational safety and health officer [for duration of the contract period]. Personnel protective equipment as per Specification clause [..]. Health and safety report [in five sets. Rate to include tool box meeting]. Training of health and safety as per Specification clause [..]. Safety signages. Permits and fees [to KTMB for pipe jacking work across railway tracks at (.)]. Deposit [to JKR for pipelaying work along road verge from (..) to ()].

sum man-mth

A413

sum

A414

mth

A415

sum

A416 A420

sum sum

A430

sum

Page Total carried to Summary of Class A

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class A: General Items Page BQA4 of BQA173

CLASS A General Items


Item No. Code No. A500 Description CONTRACTOR'S REQUIREMENTS Facilities Item shall be deemed to include the provision of water supply, electricity, and sanitary facilities and their continuing operation and/or maintenance. Unit Qty. Rate Amount (RM)

A511.1

Set up offices and remove upon completion; fixed charge. Maintain office for duration of contract period; timerelated charge. Provision of office equipment and remove upon completion; fixed charge. Maintain office equipment for duration of contract period; time-related charge. Set up laboratories and remove upon completion; fixed charge. Maintain laboratories for duration of contract period; time-related charge. Provision of laboratories equipment and remove upon completion [with type and quantity as per Specification clause ()]. Maintain laboratories equipment for duration of contract period; time-related charge. Set up stores and remove upon completion; fixed charge.

sum

A511.2

sum

A512.1

sum

A512.2

sum

A513.1

sum

A513.2

sum

A514.1

sum

A514.2

sum

A515.1

sum

A515.2

Maintain store for duration of contract period; timerelated charge. Set up workshops and remove upon completion; fixed charge. Maintain workshop for duration of contract period; timerelated charge. Set up workmen accomodation and remove upon completion; fixed charge. Maintain workmen accomodation for duration of contract period; time-related charge. Provision of transport. Maintain transport for duration of contract period; timerelated charge.

sum

A516.1

sum

A516.2

sum

A517.1

sum

A517.2

sum

A518.1 A518.2

sum sum

Page Total carried to Summary of Class A

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class A: General Items Page BQA5 of BQA173

CLASS A General Items


Item No. Code No. Temporary Work A521.1 Construct temporary access roads to site; fixed charge. sum Description Unit Qty. Rate Amount (RM)

A521.2

Maintain temporary access roads for duration of contract period; time-related charge. Construct temporary bridges and remove upon completion [over Sg. ()]; fixed charge. Maintain temporary bridges for duration of contract period; time-related charge. Construct cofferdams for [water intake] and remove upon completion; fixed charge. Maintain cofferdam for duration of construction; timerelated charge. Install pumping and dewatering at [pumphouse] and remove upon completion; fixed charge. Operation and maintenance of pumping and dewatering for duration of construction; time-related charge.

sum

A522.1

sum

A522.2

sum

A523.1

sum

A523.2

sum

A524.1

sum

A524.2

sum

A525.1

Construct river diversion for [water intake] and reinstate to its original alignment upon completion; fixed charge.

sum

A525.2

Maintain river diversion for duration of construction; time-related charge. Construct temporary jetty [at Sg. ()] and remove upon completion; fixed charge. Maintain temporary jetty for duration of contract period; time-related charge. Construct temporary staging over [Sg. (.)] and remove upon completion; fixed charge. Maintain temporary staging for duration of construction; time-related charge. Site Management

sum

A526.1

sum

A526.2

sum

A527.1

sum

A527.2

sum

A531

Site agent for the duration of conract period; timerelated charge. QA/QC officer for the duration of contract period.

sum

A532

man-mth

Page Total carried to Summary of Class A

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class A: General Items Page BQA6 of BQA173

CLASS A General Items


Item No. Code No. A540 Description Mobilisation and demobilisation. [Rate to include remobilisation for testing and commissioning of the plant after the completion of the pipelaying work under Package (2)]. Unit sum Qty. Rate Amount (RM)

A600 A610 A620 A630 A640 A650

DESIGN AND BUILT ELEMENT Preliminary engineering studies. Design survey. Utilities survey. Site investigation. Design fees. Independent Checkers sum sum sum sum sum

A661 A662 A663 A670

Structural. Geotechnical. Road safety. Supervision fees.

sum sum sum sum

A700

PROVISIONAL/PRIME COST SUMS Provisional Sums

A711.1

Provisional Sum of [RM: Two hundred thousands only for TNB contribution]. Provisional Sum of [RM: Five hundred thousands only for piling work]. Provisional Sum of [RM: Three hundred thousands only for staff quarters to be procured by the Employer].

sum

A711.2

sum

A711.3

sum

A711.4 A711.5

Attendance [for Item A711.3]. Profit for [Item A711.3]. Prime Cost Items

sum %

A721

Prime Cost Sum of [RM: One million only for reinforced soil wall]. Attendance. Profit.

sum

A722 A723

sum %

Page Total carried to Summary of Class A

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class A: General Items Page BQA7 of BQA173

CLASS A General Items


Item No. Code No. Description Summary of Class A: General Items Page BQA1 Page BQA2 Page BQA3 Page BQA4 Page BQA5 Page BQA6 Page BQA7 Unit Qty. Rate Amount (RM)

Total of Class A carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class A: General Items Page BQA8 of BQA173

CLASS B Environmental Protection and Enhancement


Item No. Code No. B100 Description ENVIRONMENTAL MANAGEMENT PLAN (EMP) Preparation of environmental management plan which shall include erosion and sediment control plan (ESCP), flora and fauna management plan by a consultant, registered with the Department of Environment. sum Unit Qty. Rate Amount (RM)

B110

B120

Appointment of environmental officer (EO) for the duration of the contract period.

man-mth

B200

EROSION AND SEDIMENT CONTROL PLAN (ESCP) Items for silt fence, silt curtain, sand bags, gabion wall, and rock check dam shall be deemed to include provisions as per Specification clause (............) and removal of the items upon completion. Silt fence of [1.0 m height] as per Specification clause (..) and as shown in the drawings. Silt curtain as per Specification clause (.) and as shown in the drawings. Sand bag as per Specification clause (.) and as shown in the drawings. Rock-filled gabion wall with PVC coated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in the drawings. Rock check dam as per Specification clause (.) and as shown in the drawings. Sediment Basin m

B210

B220

m2

B230

nr

B240

m3

B250

m3

B261 B262

Excavation. Granular filling. Rate to include imported fill as necessary. Concrete grade [C25]. Rate to include formwork and reinforcement. Class X, 1.0 m diameter reinforced concrete pipe. Geotextile as per Specification clause (.). Rock-filled gabion with PVC-coated wire gauge size of [2.7 mm] as per Specification clause (.).

m3 m3

B263

m3

B264 B265 B266

m m2 m3

Page Total carried to Summary of Class B

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class B: Environmental Protection and Enhancement Page BQB9 of BQB173

CLASS B Environmental Protection and Enhancement


Item No. Code No. B267 Description Rock-filled gabion mattress, 300 mm thick with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.). Riprap of 300 mm average thickness. Silt Trap B271 B272 Excavation. Granular filling. Rate to include imported fill as necessary. Concrete grade [C25]. Rate to include formwork and reinforcement. Class X, 1.0 m diameter reinforced concrete pipe. Geotextile as per Specification clause (.). Rock-filled gabion with PVC-coated wire gauge size of [2.7 mm] as per Specification clause (.). Rock-filled gabion mattress, 300 mm thick with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.). Riprap of 300 mm average thickness. Maintenance Items for maintenance of silt fence, silt curtain, sand bags, gabion wall, rock check dam, sediment basin, and silt trap shall be deemed to include disposal of accumulated debris, sediment and silt to approved site, unless otherwise stated. B281 B282 B283 B284 B285 B286 B287 Silt fence. Silt curtain. Sand bag. Gabion wall. Rock check dam. Sediment basin. Silt trap. sum sum sum sum sum sum sum m3 m3 Unit m2 Qty. Rate Amount (RM)

B268

m2

B273

m3

B274 B275 B276

m m2 m3

B277

m2

B278

m2

Page Total carried to Summary of Class B

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class B: Environmental Protection and Enhancement Page BQB10 of BQB173

CLASS B Environmental Protection and Enhancement


Item No. Code No. B300 Description WATER QUANTITY CONTROL AND MONITORING Skid tank bund [at workshop area in reinforced concrete of size 6 m x 4 m x 1 m high] as per Specification clause () and as shown in the drawing. Rate to include traps, oil and grease separators, and its maintenance and removal upon completion. sum Unit Qty. Rate Amount (RM)

B310

B320

Water treatment facilities for [effluent from tunnel work to comply with Standard (A/B) of the Environmental Quality Act]. Sewage treatment facilities for [workmen accomodation]. Water Quality Sampling and In situ Testing Water quality sampling and monitoring by accredited laboratory on a monthly basis [at the discharge outlet of silt trap/sedimentation basin to comply with the requirements of Standard (A/B) of the Environmental Quality Act for the following parameters].

sum

B330

sum

B341 B342 B345 B347

pH Total suspended solid (TSS). Dissolved Oxygen (DO) Ammoniacal nitrogen Water Quality Sampling and Laboratory Testing Water quality sampling and monitoring by accredited laboratory on a monthly basis [at the effluent discharge point at workmen accommodation, workshop, and canteen to comply with the requirements of Standard (A/B) of the Environmental Quality Act for the following parameters].

nr nr nr nr

B351 B352 B353 B354 B355 B356

pH. Total suspended solid (TSS). Biochemical oxygen demand (BOD). Chemical oxygen demand (COD). Dissolved oxygen (DO). Escherichia coli (E.coli).

nr nr nr nr nr nr

Page Total carried to Summary of Class B

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class B: Environmental Protection and Enhancement Page BQB11 of BQB173

CLASS B Environmental Protection and Enhancement


Item No. Code No. B357 B358 Ammoniacal nitrogen. Oil and grease. Description Unit nr nr Qty. Rate Amount (RM)

B400 B410

AIR QUALITY CONTROL AND MONITORING Tyre washing facilities [in reinforced concrete of size 6 m x 3.6 m as per Specification clause (..) and as shown in the drawing]. Rate to include construction of tyre washing concrete platform, and provision and maintenance of water supply system and portable water jets. Wash trough of [size 6 m x 3.6 m in reinforced concrete, hardcore, and aggregate layers as per Specification clause (..) and as shown in the drawing]. set

B420

nr

B430

Water bowser truck [for carrying out water spraying along haul/access roads and existing roads, and near settlements, for at least three times per day]. Rate to include the provision and maintenance of the vehicle and water supply, and the driver.

nr

B440

Water sprinkler [for control of dust at quarry/batching plant using pumping system]. Rate to include provision and maintenance of water supply.

sum

Air Quality Sampling Air quality sampling by accredited laboratory on a quarterly basis for the following parameters: B451 Total suspended particulates (TSP) over a 24 hours period. Wind velocity and direction. Particulate matter (PM10). nr

B452 B453

nr nr

B500

NOISE AND VIBRATION CONTROL AND MONITORING [Polycarbonate] noise barrier [of 1.5 m height] as per Specification clause (.). Rate to include supply, fabrication, installation, bolts, nuts, posts, and other ancillary work and maintenance. Vibration control. m

B510

B520

sum

Page Total carried to Summary of Class B

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class B: Environmental Protection and Enhancement Page BQB12 of BQB173

CLASS B Environmental Protection and Enhancement


Item No. Code No. Description Noise Level Measurement Noise level measurement and monitoring by accredited laboratory [including L10, L90, and Leq on a quarterly basis near Taman (..)] for the following parameters. Unit Qty. Rate Amount (RM)

B531 B532 B540

Ambient noise level measurement. Spot noise level measurement. Vibration measurement and monitoring by accredited laboratory on a quarterly basis near Taman (..).

nr nr sum

B600 B610

WASTE MANAGEMENT Scheduled wastes as per Specification clause (). Rate to include storage, labelling, and transportation from site by a licensed contractor for disposal as per the Department of Environment (DOE) regulation. sum

B620

Household solid waste as per Specification clause (). Rate to include provision of collection bins, temporary storage area, and disposal to approved site.

sum

B630

Construction solid waste as per Specification clause (). Rate to include provision of collection bins, temporary storage area, and disposal to approved site.

sum

B640

Biomass disposal as per Specification clause (). Rate to include preparation and construction of temporary area, and the disposal to approved site.

sum

B700

CONSERVATION/PRESERVATION Preservation of Flora

B711 B712

Flora survey report [in five sets]. Relocation of flora of the (.) species to the temporary site near the [site office] and finally to the (..) forest reserve. Rate to include the cost of relocation to the temporary and the final site specified. It shall also include excavation, transportation, protection, watering, fertilizing required, and nurturing until the flora are established at the temporary and the final site of relocation.

sum nr

B713

Relocation of flora of the () species to arboreta.

nr

Page Total carried to Summary of Class B

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class B: Environmental Protection and Enhancement Page BQB13 of BQB173

CLASS B Environmental Protection and Enhancement


Item No. Code No. Description Preservation of Fauna B721 B722 Fauna survey report [in five sets]. Relocation of fauna of the () species to the temporary site near the [site office] and finally to the (..) forest reserve. Rate to include the cost of temporary relocation to the rehabilitation centre and final relocation to sites specified. It shall also include trapping, transportation and protection, and treatment required for the well being of the fauna at the rehabilitation centre and before their release at the final site of relocation/rehabilitation. sum nr Unit Qty. Rate Amount (RM)

Preservation of Archeological/Heritage B731 B732 Report [in five sets]. Protection. sum sum

B800 B810.1

ENVIRONMENT REPORT Environmental monitoring report [in five sets on a monthly basis for the TSS content at the discharge outlet of the silt trap/sedimentation basin]. sum

B810.2

Environmental monitoring report [in five sets on a quarterly basis for pH, TSS, BOD, COD, DO, e.coli, ammoniacal nitrogen, and oil and grease, for the discharge point from the project site at Sg. (.)].

sum

B810.3

Environmental monitoring report [in five sets on a quarterly basis for pH, TSS, BOD, COD, DO, e.coli, ammoniacal nitrogen, and oil and grease, for the effluent discharge point at workmen accomodation, workshop and canteen]. Environmental monitoring report [in five sets on a quarterly basis for ambient air quality]. Environmental monitoring report [in five sets on a quarterly basis for noise and vibration measurement].

sum

B810.4

sum

B810.5

sum

B820

Environmental audit report [on a annual basis in five sets]. Environmental closure audit report in [five sets].

sum

B830

sum

Page Total carried to Summary of Class B

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class B: Environmental Protection and Enhancement Page BQB14 of BQB173

CLASS B Environmental Protection and Enhancement


Item No. Code No. Description Summary of Class B: Environmental Protection and Enhancement Page BQB1 Page BQB2 Page BQB3 Page BQB4 Page BQB5 Page BQB6 Unit Qty. Rate Amount (RM)

Total of Class B carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class B: Environmental Protection and Enhancement Page BQB15 of BQB173

CLASS C Traffic Management and Control


Item No. Code No. C100 Description TRAFFIC MANAGEMENT PLAN Traffic management plan shall be deemed to include emergency response plan and the associated work. Unit Qty. Rate Amount (RM)

C110 C120

Traffic Impact Study Preparation of traffic management plan. Rate to include the cost of any survey required, literature, references, consultations, and the production of the document. It shall also include the cost for the engagement of qualified traffic engineers required for carrying out the respective study and the preparation of the said plan.

sum sum

C130 C131 C132 C133 C134

Traffic Management Team Traffic manager. Traffic management officer. Supervisor. Traffic controller. man-mth man-mth man-mth man-mth

C200

TEMPORARY ROAD FURNITURE Items for temporary road furniture shall be deemed to include the supply, installation, maintenance, and removal upon completion. The supply of temporary road furniture shall be deemed to include base preparation, cost of materials, fabrication, and fixing including posts, struts, bolts and nuts, base, storage, and transportation. Installation of temporary road furniture shall be deemed to include cost for multiple shifting within the contractual boundaries and its vicinities that is affected by the traffic management plan.

Temporary road furniture shall be deemed to include cost for the inspection, immediate repair and replacement of any damaged, missing or stolen items throughout the duration of the construction, and removal upon completion.

Page Total carried to Summary of Class C

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class C: Traffic Management and Control Page BQC16 of BQC173

CLASS C Traffic Management and Control


Item No. Code No. Description Temporary Traffic Signs Temporary traffic signs shall be in accordance with JKR Arahan Teknik (Jalan) 2C/85 . C211.1 Portable non-illuminated retro-reflective in [aluminium] sheeting for [advance warning sign]. Portable non-illuminated retro-reflective in [aluminium] sheeting for [detour sign]. Portable non-illuminated retro-reflective in [aluminium] sheeting for [obstruction marker]. Portable non-illuminated retro-reflective in [aluminium] sheeting for [apologetic sign]. Portable changeable message signs (PCMS) of [2.5 m] x [1.5 m] as per Specification clause (). Traffic signals with [3] optical system mounted on [poles] as per Specification clause (.). Rate to include signal post, signal lanterns, traffic controllers, cabling, and removal upon completion. nr Unit Qty. Rate Amount (RM)

C211.2

nr

C211.3

nr

C211.4

nr

C212

nr

C213.1

set

C213.2

Traffic signals with [3] optical system mounted on [gantry]as per Specification clause (.). Rate to include signal lanterns, traffic controllers, cabling, and removal upon completion. Barriers and Barricades

set

C221

Heavy duty water- or sand-filled PVC barrier of the [New Jersey] type. [Precast movable reinforced] concrete barrier of the [New Jersey] type. Wooden barricade. Vehicle mounted impact attenuator. Sand bags. Temporary guardrail. Delineators

nr

C222

nr

C223 C224 C225 C226

nr nr m3 m

C231 C232 C233

[750mm] PVC Traffic cones with reflective bands. [Double sided reflective] string delineators. [750 x 600mm] battery operated flashing arrows on powder coated mild steel plate.

nr m nr

Page Total carried to Summary of Class C

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class C: Traffic Management and Control Page BQC17 of BQC173

CLASS C Traffic Management and Control


Item No. Code No. C234 Description [115mm] diameter battery operated revolving beacon lights. [150mm] diameter polycarbonate lens battery operated blinkers. Temporary Road Markings C241 C241.1 C241.2 C241.3 C242 C243 Letters and shapes. Single straight arrow. Single turning arrow. Double headed arrow. [150mm] wide continuous line. [100mm] wide intermittent line with [1000mm] line and [1700mm] gap. Chevron marking. Transverse bars. Mechanical robot flagman [of the full-man type]. Mechanical robot flagman [of the full-man type]. Temporary street lightings. nr nr nr nr m m Unit nr Qty. Rate Amount (RM)

C235

nr

C244 C245 C250.1 C250.2 C260

m2 m2 nr nr nr

C300 C310

TRAFFIC MANAGEMENT REPORT Traffic management safety report [on a monthly basis in five sets]. Road safety audit report [on a quarterly basis in five sets]. Rate to include the cost of any survey required, literatures, references, consultations, and the production of the document. It shall also include the cost for the engagement of the road safety auditor required for carrying out the audit and the preparation of the said audit report. sum

C320

sum

Page Total carried to Summary of Class C Class C: Traffic Management and Control Page BQC18 of BQC173

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

CLASS C Traffic Management and Control


Item No. Code No. Description Summary of Class C: Traffic Management and Control Page BQC1 Page BQC2 Page BQC3 Unit Qty. Rate Amount (RM)

Total of Class C carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class C: Traffic Management and Control Page BQC19 of BQC173

CLASS D Site Investigation Work


Item No. Code No. D100 Description MOBILISATION AND DEMOBILISATION Rate shall be deemed to include provision of all plant and equipment, transportation to the Site, including transfer between different locations within the Site, handling, assembling amd removal off the Site after completion of operation. Unit Qty. Rate Amount (RM)

D110 D120 D130

Deep Boring Cone Penetration Tests Field Tests

sum sum sum

D200

DEEP BORING Rate to include ground water observation as per Specification clause (...). Plant Movement Shifting of plant and equipment from one borehole position to the next borehole position, rate to include dismantling from one position and erecting at another position where the borehole is to be carried out on:

D211 D212 D213 D214 D215

Flat land. Hillslopes. Floating platform. Fixed platform. Swampy ground. Boring in Soil Carrying out vertical boring in soil using [rotary wash boring equipment (NW size)] for depth measured from Commencing Surface. Rate to include provision of casing where necessary. Water [as drilling fluid]

nr nr nr nr nr

D221.1 D221.2 D221.3 D221.4

Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m.

m m m m

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD20 of BQD173

CLASS D Site Investigation Work


Item No. Code No. D221.5 D221.6 40 50 m. Exceeding 50 m. Water with bentonite or polymer [as drilling fluid] Description Unit m m Qty. Rate Amount (RM)

D222.1 D222.2 D222.3 D222.4 D222.5 D222.6

Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Air/foam [as drilling medium]

m m m m m m

D223.1 D223.2 D223.3 D223.4 D223.5 D223.6

Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Drilling in Rock Carry out vertical diamond core drilling of [52 mm] diameter into rock including storing of core samples in standard boxes. [Core boxes shall become property of the Employer]. Water [as drilling fluid]

m m m m m m

D231.1 D231.2 D231.3 D231.4 D231.5 D231.6

Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Air/foam [as drilling medium]

m m m m m m

D232.1

Not exceeding 10 m. Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD21 of BQD173

CLASS D Site Investigation Work


Item No. Code No. D232.2 D232.3 D232.4 D232.5 D232.6 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Reaming casing D233.1 D233.2 D233.3 D233.4 D233.5 D233.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Grouting D234.1 D234.2 D234.3 D234.4 D234.5 D234.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Test Standard penetration test D241.1 D241.2 D241.3 D241.4 D241.5 D241.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. nr nr nr nr nr nr m m m m m m m m m m m m Description Unit m m m m m Qty. Rate Amount (RM)

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD22 of BQD173

CLASS D Site Investigation Work


Item No. Code No. Vane shear test D242.1 D242.2 D242.3 D242.4 D242.5 D242.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Pressure meter test D243.1 D243.2 D243.3 D243.4 D243.5 D243.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Field permeability test D244.1 D244.2 D244.3 D244.4 D244.5 D244.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Dynamic cone test D245.1 D245.2 D245.3 D245.4 D245.5 D245.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr Description Unit Qty. Rate Amount (RM)

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD23 of BQD173

CLASS D Site Investigation Work


Item No. Code No. Sampling Carry out the following sampling in borehole. Rate to include transportation and protection as per Specification clause (). [5 kg] Disturbed samples D251.1 D251.2 D251.3 D251.4 D251.5 D251.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Undisturbed sample using thin wall tube sampler D252.1 D252.1 D252.3 D252.4 D252.5 D252.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Undisturbed sample using Mazier sampler D253.1 D253.2 D253.3 D253.4 D253.5 D253.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Undisturbed sample using piston sampler D254.1 D254.2 D254.3 Not exceeding 10 m. 10 20 m. 20 30 m. Page Total carried to Summary of Class D nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr nr Description Unit Qty. Rate Amount (RM)

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD24 of BQD173

CLASS D Site Investigation Work


Item No. Code No. D254.4 D254.5 D254.6 30 40 m. 40 50 m. Exceeding 50 m. Undisturbed sample using Denison sampler D255.1 D255.2 D255.3 D255.4 D255.5 D255.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Water sample [minimum 1 litre] D256.1 D256.2 D256.3 D256.4 D256.5 D256.6 Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Miscellaneous D261 Borehole marker. nr nr nr nr nr nr nr nr nr nr nr nr nr Description Unit nr nr nr Qty. Rate Amount (RM)

D300

CONE PENETRATION TESTS Plant movement Shifting of plant and equipment from one test position to the next test position, rate to include dismantling from one position and erecting at another position where the test is to be carried out on:

D311 D312 D313 D314 D315

Flat land. Hillslopes. Floating platform. Fixed platform. Swampy ground. Page Total carried to Summary of Class D

nr nr nr nr nr

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD25 of BQD173

CLASS D Site Investigation Work


Item No. Code No. Test Dutch cone penetration test [using cone type () and (.) kg ram as per Specification clause (.)] Description Unit Qty. Rate Amount (RM)

D321.1 D321.2 D321.3 D321.4 D321.5 D321.6

Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Piezocone

m m m m m m

D322.1 D322.2 D322.3 D322.4 D322.5 D322.6

Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Dissipation test [maximum 2 hours per test]

m m m m m m

D323.1 D323.2 D323.3 D323.4 D323.5 D323.6

Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Miscellaneous

nr nr nr nr nr nr

D331

Test location marker.

nr

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD26 of BQD173

CLASS D Site Investigation Work


Item No. Code No. D400 FIELD TESTS Rate for field tests shall be deemed to include plant movements on site and logging of daily field records. Description Unit Qty. Rate Amount (RM)

Hand Auger Rate for augering in soil shall be deemed to include ground water observation as per Specification clause (). D411 D412 D413 Augering in soil. Disturbed sample [min. 1 kg]. Undisturbed samples using thin wall tube sampler. m nr nr

D414

Water sample [min. 3 litres]. Trial Pit Pit size [2 m wide x 2 m long x 2 m deep]. Rate shall be deemed to include lateral support, logging and mapping of side wall and backfilling, and ground water observation as per Specification clause (). Rate for sampling shall be deemed to include transportation and protection as per Specification clause (..).

nr

D421 D422 D423 D424 D425

Excavation. Small disturbed sample [1 kg]. Bulk sample [min. 50 kg]. Block sample [300 mm x 300 mm]. Water sample [min. 3 litres]. Testing

nr nr nr nr nr

D431 D432 D433

Mackintosh or JKR probes. Vane shear. Plate bearing [300 mm square plate, test pressure 250 kPa with range from uploading and downloading cycle].

m nr nr

D434 D435

In situ CBR at locations as shown in drawings. Pocket penetrometer.

nr nr

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD27 of BQD173

CLASS D Site Investigation Work


Item No. Code No. D436 Description Field density as per Specification clause (..). Unit nr Qty. Rate Amount (RM)

Sampling Carry out the following sampling at location as indicated in the drawing. Rate for sampling shall be deemed to include transportation and protection as per Specification clause (..).

