Professional Documents
Culture Documents
Item No. Code No. A100 Description CONTRACTUAL REQUIREMENTS Bond A111 A112 Performance Bond. Design Guarantee Bond [for roof structure (to be designed by the Contractor) of (..)]. Insurances A121 A122 A123 Insurance of the Works. Public Liability Insurance. SOCSO/Workmen Compensation Insurance. Statutory Obligations A131 A140 CIDB Levy. Stamp duty. sum sum sum sum sum sum sum Unit Qty. Rate Amount (RM)
A200
ENGINEER/SO/PD'S REQUIREMENTS Facilities for the Engineer/SO/PD's representative. Rate shall be deemed to include the provision of water supply, electricity, and communication facilities.
A211
Establishment and removal of [transportable type cabin] office [with a floor area of 70 m2]. Maintenance of office. Establishment and removal of [purpose built] laboratories [with a floor area of 60 m2 as shown in Drawing Nos. (.) to (..)]. Maintenance of laboratories. Equipment for Use by the Engineer/SO/PD's Representative
sum
A212 A213
mth sum
A214
mth
A221
Establishment and removal of office equipment [with type and quantity as per Specification clause (). Equipment to be reverted to the Contractor after completion]. Maintenance of office equipment.
sum
A222
mth
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
A224 A225
mth sum
A226
mth
A231.1
Provision of transport vehicle [Type A as per Specification clause (..). Vehicle to be reverted to the Contractor after completion]. Provision of transport vehicle [Type B as per Specification clause (..). Vehicle to be reverted to the Contractor after completion]. Maintenance of vehicle [Type A]. Maintenance of vehicle [Type B]. Provision of mobile phones [and to be reverted to the Contractor after completion]. Maintenance of mobile phones. Provision of camera [and to be reverted to the Contractor after completion]. Attendance for Engineer/SO/PD's Representative
sum
A231.2
sum
A234 A235
mth sum
[2 Nos.] Drivers for [Type A and Type B vehicle]. [2 Nos.] Survey assistants. [2 Nos.] Laboratory assistants. [4 Nos.] General labours. [2 Nos.] Security guards.
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
A252 A253
sum sum
A254
sum
A261
Progress report [ in five sets]. Rate to include progress photographs. Project signboard. As built drawings. Video recording [as per Specification clause (....)].
mth
nr sum sum
A265
sum
A300 A310
PROJECT REQUIREMENTS Survey and setting out [by licensed surveyor]. Quality Assurance/Quality Control (QA/QC) sum
A321 A322
QA/QC Plan [as per Specification clause (..)]. Testing of materials; [concrete test cubes; samples and method of testing as per Specification clause (..)]. Testing of work [for cold water plumbing system as per Specification clause (.)]. Factory acceptance test [for hydrostatic testing of butterfly valves] for three (3) person of the S.O. representatives. Testing and commissioning [of plant for a duration of three (3) months]. Operation and Maintenance of Plant
sum
sum
A323
sum
A324
sum
A325
sum
A331 A332
Operation and Maintenance Manual. Training of operating personnel [for a period of 10 weeks].
sum sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
A334
Provision of chemicals and consumable [for a period of 12 months]. Utility cost [for a period of 12 months]. Maintenance of Road
sum
A335
sum
A341
Routine maintenance for existing road as per Specification clause [..]. Periodic maintenanceas for existing road per Specification clause [..]. Routine maintenance for temporary road diversion as per Specification clause [..]. Periodic maintenance for temporary road diversion as per Specification clause [..]. Clearance of site upon completion.
sum
A342
sum
A343
sum
A344
sum
A350
sum
A400
A411 A412
Health and safety plan. Occupational safety and health officer [for duration of the contract period]. Personnel protective equipment as per Specification clause [..]. Health and safety report [in five sets. Rate to include tool box meeting]. Training of health and safety as per Specification clause [..]. Safety signages. Permits and fees [to KTMB for pipe jacking work across railway tracks at (.)]. Deposit [to JKR for pipelaying work along road verge from (..) to ()].
sum man-mth
A413
sum
A414
mth
A415
sum
A416 A420
sum sum
A430
sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
A511.1
Set up offices and remove upon completion; fixed charge. Maintain office for duration of contract period; timerelated charge. Provision of office equipment and remove upon completion; fixed charge. Maintain office equipment for duration of contract period; time-related charge. Set up laboratories and remove upon completion; fixed charge. Maintain laboratories for duration of contract period; time-related charge. Provision of laboratories equipment and remove upon completion [with type and quantity as per Specification clause ()]. Maintain laboratories equipment for duration of contract period; time-related charge. Set up stores and remove upon completion; fixed charge.
sum
A511.2
sum
A512.1
sum
A512.2
sum
A513.1
sum
A513.2
sum
A514.1
sum
A514.2
sum
A515.1
sum
A515.2
Maintain store for duration of contract period; timerelated charge. Set up workshops and remove upon completion; fixed charge. Maintain workshop for duration of contract period; timerelated charge. Set up workmen accomodation and remove upon completion; fixed charge. Maintain workmen accomodation for duration of contract period; time-related charge. Provision of transport. Maintain transport for duration of contract period; timerelated charge.