D441 D442 D443

Small disturbed sample [1 kg]. Bulk sample [min. 50 kg]. Undisturbed samples using thin wall tube sampler.

nr nr nr

D444 D445

Block sample [300 mm x 300 mm]. Water sample [3 litres].

nr nr

D500

LABORATORY TESTS All laboratory tests shall be to [BS 1377:1990], unless stated otherwise. Rate to include preparation of specimens. Classification Test

D511 D512 D513 D514 D515

Mositure content. Atterberg limits. Specific gravity. Particle size distribution for fine-grained soils. Particle size distribution for coarse-grained soils. Soil Strength Tests Each set shall consist of 3 nos. of [50 mm diameter x 100 mm length undisturbed] specimen.

nr set nr nr nr

D521 D522 D523

Unconfined compressive strength. Unconsolidated undrained triaxial compression. Consolidated undrained triaxial compression test with pore water pressure measurement. Consolidated drained triaxial compression test with pore water pressure measurement. [60 mm square] direct shear box test.

nr set set

D524

set

D525.1

set

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD28 of BQD173

CLASS D Site Investigation Work


Item No. Code No. D525.2 D525.3 D526.1 D526.2 Description [100 mm square] direct shear box test. [300 mm square] direct shear box test. [60 mm square] multi-reversal shear box test. [100 mm square] multi-reversal shear box test. Soil Compaction Related Tests Each set shall consist of 5 nos. of specimen. D531 D532 D533 D534 D535 Standard compaction (2.5 kg hammer). Heavy compaction (4.5 kg hammer). Vibrating hammer. Unsoaked CBR [on both ends]. Soaked CBR [on both ends]. Chemical and Electro-chemical Tests D541 D542 D543 D544 D545 D546 D547 D548 Organic matter content. Loss on ignition. Total sulphate content. Sulphate content. Chloride content. pH value. Resistivity test. Contaminants [...] as per [ BS standard]. Rock Strength Tests D551 D552 Unconfined compressive strength. Unconfined compressive strength with Young's modulus and Poisson's ratio measurement. Point load test. Petrographic examination as per Specification clause (.). Compressibility and Permeability Tests D561 One-dimensional consolidation. nr nr nr nr nr nr nr nr nr nr nr set set set nr nr Unit set set set set Qty. Rate Amount (RM)

D553 D554

nr nr

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD29 of BQD173

CLASS D Site Investigation Work


Item No. Code No. D562 D563 Description Variable head permeability. Fixed head permeability. Unit nr nr Qty. Rate Amount (RM)

D600 D610

INSTRUMENTATION Piezometer as per Specification clause (..) and as shown in the drawings. Rate to include pre-boring and installation. Inclinometer as per Specification clause (..) and as shown in the drawings. Rate to include pre-boring and installation. Settlement surface marker. Settlement plate as per Specification clause (..) and as shown in the drawings. Settlement displacement marker. Magnetic extensometer as per Specification clause (.). Deep levelling datum. Monitoring of instrument for the above instrument at the project site by [Geologist] as per Specification clause (..). Rate to include preparation of monitoring report to be submitted on a [monthly ] basis. nr

D620

nr

D631 D632

nr nr

D633 D640

nr nr

D650 D660

nr nr

D700

GEOPHYSICAL SURVEY AND MAPPING Seismic Refraction Survey

D711

Setting out sets of seismic lines, rentising and produce geophone, reduce levels, and topographical profile of each seismic line using EDM.

sum

D712

Carry out seismic refraction survey with a 24-channel seismograph with geophones at intervals of not more than 5 m measured along the slope, and 7 shots per set, using sledge hammer as the seismic energy source. Rate to include data analysis to produce geological profile incorporating borehole data where available.

set

D713

Prepare maps of soil isopach and bedrock contour of the Site as per Specification clause (), based on rock levels obtained from seismic refraction survey.

sum

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD30 of BQD173

CLASS D Site Investigation Work


Item No. Code No. Resistivity Profiling D721 Setting out sets of resistivity profiling, rentising and produce electrodes reduce levels and topographical profile of each resistivity profile line including topographical coordinates of each electrode. sum Description Unit Qty. Rate Amount (RM)

D722

Carry out [2D] resistivity profiling using [SchlumbergerWenner configuration and roll-along technique with 40 electrodes at 5-meter intervals], each interval measured as the slope distance between adjacent electrodes.

set

D723 D730

Process data for preparation of resistivity profiles. Geological terrain mapping as per Specification clause (.) and in accordance to guidelines by the Minerals and Geoscience Department, Malaysia, covering area as shown in the drawings.

sum m2

Utilities Detection and Mapping D741 Locate, detect, and map all utilities and services as per Specification clause (...), for area as shown in drawings. Verification with utilities provider. Rate to include purchase of necessary documents and verification on the utilities detected as compared with the records of the utilities provider. Conduct site verification. m2

D742

sum

D743

sum

D800

REPORT Preliminary Report

D811

Soil investigation report including laboratory test results as per Specification clause () to be submitted in [two sets] with comb binding.

sum

D812

Seismic refraction survey report as per Specification clause () to be submitted in [two sets] with comb binding. Rate to include geological sections and interpretation of data by specialists.

sum

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD31 of BQD173

CLASS D Site Investigation Work


Item No. Code No. D813 Description Resistivity profiling report as per Specification clause () to be submitted in [two sets] with comb binding. Rate to include geological sections and interpretation of data by specialists. Unit sum Qty. Rate Amount (RM)

D814

Geological terrain mapping report as per Specification clause () to be submitted in [two sets] with comb binding. Utilities detection and mapping report as per Specification clause ( ) to be submitted in [two sets] with comb binding. Final Report

sum

D815

sum

D821

Soil investigation report including laboratory test results as per Specification clause () to be submitted in [five sets] in hard cover.

sum

D822

Seismic refraction survey report as per Specification clause () to be submitted in [five sets] in hard cover. Resistivity profiling report as per Specification clause () to be submitted in [five sets] in hard cover.

sum

D823

sum

D824

Geological terrain mapping report as per Specification clause () to be submitted in [five sets] in hard cover. Utilities detection and mapping report as per Specification clause () to be submitted in [five sets] in hard cover.

sum

D825

sum

Page Total carried to Summary of Class D

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD32 of BQD173

CLASS D Site Investigation Work


Item No. Code No. Description Summary of Class D: Site Investigation Work Page BQD1 Page BQD2 Page BQD3 Page BQD4 Page BQD5 Page BQD6 Page BQD7 Page BQD8 Page BQD9 Page BQD10 Page BQD11 Page BQD12 Page BQD13 Unit Qty. Rate Amount (RM)

Total of Class D carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class D: Site Investigation Work Page BQD33 of BQD173

CLASS E Demolition and Site Clearance


Item No. Code No. Description Unit Qty. Rate Amount (RM)

Items for demolition and site clearance shall be deemed to include disposal of the materials arising. E100 GENERAL CLEARANCE Above Ground E110.1 General clearance to [primary forest]. Rate to include the removal of trees and stumps, undergrowth, shrubs, roots, and the likes. [All trees of 0.5 m girth and above shall become the property of the Employer]. ha

E110.2 E120

General clearance to [palm oil estate]. At water bodies. Rate to include removal and disposal of items as per Specification clause (..) in or at [Lake Project] including objects either floating, submerged or at the bed of the the [lake].

ha ha

E200

TREES Felling of trees shall be deemed to include uprooting and removal of stumps. [All trees of 0.5 m girth and above shall become the property of the Employer].

E210 E220 E230 E240

Trees of girth: 0.5 1 m. Trees of girth: 1 2 m. Trees of girth: 2 5 m. Trees of girth exceeding 5 m. [Holes after the removal of stumps shall be filled with granular material].

nr nr nr nr

E300

BUILDING Concrete

E311

Individual building [2-storey bungalow with reinforced concrete walls of total gross built-up area of 2000 m2]. Group of buildings [10 units of single storey chalet with a gross built-up area of 100 m2 each].

sum

E312

sum

Page Total carried to Summary of Class E

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class E: Demolition and Site Clearance Page BQE34 of BQE173

CLASS E Demolition and Site Clearance


Item No. Code No. Description Brickwork and Masonry E321 Individual building [single storey bungalow of total gross builtup area of 200 m2]. Group of buildings [10 units of single storey chalet with a gross builtup area of 100 m2 each]. Timber E331 E332 Individual building [3 m x 3 m guard house]. Group of buildings [10 units of single storey chalet with a gross builtup area of 100 m2 each]. sum sum sum Unit Qty. Rate Amount (RM)

E322

sum

Metal E341 Individual buildings [50 m x 10 m steel portal frame factory]. Group of buildings [2 units of 10 m x 6 m steel stores]. sum

E342

sum

No predominant material E351 Individual buildings [single storey reinfoced concrete frame with brick infill and steel roof structure house of total gross builtup area of 300 m2]. sum

E352

Group of buildings [single storey reinfoced concrete frame with brick infill and steel roof structure chalet of gross builtup area of 100 m2 each].

sum

E400

STRUCTURES Concrete

E411

Above ground [10 m long x 6 m wide x 6 m deep mixing chamber]. Below ground [Precast concrete box culverts including headwall, wingwall and foundation 20 m long x 3 m wide x 2 m deep]. Brickwork and Masonry

sum

E412

sum

E421 E422

Above ground [2 m x 2 m x 3 m high manhole]. Below ground [2 m x 2 m x 3 m deep manhole]. Timber

sum sum

E431

Above ground 3 m x 3 m timber shed.

sum

Page Total carried to Summary of Class E

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class E: Demolition and Site Clearance Page BQE35 of BQE173

CLASS E Demolition and Site Clearance


Item No. Code No. Metal E441 Above ground [2 m x 2 m x 20 m high truss support to cooling tower]. No Predominant Material E451 Above ground [10 m long x 6 m wide x 3 m high water tank with timber roof]. Below ground [10 m x 6 m wide x 5 m deep tank with steel bracing]. sum sum Description Unit Qty. Rate Amount (RM)

E452

sum

E500

PIPELINES Demolition of pipelines shall be deemed to include demolition and removal of supports. [Dismantle 400 mm DN elevated mild steel pipeline]. The pipeline shall become the property of the Employer and shall be delivered to the store at (.). m

E510

Page Total carried to Summary of Class E

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class E: Demolition and Site Clearance Page BQE36 of BQE173

CLASS E Demolition and Site Clearance


Item No. Code No. Description Summary of Class E: Demolition and Site Clearance Unit Qty. Rate Amount (RM)

Page BQE1 Page BQE2 Page BQE3

Total of Class E carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class E: Demolition and Site Clearance Page BQE37 of BQE173

CLASS F Earthworks
Item No. Code No. F100 EXCAVATION Stripping F111.1 Topsoil of average depth of 150 mm and disposed to the Contractor's dumpsite as approved by the Engineer/S.O./P.D. Topsoil of average depth of 150 mm and stockpile for reuse as top soil for turfing. Cut to Fill Excavation in cut shall be deemed to include trimming and preparation of excavated surface and transportation from source to place of fill or disposal. m2 Description Unit Qty. Rate Amount (RM)

F111.2

m2

F121.1

Excavate in earth material from original ground level [to form embankment]. Excavate in earth material commencing from [104 m] [to form embankment]. Excavate manually in earth material commencing from [104 m] to [103.5 m]. Excavate in natural hard material to form embankment.

m3

F121.2

m3

F121.3

m3

F122

m3

F123.1

Excavate in rock material by open blasting [to form embankment]. Excavate in rock material by controlled blasting [to form embankment]. Excavate in rock material by hydraulic rock breaker [to form embankment]. Excavate in rock material by pneumatic tools [to form embankment]. Cut and Dispose Excavation in cut shall be deemed to include trimming and preparation of excavated surface and transportation from source to place of fill or disposal.

m3

F123.2

m3

F123.3

m3

F123.4

m3

F131.1

Excavate in earth material commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D.

m3

Page Total carried to Summary of Class F

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class F: Earthworks Page BQF38 of BQF173

CLASS F Earthworks
Item No. Code No. F131.2 Description Excavate in earth material commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D. [Rate to include compaction at disposal site]. Excavate in natural hard material by ripper unit commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D. Excavate in rock by controlled blasting commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D. Excavate in rock by open blasting commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D. Excavate in artificial hard material by hydraulic rock breaker to disposal site approved by the Engineer/S.O./P.D. Excavate in unsuitable material commencing from [104 m] to [103 m] to disposal site approved by the Engineer/S.O./P.D. Foundation Excavation for foundation shall include upholding sides of excavation, preparation of excavated surface, additional excavation to provide working space and removal of dead services. Unit m3 Qty. Rate Amount (RM)

F132

m3

F133.1

m3

F133.2

m3

F134

m3

F135

m3

F141

Excavate in earth material commencing from level [104 m] to [102 m] to [clear water tank]. Excavate in natural hard material using ripper unit commencing from level [104 m] to [102 m] to [raft foundation for chemical building]. Excavate in rock using [hydraulic rock breaker] commencing from level [104 m] to [101 m] to [raft foundation for treated water pumping station]. Excavate in artificial hard material at [TNB sub-station].

m3

F142

m3

F143

m3

F144

m3

F145

Excavate in unsuitable material commencing from level [102 m] to [101 m] at [clear water tank]. Excavate under water at Sg. () from river bed level of [54 m] to [52 m]. Rate shall include all necessary temporary work.

m3

F150

m3

Page Total carried to Summary of Class F

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class F: Earthworks Page BQF39 of BQF173

CLASS F Earthworks
Item No. Code No. F161 Description Provision of plant and equipment for dredging work at Sg. (.). Rate to include mobilisation and demobilisation. Excavation by dredging at Sg. (..) to limits as shown in Drawing No. (). Rate shall include transportation from source to place of disposal and mopping up of silt which accumulates after the Final Surface has been reached. Unit sum Qty. Rate Amount (RM)

F162

m3

F200

EXCAVATION ANCILLARIES Double Handling of Excavated Material

F211

In earth material to temporary stockpile approved by the Engineer/S.O./P.D. In natural hard material to temporary stockpile approved by the Engineer/S.O./P.D. In rock to temporary stockpile approved by the Engineer/S.O./P.D. In artificial hard material to temporary stockpile before final disposal. Timber support left-in. Metal support left-in.

m3

F212

m3

F213

m3

F214

m3

F230 F240

m2 m2

F300

FILLING The following items for filling shall include compaction, and additional filling necessitated by settlement or penetration into underlying material as applicable.

General F311 Using suitable excavated material to grading limits as per Specification clause (). Imported material from Contactor's own source with grading limits as per Specification clause (..). m3

F312.1

m3

F312.2

Imported material from borrow pit as shown in the drawing with grading limits as per Specification clause (..). Grade C20 mass concrete.

m3

F313

m3

Page Total carried to Summary of Class F

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class F: Earthworks Page BQF40 of BQF173

CLASS F Earthworks
Item No. Code No. F314 Description Other stated material granular material as per Specification clause (..). Embankments F321 Using suitable excavated material to grading limits as per Specification clause () to form embankment. Rate to include formation of benches. m3 Unit m3 Qty. Rate Amount (RM)

F322

Imported material from Contactor's own source with grading limits as per Specification clause (..) to form embankment. Rate to include formation of benches.

m3

F323 F324

Grade C20 mass concrete. Other stated material granular material as per Specification clause (..) to form drainage layer to embankment. Replacement

m3 m3

F331

Replace unsuitable material using excavated material.

m3

F332

Replace unsuitable material using imported material from Contactor's own source. Replace excavated unsuitable material with Grade C20 mass concrete. Other stated material granular material as per Specification clause (..) to replace unsuitable material.

m3

F333

m3

F334

m3

F340.1 F340.2

To structures filling around column stumps. To structures filling sides of wall above raft foundation. Filling to embankment at Sg. (.) below water level.

m3 m3

F350

m3

F400 F410

FILLING ANCILLARIES [Continuous polypropylene filament, nonwoven] geotextile with tensile strength of 19 kN/m, effective opening size of 0.09mm and nominal mass of 250 g/m2 as per Specification clause (.). m2

Page Total carried to Summary of Class F

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class F: Earthworks Page BQF41 of BQF173

CLASS F Earthworks
Item No. Code No. F500 LANDSCAPING Items for landscaping shall be deemed to include digging, planting media, bedding, stalking, protection, watering, weeding, required fertilising, and replacement of dead item until the vegetation is established. Description Unit Qty. Rate Amount (RM)

F510.1 F510.2

Spot turfing to flat areas. Close turfing to slopes. Rate to include pegging down with stakes. Hydroseeding as per Specification clause (.). Hydroseeding with fibromat or equivalent. Bio-degradable erosion control blanket to slope of embankment with fastening hook at [mm] spacing. Rate to include fastening hook and netting.

m2 m2

F520.1 F520.2 F530

m2 m2 m2

F540

Vertiver grass or equivalent at 250 mm spacing (in group of 3 rows). Trees of the (.) species with minimum girth of [200 mm] and [3 m] tall.

F550

nr

Page Total carried to Summary of Class F

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class F: Earthworks Page BQF42 of BQF173

CLASS F Earthworks
Item No. Code No. Description Summary of Class F: Earthworks Page BQF1 Page BQF2 Page BQF3 Page BQF4 Page BQF5 Unit Qty. Rate Amount (RM)

Total of Class F carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class F: Earthworks Page BQF43 of BQF173

CLASS G Geotechnical Work


Item No. Code No. G100 G110 Description PLANT AND EQUIPMENT Provision of all necessary plant and equipment, transportation to the Site, handling, assembling, and removal off the Site after completion of operation. sum Unit Qty. Rate Amount (RM)

G120

Moving and handling all necessary plant and equipment within the Site and from location to location as often as is and whenever necessary for the execution of whole operation. Temporary staging.

sum

G130

sum

G200

RETAINING STRUCTURES Gabion

G211.1

[1.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in the drawings.

m3

G211.2

[2.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in the drawings.

m3

G211.3

[1.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in the drawings. Rate to include for laying underwater. Rock-filled gabion mattress, [300 mm] thick with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in Drawing No. (....).

m3

G212

m2

G213

Non-woven geotextile as separator as per Specification clause (.). Cribwall Item for cribwall shall be deemed to include precast reinforced concrete (Grade 30) components and granular infill material as per Specification clause (.).

m2

G221

Single cell with [1200 mm] header as shown in Drawing No. (.). Double cell with [1200 mm + 1200 mm] header as shown in Drawing No. (..).

m2

G222

m2

Page Total carried to Summary of Class G

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class G: Geotechnical Work Page BQG44 of BQG173

CLASS G Geotechnical Work


Item No. Code No. G223 Description Triple cell with [1650 mm + 1650 mm + 1200 mm] header as shown in Drawing No. (.). Quadruple cell with [1200 mm + 1200 mm + 1200 mm + 1200 mm] as shown in Drawing No. (..). Unit m2 Qty. Rate Amount (RM)

G224

m2

G225

Non-woven geotextile as separator as per Specification clause (.). Reinforced Soil Slope

m2

G231

Woven geotextile with minimum long term design strength of [100 kN/m] as soil reinforcement as per Specification clause (.). Geogrid with minimum long term design strength of [75 kN/m] as soil reinforcement as per Specification clause (.). Reinforced earth filling as per Specification clause (.) and as shown in Drawing No. (.). Reinforced granular filling as per Specification clause (.) and as shown in Drawing No. (.). [HDPE] erosion protection mats with minimum tensile strength of [1.4 kN/m] as per Specification clause (.).

m2

G232

m2

G233

m3

G234

m3

G235

m2

Reinforced Soil Wall [Precast reinforced concrete wall facing panels], rate to include galvanised steel soil reinforcement, connections and jointing, geotextile, and accessories for wall joints for wall height:

G241.1 G241.2 G241.3 G241.4 G242

Not exceeding 6 m. Exceeding 6 m but not exceeding 9 m. Exceeding 9 m but not exceeding 12 m. Exceeding 12 m but not exceeding 15 m. Reinforced earth filling as per Specification clause (.).

m2 m2 m2 m2 m3

G243

Reinforced granular filling as per Specification clause (.). [350 mm wide x 150 mm thick G20 mass concrete] leveling pad.

m3

G244

Page Total carried to Summary of Class G

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class G: Geotechnical Work Page BQG45 of BQG173

CLASS G Geotechnical Work


Item No. Code No. G245 Description Pull out test, rate to include all necessary equipment and submission of procedure, records, and report. Unit nr Qty. Rate Amount (RM)

G300

SLOPE STABILISATION Soil Nailing Rate for soil nailing shall be deemed to include drilling of borehole, corrugated HDPE pipe if applicable, sleeve grouting, sealant compound, galvanised steel bearing plate, and all necessary formwork.

[100 mm dia.] soil nail with [T25] reinforcement bar as shown in Drawing No. (....). G311.1 G311.2 G311.3 [6 m] long. [9 m] long. [12 m] long. Pull out test on soil nail, rate to include all necessary equipment and submission of procedure, records, and report. G312.1 G312.2 G312.2 To [1.5] times the working load of 50 kN. To [1.5] times the working load of 75 kN. To [1.5] times the working load of 100 kN. Rock Bolt Rate for rock bolt shall be deemed to include drilling of borehole, reinforcement bar, reinforced concrete pad, sleeve grouting, sealant compound, and all necessary formwork. Type A with T32 bolt as shown in Drawing No. (.). nr nr nr nr nr nr

G321.1 G321.2 G322

[2 m] long. [4 m] long. Pull out test on rock bolt as specified, rate to include all necessary equipment and submission of procedure, records, and report.

nr nr nr

Page Total carried to Summary of Class G

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class G: Geotechnical Work Page BQG46 of BQG173

CLASS G Geotechnical Work


Item No. Code No. Ground Anchor Rate for ground anchor shall be deemed to include prestressed tendons, drilling, grouting, concreting, and all necessary formwork. [Type 1] ground anchor as shown in Drawing No. (.). Description Unit Qty. Rate Amount (RM)

G331 G332 G333 G334

In earth. In natural hard material. In rock. Pull out test on ground anchor as per Specification clause (.), rate to include all necessary equipment and submission of procedure, records, and report.

m m m nr

Concrete Buttress Rate for concrete buttress shall be deemed to included steel fabric mesh, PVC drain pipe, dowel bars, filter material, and all necessary formworks.

G340.1

[G25] concrete buttress with average thickness [not exceeding 300 mm]. [G25] concrete buttress with average thickness [exceeding 300 mm but not exceeding 400 mm]. Horizontal Drain Rate for horizontal drain shall be deemed to include drilling and perforated pipe. [100 mm] diameter uPVC horizontal drain as shown in Drawing No. (.).

m2

G340.2

m2

G351 G352

In earth. In rock.

m m

G400 G410

SURFACE PROTECTION [100 mm] thick [G25] guniting. Rate shall be deemed to include steel fabric mesh, PVC drain pipe, dowel bar, and filter material as shown in Drawing No. (.). m2

Page Total carried to Summary of Class G

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class G: Geotechnical Work Page BQG47 of BQG173

CLASS G Geotechnical Work


Item No. Code No. G420 Description [150 mm thick] concrete articulating slab as per Specification clause (.) and as shown in Drawing No. (....). Rate to include prepartion of surface, blinding, aggregate, geotextile, and all necessary concrete and formwork. Rock netting with PVC-coated wire gauge size of [2.7 mm] as per Specification clause (.). Rate to include all necessary accessories. [250 mm] thick stone pitching as per Specification clause (.). [250 mm] thick stone revetment as per Specification clause (.). Unit m2 Qty. Rate Amount (RM)

G430

m2

G440

m2

G450

m2

G500 G510

GROUND TREATMENT [100 mm x 3 mm] prefabricated vertical drains as per Specification clause (). Dynamic compaction using [10 tonne] drop hammer with [five] drops at height of 15 m. Vibro compaction up to depth of [10 m] as per Drawing No (.) 1000 mm diameter sand column as per Specification clause (.). 1000 mm diameter aggregate column as per Specification (.). 1000 mm diameter stone column as per Specification (.). 1000 mm diameter cement column as per Specification (.). m

G520

nr

G530

nr

G540

G550

G560

G570

G600

GROUTING WORK Drilling for [50 mm] diameter grout holes for depth not exceeding [10 m] in:

G611 G612

Earth. Rock; rate to include drilling in natural and artificial hard material. uPVC sleeve pipes for [50 mm] diameter grout hole. Rate to include grouting of annulus space between the sleeve pipe and the drill holes.

m m

G620

Page Total carried to Summary of Class G

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class G: Geotechnical Work Page BQG48 of BQG173

CLASS G Geotechnical Work


Item No. Code No. Grout Injection Grout mixed components: G631 G632 G633 G634 Cement. Sand. Bentonite. Aluminium powder. Connection for grouting for the following. Rate to include provision of packer as expressly required. t t t kg Description Unit Qty. Rate Amount (RM)

G640.1 G640.2 G650

Ascending stage with single packer setting. Descending stage with double packer setting. Water pressure test as per Specification clause (.).

nr nr nr

G700

DIAPHGRAGM WALLS Excavation Excavation for [1.2 m] thick diaphragm wall not exceeding depth 15 m for the following. Rate to include preparation and upholding sides of excavation.

G711 G712 G713 G714 G720

Earth. Natural hard material. Rock. Artificial hard material. [Grade C40] tremie mix concrete. Reinforcement, Rate To Include Labour for Cutting, Bending and Placing Mild steel bar reinforcement

m3 m3 m3 m3 m3

G731.1 G731.2

Nominal diameter: [10 mm]. Nominal diameter: [12 mm]. High tensile steel bar reinforcement

t t

G732.1 G732.2

Nominal diameter: [12 mm]. Nominal diameter: [16 mm].

t t

Page Total carried to Summary of Class G

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class G: Geotechnical Work Page BQG49 of BQG173

CLASS G Geotechnical Work


Item No. Code No. G732.3 G732.4 G732.5 G740 G750 G760 Description Nominal diameter: [20 mm]. Nominal diameter: [25 mm]. Nominal diameter: [32 mm]. Waterproofed joints. Guide walls. Preparing top of walls to receive cappings as per Specification clause (.). Preparing cast in pockets or chases as shown in Drawing No. (....). Unit t t t sum m m Qty. Rate Amount (RM)

G770

Page Total carried to Summary of Class G

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class G: Geotechnical Work Page BQG50 of BQG173

CLASS G Geotechnical Work


Item No. Code No. Description Summary of Class G: Geotechnical Work Page BQG1 Page BQG2 Page BQG3 Page BQG4 Page BQG5 Page BQG6 Page BQG7 Unit Qty. Rate Amount (RM)

Total of Class G carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class G: Geotechnical Work Page BQG51 of BQG173

CLASS H Piling Work


Item No. Code No. H100 H110 Description PLANT AND EQUIPMENT Provision of all necessary piling plant and equipment, transportation to the Site, handling, assembling, and removal off the Site after completion of operation. sum Unit Qty. Rate Amount (RM)

H120

Moving and handling of all piling plant and equipment within the Site and from location to location as often as is, and whenever necessary for the execution of the whole piling operation. Temporary staging [for piling work at the banks of Sg. (..)].

sum

H130

sum

H200

PILES Items for piling work shall be deemed to include piling records and disposal of excavated and surplus materials.

Bored Piles Items for bored piles shall be deemed to include temporary casings, stabilising agent, and enlarged bases.

[900 mm] diameter bored piles as working piles. H211.1 Boring in earth, up to [20 m] for [50] nos. of pile points. m

H211.2

Boring in earth, raked at inclination of ratio [1:5] for [10] nos. of pile points. Boring through rock, up to [10 m] for [50] nos. of pile points. Rate to include natural and artificial hard material. Boring through rock and raked at inclination ratio of [1:6] for [10] nos. of pile points. Rate to include natural and artificial hard material. [12 mm] thick mild steel permanent casings. Rate to include the supply and jointing of casings, driving heads, and shoes. High tensile reinforcement straight bars, nominal diameter not exceeding 20 mm. Rate to include supporting reinforcement.

H212.1

H212.2

H213

H214

Page Total carried to Summary of Class H

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class H: Piling Work Page BQH52 of BQH173

CLASS H Piling Work


Item No. Code No. H215 Description High tensile reinforcement straight bars, nominal diameter exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement helical bars, nominal diameter exceeding 20 mm.. Rate to include supporting reinforcement. Concreted length with grade [C40/20]. Cut-off piles. Rate to include preparing heads. Driven Cast In situ Concrete Piles [900 mm] diameter cast in situ concrete piles as working piles. H221 Drive [12 mm] thick mild steel casing in earth for [50] nos. of pile points. Rate to include pre-boring. m Unit t Qty. Rate Amount (RM)

H216

H217 H218

m nr

H222

Boring through rock. Rate to include natural and artificial hard material. Reinforcement straight bars nominal diameter:

H224

High tensile reinforcement straight bars, nominal diameter not exceeding 20mm. Rate to include supporting reinforcement. High tensile reinforcement straight bars, nominal diameter exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement 12 mm diameter helical bars. Rate to include supporting reinforcement.

H225

H226

H227 H228

Concreted length with grade [40/20]. Cut-off piles. Rate to include preparing heads. Caisson Piles [2500 mm] diameter caisson piles as working piles.

m nr

H231

Excavate in earth, up to [20 m] for [25] nos. of pile points. Excavate through rock, up to [10 m] for [25] nos. of pile points. Rate to include natural and artificial hard material. [20 mm] thick mild steel permanent casings. Rate to include the supply and jointing of casings, driving heads, and shoes.