sum
A516.1
sum
A516.2
sum
A517.1
sum
A517.2
sum
A518.1 A518.2
sum sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
A521.2
Maintain temporary access roads for duration of contract period; time-related charge. Construct temporary bridges and remove upon completion [over Sg. ()]; fixed charge. Maintain temporary bridges for duration of contract period; time-related charge. Construct cofferdams for [water intake] and remove upon completion; fixed charge. Maintain cofferdam for duration of construction; timerelated charge. Install pumping and dewatering at [pumphouse] and remove upon completion; fixed charge. Operation and maintenance of pumping and dewatering for duration of construction; time-related charge.
sum
A522.1
sum
A522.2
sum
A523.1
sum
A523.2
sum
A524.1
sum
A524.2
sum
A525.1
Construct river diversion for [water intake] and reinstate to its original alignment upon completion; fixed charge.
sum
A525.2
Maintain river diversion for duration of construction; time-related charge. Construct temporary jetty [at Sg. ()] and remove upon completion; fixed charge. Maintain temporary jetty for duration of contract period; time-related charge. Construct temporary staging over [Sg. (.)] and remove upon completion; fixed charge. Maintain temporary staging for duration of construction; time-related charge. Site Management
sum
A526.1
sum
A526.2
sum
A527.1
sum
A527.2
sum
A531
Site agent for the duration of conract period; timerelated charge. QA/QC officer for the duration of contract period.
sum
A532
man-mth
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
DESIGN AND BUILT ELEMENT Preliminary engineering studies. Design survey. Utilities survey. Site investigation. Design fees. Independent Checkers sum sum sum sum sum
A700
A711.1
Provisional Sum of [RM: Two hundred thousands only for TNB contribution]. Provisional Sum of [RM: Five hundred thousands only for piling work]. Provisional Sum of [RM: Three hundred thousands only for staff quarters to be procured by the Employer].
sum
A711.2
sum
A711.3
sum
A711.4 A711.5
Attendance [for Item A711.3]. Profit for [Item A711.3]. Prime Cost Items
sum %
A721
Prime Cost Sum of [RM: One million only for reinforced soil wall]. Attendance. Profit.
sum
A722 A723
sum %
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
B110
B120
Appointment of environmental officer (EO) for the duration of the contract period.
man-mth
B200
EROSION AND SEDIMENT CONTROL PLAN (ESCP) Items for silt fence, silt curtain, sand bags, gabion wall, and rock check dam shall be deemed to include provisions as per Specification clause (............) and removal of the items upon completion. Silt fence of [1.0 m height] as per Specification clause (..) and as shown in the drawings. Silt curtain as per Specification clause (.) and as shown in the drawings. Sand bag as per Specification clause (.) and as shown in the drawings. Rock-filled gabion wall with PVC coated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in the drawings. Rock check dam as per Specification clause (.) and as shown in the drawings. Sediment Basin m
B210
B220
m2
B230
nr
B240
m3
B250
m3
B261 B262
Excavation. Granular filling. Rate to include imported fill as necessary. Concrete grade [C25]. Rate to include formwork and reinforcement. Class X, 1.0 m diameter reinforced concrete pipe. Geotextile as per Specification clause (.). Rock-filled gabion with PVC-coated wire gauge size of [2.7 mm] as per Specification clause (.).
m3 m3
B263
m3
m m2 m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
B268
m2
B273
m3
m m2 m3
B277
m2
B278
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
B310
B320
Water treatment facilities for [effluent from tunnel work to comply with Standard (A/B) of the Environmental Quality Act]. Sewage treatment facilities for [workmen accomodation]. Water Quality Sampling and In situ Testing Water quality sampling and monitoring by accredited laboratory on a monthly basis [at the discharge outlet of silt trap/sedimentation basin to comply with the requirements of Standard (A/B) of the Environmental Quality Act for the following parameters].
sum
B330
sum
pH Total suspended solid (TSS). Dissolved Oxygen (DO) Ammoniacal nitrogen Water Quality Sampling and Laboratory Testing Water quality sampling and monitoring by accredited laboratory on a monthly basis [at the effluent discharge point at workmen accommodation, workshop, and canteen to comply with the requirements of Standard (A/B) of the Environmental Quality Act for the following parameters].
nr nr nr nr
pH. Total suspended solid (TSS). Biochemical oxygen demand (BOD). Chemical oxygen demand (COD). Dissolved oxygen (DO). Escherichia coli (E.coli).
nr nr nr nr nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
B400 B410
AIR QUALITY CONTROL AND MONITORING Tyre washing facilities [in reinforced concrete of size 6 m x 3.6 m as per Specification clause (..) and as shown in the drawing]. Rate to include construction of tyre washing concrete platform, and provision and maintenance of water supply system and portable water jets. Wash trough of [size 6 m x 3.6 m in reinforced concrete, hardcore, and aggregate layers as per Specification clause (..) and as shown in the drawing]. set
B420
nr
B430
Water bowser truck [for carrying out water spraying along haul/access roads and existing roads, and near settlements, for at least three times per day]. Rate to include the provision and maintenance of the vehicle and water supply, and the driver.
nr
B440
Water sprinkler [for control of dust at quarry/batching plant using pumping system]. Rate to include provision and maintenance of water supply.
sum
Air Quality Sampling Air quality sampling by accredited laboratory on a quarterly basis for the following parameters: B451 Total suspended particulates (TSP) over a 24 hours period. Wind velocity and direction. Particulate matter (PM10). nr
B452 B453
nr nr
B500
NOISE AND VIBRATION CONTROL AND MONITORING [Polycarbonate] noise barrier [of 1.5 m height] as per Specification clause (.). Rate to include supply, fabrication, installation, bolts, nuts, posts, and other ancillary work and maintenance. Vibration control. m
B510
B520
sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Ambient noise level measurement. Spot noise level measurement. Vibration measurement and monitoring by accredited laboratory on a quarterly basis near Taman (..).