H232

H233

Page Total carried to Summary of Class H

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class H: Piling Work Page BQH53 of BQH173

CLASS H Piling Work


Item No. Code No. H234 Description High tensile reinforcement straight bars, nominal diameter not exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement straight bars, nominal diameter exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement helical bars. Rate to include supporting reinforcement. Concreted length with grade [C40/20]. Micropiles [200 mm] diameter micropiles as working piles. H241 Boring in earth, up to [20 m] for [30] nos. of pile points. m Unit t Qty. Rate Amount (RM)

H235

H236

H237

H242

Boring through rock, up to [10 m] for [30] nos. of pile points. Rate to include natural and artificial hard material. Supply and install [127 mm OD x 9 mm thick Grade N80 API pipe]. High tensile reinforcement straight bars, nominal diameter not exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement straight bars, nominal diameter exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement helical bars. Rate to include supporting reinforcement. Grouting with non-shrink cement grout Grade [C30] as specified into drilled hole. Rate shall include excess cement required when the grout volume exceeded the theoretical volume. Cut-off piles. Rate to include preparing heads. Precast Reinforced Concrete Piles [200 mm] G40 square precast reinforced concrete piles with a working load of [.] kN.

H243

H244

H245

H246

H247

m3

H248

nr

H251.1

Supply initial piles with rock shoes of [12 m] length.

nr

H251.2

Supply extension piles of [9 m] length.

nr

Page Total carried to Summary of Class H

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class H: Piling Work Page BQH54 of BQH173

CLASS H Piling Work


Item No. Code No. H252.1 H252.2 H252.3 H253 Depth driven. Depth driven raked at inclination ratio of [1:6]. Depth driven using jack-in method. Pre-boring, [18.0 m] depth. Rate to include backfilling between the pile and the bore. Jointing with butt weld all round as shown in Drawing No. (.). Cut-off piles. Rate to include preparing heads. Precast Prestressed Concrete Piles [600 mm] diameter spun piles with a working load of [.] kN. H261.1 Supply initial pile with rock shoes of [12 m] length. nr Description Unit m m m m Qty. Rate Amount (RM)

H254

nr

H256

nr

H261.2 H262.1 H262.2 H262.3 H263

Supply extension pile of [9 m] length. Depth driven. Depth driven raked at inclination ratio of [1:6]. Depth driven using jack-in method. Pre-boring, [18.0 m] depth. Rate to include backfilling between the pile and the bore. Jointing with butt weld all round as shown in Drawing No. (.). Filling hollow piles with concrete grade [C30]. Rate to include removal of materials from within the piles before concreting. Cut-off piles. Rate to include preparing heads. Steel H-Piles 533 mm x 210 mm x 138 kg/m UB Grade 43A.

nr m m m m

H264

nr

H265

H266

nr

H271

Supply of steel H-piles with metal-filled primers of [6 m] length. Rate to include cathodic protection using the impressed current system as per Specification clause (..). Depth driven. Depth driven raked at inclination ratio of [1:6]. Depth driven using jack-in method.

nr

H272.1 H272.2 H272.3

m m m

Page Total carried to Summary of Class H

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class H: Piling Work Page BQH55 of BQH173

CLASS H Piling Work


Item No. Code No. H273 Description Jointing with welded splice plates as shown in Drawing No. (..). Cut-off piles. Rate to include preparing heads. Steel Pipe Piles [323.9 OD x 10 mm thick x 77.4 kg/m] mild steel pipe piles Grade 43A. H281 Supply of steel pipe piles with metal-filled primers of [9 m] length. Rate to include cathodic protection using the sacrificial anode system as per Specification clause (..). Depth driven. Depth driven raked at inclination ratio of [1:6]. Depth driven using jack-in method. Jointing with butt weld all round as shown in Drawing No. (.). Cut-off piles. Rate to include preparing heads. PILES Timber Piles [150 mm square] Grade B, Kempas timber piles pressure treated with CCA. H311 H312.1 H312.2 H312.3 H313 Supply in [12 m] length. Depth driven. Depth driven raked at inclination ratio of [1:6]. Depth driven using jack-in method. Jointing using mild steel welded boxes [450 mm] long fabricated from 5 mm thick plates. Cut-off piles. Rate to include preparing heads. Precast Prestressed Concrete Sheet Piles [996 mm wide x 325 mm high x 110 mm thick] with cross section area of 1315 cm2 precast pretressed concrete sheet piles. H321 H322 H323 Supply in [12 m] length. Depth driven. Cut-off piles. Rate to include preparing heads. nr m2 m nr m m m nr nr Unit nr Qty. Rate Amount (RM)

H274

nr

H282.1 H282.2 H282.2 H283

m m m nr

H284 H300

nr

H314

nr

Page Total carried to Summary of Class H

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class H: Piling Work Page BQH56 of BQH173

CLASS H Piling Work


Item No. Code No. Description Interlocking Steel Sheet Piles Interlocking Grade 43A steel sheet piles, [Z-section] , at 66.1 kg/m, section modulus of 1200 cm/m. Unit Qty. Rate Amount (RM)

H331 H332 H333

Supply in [12 m] length. Depth driven. Special piles for 90o corners with mass of 14.4 kg/m.

m m2 m

H334 H335

Cut-off piles. Rate to include preparing heads. 305 mm x 165 mm x 54 kg/m Grade 43A universal beam as waling. Rate to include supply and installation.

m m

H336

[Type 1] ground anchor as shown in Drawing No. (.).

nr

H400

MISCELLANEOUS WORK Obstructions

H411

Excavation through obstructions for [900 mm diameter bored piles].

H500 H510.1

PILE TESTS Initial static load test on 900 mm diameter bored pile up to two times working load of 16,000 kN. Subsequent static load test, on 900 mm diameter bored pile up to two times working load of 16,000 kN (Test load of 32,000 kN). Static load test on preliminary 300 mm diameter precast prestressed concrete pile to failure (Test load of .kN). nr

H510.2

nr

H510.3

nr

H520

PDA test on [300 mm] diameter prestressed concrete pile. Pile integrity test (sonic echo test) on [300 mm] diameter prestressed concrete pile. Sonic logging test on 900 mm diameter bored piles as per Specification clause (.). Lateral test on [300 mm] diameter prestressed concrete pile. Statnamic test on [300 mm] diameter prestressed concrete pile. Page Total carried to Summary of Class H

nr

H530

nr

H540

nr

H550

nr

H560

nr

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class H: Piling Work Page BQH57 of BQH173

CLASS H Piling Work


Item No. Code No. Description Summary of Class H: Piling Work Page BQH1 Page BQH2 Page BQH3 Page BQH4 Page BQH5 Page BQH6 Unit Qty. Rate Amount (RM)

Total of Class H carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class H: Piling Work Page BQH58 of BQH173

CLASS I Concrete Work


Item No. Code No. I100 Description IN SITU CONCRETE DESIGN MIX Rate for in situ concrete designed mix shall be deemed to include placing and compaction of concrete. Unit Qty. Rate Amount (RM)

Grade C15 Concrete I111.1 I111.2 Mass concrete blinding, [50 mm] thick [to footing]. Mass concrete blinding, [50 mm] thick [to raft foundation]. Mass concrete benching to sumps. Grade: C20 I121 Mass concrete blinding, [75 mm] thick [to clear water tank]. Mass concrete benching to sumps. Mass concrete benching to trenches. Mass concrete surround to pipes. Mass concrete screed to fall for roof. Grade: C25 I132.1 I132.2 I132.3 I132.4 I133 I134 I135 I136 Reinforced concrete to base of [valve chamber]. Reinforced concrete to footing of [guard house]. Reinforced concrete to pile caps of [workshop]. Reinforced concrete to ground slab to [store]. Reinforced concrete to olumns of [guard house]. Reinforced concrete beams to [workshop]. Reinforced concrete to walls of [valve chambers]. Reinforced concrete to suspended slabs [at first floor of workshop]. Other concrete forms, reinforced concrete to [steps and staircase]. m3 m3 m3 m3 m3 m3 m3 m3 m2 m2 m2

I112

m3

I122.1 I122.2 I122.3 I122.4

m3 m3 m3 m3

I137

m3

Page Total carried to Summary of Class I Class I: Concrete Work Page BQI59 of BQI173

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

CLASS I Concrete Work


Item No. Code No. Grade: C30 I142.1 I142.2 Reinforced concrete base to [trenches]. Reinforced concrete footings to [Administration Building]. Reinforced concrete pile caps to [Workshop]. Reinforced concrete ground slab to [Workshop]. Reinforced concrete columns to [Administration Building]. Reinforced concrete beams to [Administration Building]. Reinforced concrete walls to [trenches]. Reinforced concrete to suspended slabs [at first floor of workshop]. Other concrete forms, reinforced concrete to [steps and staircase]. Grade: C35 I152.1 I152.2 Reinforced concrete base to [elevated water tank]. Reinforced concrete to footings [of TNB sub-station]. m3 m3 m3 m3 Description Unit Qty. Rate Amount (RM)

I142.3 I142.4 I143

m3 m3 m3

I144

m3

I145 I146

m3 m3

I147

m3

I152.3 I152.4 I153.1

Reinforced concrete pile caps. Reinforced concrete ground slabs. Reinforced concrete to columns for [Chlorine Building].

m3 m3 m3

I153.2

Reinforced concrete to piers for [pedestrian brudge].

m3

I154 I155 I156

Reinforced concrete beams to [pedestrian bridge]. Reinforced concrete walls to [bridge abutment]. Reinforced concrete suspended slabs to [bridge deck].

m3 m3 m3

I157

Other concrete forms.

m3

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI60 of BQI173

CLASS I Concrete Work


Item No. Code No. Grade: C35A I162 I163 Reinforced concrete bases to [clear water tank]. Reinforced concrete columns to [clear water tank]. m3 m3 Description Unit Qty. Rate Amount (RM)

I164

Reinforced concrete beams [to support static mixer].

m3

I165 I166

Reinforced concrete walls to [clear water tank]. Reinforced concrete suspended [flat] slabs to [roof of clear water tank]. Other concrete forms mass concrete benching to [washwater channel]. Grade: C40

m3 m3

I167

m3

I172.1 I172.2 I172.3 I172.4 I173.1 I173.2 I174 I175 I176 I177

Reinforced concrete bases. Reinforced concrete footings. Reinforced concrete pile caps. Reinforced concrete ground slabs. Reinforced concrete columns. Reinforced concrete piers. Reinforced concrete beams. Reinforced concrete walls. Reinforced concrete suspended slabs. Other concrete forms. Grade: C50

m3 m3 m3 m3 m3 m3 m3 m3 m3 m3

I182.1 I182.2 I182.3 I182.4 I183.1 I183.2

Reinforced concrete bases. Reinforced concrete footings. Reinforced concrete pile caps. Reinforced concrete ground slabs. Reinforced concrete columns. Reinforced concrete piers.

m3 m3 m3 m3 m3 m3

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI61 of BQI173

CLASS I Concrete Work


Item No. Code No. I184 I185 I186 I187 Description Reinforced concrete beams. Reinforced concrete walls. Reinforced concrete suspended slabs. Other concrete forms. Unit m3 m3 m3 m3 Qty. Rate Amount (RM)

I200

IN SITU CONCRETE PRESCRIBED MIX Rate for in situ concrete prescribed mix shall be deemed to include placing and compaction of concrete.

1:3:6 I211 I212 Mass concrete blinding, [50 mm] thick [to footing]. Mass concrete benching to sumps. 1:2:4 I221 Mass concrete blinding, [75 mm] thick [to clear water tank]. Mass concrete benching to sumps. Mass concrete benching to trenches. Mass concrete surround to pipes. Mass concrete screed to fall for roof. Reinforced concrete columns. Reinforced concrete beams. Reinforced concrete walls. Reinforced concrete suspended slabs. Other concrete forms. 1:1.5:3 I232.1 I232.2 Reinforced concrete base to [trenches]. Reinforced concrete footings to [Administration Building]. Reinforced concrete pile caps to [Workshop]. Reinforced concrete ground slab to [Workshop]. m3 m3 m2 m2 m3

I222.1 I222.2 I222.3 I222.4 I223 I224 I225 I226 I227

m3 m3 m3 m3 m3 m3 m3 m3 m3

I232.3 I232.4

m3 m3

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI62 of BQI173

CLASS I Concrete Work


Item No. Code No. I233 Description Reinforced concrete columns to [Administration Building]. Reinforced concrete beams to [Administration Building]. Reinforced concrete walls to [trenches]. Reinforced concrete to suspended slabs [at first floor of workshop]. Other concrete forms, reinforced concrete to [steps and staircase]. 1:1:2 I242.1 Reinforced concrete base to [elevated water tank]. m3 Unit m3 Qty. Rate Amount (RM)

I234

m3

I235 I236

m3 m3

I237

m3

I242.2

Reinforced concrete to footings [of TNB sub-station].

m3

I242.3 I242.4 I243

Reinforced concrete pile caps. Reinforced concrete ground slabs. Reinforced concrete to columns for [Chlorine Building].

m3 m3 m3

I244

Reinforced concrete beams to [pedestrian bridge].

m3

I245 I246

Reinforced concrete walls to [bridge abutment]. Reinforced concrete suspended slabs to [bridge deck].

m3 m3

I247

Other concrete forms.

m3

I300

PRECAST CONCRETE Item for precast concrete shall be deemed to include reinforcement, formwork, joints, and finishes; and items for prestressed precast units shall include prestressing.

I310.1

[Grade C35] [400 mm x 300 mm x 4 m long] columns to first floor. [Grade C45] columns with dimension as shown in Drawing No. () to mezzanine floor.

nr

I310.2

nr

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI63 of BQI173

CLASS I Concrete Work


Item No. Code No. I320 Description [Grade 45] [600 mm x 300 mm x 6 m long] beams to first floor. [Grade 45] prestressed pre-tensioned main beam, [ Isection 800 mm x 1400 mm x 22 m long] as per Drawing No. (..) and Specification clause (). Unit nr Qty. Rate Amount (RM)

I330

nr

I340

[Grade 45] Prestressed post-tensioned main beam,[ Tsection 800 mm x 1400 mm x 22 m long] as per Drawing No. (..) and Specification clause ().

nr

I350

[Grade 35], 6 m x 3 m x 150 mm thick walls to the first floor up to the fourth floor. [Grade 35] [half] slab, [3 m x 2 m x 75 mm thick] to the first floor. Segmental units with dimensions as shown in Drawing No. () Units for subways and vehicular or pedestrian culverts and ducts with dimensions as shown in Drawing No. (.)

nr

I360

nr

I370

nr

I380

I400

FORMWORK Rate for formwork shall be deemed to include the projections and intrusions and any temporary staging required. Sides

I411.1 I411.2 I411.3 I411.4 I412.1 I412.2 I412.3 I412.4 I413.1 I413.2 I414.1

F1: rough finish to bases. F1: rough finish to footings. F1: rough finish to pile caps. F1: rough finish to ground slabs. F2: fair finish to columns. F2: fair finish to piers. F3: smooth finish to columns. F3: smooth finish to piers. F2: fair finish to beams. F3: smooth finish to beams. F2: fair finish to walls.

m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI64 of BQI173

CLASS I Concrete Work


Item No. Code No. I414.2 I414.3 Description F3: smooth finish to walls. F3: smooth finish to walls, curved on plan. Soffit I425.1 I425.2 I425.3 F2: fair finish to suspended slabs. F3: smooth finish to suspended slabs. F3: smooth finish to curved roof slabs. Sides and Soffit I433.0 I433.0 F2: fair finish to beams. F3: smooth finish to beams. Sloping I441 F2: fair finish to upper surface to base, [height 0.3 0.5 m]. F2: fair finish to columns, [0.3 0.4 m]. F3: smooth finish to walls, [width 0.6 m 0.3 m]. For Voids I451 I452 [300 x 300 x 150 mm deep] opening. [1 m x 2 m x 1.5 m deep] opening in wall. nr m2 m2 m2 m2 m2 m2 m2 Unit m2 m2 Qty. Rate Amount (RM)

I442 I444

m2 m2

I500

REINFORCEMENT Rate for reinforcement shall be deemed to include labour for cutting, bending, and placing. Mild Steel Bars

I511 I512 I513 I514 I515 I516 I517

Nominal diameter: 6 mm. Nominal diameter: 10 mm. Nominal diameter: 12 mm. Nominal diameter: 16 mm. Nominal diameter: 20 mm. Nominal diameter: 25 mm. Nominal diameter: 32 mm.

t t t t t t t

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI65 of BQI173

CLASS I Concrete Work


Item No. Code No. I518 Description Nominal diameter: larger than 40 mm. High Tensile Bars I521 I522 I523 I524 I525 I526 I527 I528 Nominal diameter: 6 mm. Nominal diameter: 10 mm. Nominal diameter: 12 mm. Nominal diameter: 16 mm. Nominal diameter: 20 mm. Nominal diameter: 25 mm. Nominal diameter: 32 mm. Nominal diameter: larger than 40 mm. Reinforcing Bars of Other Stated Material I531 I532 I533 I534 I535 I536 I537 I538 I540.1 Nominal diameter: 6 mm. Nominal diameter: 10 mm. Nominal diameter: 12 mm. Nominal diameter: 16 mm. Nominal diameter: 20 mm. Nominal diameter: 25 mm. Nominal diameter: 32 mm. Nominal diameter: larger than 40 mm. Special joints using [500 mm long] mechanical grip sleeve as per Specification clause () to [20 mm nominal diameter high tensile bars]. Special joints using [600 mm long sleeve filled with epoxy] as per Specification clause (.) to [20 mm nominal diameter high tensile bars]. High tensile steel fabric mesh A98 (A4), 1.54 kg/m2. t t t t t t t t nr t t t t t t t t Unit t Qty. Rate Amount (RM)

I540.2

nr

I550.1

m2

I550.2

High tensile steel fabric mesh A142 (A5), 2.22 kg/m2.

m2

I550.3

High tensile steel fabric mesh A193 (A7), 3.02 kg/m2.

m2

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI66 of BQI173

CLASS I Concrete Work


Item No. Code No. I550.4 Description High tensile steel fabric mesh A252 (A8), 3.95 kg/m2. Unit m2 Qty. Rate Amount (RM)

I550.5

High tensile steel fabric mesh A393 (A10), 6.16 kg/m2. High tensile steel fabric mesh B196 (B5), 3.05 kg/m2.

m2

I550.6

m2

I550.7

High tensile steel fabric mesh B283 (B6), 3.73 kg/m2.

m2

I550.8

High tensile steel fabric mesh B385 (B7), 4.53 kg/m2.

m2

I550.9

High tensile steel fabric mesh B503 (B8), 5.93 kg/m2.

m2

I550.10

High tensile steel fabric mesh B785 (B10), 8.14 kg/m2. High tensile steel fabric mesh B1131 (B12), 10.90 kg/m2. High tensile steel fabric mesh C283 (C6), 2.61 kg/m2.

m2

I550.11

m2

I550.12

m2

I550.13

High tensile steel fabric mesh C385 (C7), 3.41 kg/m2.

m2

I550.14

High tensile steel fabric mesh C503 (C8), 4.34 kg/m2.

m2

I550.15

High tensile steel fabric mesh C636 (C9), 5.55 kg/m2.

m2

I550.16

High tensile steel fabric mesh C785 (C10), 6.72 kg/m2. Fabric of other stated material.

m2

I560

m2

I600

CONCRETE ANCILLARIES Joints Rate for joints shall be deemed to include formwork.

I611 I612

Construction joint, [150 mm wide]. Contraction joints, [200 mm wide]. [Rate to include surface of joint with two coats of polyether paint].

m m

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI67 of BQI173

CLASS I Concrete Work


Item No. Code No. I613 Description Expansion joints, [250 mm wide]. [Rate to include 25 mm thick resin bonded cork filler]. [230 mm] wide rubber waterstop. Rate to include cutting and jointing of waterstops and provision of special fittings at angles and junctions. [230 mm] wide rubber waterstop with central bulb. Rate to include cutting and jointing of waterstops and provision of special fittings at angles and junctions. Unit m Qty. Rate Amount (RM)

I614.1

I614.2

I615.1

Sealed [20 mm x 20 mm] grooves with polyether sealant.

I615.2

Sealed [40 mm x 20 mm] grooves with polyether sealant.

I616

Dowels plain, [25 mm diameter x 300 mm long] steel bars at [600 mm] centres. Dowels sleeved and capped, [25 mm diameter x 300 mm long] steel bars at [600 mm] centres. Post-Tensioned Prestressing Rate for prestressing shall be deemed to include ducts, jacking, grouting, and other components and tasks ancillary to prestressing.

nr

I617

nr

I621

Horizontal internal tendons in in situ concrete, [seven] wire standard strand to BS 5896, Class 1; [nominal diameter 12 mm]; concrete cone anchors to BS 1477, [7 10] length for Beam No. [2]. Inclined internal tendons in in situ concrete, [seven] wire standard strand to BS 5896, Class 1; [nominal diameter 12 mm]; concrete cone anchors to BS 1477, [7 10] length for Beam No. [2].

nr

I622

nr

I623

Horizontal internal tendons in precast concrete, [seven] wire standard strand to BS 5896, Class 1; [nominal diameter 12 mm]; concrete cone anchors to BS 1477, [7 10] length for Beam No. [2]. Inclined internal tendons in precast concrete, [seven] wire standard strand to BS 5896, Class 1; [nominal diameter 12 mm]; concrete cone anchors to BS 1477, [7 10] length for Beam No. [2]. Finishing of Top Surfaces Rate for finishing of top surfaces shall be deemed to include wood float or steel trowel.

nr

I624

nr

I631

Power float.

m2

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI68 of BQI173

CLASS I Concrete Work


Item No. Code No. I632 I633 Class U3 finish. Class U4 finish. Finishing of Formed Surfaces I641 I642 I643 Aggregate exposure using retarder. Bush hammering. Other stated surface treatment carried out after striking formwork. Inserts I651 I652.1 100 mm diameter GVC pipe. 10 mm diameter, 25 mm deep expanding bot projecting from one surface. 15 mm diameter, 40 mm deep rag bolt projecting from one surface. 25 mm diameter, 100 mm long mild steel holding down bolt projecting from one concrete surface. 150 mm DN ductile iron pipe with puddle flange, projecting from both surfaces of concrete. Grouting with [1:3 cement sand motar] under plate of size [200 mm x 200 mm]. m nr m2 m2 m2 Description Unit m2 m2 Qty. Rate Amount (RM)

I652.2

nr

I652.3

nr

I652.4

nr

I660

nr

I700

ANCILLARY WORK FOR WATER RETAINING STRUCTURE Water proofing admixtures using [XYPEX] or equivalent to be in mix proportion as recommended by the manufacturer. Water tightness testing of [1000 m3 clear water] tanks. Rate to include provision of water and all testing equipment as per Specification clause (..). m3

I710

I720

m3

I730

Sterilizing and flushing of [1000 m3 clear water] tank. Rate to include provision of potable water and chemicals as per Specification clause (..). Linings and Coatings Rate for linings and coatings shall be deemed to include supply and installation/application.

m3

I741

[20 mm thick] high alumina cement lining to [inlet chamber].

m2

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI69 of BQI173

CLASS I Concrete Work


Item No. Code No. I742 Description [1 mm thick] PVC lining as per Specification clause (.) to sludge tanks. [2 mm thick] HDPE lining as per Specification clause (.) to sludge tanks. Sodium silicate solution as per Specification clause (.) to internal surfaces in contact with water of reservoir. Unit m2 Qty. Rate Amount (RM)

I743

m2

I744

m2

I745

Epoxy coatings as per Specification clause (.) to sludge tanks.

m2

Page Total carried to Summary of Class I

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI70 of BQI173

CLASS I Concrete Work


Item No. Code No. Description Summary of Class I: Concrete Work Page BQI1 Page BQI2 Page BQI3 Page BQI4 Page BQI5 Page BQI6 Page BQI7 Page BQI8 Page BQI9 Page BQI10 Page BQI11 Page BQI12 Unit Qty. Rate Amount (RM)

Total of Class I carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class I: Concrete Work Page BQI71 of BQI173

CLASS J Brickwork, Blockwork, and Masonry


Item No. Code No. J100 BRICKWORK Item for brickwork shall be deemed to include joint reinforcement, movement joints, fixing ties, bonds to existing work, and fixing clamps. J111.1 [115 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical straight walls. [115 mm] thick [cement sand brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical straight walls. [230 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical straight walls. [230 mm] thick [cement sand brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical straight walls. [115 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical straight walls cavity wall construction type. m2 Description Unit Qty. Rate Amount (RM)

J111.2

m2

J111.3

m2

J111.4

m2

J111.5

m2

J121.1

[115 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical curved walls. [230 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical curved walls. [Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for battered straight walls, average thickness of [172.5 mm], varying from 230 mm to 115 mm. [Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for battered curved walls, average thickness of [172.5 mm], varying from [230 mm to 115 mm]. [115 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar as vertical facing to concrete. [Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for battered facing to concrete, average thickness of [172.5 mm], varying from [230 mm to 115 mm].

m2

J121.2

m2

J131

m2

J141

m2

J151

m2

J161

m2

Page Total carried to Summary of Class J

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class J: Brickwork, Blockwork and Masonry Page BQJ72 of BQJ173

CLASS J Brickwork, Blockwork, and Masonry


Item No. Code No. J171 Description [115 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for casing to metal sections. [Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for [600 mm x 600 mm] column. Unit m2 Qty. Rate Amount (RM)

J180.1

m3

J180.2

[Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for [600 mm x 600 mm] piers.

m3

J200

BLOCKWORK
Item for blockwork shall be deemed to include joint reinforcement, movement joints, fixing ties, bonds to existing work, and fixing clamps.

J211

[115 mm] thick lightweight blockwork laid in stretcher bond and jointed in [1:3] cement mortar for vertical straight walls. [115 mm] thick lightweight blockwork laid in stretcher bond and jointed in [1:3] cement mortar for vertical curved walls. [115 mm] thick lightweight blockwork laid in stretcher bond and jointed in [1:3] cement mortar as vertical facing to concrete. [115 mm] thick lightweight blockwork laid in stretcher bond and jointed in [1:3] cement mortar for casing to metal sections. [Lightweight blockwork] laid in stretcher bond, jointed in [1:3] cement mortar for [600 mm x 600 mm] column.

m2

J221

m2

J251

m2

J271

m2

J280.1

m3

J280.2

[Lightweight blockwork] laid in stretcher bond, jointed in [1:3] cement mortar for [600 mm x 600 mm] piers.

m3

J300

MASONRY Item for masonry shall be deemed to include fair face finish.

J311

[300 mm] thick natural stone masonry jointed in [1:3] cement mortar flush pointed for vertical straight walls.

m2

J321

[300 mm] thick natural stone masonry jointed in [1:3] cement mortar flush pointed for vertical curved walls.

m2

Page Total carried to Summary of Class J

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class J: Brickwork, Blockwork and Masonry Page BQJ73 of BQJ173

CLASS J Brickwork, Blockwork, and Masonry


Item No. Code No. J331 Description Natural stone masonry jointed in [1:3] cement mortar flush pointed for battered straight walls, average thickness of [172.5 mm], varying from [230 mm to 115 mm]. Natural stone masonry jointed in [1:3] cement mortar flush pointed for battered curved walls, average thickness of [225 mm], varying from [300 mm to 150 mm]. [300 mm] thick natural stone masonry jointed in [1:3] cement mortar flush pointed as vertical facing to concrete. Natural stone masonry jointed in [1:3] cement mortar flush pointed for battered facing to concrete, average thickness of [172.5 mm], varying from [230 mm to 115 mm]. [200 mm] thick natural stone masonry jointed in [1:3] cement mortar flush pointed for casing to metal sections. Unit m2 Qty. Rate Amount (RM)

J342

m2

J351

m2

J361

m2

J371

m2

J380.1

Natural stone masonry jointed in [1:3] cement mortar flush pointed for [600 mm x 600 mm] column.

m3

J380.2

Natural stone masonry jointed in [1:3] cement mortar flush pointed for [600 mm x 600 mm] piers.

m3

J400

MISCELLANEOUS WORK Surface Features

J411.1 J411.2 J411.3 J411.4 J412 J413

Brick on edge coping. Bullnosed copings. Rounded copings as shown in Drawing No. (). Special sills as shown in Drawing No. (). [100 mm] deep rebates in brickwall. Decorative cornices as shown in Drawing No. (.).

m m m m m m

J414

Band courses for brickwall as shown in Drawing No. (..). Bullnose corbel as shown in Drawing No. (.).

J415

J416

Common brickwork pilasters as shown in Drawing No. (.).

Page Total carried to Summary of Class J

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class J: Brickwork, Blockwork and Masonry Page BQJ74 of BQJ173

CLASS J Brickwork, Blockwork, and Masonry


Item No. Code No. J417 J418 Description Brickwork plinths as shown in Drawing No. (.). [115 mm] thick fair facing brickwork. Ancillaries J421 Damp proof courses; width [115mm] to BS 743 Type D. m Unit m m2 Qty. Rate Amount (RM)

J422 J423.1 J423.2

Concrete Grade C20 infills of 50 mm thick. Built-in 150 mm DN uPVC drainage pipes. Built-in 50 mm DN uPVC cable ducts.

m2 nr nr

Page Total carried to Summary of Class J

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class J: Brickwork, Blockwork and Masonry Page BQJ75 of BQJ173

CLASS J Brickwork, Blockwork, and Masonry


Item No. Code No. Description Summary of Class J: Brickwork, Blockwork, and Masonry Page BQJ1 Page BQJ2 Page BQJ3 Page BQJ4 Unit Qty. Rate Amount (RM)

Total of Class J carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class J: Brickwork, Blockwork and Masonry Page BQJ76 of BQJ173

CLASS K Timber Work


Item No. Code No. Description Timber work shall be deemed to include fixing components, fixing, fastening, boring, cutting, and jointing. K100 TIMBER COMPONENTS Grade A Heavy Hardwood; Wrot Finish K111.1 [150 mm x 150 mm cengal to columns]; length not exceeding 6 m. [100 mm x 50 mm cengal to floor joist]; length not exceeding 6 m. [200 mm x 75 mm cengal to floor girders]; length exceeding 6 m. Grade B Medium Hardwood; Wrot Finish K121.1 [150 mm x 75 mm keruing ] with preservative treatment as per Specification clause (.) to [floor joists, girders, column..]; length not exceeding 6 m. [150 mm x 75 mm keruing ], kiln dry as per Specification clause (.) to [floor joists, girders, column..]; length not exceeding 6 m. [150 mm x 75 mm keruing ] with preservative treatment as per Specification clause (.) to [girders, ..]; length exceeding 6 m. [150 mm x 75 mm keruing ], kiln dry as per Specification clause (.) to [girders, ..]; length exceeding 6 m. Grade C Light Hardwood; Wrot Finish K131.1 [150 mm x 75 mm meranti ] with preservative treatment as per Specification clause (.) to [floor joists, girders, column..]; length not exceeding 6 m. [150 mm x 75 mm meranti ], kiln dry as per Specification clause (.) to [floor joists, girders, column..]; length not exceeding 6 m. [150 mm x 75 mm meranti ] with preservative treatment as per Specification clause (.) to [girders, ..]; length exceeding 6 m. [150 mm x 75 mm meranti ], kiln dry as per Specification clause (.) to [girders, ..]; length exceeding 6 m. m m m Unit Qty. Rate Amount (RM)

K111.2

K112

K121.2

K122.1

K122.2

K131.2

K132.1

K132.2

Page Total carried to Summary of Class K

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class K: Timber Work Page BQK77 of BQK173

CLASS K Timber Work


Item No. Code No. Description Grade D Softwood; Wrot Finish K141 [150 mm x 75 mm damar minyak ], kiln dry as per Specification clause (.) to [floor joists, girders, column..]; length not exceeding 6 m. m Unit Qty. Rate Amount (RM)

K142

[150 mm x 75 mm damar minyak ], kiln dry as per Specification clause (.) to [girders, ..]; length exceeding 6 m.

K200

DECKING AND BOARDING Rate for decking and boarding shall be deemed to include framework where expressly required; walls and soffits shall include for any temporary staging required. Grade A Heavy Hardwood; Wrot Finish

K211

[150 mm wide x 32 mm thick balau ] floor deck boards. [100 mm wide x 12 mm thick balau ] panelling to wall. [Rate to include 50 mm x 50 mm balau studs at 600 mm centres as framework].

m2

K212.1

m2

K212.2

[150 mm wide x 40 mm thick cengal ] baffle wall to flocculation tanks. [100 mm wide x 12 mm thick balau ] panelling to ceiling. [Rate to include 50 mm x 50 mm balau studs at 600 mm centres as framework].

m2

K213

m2

Grade B Medium Hardwood; Wrot Finish K221 [150 mm wide x 32 mm thick kempas ] with [preservative treatment] as per Specification clause (.) to floor deck. [100 mm wide x 12 mm thick keruing ] with [peservative treatment to Specification clause (..)] to wall panelling. [Rate to include 50 mm x 50 mm keruing studs at 600 mm centres as framework]. m2

K222

m2

K223

[100 mm wide x 12 mm thick keruing ] with [peservative treatment to Specification clause (..)] for panelling to ceiling. [Rate to include 50 mm x 50 mm balau studs at 600 mm centres as framework].

m2

Page Total carried to Summary of Class K

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class K: Timber Work Page BQK78 of BQK173

CLASS K Timber Work


Item No. Code No. Description Grade C lLght Hardwood; Wrot Finish K231 [150 mm wide x 25 mm thick nyatoh ] with [preservative treatment] as per Specification clause (.) to floor deck. [100 mm wide x 12 mm thick nyatoh ] with [peservative treatment to Specification clause (..)] to wall panelling. [Rate to include 50 mm x 50 mm keruing studs at 600 mm centres as framework]. m2 Unit Qty. Rate Amount (RM)

K232

m2

K233

[100 mm wide x 12 mm thick nyatoh ] with [peservative treatment to Specification clause (..)] for panelling to ceiling. [Rate to include 50 mm x 50 mm balau studs at 600 mm centres as framework].

m2

Grade D Softwood; Wrot Finish K241.1 [150 mm wide x 12 mm thick damar minyak ], [kiln dry as per Specification clause (.) to floor deck]. m2

K241.2

[150 mm wide x 12 mm thick sempilor ], [kiln dry as per Specification clause (.) to floor deck. [Rate to include 75 mm x 50 mm sempilor floor joists at 600 mm centres]. [100 mm wide x 12 mm thick damar minyak ], kiln dry as per Specification clause (..)] to wall panelling. [Rate to include 50 mm x 50 mm damar minyak studs at 600 mm centres as framework].

m2

K242

m2

K243

[100 mm wide x 12 mm thick nyatoh ], kiln dry as per Specification clause (..)] for panelling to ceiling. [Rate to include 50 mm x 50 mm damar minyak studs at 600 mm centres as framework].

m2

K300

MISCELLANEOUS WORK Grade A Heavy Hardwood; Wrot Finish

K311

[100 mm high x 12 mm thick chengal ] wall skirting to [floor]. [Cengal ] hand rails with 75 mm x 75 mm post and 75 mm x 50 mm rails as shown in Drawing No. ().

K312

Page Total carried to Summary of Class K

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class K: Timber Work Page BQK79 of BQK173

CLASS K Timber Work


Item No. Code No. K313 Description [100 mm high x 50 mm wide chengal] cornice to ceiling with profile as shown in Drawing No. (.). [50 mm wide x 25 mm high chengal] dado with profile as shown in Drawing No. (.) to be fixed at [1.2 m] from the finished floor level. Grade B Medium Hardwood; Wrot Finish K321 [100 mm high x 12 mm thick kempas ] wall skirting to [floor]. Timber to be treated with preservatives as per Specification clause (.). m Unit m Qty. Rate Amount (RM)

K314

K322

[Kempas ] hand rails with 75 mm x 75 mm post and 75 mm x 50 mm rails as shown in Drawing No. (). Timber to be treated with preservatives as per Specification clause (.).

K323

[100 mm high x 50 mm wide kempas] cornice to ceiling with profile as shown in Drawing No. (.). Timber to be treated with preservatives as per Specification clause (.).

K324

[50 mm wide x 25 mm high kempas] dado with profile as shown in Drawing No. (.) to be fixed at [1.2 m] from the finished floor level. Timber to be treated with preservatives as per Specification clause (.). Grade C Light Hardwood; Wrot Finish

K331

[100 mm high x 12 mm thick nyatoh ] wall skirting to [floor]. Timber to be treated with preservatives as per Specification clause (.).

K332

[Nyatoh ] hand rails with 75 mm x 75 mm post and 75 mm x 50 mm rails as shown in Drawing No. (). Timber to be treated with preservatives as per Specification clause (.).

K333

[100 mm high x 50 mm wide nyatoh] cornice to ceiling with profile as shown in Drawing No. (.). Timber to be treated with preservatives as per Specification clause (.).

K334

[50 mm wide x 25 mm high nyatoh] dado with profile as shown in Drawing No. (.) to be fixed at [1.2 m] from the finished floor level. Timber to be treated with preservatives as per Specification clause (.). Page Total carried to Summary of Class K

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class K: Timber Work Page BQK80 of BQK173

CLASS K Timber Work


Item No. Code No. Description Grade D Softwood; Wrot Finish K341 [100 mm high x 12 mm thick damar minyak ] wall skirting to [floor]. Timber to be kiln dry as per Specification clause (.). [Damar minyak ] hand rails with 75 mm x 75 mm post and 75 mm x 50 mm rails as shown in Drawing No. (). Timber to be kiln dry as per Specification clause (.). [100 mm high x 50 mm wide damar minyak] cornice to ceiling with profile as shown in Drawing No. (.). Timber to be treated with preservatives as per Specification clause (.). m Unit Qty. Rate Amount (RM)

K342

K343

K344

[50 mm wide x 25 mm high damar minyak] dado with profile as shown in Drawing No. (.) to be fixed at [1.2 m] from the finished floor level. Timber to be treated with preservatives as per Specification clause (.).

Page Total carried to Summary of Class K

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class K: Timber Work Page BQK81 of BQK173

CLASS K Timber Work


Item No. Code No. Description Su mmary of Class K: Timber Work Page BQK1 Page BQK2 Page BQK3 Page BQK4 Page BQK5 Unit Qty. Rate Amount (RM)

Total of Class K carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class K: Timber Work Page BQK82 of BQK173

CLASS L Metal Work


Item No. Code No. L100 Description SUPPLY AND ERECTION OF STRUCTURAL MEMBERS Item for supply and erection of structural members shall be deemed to include delivery, protective and/or decorative surface treatment, fabrication, handling, hoisting, welded connections, bolted connections using bolts of nominal diameter less than 16 mm, and nondestructive testing as per Specification clause (...). Unit Qty. Rate Amount (RM)

Supply and erection of structural members for frames; steel to [BS:4360]. Hot-Rolled Sections L111 [457 mm x 191 mm x 98 kg/m] mild steel universal column to [Grade 43A, BS 4360]. [457 mm x 152 mm x 82 kg/m] mild steel universal beam to [Grade 43A, BS 4360]. [406 mm x 146 mm x 32.74 kg/m] universal beam as portal frame as shown in Drawing No. (.). 15 m span mild steel truss, Grade 43A: BS 4360 for 250 mm DN pipe stream crossing as shown in Drawing No. (.). L114.1 L114.2 L114.3 L114.4 L115 203 mm x 102 mm x 23 kg/m universal beam. 150 x 75 x 10 mm thick x 17 kg/m angle. 80 x 80 x 8 mm thick x 9.63 kg/m angle. 60 x 60 x 6 mm thick x 5.42 kg/m angle. 12.5 mm thick x 103.1 kg/m2 Grade 43A mild steel chequred plates to BS 4360 as decking. [200 x 68 x 16 mm thick x 4.75 kg/m C-channel as wall bracings. [305 mm x 165 mm x 54 kg/m] universal beam at 800 mm centres as grillages. Cold-Rolled Sections L121 L122 [150 x 150 x 5 mm thick] box section as column. [200 x 100 x 5 mm thick] C-section as wall framing. t t t t t t t t

L112

L113

L116

L117

Page Total carried to Summary of Class L

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class L: Metalwork Page BQL83 of BQL173

CLASS L Metal Work


Item No. Code No. L125 Description [200 x 75 x 2 mm thick] hat-section as decking to composite floor concstruction. [200 x 68 x 2 mm] thick C-channel as wall bracings. Unit t Qty. Rate Amount (RM)

L126

Built-up or Fabricated Sections L131 [600 mm x 600 mm] built-up column comprising 20 mm thick steel plates as shown in Drawing No. (.). t

L132

Built-up box girders as shown in Drawing No. (..).

L133

Pre-engineered steel portal frame as shown in Drawing No. (.). Extruded Sections

L141

[76.1mm OD x 3.2mm thick x 5.75 kg/m] circular hollw section to [wall]. [50 x 30 x 2.6mm thick x 3.03 kg/m] rectangular hollow section to [wall] [48.3 mm OD x 3.2 mm thick x 3.56 kg/m] circular hollow section to frame as shown in Drawing No. (.).

L142

L144

L146

[200 x 68 x 16 mm x 4.75 kg/m] C-channel as wall bracings. Rate for black bolts shall be deemed to nuts, washers, gusset and end plates, and other accessories.

Black Bolts L151 L152 L153 L154 L155 L156 L157 L158 Nominal diameter: 16 20 mm. Nominal diameter: 20 24 mm. Nominal diameter: 24 30 mm. Nominal diameter: 30 36 mm. Nominal diameter: 36 42 mm. Nominal diameter: 42 48 mm. Nominal diameter: 48 56 mm. Nominal diameter of [60 mm]. nr nr nr nr nr nr nr nr

Page Total carried to Summary of Class L

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class L: Metalwork Page BQL84 of BQL173

CLASS L Metal Work


Item No. Code No. Description Items for high strength friction grip bolts shall be deemed to nuts, washers, gusset and end plates, and other accessories expressly required. High Strength Friction Grip Bolts L161 HSFG bolts to [BS 4604], nominal diameter [16 mm] with proof load of [92.1 kN]. HSFG bolts to [BS 4604], nominal diameter [22 mm] with proof load of [177 kN]. HSFG bolts to [BS 4604], nominal diameter [24 mm] with proof load of [207 kN]. HSFG bolts to [BS 4604], nominal diameter [30 mm] with proof load of [286 kN]. HSFG bolts to [BS 4604], nominal diameter [36 mm] with proof load of [418 kN]. HSFG bolts to [BS 4604], nominal diameter [42 mm] with proof load of [. kN]. HSFG bolts to [BS 4604], nominal diameter [48 mm] with proof load of [. kN]. HSFG bolts to [BS 4604], nominal diameter [60 mm] with proof load of [. kN]. Anchorages and Holding Down Bolt Assemblies L170 Anchorages and holding down bolt assemblies comprising [4 Nos. 450 x 24 bolts with plates 150 x 150 x 10 mm]. nr nr Unit Qty. Rate Amount (RM)

L162

nr

L163

nr

L164

nr

L165

nr

L166

nr

L167

nr

L168

nr

L200

MISCELLANEOUS METALWORK Item for miscellaneous metalwork shall be deemed to include fixing to other work, supply of fixing components, and drilling or cutting of other work.

L210

Stairways and landings; [150 mm riser with 250 mm treads] as per Drawing No. (..). [2 m] wide walkways as per Drawing No. (.). Galvanised mild steel ladders; [70 x 70 x 10 mm thick x 10.3 kg/m stringer 400 mm] apart, with [20 mm] diameter steel rungs at [300 mm] centres. Rate to include full assemblies.

nr

L220 L230

m2 m

Page Total carried to Summary of Class L

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class L: Metalwork Page BQL85 of BQL173

CLASS L Metal Work


Item No. Code No. Description Unit Qty. Rate Amount (RM)

L240

Galvanised mild steel handrail of 42.4 mm diameter tubular section of 3.2 mm thickness and 1100 mm high with fixing accessories as shown on the drawing.

L250

114.3 mm OD x 5.0 mm thick x 13.5 kg/m circular hollow section as parapets. Rate to include full assemblies. Decking Rate for decking shall be deemed to include supporting metalwork as framework.

L261

[8 mm] thick galvanised mild steel chequered plates trench covers. Galvanised mild steel open mesh cover complete with 50 mm x 50 mm x 5.82 kg/m angle frame built-in into the floor inclusive of RHS as supports. Welded mesh paneling. [6 mm] thick galvanised mild steel chequered plates flooring. [Colourbond metal deck, 0.48 mm] base steel thickness to wall cladding. 305 mm x 165 mm x 54 kg/m mild steel Grade 43A universal beam as waling.

m2

L262

m2

L263 L264

m2 m2

L270

m2

L280

L300

MISCELLANEOUS METALWORK Miscellaneous Framing

L311 L312

[50 x 50 x 5 mm thick x 3.77 kg/m] angle section. [102 mm x 51 mm x 10.42 kg/m] C-channel section.

m m

L313 L314

[152 mm x 89 mm x 17.09 kg/m] I-section. [100 x 50 x 3.2 mm thick x 7.18 kg/m] rectangular hollow section. Tanks

m m

L321

Uncovered metal steel tanks; capacity: [2140] litres; dimension: [3000 L x 1670 H x 465 W] as per Specification and as shown in the drawings. Covered stainless steel water tank; capacity: [1000] litres; grade [304]; dimension [1060 dia. x 1060 H] as per Specification and as shown in the drawings.

nr

L322

nr

Page Total carried to Summary of Class L

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class L: Metalwork Page BQL86 of BQL173

CLASS L Metal Work


Item No. Code No. Description Summary of Class L: Metalwork Page BQL1 Page BQL2 Page BQL3 Page BQL4 Unit Qty. Rate Amount (RM)

Total of Class L carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class L: Metalwork Page BQL87 of BQL173

CLASS M Building Work


Item No. Code No. M100 ROOFING WORK Timber Roof Structure Rate shall include connecting plates, bolts and nuts, and other fastening system. M111.1 [100 mm x 50 mm Group B] sawn timber rafter, as shown in Drawing No. (.). [50 mm x 25 mm Group B] sawn timber batten, as shown in Drawing No. (..). [150 mm x 50 mm Group B] sawn timber wall plate, as shown in Drawing No. (.). Timber roof truss system using Grade B sawn timber and components to be designed by Contractor as per Specification clause (.). Rate shall include connecting plates, bolts and nuts, and other fastening system. m Description Unit Qty. Rate Amount (RM)

M111.2

M111.3

M112

m2

Metal Roof Structure Rate to include connecting plates, bolts, nuts, all welding, and other fastening system. M113.1 [457 mm x 191 mm x 98 kg/m] mild steel universal column. [Grade 43A to BS 4360] as rafter as shown in Drawing No. (.). [75 x 75 x 4 mm thick x 8.60 kg/m] mild steel square hollow section, [Grade 43A to BS 4360] as top chord member as shown in Drawing No. (.). kg

M113.2

kg

M113.3

[150 x 75 x 4 mm thick x 18.60 kg/m] C-channel purlins. [Grade 43A to BS 4360] as shown in Drawing No. (.). [200 x 68 x 2 mm] thick cold formed galvanised mild steel C-channel as purlins. Mild steel, Grade 43A to BS 4360 roof truss system and components to be designed by Contractor as per Specification clause (.). Rate to include connecting plates, bolts, nuts, all welding, and other fastening system. Galvanised mild steel roof truss system and components using cold-rolled steel to be designed by Contractor as per Specification clause (.). Rate to include connecting plates, bolts, nuts, all welding, and other fastening system.

kg

M113.4

kg

M114.1

m2

M114.2

m2

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM88 of BQM173

CLASS M Building Work


Item No. Code No. Roof Covering Rate to include preparing surfaces, forming joints, overlaps, mitres, angles, fillets, built-up edges, and laying to falls or cambers, cutting, notching, bending, and bedding. M121.1 [6 mm thick polycarbonate flat sheet] as per Specification clause (.) laid at [15 degrees to the horizontal] as shown in Drawing No. (.). [6 mm thick polycarbonate flat sheet] as per Specification clause (.), [with curve at radius of 10 m] as shown in Drawing No. (.). [0.48 mm base steel thickness colourbond corrugated roofing sheet] as per Specification clause (.) laid at [15 degrees to the horizontal] as shown in Drawing No. (.). [Interlocking concrete roofing tiles] as per Specification clause (.) laid to [30 degrees to the horizontal ] as shown in Drawing No. (.). Underlay Rate to include preparing surfaces, forming joints, overlaps, mitres, angles, fillets, built-up edges, and laying to falls or cambers, cutting, notching, bending, and bedding. M131 [One layer of 50 mm x 50 mm x 22 SWG galvanised wire mesh fixed with tying wire as per Specification clause (.). [One layer of double sided aluminium foil sisalation] as per Specification clause (.). Insulation Rate to include preparing surfaces, forming joints, overlaps, mitres, angles, fillets, built-up edges, and laying to falls or cambers, cutting, notching, bending, and bedding. M141 [50 mm thick rock wool sheet size 1200 mm x 600 mm] as per Specification clause (.). [50 mm thick fiberglass insulation] as per Specification clause (.). m2 m2 m2 Description Unit Qty. Rate Amount (RM)

M121.2

m2

M122

m2

M123

m2

M132

m2

M142

m2

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM89 of BQM173

CLASS M Building Work


Item No. Code No. Roofing Ancillaries Rate to include forming holes, cutting, and making good for services, preparing surfaces, forming joints, mitres, angles, fillets, built-up edges, and laying to cambers or falls. M151.1 M151.2 M152 M153 [180 mm x 25 mm thick timber] eave. [180 mm x 25 mm thick] verge. [180 mm x 25 mm thick timber] fascia. [20 SWG thick galvanised mild steel flashing 300 mm girth]. [Timber] kerbs. [22 SWG galvanised mild steel] hood. Roof ventilators as per Specification clause (.). Soaker. Flat/Profiled Sheet Components Rate to include forming holes, cutting, and making good for services, preparing surfaces, forming joints, mitres, angles, fillets, built-up edges, and laying to cambers or falls. M161.1 [One layer of 20 mm thick asphalt to roof upstand] as per Specification clause (.) and as shown in Drawing No. (.). [One layer of 20 mm thick asphalt to twin kerb at expansion joint] as per Specification clause (.) and as shown in Drawing No. (.). [0.48 mm thick galvanised mild steel ridge capping 500 mm girth].
[0.48 mm thick galvanised mild steel hip capping to match profiled metal deck roof].

Description

Unit

Qty.

Rate

Amount (RM)

m m m m

M154 M155 M156 M157

m nr nr nr

M161.2

M162.1

M162.2

M163

[2 m x 1 m x 6 mm thick] polycarbonate skylight as per Specification clause (.). [2 m x 1 m x 6 mm thick corrugated transparent sheet] as per Specification clause (.). [6 mm thick corrugated] ventilator sheet.

nr

M164

nr

M165

nr

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM90 of BQM173

CLASS M Building Work


Item No. Code No. M166 M167 Description Roofing sheet with soaker flanges. Ridge ventilator. Tiles Components Rate to include forming holes, cutting, and making good for services, preparing surfaces, forming joints, mitres, angles, fillets, built-up edges, and laying to cambers or falls. M171 M172 Valley tiles (coloured) to match interlocking tiles. Mitred hip tiles (coloured) to match interlocking tiles. m m Unit nr nr Qty. Rate Amount (RM)

M173

Mitred vertical angle tiles (coloured) to match interlocking tiles. Ridge capping [500 mm girth]. Hip capping [500 mm girth]. Vertical angle tiles (coloured) to match interlocking tiles. Saddle (coloured) to match interlocking tiles. Glass tiles to match interlocking tiles. Gutters and Downpipes Rate for gutters and downpipes to include fixing and supply of fixing components.