nr nr sum
B600 B610
WASTE MANAGEMENT Scheduled wastes as per Specification clause (). Rate to include storage, labelling, and transportation from site by a licensed contractor for disposal as per the Department of Environment (DOE) regulation. sum
B620
Household solid waste as per Specification clause (). Rate to include provision of collection bins, temporary storage area, and disposal to approved site.
sum
B630
Construction solid waste as per Specification clause (). Rate to include provision of collection bins, temporary storage area, and disposal to approved site.
sum
B640
Biomass disposal as per Specification clause (). Rate to include preparation and construction of temporary area, and the disposal to approved site.
sum
B700
B711 B712
Flora survey report [in five sets]. Relocation of flora of the (.) species to the temporary site near the [site office] and finally to the (..) forest reserve. Rate to include the cost of relocation to the temporary and the final site specified. It shall also include excavation, transportation, protection, watering, fertilizing required, and nurturing until the flora are established at the temporary and the final site of relocation.
sum nr
B713
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Preservation of Archeological/Heritage B731 B732 Report [in five sets]. Protection. sum sum
B800 B810.1
ENVIRONMENT REPORT Environmental monitoring report [in five sets on a monthly basis for the TSS content at the discharge outlet of the silt trap/sedimentation basin]. sum
B810.2
Environmental monitoring report [in five sets on a quarterly basis for pH, TSS, BOD, COD, DO, e.coli, ammoniacal nitrogen, and oil and grease, for the discharge point from the project site at Sg. (.)].
sum
B810.3
Environmental monitoring report [in five sets on a quarterly basis for pH, TSS, BOD, COD, DO, e.coli, ammoniacal nitrogen, and oil and grease, for the effluent discharge point at workmen accomodation, workshop and canteen]. Environmental monitoring report [in five sets on a quarterly basis for ambient air quality]. Environmental monitoring report [in five sets on a quarterly basis for noise and vibration measurement].
sum
B810.4
sum
B810.5
sum
B820
Environmental audit report [on a annual basis in five sets]. Environmental closure audit report in [five sets].
sum
B830
sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
C110 C120
Traffic Impact Study Preparation of traffic management plan. Rate to include the cost of any survey required, literature, references, consultations, and the production of the document. It shall also include the cost for the engagement of qualified traffic engineers required for carrying out the respective study and the preparation of the said plan.
sum sum
Traffic Management Team Traffic manager. Traffic management officer. Supervisor. Traffic controller. man-mth man-mth man-mth man-mth
C200
TEMPORARY ROAD FURNITURE Items for temporary road furniture shall be deemed to include the supply, installation, maintenance, and removal upon completion. The supply of temporary road furniture shall be deemed to include base preparation, cost of materials, fabrication, and fixing including posts, struts, bolts and nuts, base, storage, and transportation. Installation of temporary road furniture shall be deemed to include cost for multiple shifting within the contractual boundaries and its vicinities that is affected by the traffic management plan.
Temporary road furniture shall be deemed to include cost for the inspection, immediate repair and replacement of any damaged, missing or stolen items throughout the duration of the construction, and removal upon completion.
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
C211.2
nr
C211.3
nr
C211.4
nr
C212
nr
C213.1
set
C213.2
Traffic signals with [3] optical system mounted on [gantry]as per Specification clause (.). Rate to include signal lanterns, traffic controllers, cabling, and removal upon completion. Barriers and Barricades
set
C221
Heavy duty water- or sand-filled PVC barrier of the [New Jersey] type. [Precast movable reinforced] concrete barrier of the [New Jersey] type. Wooden barricade. Vehicle mounted impact attenuator. Sand bags. Temporary guardrail. Delineators
nr
C222
nr
nr nr m3 m
[750mm] PVC Traffic cones with reflective bands. [Double sided reflective] string delineators. [750 x 600mm] battery operated flashing arrows on powder coated mild steel plate.
nr m nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
C235
nr
m2 m2 nr nr nr
C300 C310
TRAFFIC MANAGEMENT REPORT Traffic management safety report [on a monthly basis in five sets]. Road safety audit report [on a quarterly basis in five sets]. Rate to include the cost of any survey required, literatures, references, consultations, and the production of the document. It shall also include the cost for the engagement of the road safety auditor required for carrying out the audit and the preparation of the said audit report. sum
C320
sum
Page Total carried to Summary of Class C Class C: Traffic Management and Control Page BQC18 of BQC173
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
D200
DEEP BORING Rate to include ground water observation as per Specification clause (...). Plant Movement Shifting of plant and equipment from one borehole position to the next borehole position, rate to include dismantling from one position and erecting at another position where the borehole is to be carried out on:
Flat land. Hillslopes. Floating platform. Fixed platform. Swampy ground. Boring in Soil Carrying out vertical boring in soil using [rotary wash boring equipment (NW size)] for depth measured from Commencing Surface. Rate to include provision of casing where necessary. Water [as drilling fluid]
nr nr nr nr nr
Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m.