M174.1 M174.2 M175

m m m

M176 M177

nr nr

M181 M182 M183 M184

[150 mm half round uPVC] rainwater gutters. [150 mm half round uPVC] elbow for gutters. [100 diameter uPVC] rain water down pipes. [100 diameter uPVC] elbow for rain water down pipes.

m nr m nr

M200

WATER PROOFING Rate for water proofing to include preparing surfaces, forming joints, overlaps, mitres, angles, fillets, built-up edges, and laying to falls or cambers. Asphalt

M211

[One layer of 20 mm thick asphalt] laid on sloping surface area.

m2

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM91 of BQM173

CLASS M Building Work


Item No. Code No. M212 Description [One layer of 20 mm thick asphalt] laid on horizontal surface area. [One layer of 20 mm thick asphalt] laid on vertical surface area. [One layer of 20 mm thick asphalt laid on 250 mm wide concrete gutter]. [One layer of 20 mm thick asphalt] laid on isolated group of surfaces not exceeding 1 m2. [One layer of 20 mm thick asphalt lining to 100 mm diameter vent pipe]. Bituminous M221 [One layer of 6 mm thick bituminous sheet] laid on sloping surface area. [One layer of 6 mm thick bituminous sheet] laid on horizontal surface area. [One layer of 6 mm thick bituminous] laid on vertical surface area. [One layer of 6 mm thick bituminous] laid on 300 mm wide concrete gutter. [One layer of 6 mm thick bituminous sheet] lay on isolated group of surfaces not exceeding 1 m2. m2 Unit m2 Qty. Rate Amount (RM)

M213

m2

M214

M215

nr

M216

nr

M222

m2

M223

m2

M224

M225

nr

M226

[One layer of 6 mm thick bituminous lining] to sides of concrete gutter. Sheet Metal

nr

M231

[One layer of 0.5 mm thick zinc sheet] laid on sloping timber boarding roof. [One layer of 0.5 mm thick zinc sheet] laid on horizontal timber boarding roof. [One layer of 0.5 mm thick zinc sheet] laid on vertical surface area. [One layer of 0.5 mm thick zinc sheet] laid on timber surfaces of width not exceeding 300 mm. [One layer of 0.5 mm thick zinc sheet] laid on isolated group of surfaces not exceeding 1 m2.

m2

M232

m2

M233

m2

M234

M235

nr

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM92 of BQM173

CLASS M Building Work


Item No. Code No. Description Waterproofing Sheeting M241 [One layer of 1 mm thick polyethylene sheet] laid on sloping surface area. [One layer of 1 mm thick polyethylene sheet] lay on horizontal surface area. [One layer of 1 mm thick polyethylene sheet] laid on vertical surface area. [One layer of 1 mm thick polyethylene sheet] laid on surface of width not exceeding 300 mm. [One layer of 1 mm thick polyethylene sheet] laid on isolated group of surfaces not exceeding 1 m2. [One layer of 1 mm thick polyethylene lining to concrete surfaces. Waterproof Coating M251 [One layer of 5 mm thick waterproofing membrane] as per Specification clause (.) laid on sloping surface area. [One layer of 5 mm thick waterproofing membrane] as per Specification clause (.) laid on horizontal surface area. [One layer of 5 mm thick waterproofing membrane] as per Specification clause (.) laid on vertical surface area. [One layer of 5 mm thick waterproofing membrane] as per Specification clause (.) laid on surface of width not exceeding 300 mm. [One layer of 5 mm thick waterproofing membrane] as per Specification clause (.) laid on isolated group of surfaces not exceeding 1 m2. [One layer of 5 mm thick waterproofing membrane] as per Specification clause (.) to concrete gutter. Rendering in Ordinary Cement Mortar M261 [One layer of 25 mm thick 1:3 cement sand mortar] laid on sloping surface area. [One layer of 25 mm thick 1:3 cement sand mortar] laid on horizontal surface area. [One layer of 25 mm thick 1:3 cement sand mortar] laid on vertical surface area. m2 m2 m2 Unit Qty. Rate Amount (RM)

M242

m2

M243

m2

M244

M245

nr

M246

nr

M252

m2

M253

m2

M254

M255

nr

M256

nr

M262

m2

M263

m2

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM93 of BQM173

CLASS M Building Work


Item No. Code No. M264 Description [One layer of 25 mm thick 1:3 cement sand mortar] bed at verge of roof] of width not exceeding 300 mm. Unit m Qty. Rate Amount (RM)

M265

[One layer of 25 mm thick 1:3 cement sand mortar] laid on isolated group of surfaces not exceeding 1 m2.

nr

M266

[One layer of 25 mm thick 1:3 cement sand mortar] at rainwater outlet. Rendering in Water Proof Cement Mortar

nr

M271

[One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid on sloping surface area. [One layer of 25 mm thick 1:3 cement sand mortar with waterprofing agent] as per Specification clause (.) laid on horizontal surface area. [One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid on vertical surface area. [One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid on surface of width not exceeding 300 mm. [One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid on isolated group of surfaces not exceeding 1 m2.

m2

M272

m2

M273

m2

M274

M275

nr

M276

[One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid rainwater outlet. Sprayed or Brushed Waterproofing

nr

M281

[One layer of 2 mm thick waterproofing material as per manufacturer's instruction] sprayed on sloping surface area. [One layer of 2 mm thick waterproofing material as per manufacturer's instruction] sprayed on horizontal surface area. [One layer of 2 mm thick waterproofing material as per manufacturer's instruction] sprayed on vertical surface area. [One layer of 2 mm thick waterproofing material as per manufacturer's instruction sprayed concrete gutter (measured separately) not exceeding 300 mm wide].

m2

M282

m2

M283

m2

M284

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM94 of BQM173

CLASS M Building Work


Item No. Code No. M285 Description [One layer of 2 mm thick waterproofing material as per manufacturer's instruction] sprayed on isolated group of surfaces not exceeding 1 m2. [One layer of 2 mm thick waterproofing material as per manufacturer's instruction sprayed at construction joint]. Unit nr Qty. Rate Amount (RM)

M286

nr

M300

WINDOWS AND DOORS Rate for windows and doors to include fixing, supply of fixing components, drilling or cutting of associated work, and all associated glazing work. Timber

M312

[Grade A] timber windows; [1200 mm x 1200 mm] fitted with standard sill and complete with 6 mm thick float glass louvres and 10 mm security bar as shown in Drawing No. (). [Grade A, 2100 mm x 900 mm] timber doors frames as shown in Drawing No. (.). Single leaf solid [Grade A] timber door type (.] as shown in Drawing No. (.). Double leaf solid [Grade A] timber door type (.] as shown in Drawing No. (.). [Two-hour rated fire resistant] double leaf solid timber door type (..) as per Specification clause (.).

nr

M313

nr

M314.1

nr

M314.2

nr

M315

nr

All ironmongery to include necessary fixing screws. M317.1 M317.2 Pair of stainless steel hinges; [75 mm x 50 mm]. Pair of stainless steel butt hinges; [100 mm x 75 mm]. nr nr

M317.3

["Mobel C3600-70-SS-Ent-HOM" ] cyclindrical knobset with stainless steel finish. ["St Guchi D264-70-SS-HOM"] half deadbolt. ["Dorma"] door closers, [140 mm x 22 mm]. Supply and fix anti-vermin netting on outside to window.

nr

M317.4 M317.5 M318

nr nr nr

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM95 of BQM173

CLASS M Building Work


Item No. Code No. Metal M321 Natural anodised windows sub-frames to suit [1200 mm x 1200 mm] side hung casement window as per Specification clause (..) and as shown the Drawing No. (). [1200 mm x 1200 mm] natural anodised aluminium side hung casement window complete with 6 mm thick clear float glass as shown in Drawing No. (). Natural anodised aluminium door frames to suit [2100 mm x 900 mm] door as shown the Drawing No. (). nr Description Unit Qty. Rate Amount (RM)

M322

nr

M323

nr

M324

Natural anodised aluminium door complete with 6 mm thick clear glass as showin in the drawings [Size: 900 mm x 2100 mm]. Natural anodised motorised aluminium roller shutter door complete with rollers, guide, pelmet, and locks; [4000 mm x 3500 mm] as shown in Drawing No. (..).

nr

M326

nr

Plastics M334 M337.1 M337.2 PVC doors; 32 mm thick; [2100 mm x 900 mm]. Pair of stainless steel hinges; [75 mm x 50 mm]. ["St Guchi D264-70-SS-HOM"] half deadbolt. nr nr nr

M400 M410.1 M410.2 M420

GLAZING 6 mm clear float glass, fixed with putty. 10 mm tinted glass, fixed with putty. [3000 x 2000 x 10 mm thick] clear float glass panel to be fixed with silicone. [3000 x 2000 x 10 mm thick] laminated glass panel to be fixed with silicone. Hermetically sealed units for double glazed panel. m2 m2 m2

M430

nr

M440

nr

M450

500 x 500 x 4 mm thick mirror with 4 nos. drilled holes, fixed with dome head mirror screws.

nr

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM96 of BQM173

CLASS M Building Work


Item No. Code No. M500 FINISHES Floor Finishes Rate for floor finishes to include fixing, supply of fixing components, drilling or cutting of associated work, preparing surfaces, forming joints, mitres, angles, fillets, built-up edges, and laying to chambers or falls. Description Unit Qty. Rate Amount (RM)

M511

Homogeneous tiles; [300 x 300 x 7.6 mm thick]. Rate to include cement mortar screed. [25 mm thick] cement and sand pavings to floor. [25 mm] thick granolithic finish to floor. [10 mm] thick wash aggregates finish to floor. [500 mm x 500 mm] square carpet tiles with knot density of 30 knots per cm2 as per Specification clause (.). [4 mm] thick vinyl sheet floor covering. Rate to include approved adhesive bedding component. Floor hardener with iron aggregate or 100% ferrous metallic surface applied at the rate of 4.0 kg/m2, finished with a layer of acrylic based curing compound.

m2

M512 M513 M514 M515

m2 m2 m2 m2

M516

m2

M517

m2

Skirting to Floor Rate for skirting to floor shall be deemed to include fixing, supply of fixing component, drilling or cutting of associated work, preparing surfaces, forming joints, mitres, angles, fillets, built-up edges, laying to cambers or falls and cement mortar screed.

M520

Homogenous tiles skirting [100 mm high x 7.6 mm] thick; rounded top edge. Wall Finishes Rate for wall finishes to include fixing, supply of fixing components, drilling or cutting of associated work, preparing surfaces, forming joints, mitres, angles, fillets, and built-up edges.

M531

[200 mm x 250 mm] ceramic wall tiles. Rate to include cement mortar screed. [20 mm] thick cement and sand plastering to wall. [20 mm] thick granolithic finish to wall.

m2

M532 M533

m2 m2

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM97 of BQM173

CLASS M Building Work


Item No. Code No. M534 M535 M536 Description [10 mm] thick wash aggregates finish to wall. Spray tiles. Prefabricated panel [200 x 200 x 25 mm thick] to be fixed at wall as decorative panel. Ceiling Finishes Rate for ceiling finishes to include any temporary staging required. M541 M542 Skim coat plaster to soffits and sides of beam. [20 mm] thick cement and sand rendering to soffit of roof slab. [600 x 1200 x 22 mm thick] fibreglass suspended ceilings. Rate to include aluminium tees and stainless steel hangers. [600 x 1200 x 3.2 mm thick] autoclaved cellulose fibre cement board suspended ceilings. Rate to include aluminium tees and stainless steel hangers. [10 mm thick] gypsum plasterboard ceilings. Rate to include [50 mm x 50 mm] pressure treated sawn timber at 600 mm centres as framework. [10 mm thick] gypsum plasterboard ceilings. Rate to include [50 x 25 x 1 mm thick] galvanised cold formed mild steel section at 600 mm centres as framework. m2 m2 Unit m2 m2 m2 Qty. Rate Amount (RM)

M543.1

m2

M543.2

m2

M543.3

m2

M543.4

m2

M544 M545

Cornices. [600 mm x 600 mm] access panel.

m nr

M600

FLOOR AND WALL SYSTEM Wall Partition Rate for wall partitions to include fixing, supply of fixing components, drilling or cutting of associated work, forming holes, cutting, and making good for services.

M611 M612

[100 mm] thick eco-solid wall system. [10 mm] thick full board

m2 m2

Page Total Carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM98 of BQM173

CLASS M Building Work


Item No. Code No. M613 Description [10 mm] thick half board with 6 mm thick fixed float glass [2000 mm x 1500 mm x 2200 mm] cubicle sets Raised access floor, [600 x 600 x 33 mm thick] high density processed timber panels sandwiched between two sheets of equal thickness plastic laminates. Rate to include all accessories such as cable outlets, skirting boards, PVC fascias, panel lifters, etc. Unit m2 Qty. Rate Amount (RM)

M614 M620

nr m2

M700

PLUMBING WORK Cold Water Plumbing System

M710

Cold water plumbing system as per Specification clause (.) and as shown schematically in Drawing No. (.). Rate to include all fittings, stop-cocks, and taps.

sum

Water Storage Tank M720 [3000 litres] HDPE water storage tank as per Specification clause (.). Rate to include supporting frame. Sanitary Plumbing System M730 Sanitary plumbing system as per Specification clause (.) and as shown schematically in Drawing No. (.). Rate to include all fittings. Sanitary Appliances and Fittings M740 Water closets; [Claytan 404 6-litre single flush side lever], bottom inlet overflow cistern with flapper valve internal fittings including medium duty plastic seat and cover. nr sum nr

Page Total carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM99 of BQM173

CLASS M Building Work


Item No. Code No. Septic Tanks Rate for septic tanks shall be deemed to include foundation, excavation, upholding sides of excavation, bedding, installation, backfilling, and all other related works where expressly required. M751 Septic tank for five population equivalent (PE) with a minimum of 24 hours of hydraulic retention time and a dual size aggregate down flow filter media as shown in Drawing No. (.). Pre-fabricated polyethylene septic tank for five population equivalent (PE) with incorporated filter chamber on the oulet section. Rate to include foundation, excavation, upholding sides of excavation, bedding, installation, backfilling, and all other related work where expressly required. nr Description Unit Qty. Rate Amount (RM)

M752

nr

Page Total carried to Summary of Class M

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM100 of BQM173

CLASS M Building Work


Item No. Code No. Description Summary of Class M: Building Work Page BQM1 Page BQM2 Page BQM3 Page BQM4 Page BQM5 Page BQM6 Page BQM7 Page BQM8 Page BQM9 Page BQM10 Page BQM11 Page BQM12 Page BQM13 Unit Qty. Rate Amount (RM)

Total of Class M carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class M: Building Work Page BQM101 of BQM173

CLASS N Painting Work


Item No. Code No. Description Painting shall be deemed to include preparation of surfaces, application of base primer/sealer required before painting and all necessary temporary staging. N100 OIL PAINT Metal Surfaces Rate for painting of metal shall be deemed to include painting the surfaces of connecting plates, brackets, rivets, bolts, nuts, and similar projections. Prepare and apply [two] coats of base primer and [two] coats of oil paint to: N111 Metal surfaces of [columns, beams, .] exceeding 300 mm girth. Metal surfaces of [columns, .] not exceeding 300 mm girth. Timber Rate for painting of timber shall be deemed to include painting the surfaces of recesses, projections, and fittings. Prepare and apply [one] coat of base primer and [two] coats of oil paint to: N121 Timber surfaces of [columns, beams, ..] exceeding 300 mm girth. Timber surfaces of [columns, ..] not exceeding 300 mm girth. Pipework Rate for painting of pipework shall be deemed to include painting the surfaces of flanges, valves, and other projecting fittings and hangers. Prepare and apply [one] coat of base primer and [two] coats of oil paint to: N161 Pipework surfaces of members exceeding 300 mm girth. m2 m2 m2 Unit Qty. Rate Amount (RM)

N112

N122

N162

Pipework surfaces of members not exceeding 300 mm girth.

Page Total carried to Summary of Class N

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN102 of BQN173

CLASS N Painting Work


Item No. Code No. N200 Description ALKYD GLOSS PAINT Metal Surfaces Rate for painting of metal shall be deemed to include painting the surfaces of connecting plates, brackets, rivets, bolts, nuts, and similar projections. Prepare and apply [one] coat of base primer and [two] coats of alkyd gloss paint to: N211 On metal surfaces of [columns, beams, .] exceeding 300 mm girth. On metal surfaces of [columns, .] not exceeding 300 mm girth. Timber Rate for painting of timber shall be deemed to include painting the surfaces of recesses, projections, and fittings. Prepare and apply [one coat ] of base primer and [two] coats of alkyd gloss paint to: N221 Timber surfaces of [colums, beams, ..] exceeding 300 mm girth. Timber surfaces of [colums, ..] not exceeding 300 mm girth. Pipework Rate for painting of pipeworks shall be deemed to include painting the surfaces of flanges, valves, and other projecting fittings and hangers. m2 m2 Unit Qty. Rate Amount (RM)

N212

N222

Prepare and apply [one] coat of base primer and [two] coats of alkyd gloss paint to: N261 Pipework surfaces of members exceeding 300 mm girth. m2

N262

Pipework surfaces of members not exceeding 300 mm girth.

Page Total carried to Summary of Class N

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN103 of BQN173

CLASS N Painting Work


Item No. Code No. N300 Description EMULSION PAINT OR ACRYLIC PAINT Smooth Surfaces Prepare and apply [one] coat of sealer and [two] coats of emulsion paint to: N331.1 Smooth plastered surfaces of internal [walls, columns, .] exceeding 300 mm girth. Smooth concrete surfaces of internal [walls, column,.] formed using Class F2 formwork exceeding 300 mm girth. Smooth concrete surfaces of internal [walls, column, .] formed using Class F3 formwork, exceeding 300 mm girth. Prepare and apply [one] coat of sealer and [two] coats of acrylic paint to: N331.4 Smooth plastered surfaces of external [walls, colums, .] exceeding 300 mm girth. Smooth concrete surfaces of external [walls, column, .] formed using Class F2 formwork, exceeding 300 mm girth. Smooth concrete surfaces of external [walls, column, .] formed using Class F3 formwork, exceeding 300 mm girth. Rough Surfaces Prepare and apply [one] coat of sealer and [two] coats of emulsion paint to: N341.1 Rough rendered surfaces of internal [ceiling soffit] exceeding 300 mm girth. Prepare and apply [one] coat of sealer and [two] coats of acrylic paint to: N341.2 Rough rendered surfaces of external [walls, column, ...] exceeding 300 mm girth. Rough concrete surfaces of external [walls, column, .] formed using Class F1 formwork, exceeding 300 mm girth. m2 m2 m2 m2 Unit Qty. Rate Amount (RM)

N331.2

m2

N331.3

m2

N331.5

m2

N331.6

m2

N341.3

m2

Page Total carried to Summary of Class N

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN104 of BQN173

CLASS N Painting Work


Item No. Code No. Masonry Prepare and apply [one] coat of sealer and [two] coats of acrylic paint to: N351 Masonry surfaces of members exceeding 300 mm girth. m2 Description Unit Qty. Rate Amount (RM)

N400

CEMENT PAINT Prepare and apply [one] coat of sealer and [two] coats of cement paint externally to: Rough Surfaces

N441

Concrete surfaces of members exceeding 300 mm girth.

m2

Masonry N451 Masonry surfaces of members exceeding 300 mm girth. m2

N500

EPOXY OR POLYURETHANE PAINT Metal Surfaces Rate for painting of metal shall be deemed to include painting the surfaces of connecting plates, brackets, rivets, bolts, nuts, and similar projections. Prepare and apply [one] coat of base primer and two coats of epoxy paint externally to:

N511.1

Metal surfaces other than pipework; surfaces of members exceeding 300 mm girth. Metal surfaces other than pipework; surfaces of members not exceeding 300 mm girth. Prepare and apply [one] coat of base primer and two coats of polyurethane paint externally to:

m2

N512.1

N511.2

Metal surfaces other than pipework; surfaces of members exceeding 300 mm girth. Metal surfaces other than pipework; surfaces of members not exceeding 300 mm girth.

m2

N512.2

Page Total carried to Summary of Class N

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN105 of BQN173

CLASS N Painting Work


Item No. Code No. Smooth Surfaces Prepare and apply [one] coat of base primer and two coats of epoxy paint externally to: N531.1 Smooth plastered surfaces of [walls, columns, .] exceeding 300 mm girth. Smooth concrete surfaces of [walls, columns, .] formed using Class F2 formwork exceeding 300 mm girth. Smooth concrete surfaces of [walls, columns, .] formed using Class F3 formwork exceeding 300 mm girth. Prepare and apply [one] coat of base primer and two coats of polyurethane paint externally to: N531.4 Smooth plastered surfaces of [walls, columns, .] exceeding 300 mm girth. Smooth concrete surfaces of [walls, columns, .] formed using Class F2 formwork exceeding 300 mm girth. Smooth concrete surfaces of [walls, columns, .] formed using Class F3 formwork exceeding 300 mm girth. Rough Surfaces Prepare and apply [one] coat of base primer and two coats of epoxy paint externally to: N541.1 Rough rendered surfaces of [walls, columns, ...] exceeding 300 mm girth. Rough concrete surfaces of [walls, columns, .] formed using Class F1 formwork, exceeding 300 mm girth. m2 m2 m2 Description Unit Qty. Rate Amount (RM)

N531.2

m2

N531.3

m2

N531.5

m2

N531.6

m2

N541.2

m2

Prepare and apply [one] coat of base primer and two coats of polyurethane paint externally to: N541.3 Rough rendered surfaces of [walls, columns, ...] exceeding 300 mm girth. Rough concrete surfaces of [walls, columns, .] formed using Class F1 formwork, exceeding 300 mm girth. m2

N541.4

m2

Page Total carried to Summary of Class N

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN106 of BQN173

CLASS N Painting Work


Item No. Code No. Pipework Rate for painting of pipework shall be deemed to include painting the surfaces of flanges, valves, and other projecting fittings and hangers. Prepare and apply [one] coat of base primer and two coats of epoxy paint externally to: N561.1 Pipework surfaces of members exceeding 300 mm girth. m2 Description Unit Qty. Rate Amount (RM)

N562.1

Pipework surfaces of members not exceeding 300 mm girth. Prepare and apply [one] coat of base primer and two coats of polyurethane paint externally to:

N561.2

Pipework surfaces of members exceeding 300 mm girth.

m2

N562.2

Pipework surfaces of members not exceeding 300 mm girth.

N600

BITUMINOUS OR COAL TAR PAINT Prepare and apply [two] coats of bituminous or coal tar paint to: Metal Surfaces Rate for painting of metal shall be deemed to include painting the surfaces of connecting plates, brackets, rivets, bolts, nuts, and similar projections.

N611

Metal surfaces other than pipework; surfaces of members exceeding 300 mm girth. Metal surfaces other than pipework; surfaces of members not exceeding 300 mm girth. Smooth Surfaces

m2

N612

N631.1

Smooth plastered surfaces of [walls, columns, .] exceeding 300 mm girth. Smooth concrete surfaces of class F2 exceeding 300 mm girth. Smooth concrete surfaces of [walls, columns, .] formed using Class F2 formwork, exceeding 300 mm girth.

m2

N631.2

m2

N631.3

m2

Page Total carried to Summary of Class N

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN107 of BQN173

CLASS N Painting Work


Item No. Code No. Rough Surfaces N641.1 Rough rendered surfaces of [walls, columns, ...] exceeding 300 mm girth. Rough concrete surfaces of [walls, columns, .] formed using Class F1 formwork exceeding 300 mm girth. m2 Description Unit Qty. Rate Amount (RM)

N641.2

m2

Pipework Rate for painting of pipeworks shall be deemed to include painting the surfaces of flanges, valves, other projecting fittings and hangers. N661 Pipework surfaces of members exceeding 300 mm girth. m2

N662

Pipework surfaces of members not exceeding 300 mm girth.

N700

CHLORINATED RUBBER PAINT Prepare and apply [one] coat of base primer and [two] coats of chlorinated rubber paint to: Metal Surface Rate for painting of metal shall be deemed to include painting the surfaces of connecting plates, brackets, rivets, bolts, nuts, and similar projections.

N711

Metal surfaces other than pipework; surfaces of members exceeding 300 mm girth. Metal surfaces other than pipework; surfaces of members not exceeding 300 mm girth. Smooth Surfaces

m2

N712

N731.1

Smooth plastered surfaces of [walls, columns, .] exceeding 300 mm girth. Smooth concrete surfaces of [walls, column, .] formed using Class F2 formwork exceeding 300 mm girth.

m2

N731.2

m2

N731.3

Smooth concrete surfaces of [walls, columns, .] formed using Class F3 formwork exceeding 300 mm girth.

m2

Page Total carried to Summary of Class N

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN108 of BQN173

CLASS N Painting Work


Item No. Code No. Rough Surfaces N741.1 Rough rendered surfaces of [walls, columns, ...] exceeding 300 mm girth. Rough concrete surfaces of [walls, columns, .] formed using Class F1 formwork exceeding 300 mm girth. m2 Description Unit Qty. Rate Amount (RM)

N741.2

m2

Pipework Rate for painting of pipework shall be deemed to include painting the surfaces of flanges, valves, and other projecting fittings and hangers. N761 Pipework surfaces of members exceeding 300 mm girth. m2

N762

Pipework surfaces of members not exceeding 300 mm girth.

Page Total carried to Summary of Class N

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN109 of BQN173

CLASS N Painting Work


Item No. Code No. Description Summary of Class N: Painting Work Page BQN1 Page BQN2 Page BQN3 Page BQN4 Page BQN5 Page BQN6 Page BQN7 Page BQN8 Unit Qty. Rate Amount (RM)

Total of Class N carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class N: Painting Work Page BQN110 of BQN173

CLASS O Pipework
Item No. Code No. O100 Description TRENCH EXCAVATION Trench excavation shall be deemed to include preparation of surfaces, excavation for bedding, multiple handling, disposal of surplus excavated material (including unsuitable material), upholding sides of excavation, allowance for working space, backfilling, removal of dead services, and reinstatement of original surface unless covered by separate items. Unit Qty. Rate Amount (RM)

100 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 100 mm DN pipe, depth not exceeding 1.5 m. In earth for 100 mm DN pipe, depth 1.5 2.0 m. In earth for 100 mm DN pipe, depth 2.0 2.5 m. In earth for 100 mm DN pipe, depth 2.5 3.0 m. 150 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 150 mm DN pipe, depth not exceeding 1.5 m. In earth for 150 mm DN pipe, depth 1.5 2 m. In earth for 150 mm DN pipe, depth 2.0 2.5 m. In earth for 150 mm DN pipe, depth 2.5 3.0 m. 200 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 200 mm DN pipe, depth not exceeding 1.5 m. In earth for 200 mm DN pipe, depth 1.5 2.0 m. In earth for 200 mm DN pipe, depth 2.0 2.5 m. In earth for 200 mm DN pipe, depth 2.5 3.0 m. m m m

O112 O113 O114

m m m

O112 O113 O114

m m m

O112 O113 O114

m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO111 of BQO173

CLASS O Pipework
Item No. Code No. Description 300 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 300 mm DN pipe, depth not exceeding 1.5 m. In earth for 300 mm DN pipe, depth 1.5 2 m. In earth for 300 mm DN pipe, depth 2.0 2.5 m. In earth for 300 mm DN pipe, depth 2.5 3.0 m. 400 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 400 mm DN pipe, depth not exceeding 1.5 m. In earth for 400 mm DN pipe, depth 1.5 2 m. In earth for 400 mm DN pipe, depth 2.0 2.5 m. In earth for 400 mm DN pipe, depth 2.5 3.0 m. 500 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 500 mm DN pipe, depth not exceeding 1.5 m. In earth for 500 mm DN pipe, depth 1.5 2 m. In earth for 500 mm DN pipe, depth 2.0 2.5 m. In earth for 500 mm DN pipe, depth 2.5 3.0 m. In earth for 500 mm DN pipe, depth 3.0 4.0 m. 600 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 600 mm DN pipe, depth not exceeding 1.5 m. In earth for 600 mm DN pipe, depth 1.5 2.0 m. In earth for 600 mm DN pipe, depth 2.0 2.5 m. m m m m Unit Qty. Rate Amount (RM)

O112 O113 O114

m m m

O112 O113 O114

m m m

O112 O113 O114 O115

m m m m

O112 O113

m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO112 of BQO173

CLASS O Pipework
Item No. Code No. O114 O115 Description In earth for 600 mm DN pipe, depth 2.5 3.0 m. In earth for 600 mm DN pipe, depth 3.0 4.0 m. 800 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 800 mm DN pipe, depth not exceeding 1.5 m. In earth for 800 mm DN pipe, depth 1.5 2.0 m. In earth for 800 mm DN pipe, depth 2.0 2.5 m. In earth for 800 mm DN pipe, depth 2.5 3.0 m. In earth for 800 mm DN pipe, depth 3.0 4.0 m. 1000 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1000 mm DN pipe, depth not exceeding 1.5 m. In earth for 1000 mm DN pipe, depth 1.5 2.0 m. In earth for 1000 mm DN pipe, depth 2.0 2.5 m. In earth for 1000 mm DN pipe, depth 2.5 3.0 m. In earth for 1000 mm DN pipe, depth 3.0 4.0 m. 1200 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1200 mm DN pipe, depth not exceeding 1.5 m In earth for 1200 mm DN pipe, depth 1.5 2 m In earth for 1200 mm DN pipe, depth 2.0 2.5 m In earth for 1200 mm DN pipe, depth 2.5 3.0 m In earth for 1200 mm DN pipe, depth 3.0 4.0 m m m m Unit m m Qty. Rate Amount (RM)

O112 O113 O114 O115

m m m m

O112 O113 O114 O115

m m m m

O112 O113 O114 O115

m m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO113 of BQO173

CLASS O Pipework
Item No. Code No. Description 1400 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1400 mm DN pipe, depth not exceeding 1.5 m. In earth for 1400 mm DN pipe, depth 1.5 2.0 m. In earth for 1400 mm DN pipe, depth 2.0. 2.5 m In earth for 1400 mm DN pipe, depth 2.5 3.0 m. In earth for 1400 mm DN pipe, depth 3.0 4.0 m. 1600 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1600 mm DN pipe, depth not exceeding 1.5 m. In earth for 1600 mm DN pipe, depth 1.5 2.0 m. In earth for 1600 mm DN pipe, depth 2.0 2.5 m. In earth for 1600 mm DN pipe, depth 2.5 3.0 m. In earth for 1600 mm DN pipe, depth 3.0 4.0 m. In earth for 1600 mm DN pipe, depth 4.0 5.0 m. 1800 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1800 mm DN pipe, depth not exceeding 1.5 m. In earth for 1800 mm DN pipe, depth 1.5 2.0 m. In earth for 1800 mm DN pipe, depth 2.0 2.5 m. In earth for 1800 mm DN pipe, depth 2.5 3.0 m. In earth for 1800 mm DN pipe, depth 3.0 4.0 m. In earth for 1800 mm DN pipe, depth 4.0 5.0 m. m m m Unit Qty. Rate Amount (RM)

O112 O113 O114 O115

m m m m

O112 O113 O114 O115 O116

m m m m m

O112 O113 O114 O115 O116

m m m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO114 of BQO173

CLASS O Pipework
Item No. Code No. Description 2000 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 2000 mm DN pipe, depth not exceeding 1.5 m. In earth for 2000 mm DN pipe, depth 1.5 2.0 m. In earth for 2000 mm DN pipe, depth 2.0 2.5 m. In earth for 2000 mm DN pipe, depth 2.5 3.0 m. In earth for 2000 mm DN pipe, depth 3.0 4.0 m. In earth for 2000 mm DN pipe, depth 4.0 5.0 m. 2200 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O112 O113 O114 O115 O116 In earth for 2200 mm DN pipe, depth 1.5 2.0 m. In earth for 2200 mm DN pipe, depth 2.0 2.5 m. In earth for 2200 mm DN pipe, depth 2.5 3.0 m. In earth for 2200 mm DN pipe, depth 3.0 4.0 m. In earth for 2200 mm DN pipe, depth 4.0 5.0 m. 2400 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O112 O113 O114 O115 O116 O117 In earth for 2400 mm DN pipe, depth 1.5 2.0 m. In earth for 2400 mm DN pipe, depth 2.0 2.5 m. In earth for 2400 mm DN pipe, depth 2.5 3.0 m. In earth for 2400 mm DN pipe, depth 3.0 4.0 m. In earth for 2400 mm DN pipe, depth 4.0 5.0 m. In earth for 2400 mm DN pipe, depth 5.0 6.0 m. 2600 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O112 In earth for 2600 mm DN pipe, depth 1.5 2.0 m. m m m m m m m m m m m m m Unit Qty. Rate Amount (RM)

O112 O113 O114 O115 O116

m m m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO115 of BQO173

CLASS O Pipework
Item No. Code No. O113 O114 O115 O116 O117 Description In earth for 2600 mm DN pipe, depth 2.0 2.5 m. In earth for 2600 mm DN pipe, depth 2.5 3.0 m. In earth for 2600 mm DN pipe, depth 3.0 4.0 m. In earth for 2600 mm DN pipe, depth 4.0 5.0 m. In earth for 2600 mm DN pipe, depth 5.0 6.0 m. 2800 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O112 O113 O114 O115 O116 O117 O118 In earth for 2800 mm DN pipe, depth 1.5 2.0 m. In earth for 2800 mm DN pipe, depth 2.0 2.5 m. In earth for 2800 mm DN pipe, depth 2.5 3.0 m. In earth for 2800 mm DN pipe, depth 3.0 4.0 m. In earth for 2800 mm DN pipe, depth 4.0 5.0 m. In earth for 2800 mm DN pipe, depth 5.0 6.0 m. In earth for 2800 mm DN pipe, depth exceeding 6.0 m. m m m m m m m Unit m m m m m Qty. Rate Amount (RM)

3000 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O113 O114 O115 O116 O117 O118 In earth for 3000 mm DN pipe, depth 2.0 2.5 m. In earth for 3000 mm DN pipe, depth 2.5 3.0 m. In earth for 3000 mm DN pipe, depth 3.0 4.0 m. In earth for 3000 mm DN pipe, depth 4.0 5.0 m. In earth for 3000 mm DN pipe, depth 5.0 6.0 m. In earth for 3000 mm DN pipe, depth exceeding 6.0 m. m m m m m m

Extras to Trench Excavation O121 O122 O123 Rock. Natural hard material. Artificial hard material. m3 m3 m3

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO116 of BQO173

CLASS O Pipework
Item No. Code No. O124 Description Roads and pavement, rate to include road cutting and reinstatement. Excavation for Manholes and Chambers O131.1 O131.2 O132.1 O132.2 In earth for [manholes]. In earth for [valve chambers]. Roads and pavement for [manholes]. Roads and pavement for [valve chambers], rate to include road cutting and reinstatement. Artificial hard material for [manholes]. Artificial hard material for [valve chambers]. Natural hard material for [manholes]. Natural hard material for [valve chambers]. In rock for [manholes]. In rock for [valve chambers]. m3 m3 m2 m2 Unit m2 Qty. Rate Amount (RM)

O133.1 O133.2 O134.1 O134.2 O135.1 O135.2

m3 m3 m3 m3 m3 m3

O200

BACKFILLING AND BEDDING MATERIALS Bedding

O211

[150 mm thick] sand bedding as per Specification clause (..) and as shown in Drawing No. (.). [150 mm thick] granular material as bedding as per Specification clause (..) and as shown in Drawing No. (.). [150 mm thick] Grade C20 mass concrete bedding. Rate to include formwork. [150 mm thick] Grade C25 reinforced concrete bedding with one layer of high tensile steel fabric mesh A193 (A7), 3.02 kg/m2. Rate to include formwork.

O212

O213

O214

Surround O221 [250 mm] sand surround as per Specification clause (..) and as shown in Drawing No. (.). [200 mm] granular material surround as per Specification clause (..) and as shown in Drawing No. (.). m

O222

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO117 of BQO173

CLASS O Pipework
Item No. Code No. O223 Description [150 mm] Crade C20 mass concrete surround. Rate to include formwork. [150 mm] Grade C25 reinforced concrete surround with one layer of high tensile steel fabric mesh A193 (A7), 3.02 kg/m2 all round. Rate to include formwork. Unit m Qty. Rate Amount (RM)

O224

Backfilling O231 Backfilling with sand to Specification clause (.). m3

O232

Backfilling with granular material to Specification clause (.).

m3

O300

PIPES Supply, laying or install. Rate to include all pipe cutting, wrapping, lining and lagging as required.

Sewerage Pipework Vitrified clay pipes, spigot socket ended including supply and making joints complete as per Specification clause (.) for the following: O311.1 [100 mm DN] in standard length of 1.25 m. Rate to include all fittings and valves. [150 mm DN] in standard length of 1.50 m. [200 mm DN] in standard length of 1.50 m. [225 mm DN] in standard length of 2.0 m. [300 mm DN] in standard length of 2.50 m. [400 mm DN] in standard length of 2.50 m. [600 mm DN] in standard length of 2.50 m. [1400 mm DN] in standard length of 2.0 m. [Centrifugally spun] reinforced concrete pipes, spigot socket ended to [MS 881] lined internally with [12 mm thick high alumina cement mortar] as per Specification clause (.). Rate to include supply and making joint complete for the following: O312.1 O312.2 450 mm DN in standard length of 3.0 m. 600 mm DN in standard length of 3.0 m. m m m

O311.2 O311.3 O311.4 O311.5 O311.6 O311.7 O311.8

m m m m m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO118 of BQO173

CLASS O Pipework
Item No. Code No. O312.3 O312.4 O312.5 O312.6 O312.7 Description 750 mm DN in standard length of 3.0 m. 900 mm DN in standard length of 3.0 m. 1200 mm DN in standard length of 3.0 m. 1500 mm DN in standard length of 3.0 m. 1800 mm DN in standard length of 3.0 m. High density polyethylene corrugated wall pipes to [DIN 16961]. Rate to include supply and making joints complete. O313.1 100 mm DN in standard length of 6 m. Rate to include all fittings and valves. 150 mm DN in standard length of 6 m. 200 mm DN in standard length of 6 m. 300 mm DN in standard length of 6 m. 450 mm DN in standard length of 6 m. 600 mm DN in standard length of 6 m. [Spigot socket ended] ductile iron pipes to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause (). Rate to include supply and making joints complete for the following: m Unit m m m m m Qty. Rate Amount (RM)

O313.2 O313.3 O313.4 O313.5 O313.6

m m m m m

O314.1

100 mm DN in standard length of 6 m. Rate to include all fittings and valves. 150 mm DN in standard length of 6 m. 200 mm DN in standard length of 6 m. 300 mm DN in standard length of 6 m. 400 mm DN in standard length of 6 m. 500 mm DN in standard length of 6 m. 600 mm DN in standard length of 6 m. 700 mm DN in standard length of 6 m.

O314.2 O314.3 O314.4 O314.5 O314.6 O314.7 O314.8

m m m m m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO119 of BQO173

CLASS O Pipework
Item No. Code No. Description [Mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] as per Specification clause (.) for the following: Unit Qty. Rate Amount (RM)

O315.1

100 mm DN [spigot socket ended] in standard length of 6 m. Rate to include all fittings, valves, and joints.

O315.2

150 mm DN [spigot socket ended] in standard length of 6 m. 200 mm DN [spigot socket ended] in standard length of 6 m. 300 mm DN [spigot socket ended] in standard length of 6 m. 400 mm DN [spigot socket ended] in standard length of 6 m. 450 mm DN [spigot socket ended] in standard length of 6 m. 500 mm DN [spigot socket ended] in standard length of 10 m. 600 mm DN [spigot socket ended] in standard length of 10 m. 800 mm DN [spigot socket ended] in standard length of 10 m.

O315.3

O315.4

O315.5

O315.6

O315.7

O315.8

O315.9

O315.10 1000 mm DN [spigot socket ended] in standard length of 10 m. O315.11 2200 mm DN [spigot socket ended] in standard length of 10 m. O315.12 2300 mm DN [spigot socket ended] in standard length of 7.5 m. O315.13 2600 mm DN [spigot socket ended] in standard length of 7.5 m. O315.14 3000 mm DN [spigot socket ended] in standard length of 7.5 m. Spigot socket ended glass reinforced plastic pipes, as per Specification clause (). Rate to include supply and making joints complete for the following:

O316.1

[300 mm DN, PN 16] with stiffnes of [10 kN/m2] in standard length of [12 m].

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO120 of BQO173

CLASS O Pipework
Item No. Code No. O316.2 Description [375 mm DN, PN 16] with stiffnes of [10 kN/m2] in standard length of [12 m]. [450 mm DN, PN 10] with stiffnes of [10 kN/m2] in standard length of [12 m]. [600 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [750 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [900 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [3000 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. High density polyethylene (HDPE) solid wall plain ended pipe to MS 1058 as per Specification clause (.) for the following: O317.1 [110 mm OD, PE 80, PN 16] in standard length of 12 m. m Unit m Qty. Rate Amount (RM)

O316.3

O316.4

O316.5

O316.6

O316.7

O317.2

[110 mm OD, PE 100, PN 20] in standard length of 12 m. [200 mm OD, PE 80, PN 16] in standard length of 12 m.

O317.3

O317.4

[450 mm OD, PE 80, PN 16] in standard length of 12 m.

O317.5

[710 mm OD, PE 80, PN 12.5] in standard length of 12 m. Acrylonitrile butadiene styrene (ABS) pipe plain ended to MS 1419 as per Specification clause () for the following:

O318.1

[140 mm OD, PN6] in standard length of 5.8 m. Rate to include all fittings, valves, and joints. [225 mm OD, PN 10] in standard length of 5.8 m. [250 mm OD, PN 12] in standard length of 5.8 m. [355 mm OD, PN 15] in standard length of 5.8 m. [400 mm OD, PN 15] in standard length of 5.8 m. [450 mm OD, PN 15] in standard length of 5.8 m.

O318.2 O318.3 O318.4 O318.5 O318.6

m m m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO121 of BQO173

CLASS O Pipework
Item No. Code No. O318.7 O318.8 O318.9 Description [560 mm OD, PN 15] in standard length of 5.8 m. [630 mm OD, PN 15] in standard length of 5.8 m. [710 mm OD, PN 10] in standard length of 5.8 m. Water Supply Pipework [Mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] as per Specification clause (.) for the following: Unit m m m Qty. Rate Amount (RM)

O321.1

100 mm DN [spigot socket ended] in standard length of 6 m. Rate to include all fittings, valves, and joints.

O321.2

150 mm DN [spigot socket ended] in standard length of 6 m. 200 mm DN [spigot socket ended] in standard length of 6 m. 300 mm DN [spigot socket ended] in standard length of 6 m. 400 mm DN [spigot socket ended] in standard length of 6 m. 450 mm DN [spigot socket ended] in standard length of 6 m. 500 mm DN [spigot socket ended] in standard length of 10 m. 600 mm DN [spigot socket ended] in standard length of 10 m. 800 mm DN [spigot socket ended] in standard length of 10 m.

O321.3

O321.4

O321.5

O321.6

O321.7

O321.8

O321.9

O321.10 1000 mm DN [spigot socket ended] in standard length of 10 m. O321.11 2200 mm DN [spigot socket ended] in standard length of 10 m. O321.12 2300 mm DN [spigot socket ended] in standard length of 7.5 m. O321.13 2600 mm DN [spigot socket ended] in standard length of 7.5 m. O321.14 3000 mm DN [spigot socket ended] in standard length of 7.5 m.

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO122 of BQO173

CLASS O Pipework
Item No. Code No. Description [Spigot socket ended] ductile iron pipes to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause (). Rate to include supply and making joints complete for the following: Unit Qty. Rate Amount (RM)

O322.1

100 mm DN in standard length of 6 m. Rate to include all fittings and valves. 150 mm DN in standard length of 6 m. 200 mm DN in standard length of 6 m. 300 mm DN in standard length of 6 m. 400 mm DN in standard length of 6 m. 500 mm DN in standard length of 6 m. 600 mm DN in standard length of 6 m. 700 mm DN in standard length of 6 m. High density polyethylene (HDPE) solid wall plain ended pipe to MS 1058 as per Specification clause (.) for the following:

O322.2 O322.3 O322.4 O322.5 O322.6 O322.7 O322.8

m m m m m m m

O323.1

[110 mm OD, PE 80, PN 16] in standard length of 12 m.

O323.2

[110 mm OD, PE 100, PN 20] in standard length of 12 m. [200 mm OD, PE 80, PN 16] in standard length of 12 m.

O323.3

O323.4

[450 mm OD, PE 80, PN 16] in standard length of 12 m.

O323.5

[710 mm OD, PE 80, PN 12.5] in standard length of 12 m. Unplasticised polyvinyl chloride (uPVC) pipes to MS 628, with bell mouth joints as per Specification clause (.). Rate to include supply and making joints complete for the following:

O324.1

[100 mm DN, PN 15] in standard length of 6 m. Rate to include fittings and valves. [155 mm DN, PN 15] in standard length of 6 m. [200 mm DN, PN 15] in standard length of 6 m. [250 mm DN, PN 15] in standard length of 6 m.

O324.2 O324.3 O324.4

m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO123 of BQO173

CLASS O Pipework
Item No. Code No. O324.5 Description [300 mm DN, PN 15] in standard length of 6 m. Spigot socket ended glass reinforced plastic pipes, as per Specification clause (). Rate to include supply and making joints complete for the following: Unit m Qty. Rate Amount (RM)

O325.1

[300 mm DN, PN 16] with stiffnes of [10 kN/m2] in standard length of [12 m]. [375 mm DN, PN 16] with stiffnes of [10 kN/m2] in standard length of [12 m]. [450 mm DN, PN 10] with stiffnes of [10 kN/m2] in standard length of [12 m]. [600 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [750 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [900 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [3000 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [300 mm DN] plain ended stainless steel pipes as per Specification clause (.). Acrylonitrile butadiene styrene (ABS) pipe plain ended to MS 1419 as per Specification clause () for the following:

O325.2

O325.3

O325.4

O325.5

O325.6

O325.7

O326

O327.1

[88.9 mm OD, PN6] in standard length of 5.8 m. Rate to include all fittings, valves, and joints. [225 mm OD, PN 10] in standard length of 5.8 m. [250 mm OD, PN 12] in standard length of 5.8 m. [355 mm OD, PN 15] in standard length of 5.8 m. [400 mm OD, PN 15] in standard length of 5.8 m. [450 mm OD, PN 15] in standard length of 5.8 m. [560 mm OD, PN 15] in standard length of 5.8 m. [630 mm OD, PN 15] in standard length of 5.8 m. [710 mm OD, PN 10] in standard length of 5.8 m.

O327.2 O327.3 O327.4 O327.5 O327.6 O327.7 O327.8 O327.9

m m m m m m m m

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO124 of BQO173

CLASS O Pipework
Item No. Code No. Description Multilayer polyvinyl chloride(MPVC) pipes to JIS K6742 with bell moouth joints as per Specification clause (.). Rate to include supply and making joints complete for the following: O328.1 [100 mm DN, PN 15] in standard length of 6 m. Rate to include fittings and valves. [155 mm DN, PN 15] in standard length of 6 m. [200 mm DN, PN 15] in standard length of 6 m. [250 mm DN, PN 15] in standard length of 6 m. [300 mm DN, PN 15] in standard length of 6 m. Other Pipework [Spigot socket ended] ductile iron pipes to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause (). Rate to include supply and making joints complete for the following: m Unit Qty. Rate Amount (RM)

O328.2 O328.3 O328.4 O328.5

m m m m

O331.1

100 mm DN in standard length of 6 m. Rate to include all fittings and valves. 150 mm DN in standard length of 6 m. 200 mm DN in standard length of 6 m. 300 mm DN in standard length of 6 m. 400 mm DN in standard length of 6 m. 500 mm DN in standard length of 6 m. 600 mm DN in standard length of 6 m. 700 mm DN in standard length of 6 m. [Mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] as per Specification clause (.) for the following:

O331.2 O331.3 O331.4 O331.5 O331.6 O331.7 O331.8

m m m m m m m

O332.1

100 mm DN [spigot socket ended] in standard length of 6 m. Rate to include all fittings, valves, and joints.

O332.2

150 mm DN [spigot socket ended] in standard length of 6 m. 200 mm DN [spigot socket ended] in standard length of 6 m.

O332.3

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO125 of BQO173

CLASS O Pipework
Item No. Code No. O332.4 Description 300 mm DN [spigot socket ended] in standard length of 6 m. 400 mm DN [spigot socket ended] in standard length of 6 m. 450 mm DN [spigot socket ended] in standard length of 6 m. 500 mm DN [spigot socket ended] in standard length of 10 m. 600 mm DN [spigot socket ended] in standard length of 10 m. Unplasticised polyvinyl chloride (uPVC) pipes to MS 628, with bell moouth joints as per Specification clause (.). Rate to include supply and making joints complete for the following: O333.1 [100 mm DN, PN 15] in standard length of 6 m. Rate to include fittings and valves. [155 mm DN, PN 15] in standard length of 6 m. [200 mm DN, PN 15] in standard length of 6 m. [250 mm DN, PN 15] in standard length of 6 m. [300 mm DN, PN 15] in standard length of 6 m. m Unit m Qty. Rate Amount (RM)

O332.5

O332.6

O332.7

O332.8

O333.2 O333.3 O333.4 O333.5

m m m m

High density polyethylene (HDPE) solid wall plain ended pipe to MS 1058 as per Specification clause (.) for the following: O334.1 [110 mm OD, PE 80, PN 16] in standard length of 12 m. m

O334.2

[110 mm OD, PE 100, PN 20] in standard length of 12 m. [200 mm OD, PE 80, PN 16] in standard length of 12 m.

O334.3

O334.4

[450 mm OD, PE 80, PN 16] in standard length of 12 m.

O334.5

[710 mm OD, PE 80, PN 12.5] in standard length of 12 m. Vitrified clay pipes, spigot socket ended including supply and making joints complete as per Specification clause (.) for the following:

O335.1

[100 mm DN] in standard length of 1.25 m. Rate to include all fittings and valves.

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO126 of BQO173

CLASS O Pipework
Item No. Code No. O335.2 O335.3 O335.4 O335.5 O335.6 O335.7 O335.8 Description [150 mm DN] in standard length of 1.50 m. [200 mm DN] in standard length of 1.50 m. [225 mm DN] in standard length of 2.0 m. [300 mm DN] in standard length of 2.50 m. [400 mm DN] in standard length of 2.50 m. [600 mm DN] in standard length of 2.50 m. [1400 mm DN] in standard length of 2.0 m. Reinforced concrete pipes to [MS 881] butt jointed with collars as per Specification clause (.). Rate to include supply and making joint complete for the following: O336.1 [450 mm DN, Class X] in standard length of 3.0 m. m Unit m m m m m m m Qty. Rate Amount (RM)

O336.2 O336.3 O336.4 O336.5

[600 mm DN, Class Y] in standard length of 3.0 m. [750 mm DN, Class Z] in standard length of 3.0 m. [900 mm DN, Class X] in standard length of 3.0 m. [1200 mm DN, Class Y] in standard length of 3.0 m.

m m m m

O336.6

[1500 mm DN, Class Z] in standard length of 3.0 m.

O336.7

[1800 mm DN, Class Z] in standard length of 3.0 m.

O337

[300 mm DN] plain ended stainless steel pipes as per Specification clause (.). Exposed Pipework

O341

[300 mm DN] plain ended mild steel pipes to BS 534, concrete lined internally and painted externally with primer and finishing coat as per Specification clause () for stream-overcrossing at Sg. () as shown in Drawing No. (). [300 mm DN] plain ended stainless steel pipes as per Specification clause () for elevated pipe as shown in Drawing No. (). [300 mm DN double flanged] ductile iron pipes to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause () for drain overcrossing as shown in Drawing No. (...).

O342

O343

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO127 of BQO173

CLASS O Pipework
Item No. Code No. O400 Description FITTINGS, VALVES, AND JOINTS Straight Specials Item for straight specials shall be deemed to include cutting where applicable. [Mild] steel pipes and fittings, shall be to Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] as per Specification clause (.): Unit Qty. Rate Amount (RM)

Ductile iron pipes and fittings shall be to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause (). O411 [300 mm DN] mild steel plain ended pipes, [2000 mm] long. [300 mm DN] plain and flanged ended mild steel pipes, [2000 mm] long. Flanges shall be [PN 16 to BS EN 1092-1]. [300 mm DN] flanged ended mild steel pipes, [2000 mm] long. Flanges shall be [PN 16 to BS EN 1092-1]. nr

O412

nr

O413.1

nr

O413.2

[300 mm DN] flanged ended ductile iron pipes, [2000 mm] long. Flanges shall be [PN 16 to BS EN 1092-1].

nr

O414

[300 mm DN] plain ended mild steel pipe, [2000 mm] long with puddle flange at [1000 mm] from one end. Details of puddle flange shall be as shown in Drawing No. (). [300 mm DN] plain and flanged ended mild steel pipe, [2000 mm] long with puddle flange at [1000 mm] from flange end. Flange shall be [PN 16 to BS EN 1092-1] and details of puddle flange shall be as shown in Drawing No. (). [300 mm DN] flanged ended mild steel pipe, [2000 mm] long with puddle flange at [1000 mm] from one end. Flanges shall be [PN 16 to BS EN 1092-1] and details of puddle flange shall be as shown in Drawing No. ().

nr

O415

nr

O416.1

nr

O416.2

[300 mm DN] flanged ended ductile iron pipe, [2000 mm] long with puddle flange at [1000 mm] from one end. Flanges shall be [PN 16 to BS EN 1092-1] and details of puddle flange shall be as shown in Drawing No. ().

nr

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO128 of BQO173

CLASS O Pipework
Item No. Code No. Fittings O421.1 [300 mm DN, 90-degree plain ended mild steel gusseted] horizontal bend. [300 mm DN, 45-degree plain ended mild steel gusseted] horizontal bend. [300 mm DN, 45-degree plain ended mild steel gusseted] vertical bend. [300 mm DN, 45-degree plain ended mild steel gusseted] vertical bend painted externally with primer and finishing coat as per Specification clause (). nr Description Unit Qty. Rate Amount (RM)

O421.2

nr

O421.3

nr

O421.4

nr

O421.5

[300 mm DN, 90-degree double socket ended ductile iron] horizontal bend. [300 mm DN, 90-degree double flanged ductile iron short radius] horizontal bend. [300 mm DN, 45-degree double flanged ductile iron short radius] vertical bend. [300 mm DN, 90-degree double flanged ductile iron long radius] horizontal bend. [300 mm DN, 90-degree plain ended HDPE gusseted] horizontal bend. [300 mm DN] vitrified clay bellmouth Y-junction [300 mm DN] vitrified clay bellmouth tee. [300 mm DN] plain ended barrel with [100 mm DN] flanged branch concentric mild steel tee for air-valve as shown in Drawing No. (). [300 mm DN] plain ended barrel with [100 mm DN] flanged branch level invert mild steel tee for washout as shown in Drawing No. (). [600 mm DN] plain ended barrel with [400 mm DN] flanged branch concentric mild steel wye as shown in Drawing No. (). [600 mm DN] to [400 mm DN] plain ended mild steel concentric taper as shown in Drawing No. ().

nr

O421.6

nr

O421.7

nr

O421.8

nr

O421.9

nr

O422.1 O422.2 O423.1

nr nr nr

O423.2

nr

O424

nr

O425.1

nr

O425.2

[600 mm DN] to [400 mm DN] plain ended mild steel level invert taper as shown in Drawing No. ().

nr

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO129 of BQO173

CLASS O Pipework
Item No. Code No. O426 Description [600 mm DN] ductile iron flanged bell mouth. Flanges shall be [PN 6 to BS EN 1092-1]. [600 mm DN] ductile iron blank flanges. Flanges shall be [PN 10 to BS EN 1092-1]. [600 mm DN] mild steel blank flanges. Flanges shall be [PN 10 to BS EN 1092-1]. [300 mm DN] double flanged ductile iron duckfoot bend. Valves O431.1 [100 mm DN] single orifice air valves. Rate to include isolating butterfly valve. [150 mm DN] double orifice air valves. Rate to include isolating butterfly valve. [600 mm DN] double flanged butterfly valves, PN 10 manually operated as per Specification clause (). Rate to include reduction gears. [600 mm DN] double flanged butterfly valves, PN 16 complete with electric actuators as per Specification clause (). Rate to include reduction gears. nr Unit nr Qty. Rate Amount (RM)

O427.1

nr

O427.2

nr

O428

nr

O431.2

nr

O432.1

nr

O432.2

nr

O433

[300 mm DN] double flanged gate valves, PN 10 manually operated as per Specification clause (). Rate to include reduction gears. [600 mm DN] full bore altitude valves as per Specification clause (). [600 mm DN] pressure reducing valves as per Specification clause (). [600 mm DN] pressure sustaining valves as per Specification clause (). [300 mm DN] double flanged non return valves, nonslam type, PN 16 as per Specification clause ().

nr

O434

nr

O435

nr

O436

nr

O437

nr

O438

[300 mm DN] double flanged plug, PN 16 as per Specification clause (). Valves

nr

O441

[600 mm square] stainless steel penstocks as per Specification clause (). [300 mm DN] cast iron flap gates as per Specification clause (.).

nr

O442

nr

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO130 of BQO173

CLASS O Pipework
Item No. Code No. O443 O444 Description [200 mm DN] flat seat valves. Pillar hydrants with double outlets as per Specification clause (.). [150 mm DN] stainless steel strainer. Joints Items for joints shall include supply of all jointing materials, bolts, nuts, washers, gaskets, making good of joints both internally and externally. O451.1 O451.2 [600 mm DN] mild steel welded collar joints. [800 mm DN] mild steel welded collar joints. Rate to include welding to internal of pipe and air testing of joints. HDPE welded collar by electrofusion for [180 mm OD, PE 80, PN 16] pipe. [600 mm DN] mild steel welded slip joints. [800 mm DN] mild steel welded slip joints. Rate to include welding to internal of pipe and air testing of joints. Butt fusion welded joints for [180 mm OD, PE 80, PN 16] pipe. [300 mm DN] mechanical coupling joints. [300 mm DN] mechanical stepped coupling joints. nr nr Unit nr nr Qty. Rate Amount (RM)

O445

nr

O451.3

nr

O452.1 O452.2

nr nr

O453

nr

O454.1 O454.2

nr nr

O455

[300 mm DN] flange adaptor joints as shown in Drawing No. (.). [600 mm DN] expansion joints as shown in Drawing No. (.). Push-on collar joints for 300 mm DN HDPE profiled wall pipes. Push-on slip joints for [900 mm DN] centrifugally spun reinforced concrete pipes. [200 mm DN] flow meter/bulk meter of the "Kent Helix" type. [200 mm DN] electromagnetic flow meter. [200 mm DN] ultrasonic flow meter.

nr

O456

nr

O457

nr

O458

nr

O460.1

nr

O460.2 O460.3

nr nr

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO131 of BQO173

CLASS O Pipework
Item No. Code No. O500 Description BELOW GROUND CROSSINGS Rate for below ground crossings shall include reinstatement work. River, Stream, Culvert, or Canal O511 River, stream, culvert, or canal width, 1 3 m for [300 mm DN] pipe. River, stream, culvert, or canal width, 3 10 m for [300 mm DN] pipe. River, stream, culvert, or canal width exceeding 10 m for [300 mm DN] pipe. Fence O541 Crosssing under fence for [300 mm DN] pipe. Sewer or Drain O551.1 Crosssing over existing [400 mm DN] sewer pipe for [300 mm DN] pipe. Rate to include concrete surround to existing existing sewer pipe. Crosssing under 600 mm block drain for [300 mm DN] pipe. Rate to include concrete surround to pipe. nr nr nr Unit Qty. Rate Amount (RM)

O521

nr

O531

nr

O551.2

nr

Wall O561 Crossing under brickwall fence for [300 mm DN] pipe. Rate to include concrete surround to pipe. Other Stated Underground Services O571 Crossing under existing 600 mm DN water mains for [300 mm DN] pipe. [Rate to include sand surround to both existing and new pipe]. nr nr

O600

SPECIAL PIPE LAYING METHODS Item for special pipe laying methods is deemed to include mobilisation and demobilisation. Pipe Jacking Road crossing for [600 mm DN] water pipe at Jalan [Besi} by pipe jacking as shown in Drawing No. (.).