m m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
m m m m m m
Not exceeding 10 m. 10 20 m. 20 30 m. 30 40 m. 40 50 m. Exceeding 50 m. Drilling in Rock Carry out vertical diamond core drilling of [52 mm] diameter into rock including storing of core samples in standard boxes. [Core boxes shall become property of the Employer]. Water [as drilling fluid]
m m m m m m
m m m m m m
D232.1
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
D300
CONE PENETRATION TESTS Plant movement Shifting of plant and equipment from one test position to the next test position, rate to include dismantling from one position and erecting at another position where the test is to be carried out on:
Flat land. Hillslopes. Floating platform. Fixed platform. Swampy ground. Page Total carried to Summary of Class D
nr nr nr nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
m m m m m m
m m m m m m
nr nr nr nr nr nr
D331
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Hand Auger Rate for augering in soil shall be deemed to include ground water observation as per Specification clause (). D411 D412 D413 Augering in soil. Disturbed sample [min. 1 kg]. Undisturbed samples using thin wall tube sampler. m nr nr
D414
Water sample [min. 3 litres]. Trial Pit Pit size [2 m wide x 2 m long x 2 m deep]. Rate shall be deemed to include lateral support, logging and mapping of side wall and backfilling, and ground water observation as per Specification clause (). Rate for sampling shall be deemed to include transportation and protection as per Specification clause (..).
nr
Excavation. Small disturbed sample [1 kg]. Bulk sample [min. 50 kg]. Block sample [300 mm x 300 mm]. Water sample [min. 3 litres]. Testing
nr nr nr nr nr
Mackintosh or JKR probes. Vane shear. Plate bearing [300 mm square plate, test pressure 250 kPa with range from uploading and downloading cycle].
m nr nr
D434 D435
nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Sampling Carry out the following sampling at location as indicated in the drawing. Rate for sampling shall be deemed to include transportation and protection as per Specification clause (..).
Small disturbed sample [1 kg]. Bulk sample [min. 50 kg]. Undisturbed samples using thin wall tube sampler.
nr nr nr
D444 D445
nr nr
D500
LABORATORY TESTS All laboratory tests shall be to [BS 1377:1990], unless stated otherwise. Rate to include preparation of specimens. Classification Test
Mositure content. Atterberg limits. Specific gravity. Particle size distribution for fine-grained soils. Particle size distribution for coarse-grained soils. Soil Strength Tests Each set shall consist of 3 nos. of [50 mm diameter x 100 mm length undisturbed] specimen.
nr set nr nr nr
Unconfined compressive strength. Unconsolidated undrained triaxial compression. Consolidated undrained triaxial compression test with pore water pressure measurement. Consolidated drained triaxial compression test with pore water pressure measurement. [60 mm square] direct shear box test.
nr set set
D524
set
D525.1
set
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
D553 D554
nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
D600 D610
INSTRUMENTATION Piezometer as per Specification clause (..) and as shown in the drawings. Rate to include pre-boring and installation. Inclinometer as per Specification clause (..) and as shown in the drawings. Rate to include pre-boring and installation. Settlement surface marker. Settlement plate as per Specification clause (..) and as shown in the drawings. Settlement displacement marker. Magnetic extensometer as per Specification clause (.). Deep levelling datum. Monitoring of instrument for the above instrument at the project site by [Geologist] as per Specification clause (..). Rate to include preparation of monitoring report to be submitted on a [monthly ] basis. nr
D620
nr
D631 D632
nr nr
D633 D640
nr nr
D650 D660
nr nr
D700
D711
Setting out sets of seismic lines, rentising and produce geophone, reduce levels, and topographical profile of each seismic line using EDM.
sum
D712
Carry out seismic refraction survey with a 24-channel seismograph with geophones at intervals of not more than 5 m measured along the slope, and 7 shots per set, using sledge hammer as the seismic energy source. Rate to include data analysis to produce geological profile incorporating borehole data where available.
set
D713
Prepare maps of soil isopach and bedrock contour of the Site as per Specification clause (), based on rock levels obtained from seismic refraction survey.
sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
D722
Carry out [2D] resistivity profiling using [SchlumbergerWenner configuration and roll-along technique with 40 electrodes at 5-meter intervals], each interval measured as the slope distance between adjacent electrodes.
set
D723 D730
Process data for preparation of resistivity profiles. Geological terrain mapping as per Specification clause (.) and in accordance to guidelines by the Minerals and Geoscience Department, Malaysia, covering area as shown in the drawings.
sum m2
Utilities Detection and Mapping D741 Locate, detect, and map all utilities and services as per Specification clause (...), for area as shown in drawings. Verification with utilities provider. Rate to include purchase of necessary documents and verification on the utilities detected as compared with the records of the utilities provider. Conduct site verification. m2
D742
sum
D743
sum
D800
D811
Soil investigation report including laboratory test results as per Specification clause () to be submitted in [two sets] with comb binding.
sum
D812
Seismic refraction survey report as per Specification clause () to be submitted in [two sets] with comb binding. Rate to include geological sections and interpretation of data by specialists.
sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
D814
Geological terrain mapping report as per Specification clause () to be submitted in [two sets] with comb binding. Utilities detection and mapping report as per Specification clause ( ) to be submitted in [two sets] with comb binding. Final Report
sum
D815
sum
D821
Soil investigation report including laboratory test results as per Specification clause () to be submitted in [five sets] in hard cover.
sum
D822
Seismic refraction survey report as per Specification clause () to be submitted in [five sets] in hard cover. Resistivity profiling report as per Specification clause () to be submitted in [five sets] in hard cover.