O611

Design, excavate, construct, and maintain jacking pits including sheet piling, bracing, waling, concrete thrust wall, anchor foundation, guide rails, and backfilling, etc.

nr

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO132 of BQO173

CLASS O Pipework
Item No. Code No. O612 Description Design, excavate, construct, and maintain receiving pits including sheet piling, bracing, waling, concrete thrust wall, anchor foundation, guide rails, and backfilling, etc. Unit nr Qty. Rate Amount (RM)

O613

Supply, haul, handle, jack in, and install of 1200 mm DN Reinforced Concrete jacking pipe class 'Z'. Rate to include mild steel joint and excavation within pipe sleeve and other materials for complete installation.

O615

Install [600 mm DN mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] within pipe sleeve. Pressure grouting for annulus space in between [600 mm DN steel pipe] and pipe sleeve as per Specification clause (.). Microtunneling Road crossing for [600 mm DN] water pipe at Jalan [Besi} by microtunneling as shown in Drawing No. (.).

O616

m3

O621

Design, excavate, construct, and maintain jacking pits including sheet piling, bracing, waling, concrete thrust wall, anchor foundation, guide rails, and backfilling, etc. Design, excavate, construct, and maintain receiving pits including sheet piling, bracing, waling, concrete thrust wall, anchor foundation, guide rails, and backfilling, etc.

nr

O622

nr

O624

Supply, haul, handle, jack in, and install of 1200 mm DN concrete cladded steel composite pipe. Rate to include mild steel joint and excavation within pipe sleeve and other materials for complete installation.

O625

Install [600 mm DN mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] within pipe sleeve. [450 mm OD, PE 80, PN 16] butt fusion welded HDPE pipe using the horizontal directional drilling method.

O630

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO133 of BQO173

CLASS O Pipework
Item No. Code No. Description Submarine Pipelaying O641 Bathymetric survey as per Specification clause (.) of approximately [25 km] by [500 m] at 25 meters line interval with cross ties at [250 m]. Sub-sea geophysical survey as per Specification clause (.) of approximately [25 km] by [500 m] at 50 meters line interval with cross ties at [500 m]. Rate to include report by a geophysicist. Mobilisation of all necessary plant and equipment, marine vessels, [winches], [lar-barge], etc to suit the method statement adopted for laying the sub-sea pipelines. Rate to include demobilisation upon completion of work. Provision of winch equipment to suit method statement adopted for laying the sub-sea pipelines. m Unit Qty. Rate Amount (RM)

O642

O643

sum

O644

sum

O645

Trenching across Sg. (.) for [300 mm DN] pipe as shown in Drawing No. (.) with cover of at least 1.5 m cover at the banks and 0.3 m at the deepest section of the river. [60 mm thick] concrete cladding to [300 mm DN] steel pipe. Lay [300 mm DN] API grade steel pipes by float and sink method. Lay [300 mm DN] API grade steel pipes by bottom pull method. Lay [500 mm DN] mild steel pipes by lay barge method.

O646

O651

O652

O653

O654

Carry out tie-in of riser pipe to land pipe as detailed in approved methd statement. Swabbing and gauging of completed pipeline until pipeline is clean and confirm integrity of pipeline to Specification clause (.). Inspection of sub-sea pipeline by divers. Pipe Bursting

sum

O655

O656

sum

O661

[450 mm OD, PE 80, PN 16] butt fusion welded HDPE pipe using the pipe bursting method.

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO134 of BQO173

CLASS O Pipework
Item No. Code No. Slip Lining O671 Slip lining to existing 450 mm DN asbestos cement pipe using [450 mm OD, PE 80, PN 16] butt fusion welded HDPE pipe m Description Unit Qty. Rate Amount (RM)

O700

REHABILITATION OF EXISTING PIPEWORK SYSTEM Preparation of Existing Pipework for Rehabilitation

For 900 mm DN sewer from Manhole A to Manhole B.

O711

Cleaning, jetting, and removal of carbonaceous formation intrusions. Rate to include making good existing sewer pipe. Local internal repairs. Pipe joint sealing, with cement mortar. Pipe joint sealing, with epoxy mortar under pressure.

O712 O713.1 O713.2

m2 m m

O714 O715

External grouting using 4 nos. of holes. External grouting by injection of cement grout as per Specification clause (..). Rehabilitation of Existing Pipework

nr m3

O721

Cured in place lining with resin impregnated felt tube to finished internal daimeter of [600 mm]. In situ jointed pipe lining using glass reinforced plastic as per Specification clause (.) to finished internal diameter of 900 mm. Circular segmental lining using glass reinforced plastic as per Specification clause (.), with miniumum finished internal diameter of 900 mm. Circular segmental lining using 15 mm thick glass reinforced concrete as per Specification clause (.), with miniumum finished internal diameter of 900 mm.

O722

O723.1

O723.2

O724 O725

Stated proprietory lining, diameter stated. [50 mm thick] gunite coating to [900 mm DN] sewer pipe. Cement grout as per Specification clause (..) as annulus grouting to [900 mm DN} pipe.

m m2

O726

m3

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO135 of BQO173

CLASS O Pipework
Item No. Code No. Description Rehabilitation of Existing Manholes O731 Abandonment of existing manholes as per Drawing No. (.) for depth of [2.5 m] including removing cover slab, breaking back shaft sealing off the ends of existing pipework and backfilling with sand. nr Unit Qty. Rate Amount (RM)

O732

Modification of existing manholes for manhole as shown in Drawing No. (..) including work to benching and inverts, breaking out, re-haunching, and dealing with flows.

nr

O800

MISCELLANEOUS WORK Sewer Manholes

O811

Brick manholes Type [A] with heavy duty cover and frame for [2.5 m depth] as shown in Drawing No. (.). Rate to include blinding, reinforced concrete base and top slabs. Reinforced concrete manholes with heavy duty cover and frame Type [1] as shown in Drawing No. (..).

nr

O812

nr

O813

Reinforced concrete manholes with backdrops, heavy duty cover, and frame Type [1] as shown in Drawing No. (..). Rate to include the pipework and associated fittings comprising the backdrops.

nr

O814

Precast concrete manholes Type [2] with heavy duty cover and frame as shown in Drawing No. (..).

nr

O815

Precast concrete manholes with backdrops Type [3] with heavy duty cover and frame as shown in Drawing No. (.). Rate to include the pipework and associated fittings comprising the backdrops.

nr

Testing and Inspection Rate for testing and inspection shall be deemed to include provision, and removal of all equipment, and ancillaries required for testing. O821 Testing of [300 mm DN vitrified clay pipe] gravity sewer. Rate to include testing by infiltration and provision of all water required for testing. m

O822

Testing of [300 mm DN vitrified clay pipe] vacuum sewer. Rate to include all equipment required.

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO136 of BQO173

CLASS O Pipework
Item No. Code No. O823 Description Pressure and leakage testing for [600 mm DN mild steel pipe] from Jalan [Pipe] to Jalan [Besi]. Rate to include provision of all water required for testing. Flushing and sterilisingf or [600 mm DN mild steel pipe] from Jalan [Pipe] to Jalan [Besi]. Rate to include chemicals and provision of water. Close circuit television inspection survey for [300 mm DN] sewer pipe from Manhole [A] to Manhole [B] as shown in Drawing No. (..). Radiographic test for 3% of all welds for mild steel pipeline. Holiday detector test, rate to include provision of equipment, testing, and maintenance. Ultrasonic test, rate to include provision of equipment, testing, and maintenance. Temporary Diversion O831 Temporary diversion of existing utilities. Rate to include coordination with relevant authorities and provision of and removal of all equipment and ancillaries required, including pumping over. Temporary diversion of sewage flows for [300 mm DN] pipe from Manhole [A] to Manhole [B} as shown in Drawing No. (.......). Rate to include coordination with relevant authorities and provision of and removal of all equipment and ancillaries required including pumping over. Connections to Existing Sewer System Item for connections to existing sewer system shall be deemed to include coordination with authorities, payment of fees, isolations for shutdown of flows, and dewatering. O841 At existing [brick] manhole, size [1.5 m x 1.5 m x 2.0 m deep of [600 mm DN] vitrified clay sewer pipe. nr sum Unit m Qty. Rate Amount (RM)

O824

O825

O826

nr

O827

sum

O828

sum

O832

sum

O842

At Y-junction of existing [600 mm DN] vitrified clay sewer pipe. With saddle connection to existing [600 mm DN] vitrified clay sewer pipe.

nr

O843

nr

Page Total carried to Summary of Class O

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO137 of BQO173

CLASS O Pipework
Item No. Code No. O844 Description New manhole at existing [600 mm DN] vitrified clay sewer pipe. Rate to include breaking away of existing sewer pipe as required and all pipework and metalwork within the manhole. Connection to Existing Water Mains O851 Hot tapping connection work to existing [900 mm DN steel pipeline] as shown in Drawing No. (..). Rate to injclude tapping tees, isolating valve, and testing. nr Unit nr Qty. Rate Amount (RM)

O852

Shut down connection work to existing [900 mm DN steel pipeline] as shown in Drawing No. (..). Rate to include coordination with authorities, payment of fees, isolations for shutdown of flows, and dewatering.

nr

Pipework Ancillaries O861 Marker posts for air valve, washout, and isolating valves as shown in Drawing No. (.). Rate to include supply, installation, and painting. Ring girder for [1000 mm DN] mild steel pipe stream crossing at Sg. () as shown in Drawing No. (.). Rate to include supply, installation, and painting. nr

O862

nr

O863

Pipe straps for [600 mm DN] exposed pipelines. Rate to include supply, installation, and painting. Spike guard for [600 mm DN] mild steel pipe stream crossing at Sg. () as shown in Drawing No. (.). Rate to include supply, installation, and painting.

nr

O864

nr

O870

Reinstatement of landscaping from Ch (.) to Ch (.) for [600 mm DN] pipelaying work along Jalan [Besi].

sum

O880

Water sampling station as per Specification clause (). Rate to include connections to mains.

nr

Page Total carried to Summary of Class O Class O: Pipework Page BQO138 of BQO173

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

CLASS O Pipework
Item No. Code No. Description Summary of Class O: Pipework Page BQO1 Page BQO2 Page BQO3 Page BQO4 Page BQO5 Page BQO6 Page BQO7 Page BQO8 Page BQO9 Page BQO10 Page BQO11 Page BQO12 Page BQO13 Page BQO14 Page BQO15 Page BQO16 Page BQO17 Page BQO18 Page BQO19 Page BQO20 Page BQO21 Page BQO22 Page BQO23 Page BQO24 Page BQO25 Page BQO26 Page BQO27 Page BQO28 Total of Class O carried to Grand Summary Unit Qty. Rate Amount (RM)

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class O: Pipework Page BQO139 of BQO173

CLASS P Drainage Work


Item No. Code No. P100 Description DRAIN EXCAVATION Drain excavation shall be deemed to include preparation of surfaces, double handling, disposal of surplus excavated material, upholding sides of excavation, allowance for joints, backfilling, and removal of dead services and reinstatement of Original Surface unless covered by separate items. Unit Qty. Rate Amount (RM)

[600 mm] precast concrete block drain for Road [A] as shown in Drawing No. (.). P111.1 In earth for [600 mm precast concrete block drain], depth not exceeding 1.5 m. In earth for [600 mm precast pipe culvert], depth not exceeding 1.5 m. In earth for [600 mm precast concrete block drain], depth 1.5 2.0 m. In earth for [900 mm precast pipe culvert], depth 1.5 2.0 m. In earth for [600 mm precast concrete block drain], depth 2.0 2.5 m. In earth for [1200 mm precast pipe culvert], depth 2.0 2.5 m. In earth for [600 mm precast concrete block drain], depth 2.5 3.0 m. In earth for [1200 mm precast pipe culvert], depth 2.5 3.0 m. In earth for [600 mm precast concrete block drain], depth exceeding 3.0 m. In earth for [1800 mm precast pipe culvert], depth exceeding 3.0 m. Extras to Drain Excavation P121 Roads and pavement, rate to include road cutting and reinstatement. Artificial hard material. Natural hard material. Rock. m2 m

P111.2

P112.1

P112.2

P113.1

P113.2

P114.1

P114.2

P115.1

P115.2

P122 P123 P124

m3 m3 m3

Page Total carried to S ummary of Class P Class P: Drainage Work Page BQP140 of BQP173

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

CLASS P Drainage Work


Item No. Code No. Description Excavation for Inlet and Outlet Structures and Sumps P131.1 In earth for inlet and outlet structures to [1800 mm x 1800 mm] precast box culvert. In earth for [1000 mm x 1000 mm] brick sump. Roads and pavement, rate to include road cutting and reinstatement. Artificial hard material. Natural hard material. Rock. m3 Unit Qty. Rate Amount (RM)

P131.2 P132

m3 m2

P133 P134 P135

m3 m3 m3

P200

SURFACE DRAINS Item for surface drains shall be deemed to include cement jointing, sand and concrete beddings, shuttering, struts, and weepholes.

P210

Interceptor drains; reinforced concrete grade 20; 1200 mm wide (average) x 600 mm deep x 75 mm thick trapezoidal shape. Bench and berm drains; reinforced concrete grade 20; 900 mm wide x 500 mm deep x 75 mm thick V-shape.

P220

P230

Roadside drain; 600 mm wide block drain with average 900 mm high brick wall and plastering including 600 mm x 100 mm x 100 mm precast concrete struts at 6 m c/c. Median drain; precast concrete U-shaped drain with dry weather flow; 600 mm wide x 1200 mm deep including precast concrete struts at 6 m c/c. Toe drain; precast concrete U-shaped drain with dry weather flow; 1200 mm wide x 1200 mm deep including precast concrete struts at 6 m c/c. Cascade drains; precast concrete block drain; 600 mm wide x 400 mm deep at berms. Monsoon drain; precast concrete U-shaped drain with dry weather flow; 2400 mm wide x 2400 mm deep including precast concrete struts at 6 m c/c. Grass swale; with shape as shown in Drawing No. (..).

P240

P250

P260

P270

P280

Page Total carried to Summary of Class P

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class P: Drainage Work Page BQP141 of BQP173

CLASS P Drainage Work


Item No. Code No. P300 Description SUBSURFACE DRAINS Item for subsurface drains shall be deemed to include geotextiles fabric, lining, and filter material. P310 Subsoil drains; 1000 mm deep x 400 mm wide; 100 mm diameter HDPE perforated pipe including aggregate (20 mm 40 mm) wrapped with geotextiles filter. m Unit Qty. Rate Amount (RM)

P320

Outlet drains; 100 mm diameter UPVC pipe including fittings. Rate to include bends, filter fabric and concrete surround. 300 mm thick sand as drainage blanket as per Specification clause (.). [150 mm] diameter scupper drains.

P330

m2

P340

P400

DRAINAGE TO STRUCTURES ABOVE GROUND

Rate for downpipes to include fixing and supply of fixing components. P410 P420 [150 diameter uPVC] rain water down pipes. [150 diameter uPVC] elbow for rain water down pipes. m nr

P500

DRAIN COVERS Item for drain covers shall be deemed to include lifting hook/hole and all associated fittings.

P510

Precast concrete; 600 mm wide x 75 mm thick for [100 kN load] median drain. Galvanised mild steel grating cover for [100 kN load], 600 mm wide as shown in Drawing No. (.) for road side drain. Fibre reinforced plastic for [100 kN load] as per Specification clause (.); 225 mm wide for roadside drain.

P520

P530

Page Total carried to Summary of Class P

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class P: Drainage Work Page BQP142 of BQP173

CLASS P Drainage Work


Item No. Code No. P600 CULVERTS Description Unit Qty. Rate Amount (RM)

Item for culverts shall be deemed to include all joints, water stop, concrete base, and concrete surround unless otherwise stated. P611 [1200 mm] diameter single precast concrete pipe culvert, Class [X] in standard length of 1 m. [1200 mm] diameter twin precast concrete pipe culvert, Class [X] in standard length of 1 m. [1200 mm] diameter triple precast concrete pipe culvert, Class [X] in standard length of 1 m. Precast Box Culvert P621.1 [1200 mm x 1200 mm] single precast box culvert in standard length of 1 m. [1200 mm x 1200 mm] single precast box culvert with dry weather flow in standard length of 1 m. [1200 mm x 1200 mm] twin precast box culvert in standard length of 1 m. [1200 mm x 1200 mm] twin precast box culvert with dry weather flow in standard length of 1 m. [1200 mm x 1200 mm] triple precast box culvert in standard length of 1 m. [1200 mm x 1200 mm] triple precast box culvert with dry weather flow in standard length of 1 m. Corrugated Metal Pipe P631 [1200 mm] diameter single corrugated metal pipe culvert in standard length of [] m. [1200 mm] diameter twin corrugated metal pipe culvert in standard length of [] m. [1200 mm] diameter triple corrugated metal pipe culvert in standard length of [] m. m m m

P612

P613

P621.2

P622.1

P622.2

P623.1

P623.2

P632

P633

Page Total carried to Summary of Class P

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class P: Drainage Work Page BQP143 of BQP173

CLASS P Drainage Work


Item No. Code No. P700 SUMPS Description Unit Qty. Rate Amount (RM)

Item for sumps shall be deemed to include sand and concrete bedding, cement plastering, and metalwork.

P710

Bricks sumps; 900 mm x 900 mm x 1.20 m deep including mild steel grating cover for [100 kN load].

nr

P720

In situ concrete; 900 mm x 900 mm x 1.20 m deep including mild steel grating cover for [100 kN load].

nr

P730

Precast concrete; 900 mm x 900 mm x 1.20 m deep including mild steel grating cover for [100 kN load].

nr

Page Total carried to Summary of Class P

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class P: Drainage Work Page BQP144 of BQP173

CLASS P Drainage Work


Item No. Code No. Description Summary of Class P: Drainage Work Page BQP1 Page BQP2 Page BQP3 Page BQP4 Page BQP5 Unit Qty. Rate Amount (RM)

Total of Class P carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class P: Drainage Work Page BQP145 of BQP173

CLASS Q Roads and Pavings


Item No. Code No. Q100 Q110 Description SUBGRADE PREPARATION Earth material to receive road pavement. Rate to include scarifying, levelling, and compaction of the top 300 mm of the subgrade. Hard material to receive road pavement. Rate to include scarifying, levelling, and compaction of the top 300 mm of the subgrade. Rock material to receive road pavement. Rate to include tri mming of protruding rock above Final Surface, filling of all cavities with lean concrete and filling with approved crushed rock or gravel to the Final Surface. m2 Unit Qty. Rate Amount (RM)

Q120

m2

Q130

m2

Q141

Stabilise subgrade for [300 mm] top layer of subgrade using [100 kg] of lime per cubic metre of soil

m2

Q142

Stabilise subgrade for [300 mm] top layer of subgrade using [800 kg] of cement per cubic metre of soil

m2

Q200

SUB-BASE Sub-base shall be deemed to include chamfer.

Q210

Geotextile of the [non woven] type as per Specification clause (.). Granular material with a [CBR value of more than 30, complying with Type C] of Specification clause (..) in [100 mm] thick. Granular material with a [CBR value of more than 30, complying with Type C] of Specification clause (..) in [100 mm] thick to road shoulders. Laterite as per Specification clause (..) in [100 mm] thick. [Grade C15] lean concrete in 150 mm thick. Stabilised sub-base in proportion of [one part] lime to [four parts] approved earth as per Specification clause (..) in [100 mm] thick. Soil cement in proportion of [one part] cement to [four parts] approved earth as per Specification clause (.) in [100 mm] thick.

m2

Q220.1

m2

Q220.2

m2

Q230

m2

Q240 Q251

m2 m2

Q252

m2

Page Total carried to Summary of Class Q

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class Q: Roads and Pavings Page BQQ146 of BQQ173

CLASS Q Roads and Pavings


Item No. Code No. Q300 ROADBASE Roadbase shall be deemed to include chamfer. Q310 Removal of flexible surfaces. Rate to include scarifying the existing roadbase before receiving the new roadbase material. Gravel (natural) as per Specification clause (..) in [300 mm] thick. Crushed aggregates with a [CBR value of more than 80, complying with Type II] of Specification clause (..) in [300 mm] thick. Crushed aggregates with a [CBR value of more than 80, complying with Type II] of Specification clause (..) in [300 mm] thick to road shoulders. Stabilised sub-base in proportion of [one part] lime to [four parts] approved earth as per Specification clause (..) in [300 mm] thick. Cement-bound granular material in proportion of [one part] cement to [three parts] granular material as per Specification clause (.) in [300 mm] thick. Bitumen-bound granular material in proportion of [one part] bitumen to [three parts] granular material as per Specification clause (.) in [300 mm] thick. Macadam Q351 Wet mix macadam as per Specification clause (.) in [200 mm] thick. Dry bound macadam as per Specification clause (.) in [200 mm] thick. Dense bituminous macadam as per Specification clause (.) in [200 mm] thick. m2 m2 Description Unit Qty. Rate Amount (RM)

Q320

m2

Q330.1

m2

Q330.2

m2

Q341

m2

Q342

m2

Q343

m2

Q352

m2

Q353

m2

Q400

ROAD SHOULDER Earth shoulders shall be deemed to include verge.

Q410

Earth shoulder as per Specification clause (.) in [200 mm] thick.

m2

Page Total carried to Summary of Class Q

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class Q: Roads and Pavings Page BQQ147 of BQQ173

CLASS Q Roads and Pavings


Item No. Code No. Q420 Description Gravel shoulder as per Specification clause (.) in [200 mm] thick. Unit m2 Qty. Rate Amount (RM)

Q500 Q510.1

SURFACING Removal of flexible surface. Rate to include scarifying the existing exposed surface. Removal of flexible surfaces. Rate to include milling of existing roadbase before receiving the new roadbase material. [Bituminuous single layer] surface dressing, [20 mm thick using 10 mm chippings]. [Bituminuous double layer] surface dressing, [30 mm thick using 14 mm chippings]. Tack coat to be applied at a rate of [0.5 litre per square metre] as per Specificatio clause (.). Prime coat to be applied at a rate of [0.35 litres per square metre] as per Specificatio clause (.). [12 mm] nominal thickness polymer modified asphalt in [2] layers as per Specification clause (.). m2

Q510.2

m2

Q520.1

m2

Q520.2

m2

Q530

m2

Q540

m2

Q550

m2

Asphaltic Concrete Q561 Binder course, [60 mm] thick as per Specification clause (.). Wearing course [40 mm] thick as per Specification clause (.). Dense Bituminuous Macadam Q571 Binder course, [60 mm] thick as per Specification clause (.). Wearing course [40 mm] thick as per Specification clause (.). Regulating bituminous macadam levelling course BML 10 to the required formation level. m2 m2

Q562

m2

Q572

m2

Q580

Page Total carried to Summary of Class Q

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class Q: Roads and Pavings Page BQQ148 of BQQ173

CLASS Q Roads and Pavings


Item No. Code No. Q600 Q611 Description CONCRETE PAVEMENT Membranes below concrete pavements, [500 grade impermeable plastic sheeting]. Bond breaker as per Specification clause (.) below concrete pavement. Bitumen below concrete pavement. Reinforcement Rate for reinforcement shall be deemed to include labour for cutting, bending, and placing. Q621.1 Mild steel bar reinforcement to nominal diameter [10 mm]. Mild steel bar reinforcement to nominal diameter [16 mm]. High tensile steel bar reinforcement to nominal diameter of [12 mm]. High tensile steel bar reinforcement to nominal diameter of [16 mm]. High tensile steel bar reinforcement to nominal diameter of [20 mm]. High tensile steel fabric reinforcement to MS 145, A6. t m2 Unit Qty. Rate Amount (RM)

Q612

m2

Q613

m2

Q621.2

Q622.1

Q622.2

Q622.3

Q623.1

m2

Q623.2

High tensile steel fabric reinforcement to MS 145, A7.

m2

Q623.3

High tensile steel fabric reinforcement to MS 145, A8.

m2

Q624 Q630

Fabric of other stated material. Carriageway slab in [Grade C30, 200 mm] thick. Rate to include steel formwork. Concrete slab to apron [Grade C30, 150 mm] thick. Rate to include steel formwork. Joints in Concrete Pavement Joints in concrete pavements shall be deemed to include base preparation, joints, and cutting.

m2 m2

Q640

m2

Q651 Q652 Q653

Longitudinal joints, [200 mm] deep. Expansion joints, [200 mm] deep. Construction joints, [200 mm] deep.

m m m

Page Total carried to Summary of Class Q

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class Q: Roads and Pavings Page BQQ149 of BQQ173

CLASS Q Roads and Pavings


Item No. Code No. Q654 Q655 Q656 Description Warping joints, [200 mm] deep. Butt joints, [200 mm] deep. Special joints with [12 mm nominal diameter high tensile steel bars] for transverse joints. Transverse joints, [200 mm] deep. Pavers Rate for pavers shall be deemed to include base preparation, joints, and cutting. Q661 [Precast] interlocking concrete block of [200 mm x 100 mm x 60 mm thick]. [Precast] concrete flags of [900 mm x 600 mm x 50 mm thick]. In situ concrete pavers, [concrete imprint, 150 mm thick]. m2 Unit m m m Qty. Rate Amount (RM)

Q657

Q662

m2

Q663

m2

Q700

KERBS, CHANNEL, AND EDGINGS Rate for kerbs, channels, and edgings shall be deemed to include beds, backings, reinforcement, joints, and cutting.

Q710.1

Precast concrete kerbs, Type I as shown in Drawing No. (.). Precast concrete kerbs, Type II as shown in Drawing No. (.). Precast concrete kerbs, Type III as shown in Drawing No. (.). Precast concrete kerbs, Type IV as shown in Drawing No. (.). In situ concrete kerbs, Type II as shown in Drawing No. (.). Concrete edgings of [150 mm x 100 mm high]. Concrete channels, Type A as shown in Drawing No. (.).

Q710.2

Q710.3

Q710.4

Q720

Q730 Q740

m m

Page Total carried to Summary of Class Q

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class Q: Roads and Pavings Page BQQ150 of BQQ173

CLASS Q Roads and Pavings


Item No. Code No. Q800 Description ROAD FURNITURE Signage Traffic signs shall generally be in accordance with JKR Arahan Teknik (Jalan) 2E/87 . Post mounted signages shall be deemed to include foundations, support posts, excavation, preparation of surfaces, disposal of excavated material, upholding sides of excavation, backfilling, concrete, reinforcement, and joints. Unit Qty. Rate Amount (RM)

Q811.1

Non-illuminated retro-reflective mounted on [aluminium] sheeting for [BERHENTI SIGN, RP.1].

nr

Q811.2

Non-illuminated retro-reflective mounted on [aluminium] sheeting for [BERI LALUAN SIGN, RP.13]. Non-illuminated retro-reflective mounted on [aluminium] sheeting for [ROUNDABOUT AHEAD SIGN, WD.31]. Non-illuminated retro-reflective in [aluminium] sheeting for [SIDE ROAD, WD.27b to be mounted on gantry].

nr

Q811.3

nr

Q811.4

nr

Q812

Illuminated in [plastic] sheeting for [SIDE ROAD, WD.27b to be mounted on gantry]. Electronic sign of [2.5 m] x [1.5 m] as per Specification clause (). Pavement Markings Pavement markings shall generally be hot-applied superimposed reflectorised thermoplastic and in accordance with JKR Arahan Teknik (Jalan) 2D/85.

nr

Q813

m2

Q821.1

Letters and shapes, [single straight directional arrow].

nr

Q821.2

Letters and shapes, [single turning directional arrow].

nr

Q821.3

Letters and shapes, [double headed directional arrow].

nr

Q822.1 Q822.2 Q823.1

[150 mm] wide continuous line [centre line] [150 mm] wide continuous line [edge line] [100 mm] wide intermittent [centre] line with [1000 mm] line and [1700 mm] gap

m m m

Page Total carried to Summary of Class Q

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class Q: Roads and Pavings Page BQQ151 of BQQ173

CLASS Q Roads and Pavings


Item No. Code No. Q823.2 Description [100 mm] wide intermittent [lane] line with [1000 mm] line and [1700 mm] gap. [100 mm] wide intermittent [continuity] line with [1000 mm] line and [1700 mm] gap. Chevron marking for [cross hatching]. Chevron marking for [diverging traffic]. Chevron marking for [merging traffic]. Delineators Q831 Non-illuminated retro-reflective in [aluminium] sheeting chevron delineators. Delineator posts as shown in Drawing No. (). [Retroreflective] roadstud as per Specification clause (..). Traffic Barrier Q841.1 [Preacst concrete] New Jersey barrier as shown in Drawing No. (.). [Cast in situ concrete] New Jersey barrier as shown in Drawing No. (.). Wire rope as per Specification clause (..). Rate to include bolts, nuts, posts, and other ancillary work. [Single mounted corrugated steel beam] guardrail [with post at 1.95 m spacing inclusive of delineators]. Rate to include bolts, nuts, posts, and other ancillary work. m nr Unit m Qty. Rate Amount (RM)

Q823.3

Q824.1 Q824.2 Q824.3

m2 m2 m2

Q832 Q833

nr nr

Q841.2

Q842

Q843.1

Q843.2

[Single mounted corrugated steel beam] guardrail [with post at 3.8 m spacing inclusive of delineators]. Rate to include bolts, nuts, posts, and other ancillary work.

Q843.3

[Double mounted corrugated steel beam] guardrail [with post at 1.95 m spacing inclusive of delineators]. Rate to include bolts, nuts, posts, and other ancillary work.

Q843.4

[Double mounted corrugated steel beam] guardrail [with post at 3.8 m spacing inclusive of delineators]. Rate to include bolts, nuts, posts, and other ancillary work.

Page Total carried to Summary of Class Q Class Q: Roads and Pavings Page BQQ152 of BQQ173

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

CLASS Q Roads and Pavings


Item No. Code No. Q844 Description Guardrail end [with 90 degrees ramped terminal treatment]. Rate to include bolts, nuts, posts, and other ancillary work. Pedestrian barrier of [1.5 m height] as shown in Drawing No. (.)]. Miscellaneous Q851 Q852 Crash cushion as per Specification clause (). [Concrete] crash barrier as shown in Drawing No. (.). nr nr Unit nr Qty. Rate Amount (RM)

Q845

Q853.1 Q853.2 Q854

Kilometre post, [Type A]. Kilometre post, [Type B]. Hectometre marker in [3 mm] thick [galvanised steel plate] at 100-metre intervals. Anti-glare screen of [1.5 m height using corrugated sections]. [Polycarbonate] noise barrier [of 1.5 m height] as per Specification clause (.). Rate to include supply, fabrication, installation, bolts, nuts, posts, and other ancillary work and maintenance. Right of way (ROW) marker as shown in Drawing No. (.). [Carbon steel overhead] gantry of [ 20 m wide and 6 m high].

nr nr nr

Q855

Q856

Q857

nr

Q860

nr

Page Total carried to Summary of Class Q

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class Q: Roads and Pavings Page BQQ153 of BQQ173

CLASS Q Roads and Pavings


Item No. Code No. Description Summary of Class Q: Roads and Pavings Page BQQ1 Page BQQ2 Page BQQ3 Page BQQ4 Page BQQ5 Page BQQ6 Page BQQ7 Page BQQ8 Unit Qty. Rate Amount (RM)

Total of Class Q carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class Q: Roads and Pavings Page BQQ154 of BQQ173

CLASS R Tunnel Work


Item No. Code No. R100 Description SPECIAL PRELIMINARIES Plant and Equipment R110 Provision of all necessary plant and equipment as per Specification clause () including transportation to the Site, handling, assembling, and removal off the Site after completion of operation. Tunnelling shall be carried out by [tunnel boring machine] for the main tunnel and [drill and blast] for the [adit, shaft, and other underground space]. Temporary Facilities R121 Power supply system as per Specification clause (). sum sum Unit Qty. Rate Amount (RM)

R122

Ventilation system as per Specification clause ().

sum

R123 R124

Lighting system as per Specification clause (). Compressed air system as per Specification clause ().

sum sum

R125

Telecommunication system as per Specification clause (). Dewatering system as per Specification clause ().

sum

R126

sum

R129

Water supply system as per Specification clause ().

sum

Tunnel Portal R130 Tunnel portal as per Specification clause () and as shown in Drawing No. (). Rate to include steel ribs, shotcrete, sandbags, and all other necessary material and work including its subsequent removal. sum

Page Total carried to Summary of Class R

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class R: Tunnel Work Page BQR155 of BQR173

CLASS R Tunnel Work


Item No. Code No. R200 EXCAVATION Tunnel, Shaft, and Other Underground Space Rate for excavation shall be deemed to include: a) all alignment and inclination; b) scaling, washing down, multiple handling, and disposal off the Site or to designated area within the Site; c) overbreak and backfill with shotcrete or other approved material; and d) water and power consumption for plant, equipment and temporary facilities. R211.1 Excavation of [3.5 m] diameter tunnel in rock class [A to D] as shown in Drawing No.(). Excavation of [3.5 m] diameter tunnel in rock class [E] as shown in Drawing No.(). Excavation of [3.5 m] diameter tunnel in [residual soil] as shown in the drawings. [The excavated material shall be disposed at the designated location within the Site as shown in Drawing No.()]. Excavation of [5 m] diameter shaft in rock Class [A to D] as shown in Drawing No.(). Excavation of [5 m] diameter shaft in rock Class [E] as shown in Drawing No.(). Excavation of [5 m] diameter shaft in [alluvium] as shown in the drawings. [The excavated material shall be disposed at the designated location within the site as shown in Drawing No.()]. m3 Description Unit Qty. Rate Amount (RM)

R211.2

m3

R212

m3

R221.1

m3

R221.2

m3

R222

m3

R231

Excavation of [5 m x 10 m x 30 m long storage chamber] in rock Class [A to D] as shown in the drawings.

m3

Page Total carried to Summary of Class R

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class R: Tunnel Work Page BQR156 of BQR173

CLASS R Tunnel Work


Item No. Code No. Description Enlarge Tunnel Section Rate for enlarge tunnel section shall be deemed to include all necessary tunnel support and backfilling with [grade C30 concrete] to design profile after completion of tunnel work. R241 R242 R243 R244 R245 Assembly and dismantle yards. Vehicle turnings. Switching stations. Transformer bays. Pump sumps. Drilling Rate for drilling shall be deemed to include installation of pipe as shown in the drawings. R251 R252 R253 [50 mm] diameter probe ahead hole in [rock]. [50 mm] diameter drain hole in [rock]. [50 mm] diameter grout hole in [rock]. Grouting R260.1 R260.2 Cement. Polyurethane. t t m m m sum sum sum sum sum Unit Qty. Rate Amount (RM)

R300

IN SITU LINING Shotcrete Refer Specification clause () for shotcrete work.

R311.1 R311.2 R312.1

[100 mm] thick plain shotcrete to [smooth finish]. [50 mm] thick plain shotcrete to [rough finish]. [150 mm] thick [mesh] reinforced shotcrete to [smooth finish]. [100 mm] thick [steel fibre] reinforced shotcrete, [30 kg/m3] to [fair finish].

m2 m2 m2

R312.2

m2

Page Total carried to Summary of Class R Class R: Tunnel Work Page BQR157 of BQR173

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

CLASS R Tunnel Work


Item No. Code No. In situ Concrete Rate for in situ concrete shall be deemed to include contact grouting at tunnel crown. R320 Reinforced concrete [grade C35A] to [tunnel] lining [with early strength admixtures] as per Specification clause (). Reinforcement Rate for reinforcement shall be deemed to include labour for cutting, bending, and placing. R331 R332.1 R332.2 R333 Mild steel bars [6 mm to 16 mm]. High tensile bars [6 mm to 16 mm]. High tensile bars [20 mm to 32 mm]. High tensile steel fabric [mesh A252 (A8), 3.95 kg/m2]. t t t m2 m3 Description Unit Qty. Rate Amount (RM)

R334

[Stainless steel] fabric [mesh A393(A10), 6.16 kg/m2].

m2

Formwork Rate for formwork shall be deemed to include travel steel form for all inclination, alignment, and end form to construction joints. R340 Smooth finish to [tunnel] lining. Water Proofing R351.1 [230 mm] wide rubber waterstop. Rate to include cutting and jointing of waterstops and provision of special fittings at angles and junctions. [250 mm] wide PVC waterstop. Rate to include cutting and jointing of waterstops and provision of special fittings at angles and junctions. [1 mm] thick [HDPE] membrane. [2 mm] thick [PVC] membrane. [Water proofing paint] as per Specification clause (). m m2

R351.2

R352.1 R352.2 R352.3

m2 m2 m2

Page Total carried to Summary of Class R

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class R: Tunnel Work Page BQR158 of BQR173

CLASS R Tunnel Work


Item No. Code No. R400 Description PREFORMED LINING Preformed Concrete Lining Rate for preformed concrete lining shall be deemed to include reinforcement, formwork, packing, caulking, joint seal, finishes, and preformed threaded grout holes. Unit Qty. Rate Amount (RM)

R411

[5 m] internal diameter x [200 mm] thick segmental ring as shown in Drawing No.(). [200 mm] thick invert segment as shown in Drawing No.(). [Steel Lining, Cast Iron Lining and Ductile Iron Lining] Rate for [steel, cast iron and ductile iron] lining shall be deemed to include cutting and jointing, internal and external corrosion protection, stiffeners, fish tails, and purpose-made holes for annulus grouting.

R412

R420

[50 mm thick, grade 50B] steel lining of [3.5 m] internal diameter as per Specification clause (). [40 mm thick, grade 600/3] cast iron lining of [4 m] internal diameter as per Specification clause ().

R430

R440

[30 mm thick, grade 500/7] ductile iron lining of [5 m] internal diameter as per Specification clause ().

Annulus Grouting R450 Annulus grouting with [cement grout of w/c ratio 0.45:1] under [2] bars pressure. Water Proofing R460 [1 mm] thick [HDPE] membrane. m2 m3

Page Total carried to Summary of Class R

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class R: Tunnel Work Page BQR159 of BQR173

CLASS R Tunnel Work


Item No. Code No. R500 Description TUNNEL SUPPORT Steel Rib Rate for steel rib shall deemed to include all necessary accessories such as tie rods, end plate, bolts and nuts. Unit Qty. Rate Amount (RM)

R510.1 R510.2

Steel rib [H100 x 100 x 8 mm thick, 17.2 kg/m]. Steel rib [H125 x 125 x 9 mm thick, 23.8 kg/m].

t t

Lagging R521 C-channel [C100 x 50 x 4 mm thick, 5.87 kg/m]. t

R522 R523

Steel plate [5 mm] thick. Mesh fabric [A142 (A6), 2.22 kg/m2]. Rate to include lapping and mesh pin. Bolting Rate for bolting shall be deemed to include all accessories and ancillary work as shown in the drawings. Exposed elements shall be protected against corrosion.

t m2

R531.1 R531.2 R532.1 R532.2 R533

[T20 mm dia.] rock dowel of [1.5 m] long. [T25 mm dia.] rock dowel of [2 m] long. [T25 mm dia.] rock bolt of [2 m] long. [T25 mm dia.] rock bolt of [3 m] long. Pull out test for [T25 mm dia. rock bolt x 3 m long] with test load of [200 kN]. Shotcrete

nr nr nr nr nr

R541

[50 mm] thick plain shotcrete as per Specification clause () to [rough finish]. [150 mm] thick [steel fibre reinforced shotcrete (30 kg/m3)] as per Specification clause () to [rough finish]. Fibre Mortar

m2

R542

m2

R550

[25 mm] thick fibre mortar as per Specification clause () and as shown in the drawings.

m2

Page Total carried to Summary of Class R

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class R: Tunnel Work Page BQR160 of BQR173

CLASS R Tunnel Work


Item No. Code No. Forepoling R561 Forepoling with [T25 mm] diameter dowel bar of [12 m] long as shown in the drawings. Forepoling with [100 mm] diameter canopy tube of [4 mm] thick and [12 m] long as shown in the drawings. nr Description Unit Qty. Rate Amount (RM)

R562

nr

R600 R611 R612 R613 R614 R615 R621 R622 R623 R624 R631

BACKFILL Backfill invert with concrete [grade C20]. Backfill invert with plain shotcrete. Backfill invert with mortar [1:3]. Backfill invert with [cement grout 0.45:1]. Backfill invert with tunnel muck. Backfill behind lagging with concrete [grade C20]. Backfill behind lagging with plain shotcrete. Backfill behind lagging with mortar [1:3]. Backfill behind lagging with [cement grout 0.45:1]. Backfill [adit entrance] with concrete [grade C30] as shown in Drawing No.(). m3 m3 m3 m3 m3 m3 m3 m3 m3 m3

R700

INSTRUMENTATION Rate for instrumentation shall include all provision as expressly required in Specification clause ().

R710 R720 R731 R732 R733 R734

Convergence measurement. Settlement measurement. Stress measurement with strain gauges. Stress measurement with pressure cells. Inclinometer. Stress measurement with pneumatic piezometer.

nr nr nr nr nr nr

Page Total carried to Summary of Class R

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class R: Tunnel Work Page BQR161 of BQR173

CLASS R Tunnel Work


Item No. Code No. Description Summary of Class R: Tunnel Work Page BQR1 Page BQR2 Page BQR3 Page BQR4 Page BQR5 Page BQR6 Page BQR7 Unit Qty. Rate Amount (RM)

Total of Class R carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class R: Tunnel Work Page BQR162 of BQR173

CLASS S Rails Track


Item No. Code No. S100 Description TRACK FOUNDATION Item for track foundation shall be deemed to include supplying and laying of materials. Subgrade Preparation S111 Earth material to receive track foundation. Rate to include scarifying, levelling, and compaction of the top 300 mm of the subgrade. Hard material to receive track foundation. Rate to include scarifying, levelling, and compaction of the top 300 mm of the subgrade. Rock material to receive track foundation. [One layer of 5 mm thick waterproofing membrane] as per Specification clause (.). Geotextile of the [non-woven] type as per Specification clause (.). Granular material with a [CBR value of more than 30, complying with Type C] of Specification clause (..) in [100 mm] thick. [Crushed aggregates] for sub-ballast complying with Specification clause (..). [Crushed granite] for ballast complying with Specification clause (..). m2 Unit Qty. Rate Amount (RM)

S112

m2

S113 S120

m2 m2

S130

m2

S140

m2

S150

m3

S160

m3

S200

SUPPLYING Item for supplying shall be deemed to include delivery of components to the Site.

S210

Flat bottom rails, [reference 113A] as per Specification clause (.), mass [56 kg/m]. Check and guard rails, mass 0.10 tonne/m as per Specification clause (.). Conductor rails as per Specification clause (.). Twist rails.

S220

S230 S240

t nr

Page Total carried to Summary of Class S

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class S: Rail Tracks Page BQS163 of BQS173

CLASS S Rails Track


Item No. Code No. Sleepers Item for supplying sleepers shall be deemed to include fittings attached by the supplier. S251 [] x [] x [.] mm thick Grade A heavy hardwood timber sleepers. [] x [] x [.] mm thick Grade [30] concrete sleepers with profile as shown in Drawing No. (....). nr Description Unit Qty. Rate Amount (RM)

S252

nr

Fittings Item for supplying fittings shall be deemed to include fixings, keys, clips, bolts, nuts, screws, spikes, ferrules, track circuit insulators, pads, conductor rail insulator, and packing. S261 S262 Type (.) chairs as per Specification clause (). Type (.) baseplates as per Specification clause (). nr nr

S263

[Pandrol] rail fastenings, type [.] as per Specification clause (). Type (.) plain fishplates as per Specification clause (). Type (.) plain insulated fishplates as per Specification clause (). Conductor rail insulators as per Specification clause (.). Conductor rail side ramps. SUPPLYING Item for supplying shall be deemed to include delivery of components to the Site.

nr

S264

nr

S265

nr

S266

nr

S267 S300

nr

S310

Type [..] turnouts as shown in Drawing No. (.). Rate to include timbers, fittings, and check rails.

nr

S320

Type [..] diamond crossing as shown in Drawing No. (.). Rate to include timbers, fittings, and check rails.

nr

Page Total carried to Summary of Class S

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class S: Rail Tracks Page BQS164 of BQS173

CLASS S Rails Track


Item No. Code No. Sundries S331 Buffer stops, approximate weight 2.5 tonnes of steel rail and timber sleeper construction. Wheel stops. Lubricators. Switch levers. Conductor rail guard boards. nr Description Unit Qty. Rate Amount (RM)

S332 S333 S334 S335

nr nr nr nr

S400

LAYING Item for laying shall be deemed to include work carried out after delivery of components to the Site or where track is not to be supplied by the Contractor, to the location stated in Specification clause ().

Flat Bottom Rails S411 Plain track, rail reference 113A, mass 56 kg/m and prefabriacted in [10m] length, fish plated joints on timber sleepers. Form curve in plain track radius not exceeding 300 m, welded joints on concrete sleepers Form curve in plain track radius exceeding 300 m, fishplated joints on timber sleepers. Turnouts type [..] as shown on Drawing No. (.), length [.] m, fishplated joints on timber sleepers. m

S412

S413

S414

nr

S415

Diamond crossings type [..] as shown on Drawing No. (.), length [.] m, fishplated joints on timber sleepers.

nr

S416

Welded joints by quick thermit process as per Specification clause (.). Spot re-sleepering. Check and Guard Rails

nr

S417

nr

S421 S422 S423 S424

Rail. Length ends. Side ramps. Welded joints by quick thermit process as per Specification clause (.).

m nr nr nr

Page Total carried to Summary of Class S

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class S: Rail Tracks Page BQS165 of BQS173

CLASS S Rails Track


Item No. Code No. Conductor Rails S431 S432 S433 S434 Rail. Length ends. Side ramps. Welded joints. Sundries S441 Buffer stops, approximate weight 2.5 tonnes of steel rail and timber sleeper construction. Wheel stops. Lubricators. Switch levers, rate to include laying check rails. Conductor rail guard boards. nr m nr nr nr Description Unit Qty. Rate Amount (RM)

S442 S443 S444 S445

nr nr nr m

S500

DISMANTLING Dismantling shall include taking up, lifting, packing and slewing, and to include opening out, packing and boxing in with ballast and insertion of closure rails.

Flat Bottom Rails S511 Plain trackrail reference 113A, mass 56 kg/m, fish plated joints on timber sleepers. Dismatled material shall be stored at [storage yard at main site office]. m

S512

Turnouts type [..], length [.] m, fishplated joints on timber sleepers. Rate to include checkrail, guardrail, and conductor rails. Diamond crossings type [..], length [.] m, fishplated joints on timber sleepers. Rate to include checkrail, guardrail, and conductor rails. Check and guard rails. Conductor rails.

nr

S513

nr

S520 S530

m m

Page Total carried to Summary of Class S

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class S: Rail Tracks Page BQS166 of BQS173

CLASS S Rails Track


Item No. Code No. Sundries S541 Buffer stops, approximate weight 2.5 tonnes of steel rail and timber sleeper construction Wheel stops. Lubricators. Switch levers. nr Description Unit Qty. Rate Amount (RM)

S542 S543 S544

nr nr nr

Page Total carried to Summary of Class S

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class S: Rail Tracks Page BQS167 of BQS173

CLASS S Rails Track


Item No. Code No. Description Summary of Class S: Rail Tracks Page BQS1 Page BQS2 Page BQS3 Page BQS4 Page BQS5 Unit Qty. Rate Amount (RM)

Total of Class S carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class S: Rail Tracks Page BQS168 of BQS173

CLASS T Miscellaneous Work


Item No. Code No. T100 FENCES Items for fences shall be deemed to include excavation, preparation of surfaces, disposal of excavated material, upholding sides of excavation, backfilling, concrete, formwork, reinforcement, and all posts and foundation. Description Unit Qty. Rate Amount (RM)

T110

[1200 mm wide x 25 mm thick close boarded wrot finish Grade A balau heavy hardwood complete with 150 mm x 150 mm posts at 3 m centres, 1.80 m high] as shown in Drawing No. (). [40 x 40 x 2.6 mm thick square mild steel hollow section at 100 mm centres bothways welded as a frame 1.5 m high with 80 x 80 x 3.6 mm thick post at 2 m centres] as shown in Drawing No. (.). [3 mm] diameter [PVC-coated galvanised] mild steel wire of [50 mm] square mesh, [2 m] overall height chain link fencing complete with post at [3 m] centres as shown in Drawing No. (.). Rate to include all posts, raked angle, straining wires, barb wires, concrete kerbs, and foundations as shown.

T120

T130

Barb/Bladed Wire T140 [12 SWG galvanised mild steel] barbed/bladed wire fencing; [1.2 m] high with [50 x 50 x 4.5 mm thick] mild steel angle as post planted in mass concrete bases at [2.0 m] centres and including [150 mm high] concrete kerb as shown in Drawing No. (..). [Brick and mild steel grille fencing; comprising 500 mm high, 115 mm thick brick wall with concrete coping rendered with 19 mm thick cement sand plaster; 230 mm x 230 mm brickwork post; mild steel decorative grille fencing 750 mm high; framed and welded together, all on and including reinforced concrete strip footing as shown in Drawing No. (.....)]. m

T150

T200

GATES Items for gates shall be deemed to include excavation, preparation of surfaces, disposal of excavated material, upholding sides of excavation, backfilling, concrete, formwork, reinforcement, posts and foundations, hinges, bolts, rollers, lockplates, and all necessary welding.

T210

Double leave Grade A balau heavy hardwood gate [2400 mm x 1500 mm high] overall complete with [100 mm x 100 mm] hardwood posts and ironmongery as shown in Drawing No. ().

nr

Page Total carried to Summary of Class T

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class T: Miscellaneous Work Page BQT169 of BQT173

CLASS T Miscellaneous Work


Item No. Code No. T220.1 Description Double leave mild steel gate [3000 mm x 1500 mm high], consisting of [50 x 30 x 3.2 mm thick] rectangular hollow section as frame welded together with [30 x 30 x 2.6 mm thick] square hollow section; including painting, ironmongery; fixing with hinges on lugs built in masonry backing as shown in Drawing No. (........). Unit nr Qty. Rate Amount (RM)

T220.2

Single leaf mild steel automatic gate [3000 mm x 1500 mm high], consisting of [50 x 30 x 3.2 mm thick] rectangular hollow section as frame welded together with [30 x 30 x 2.6 mm thick] square hollow section; including painting, ironmongery; fixing with hinges on lugs built in masonry backing as shown in Drawing No. (........). Rate to include motor and automatic control system.

nr

Chain Link Item for chain link shall be deemed to include all posts, raked angle, straining wires, barb wires, kerbs where applicable and their foundation. T230 [3 mm] diameter [PVC-costed galvanised mild steel wire of 50 mm square mesh, [3.0 m wide x 2.5 m overall height double leave chain link gate with 60.3 mm OD x 5 mm thick circular hollow section as frame as shown in Drawing No. (.....). Rate to include all posts, hinges, bolts, lock plates, angle braces, barb wires, all necessary welding and foundations as shown. nr

T240

Double leave galvanised barbed wire [2400 mm x 2000 mm high] gates; comprising [50 x 50 x 4.5 mm thick] mild steel angle frame as shown in Drawing No (..). Double leave gate, [2400 mm x 1200 mm high] with 100 mm x 100 mm Grade A wrot finish heavy hardwood as frame and 12 SWG galvanised barbed wire as shown in Drawing No. (.).

nr

T250

nr

Page Total carried to Summary of Class T

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class T: Miscellaneous Work Page BQT170 of BQT173

CLASS T Miscellaneous Work


Item No. Code No. T300 Description SIGNAGES FOR BUILDINGS AND TANKS Rate for internal and external signages shall be deemed to include fixing complete. Painting of Logos Supply and paint [SYABAS] logo and lettering for [water tank] at [Taman Gembira Cheras] as detailed in the drawings and the following: T310.1 Paint [SYABAS] logo for [water tank] at [Taman Gembira Cheras] as per Specification clause (.) and detailed in Drawing No. (.). Paint [TNB] logo for sub-station as per Specification clause (.) and detailed in Drawing No. (.). nr Unit Qty. Rate Amount (RM)

T310.2

nr

External Signages T320 Paint lettering for [water tank] at [Taman Gembira Cheras] as per Specification clause (.) and detailed in Drawing No. (.). Internal Signage Internal signage shall be as per Specification clause (). T330.1 T330.2 T330.3 T400 Laboratory. Work manager room. Control room. BEARING PADS Bridge bearing Supply and install the following bearings inclusive of mortar grout, epoxy mortar, and all temporary work. nr nr nr nr

Roller T411.1 Single roller bearing as shown in Drawing No. (..). nr

T411.2

Multiple roller bearing as shown in Drawing No. (..).

nr

Page Total carried to Summary of Class T

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class T: Miscellaneous Work Page BQT171 of BQT173

CLASS T Miscellaneous Work


Item No. Code No. Slide T412.1 Plane sliding bearing as shown in Drawing No. (..). nr Description Unit Qty. Rate Amount (RM)

Rocker T413.1 Cylindrical rocker bearing as shown in Drawing No. (..). Spherical rocker bearing as shown in Drawing No. (..). nr

T413.2

nr

Plain rubber T414 [300 x 300 x 60 mm thick] plain rubber bearing as shown in Drawing No. (..). Laminated rubber T415 [300 x 300 x 80 mm thick] elastomer laminated rubber bearing as shown in Drawing No. (..). Pot bearing T416.1 Sliding guided pot bearing as shown in Drawing No. (..). Free standing pot bearing as shown in Drawing No. (..). Other bearing T424 300 mm wide x 60 mm thick plain rubber bearing for joint between dome roof and wall as shown in Drawing No. (..). nr nr nr nr

T416.2

nr

Page Total carried to Summary of Class T

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class T: Miscellaneous Work Page BQT172 of BQT173

CLASS T Miscellaneous Work


Item No. Code No. Description Summary of Class T: Miscellaneous Work Page BQT1 Page BQT2 Page BQT3 Page BQT4 Unit Qty. Rate Amount (RM)

Total of Class T carried to Grand Summary

\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office

Class T: Miscellaneous Work Page BQT173 of BQT173

You might also like