sum
D823
sum
D824
Geological terrain mapping report as per Specification clause () to be submitted in [five sets] in hard cover. Utilities detection and mapping report as per Specification clause () to be submitted in [five sets] in hard cover.
sum
D825
sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Items for demolition and site clearance shall be deemed to include disposal of the materials arising. E100 GENERAL CLEARANCE Above Ground E110.1 General clearance to [primary forest]. Rate to include the removal of trees and stumps, undergrowth, shrubs, roots, and the likes. [All trees of 0.5 m girth and above shall become the property of the Employer]. ha
E110.2 E120
General clearance to [palm oil estate]. At water bodies. Rate to include removal and disposal of items as per Specification clause (..) in or at [Lake Project] including objects either floating, submerged or at the bed of the the [lake].
ha ha
E200
TREES Felling of trees shall be deemed to include uprooting and removal of stumps. [All trees of 0.5 m girth and above shall become the property of the Employer].
Trees of girth: 0.5 1 m. Trees of girth: 1 2 m. Trees of girth: 2 5 m. Trees of girth exceeding 5 m. [Holes after the removal of stumps shall be filled with granular material].
nr nr nr nr
E300
BUILDING Concrete
E311
Individual building [2-storey bungalow with reinforced concrete walls of total gross built-up area of 2000 m2]. Group of buildings [10 units of single storey chalet with a gross built-up area of 100 m2 each].
sum
E312
sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
E322
sum
Metal E341 Individual buildings [50 m x 10 m steel portal frame factory]. Group of buildings [2 units of 10 m x 6 m steel stores]. sum
E342
sum
No predominant material E351 Individual buildings [single storey reinfoced concrete frame with brick infill and steel roof structure house of total gross builtup area of 300 m2]. sum
E352
Group of buildings [single storey reinfoced concrete frame with brick infill and steel roof structure chalet of gross builtup area of 100 m2 each].
sum
E400
STRUCTURES Concrete
E411
Above ground [10 m long x 6 m wide x 6 m deep mixing chamber]. Below ground [Precast concrete box culverts including headwall, wingwall and foundation 20 m long x 3 m wide x 2 m deep]. Brickwork and Masonry
sum
E412
sum
E421 E422
sum sum
E431
sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
E452
sum
E500
PIPELINES Demolition of pipelines shall be deemed to include demolition and removal of supports. [Dismantle 400 mm DN elevated mild steel pipeline]. The pipeline shall become the property of the Employer and shall be delivered to the store at (.). m
E510
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS F Earthworks
Item No. Code No. F100 EXCAVATION Stripping F111.1 Topsoil of average depth of 150 mm and disposed to the Contractor's dumpsite as approved by the Engineer/S.O./P.D. Topsoil of average depth of 150 mm and stockpile for reuse as top soil for turfing. Cut to Fill Excavation in cut shall be deemed to include trimming and preparation of excavated surface and transportation from source to place of fill or disposal. m2 Description Unit Qty. Rate Amount (RM)
F111.2
m2
F121.1
Excavate in earth material from original ground level [to form embankment]. Excavate in earth material commencing from [104 m] [to form embankment]. Excavate manually in earth material commencing from [104 m] to [103.5 m]. Excavate in natural hard material to form embankment.
m3
F121.2
m3
F121.3
m3
F122
m3
F123.1
Excavate in rock material by open blasting [to form embankment]. Excavate in rock material by controlled blasting [to form embankment]. Excavate in rock material by hydraulic rock breaker [to form embankment]. Excavate in rock material by pneumatic tools [to form embankment]. Cut and Dispose Excavation in cut shall be deemed to include trimming and preparation of excavated surface and transportation from source to place of fill or disposal.
m3
F123.2
m3
F123.3
m3
F123.4
m3
F131.1
Excavate in earth material commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D.
m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS F Earthworks
Item No. Code No. F131.2 Description Excavate in earth material commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D. [Rate to include compaction at disposal site]. Excavate in natural hard material by ripper unit commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D. Excavate in rock by controlled blasting commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D. Excavate in rock by open blasting commencing from [104 m] to [100 m] to disposal site approved by the Engineer/S.O./P.D. Excavate in artificial hard material by hydraulic rock breaker to disposal site approved by the Engineer/S.O./P.D. Excavate in unsuitable material commencing from [104 m] to [103 m] to disposal site approved by the Engineer/S.O./P.D. Foundation Excavation for foundation shall include upholding sides of excavation, preparation of excavated surface, additional excavation to provide working space and removal of dead services. Unit m3 Qty. Rate Amount (RM)
F132
m3
F133.1
m3
F133.2
m3
F134
m3
F135
m3
F141
Excavate in earth material commencing from level [104 m] to [102 m] to [clear water tank]. Excavate in natural hard material using ripper unit commencing from level [104 m] to [102 m] to [raft foundation for chemical building]. Excavate in rock using [hydraulic rock breaker] commencing from level [104 m] to [101 m] to [raft foundation for treated water pumping station]. Excavate in artificial hard material at [TNB sub-station].
m3
F142
m3
F143
m3
F144
m3
F145
Excavate in unsuitable material commencing from level [102 m] to [101 m] at [clear water tank]. Excavate under water at Sg. () from river bed level of [54 m] to [52 m]. Rate shall include all necessary temporary work.
m3
F150
m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS F Earthworks
Item No. Code No. F161 Description Provision of plant and equipment for dredging work at Sg. (.). Rate to include mobilisation and demobilisation. Excavation by dredging at Sg. (..) to limits as shown in Drawing No. (). Rate shall include transportation from source to place of disposal and mopping up of silt which accumulates after the Final Surface has been reached. Unit sum Qty. Rate Amount (RM)
F162
m3
F200
F211
In earth material to temporary stockpile approved by the Engineer/S.O./P.D. In natural hard material to temporary stockpile approved by the Engineer/S.O./P.D. In rock to temporary stockpile approved by the Engineer/S.O./P.D. In artificial hard material to temporary stockpile before final disposal. Timber support left-in. Metal support left-in.
m3
F212
m3
F213
m3
F214
m3
F230 F240
m2 m2
F300
FILLING The following items for filling shall include compaction, and additional filling necessitated by settlement or penetration into underlying material as applicable.
General F311 Using suitable excavated material to grading limits as per Specification clause (). Imported material from Contactor's own source with grading limits as per Specification clause (..). m3
F312.1
m3
F312.2
Imported material from borrow pit as shown in the drawing with grading limits as per Specification clause (..). Grade C20 mass concrete.
m3
F313
m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS F Earthworks
Item No. Code No. F314 Description Other stated material granular material as per Specification clause (..). Embankments F321 Using suitable excavated material to grading limits as per Specification clause () to form embankment. Rate to include formation of benches. m3 Unit m3 Qty. Rate Amount (RM)
F322
Imported material from Contactor's own source with grading limits as per Specification clause (..) to form embankment. Rate to include formation of benches.
m3
F323 F324
Grade C20 mass concrete. Other stated material granular material as per Specification clause (..) to form drainage layer to embankment. Replacement
m3 m3
F331
m3
F332
Replace unsuitable material using imported material from Contactor's own source. Replace excavated unsuitable material with Grade C20 mass concrete. Other stated material granular material as per Specification clause (..) to replace unsuitable material.
m3
F333
m3
F334
m3
F340.1 F340.2
To structures filling around column stumps. To structures filling sides of wall above raft foundation. Filling to embankment at Sg. (.) below water level.
m3 m3
F350
m3
F400 F410
FILLING ANCILLARIES [Continuous polypropylene filament, nonwoven] geotextile with tensile strength of 19 kN/m, effective opening size of 0.09mm and nominal mass of 250 g/m2 as per Specification clause (.). m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS F Earthworks
Item No. Code No. F500 LANDSCAPING Items for landscaping shall be deemed to include digging, planting media, bedding, stalking, protection, watering, weeding, required fertilising, and replacement of dead item until the vegetation is established. Description Unit Qty. Rate Amount (RM)
F510.1 F510.2
Spot turfing to flat areas. Close turfing to slopes. Rate to include pegging down with stakes. Hydroseeding as per Specification clause (.). Hydroseeding with fibromat or equivalent. Bio-degradable erosion control blanket to slope of embankment with fastening hook at [mm] spacing. Rate to include fastening hook and netting.
m2 m2
m2 m2 m2
F540
Vertiver grass or equivalent at 250 mm spacing (in group of 3 rows). Trees of the (.) species with minimum girth of [200 mm] and [3 m] tall.
F550
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS F Earthworks
Item No. Code No. Description Summary of Class F: Earthworks Page BQF1 Page BQF2 Page BQF3 Page BQF4 Page BQF5 Unit Qty. Rate Amount (RM)
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
G120
Moving and handling all necessary plant and equipment within the Site and from location to location as often as is and whenever necessary for the execution of whole operation. Temporary staging.
sum
G130
sum
G200
G211.1
[1.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in the drawings.
m3
G211.2
[2.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in the drawings.
m3
G211.3
[1.0 m x 1.0 m x 1.0 m] rock-filled gabion with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in the drawings. Rate to include for laying underwater. Rock-filled gabion mattress, [300 mm] thick with PVCcoated wire gauge size of [2.7 mm] as per Specification clause (.) and as shown in Drawing No. (....).
m3
G212
m2
G213
Non-woven geotextile as separator as per Specification clause (.). Cribwall Item for cribwall shall be deemed to include precast reinforced concrete (Grade 30) components and granular infill material as per Specification clause (.).
m2
G221
Single cell with [1200 mm] header as shown in Drawing No. (.). Double cell with [1200 mm + 1200 mm] header as shown in Drawing No. (..).
m2
G222
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
G224
m2
G225
Non-woven geotextile as separator as per Specification clause (.). Reinforced Soil Slope
m2
G231
Woven geotextile with minimum long term design strength of [100 kN/m] as soil reinforcement as per Specification clause (.). Geogrid with minimum long term design strength of [75 kN/m] as soil reinforcement as per Specification clause (.). Reinforced earth filling as per Specification clause (.) and as shown in Drawing No. (.). Reinforced granular filling as per Specification clause (.) and as shown in Drawing No. (.). [HDPE] erosion protection mats with minimum tensile strength of [1.4 kN/m] as per Specification clause (.).
m2
G232
m2
G233
m3
G234
m3
G235
m2
Reinforced Soil Wall [Precast reinforced concrete wall facing panels], rate to include galvanised steel soil reinforcement, connections and jointing, geotextile, and accessories for wall joints for wall height:
Not exceeding 6 m. Exceeding 6 m but not exceeding 9 m. Exceeding 9 m but not exceeding 12 m. Exceeding 12 m but not exceeding 15 m. Reinforced earth filling as per Specification clause (.).
m2 m2 m2 m2 m3
G243
Reinforced granular filling as per Specification clause (.). [350 mm wide x 150 mm thick G20 mass concrete] leveling pad.
m3
G244
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
G300
SLOPE STABILISATION Soil Nailing Rate for soil nailing shall be deemed to include drilling of borehole, corrugated HDPE pipe if applicable, sleeve grouting, sealant compound, galvanised steel bearing plate, and all necessary formwork.
[100 mm dia.] soil nail with [T25] reinforcement bar as shown in Drawing No. (....). G311.1 G311.2 G311.3 [6 m] long. [9 m] long. [12 m] long. Pull out test on soil nail, rate to include all necessary equipment and submission of procedure, records, and report. G312.1 G312.2 G312.2 To [1.5] times the working load of 50 kN. To [1.5] times the working load of 75 kN. To [1.5] times the working load of 100 kN. Rock Bolt Rate for rock bolt shall be deemed to include drilling of borehole, reinforcement bar, reinforced concrete pad, sleeve grouting, sealant compound, and all necessary formwork. Type A with T32 bolt as shown in Drawing No. (.). nr nr nr nr nr nr
[2 m] long. [4 m] long. Pull out test on rock bolt as specified, rate to include all necessary equipment and submission of procedure, records, and report.
nr nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
In earth. In natural hard material. In rock. Pull out test on ground anchor as per Specification clause (.), rate to include all necessary equipment and submission of procedure, records, and report.
m m m nr
Concrete Buttress Rate for concrete buttress shall be deemed to included steel fabric mesh, PVC drain pipe, dowel bars, filter material, and all necessary formworks.
G340.1
[G25] concrete buttress with average thickness [not exceeding 300 mm]. [G25] concrete buttress with average thickness [exceeding 300 mm but not exceeding 400 mm]. Horizontal Drain Rate for horizontal drain shall be deemed to include drilling and perforated pipe. [100 mm] diameter uPVC horizontal drain as shown in Drawing No. (.).
m2
G340.2
m2
G351 G352
In earth. In rock.
m m
G400 G410
SURFACE PROTECTION [100 mm] thick [G25] guniting. Rate shall be deemed to include steel fabric mesh, PVC drain pipe, dowel bar, and filter material as shown in Drawing No. (.). m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
G430
m2
G440
m2
G450
m2
G500 G510
GROUND TREATMENT [100 mm x 3 mm] prefabricated vertical drains as per Specification clause (). Dynamic compaction using [10 tonne] drop hammer with [five] drops at height of 15 m. Vibro compaction up to depth of [10 m] as per Drawing No (.) 1000 mm diameter sand column as per Specification clause (.). 1000 mm diameter aggregate column as per Specification (.). 1000 mm diameter stone column as per Specification (.). 1000 mm diameter cement column as per Specification (.). m
G520
nr
G530
nr
G540
G550
G560
G570
G600
GROUTING WORK Drilling for [50 mm] diameter grout holes for depth not exceeding [10 m] in:
G611 G612
Earth. Rock; rate to include drilling in natural and artificial hard material. uPVC sleeve pipes for [50 mm] diameter grout hole. Rate to include grouting of annulus space between the sleeve pipe and the drill holes.
m m
G620
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Ascending stage with single packer setting. Descending stage with double packer setting. Water pressure test as per Specification clause (.).
nr nr nr
G700
DIAPHGRAGM WALLS Excavation Excavation for [1.2 m] thick diaphragm wall not exceeding depth 15 m for the following. Rate to include preparation and upholding sides of excavation.
Earth. Natural hard material. Rock. Artificial hard material. [Grade C40] tremie mix concrete. Reinforcement, Rate To Include Labour for Cutting, Bending and Placing Mild steel bar reinforcement
m3 m3 m3 m3 m3
G731.1 G731.2
Nominal diameter: [10 mm]. Nominal diameter: [12 mm]. High tensile steel bar reinforcement
t t
G732.1 G732.2
t t
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
G770
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
H120
Moving and handling of all piling plant and equipment within the Site and from location to location as often as is, and whenever necessary for the execution of the whole piling operation. Temporary staging [for piling work at the banks of Sg. (..)].
sum
H130
sum
H200
PILES Items for piling work shall be deemed to include piling records and disposal of excavated and surplus materials.
Bored Piles Items for bored piles shall be deemed to include temporary casings, stabilising agent, and enlarged bases.
[900 mm] diameter bored piles as working piles. H211.1 Boring in earth, up to [20 m] for [50] nos. of pile points. m
H211.2
Boring in earth, raked at inclination of ratio [1:5] for [10] nos. of pile points. Boring through rock, up to [10 m] for [50] nos. of pile points. Rate to include natural and artificial hard material. Boring through rock and raked at inclination ratio of [1:6] for [10] nos. of pile points. Rate to include natural and artificial hard material. [12 mm] thick mild steel permanent casings. Rate to include the supply and jointing of casings, driving heads, and shoes. High tensile reinforcement straight bars, nominal diameter not exceeding 20 mm. Rate to include supporting reinforcement.
H212.1
H212.2
H213
H214
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
H216
H217 H218
m nr
H222
Boring through rock. Rate to include natural and artificial hard material. Reinforcement straight bars nominal diameter:
H224
High tensile reinforcement straight bars, nominal diameter not exceeding 20mm. Rate to include supporting reinforcement. High tensile reinforcement straight bars, nominal diameter exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement 12 mm diameter helical bars. Rate to include supporting reinforcement.
H225
H226
H227 H228
Concreted length with grade [40/20]. Cut-off piles. Rate to include preparing heads. Caisson Piles [2500 mm] diameter caisson piles as working piles.
m nr
H231
Excavate in earth, up to [20 m] for [25] nos. of pile points. Excavate through rock, up to [10 m] for [25] nos. of pile points. Rate to include natural and artificial hard material. [20 mm] thick mild steel permanent casings. Rate to include the supply and jointing of casings, driving heads, and shoes.
H232
H233
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
H235
H236
H237
H242
Boring through rock, up to [10 m] for [30] nos. of pile points. Rate to include natural and artificial hard material. Supply and install [127 mm OD x 9 mm thick Grade N80 API pipe]. High tensile reinforcement straight bars, nominal diameter not exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement straight bars, nominal diameter exceeding 20 mm. Rate to include supporting reinforcement. High tensile reinforcement helical bars. Rate to include supporting reinforcement. Grouting with non-shrink cement grout Grade [C30] as specified into drilled hole. Rate shall include excess cement required when the grout volume exceeded the theoretical volume. Cut-off piles. Rate to include preparing heads. Precast Reinforced Concrete Piles [200 mm] G40 square precast reinforced concrete piles with a working load of [.] kN.
H243
H244
H245
H246
H247
m3
H248
nr
H251.1
nr
H251.2
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
H254
nr
H256
nr
Supply extension pile of [9 m] length. Depth driven. Depth driven raked at inclination ratio of [1:6]. Depth driven using jack-in method. Pre-boring, [18.0 m] depth. Rate to include backfilling between the pile and the bore. Jointing with butt weld all round as shown in Drawing No. (.). Filling hollow piles with concrete grade [C30]. Rate to include removal of materials from within the piles before concreting. Cut-off piles. Rate to include preparing heads. Steel H-Piles 533 mm x 210 mm x 138 kg/m UB Grade 43A.
nr m m m m
H264
nr
H265
H266
nr
H271
Supply of steel H-piles with metal-filled primers of [6 m] length. Rate to include cathodic protection using the impressed current system as per Specification clause (..). Depth driven. Depth driven raked at inclination ratio of [1:6]. Depth driven using jack-in method.
nr
m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
H274
nr
m m m nr
H284 H300
nr
H314
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Supply in [12 m] length. Depth driven. Special piles for 90o corners with mass of 14.4 kg/m.
m m2 m
H334 H335
Cut-off piles. Rate to include preparing heads. 305 mm x 165 mm x 54 kg/m Grade 43A universal beam as waling. Rate to include supply and installation.
m m
H336
nr
H400
H411
H500 H510.1
PILE TESTS Initial static load test on 900 mm diameter bored pile up to two times working load of 16,000 kN. Subsequent static load test, on 900 mm diameter bored pile up to two times working load of 16,000 kN (Test load of 32,000 kN). Static load test on preliminary 300 mm diameter precast prestressed concrete pile to failure (Test load of .kN). nr
H510.2
nr
H510.3
nr
H520
PDA test on [300 mm] diameter prestressed concrete pile. Pile integrity test (sonic echo test) on [300 mm] diameter prestressed concrete pile. Sonic logging test on 900 mm diameter bored piles as per Specification clause (.). Lateral test on [300 mm] diameter prestressed concrete pile. Statnamic test on [300 mm] diameter prestressed concrete pile. Page Total carried to Summary of Class H
nr
H530
nr
H540
nr
H550
nr
H560
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Grade C15 Concrete I111.1 I111.2 Mass concrete blinding, [50 mm] thick [to footing]. Mass concrete blinding, [50 mm] thick [to raft foundation]. Mass concrete benching to sumps. Grade: C20 I121 Mass concrete blinding, [75 mm] thick [to clear water tank]. Mass concrete benching to sumps. Mass concrete benching to trenches. Mass concrete surround to pipes. Mass concrete screed to fall for roof. Grade: C25 I132.1 I132.2 I132.3 I132.4 I133 I134 I135 I136 Reinforced concrete to base of [valve chamber]. Reinforced concrete to footing of [guard house]. Reinforced concrete to pile caps of [workshop]. Reinforced concrete to ground slab to [store]. Reinforced concrete to olumns of [guard house]. Reinforced concrete beams to [workshop]. Reinforced concrete to walls of [valve chambers]. Reinforced concrete to suspended slabs [at first floor of workshop]. Other concrete forms, reinforced concrete to [steps and staircase]. m3 m3 m3 m3 m3 m3 m3 m3 m2 m2 m2
I112
m3
m3 m3 m3 m3
I137
m3
Page Total carried to Summary of Class I Class I: Concrete Work Page BQI59 of BQI173
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
m3 m3 m3
I144
m3
I145 I146
m3 m3
I147
m3
Reinforced concrete pile caps. Reinforced concrete ground slabs. Reinforced concrete to columns for [Chlorine Building].
m3 m3 m3
I153.2
m3
Reinforced concrete beams to [pedestrian bridge]. Reinforced concrete walls to [bridge abutment]. Reinforced concrete suspended slabs to [bridge deck].
m3 m3 m3
I157
m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I164
m3
I165 I166
Reinforced concrete walls to [clear water tank]. Reinforced concrete suspended [flat] slabs to [roof of clear water tank]. Other concrete forms mass concrete benching to [washwater channel]. Grade: C40
m3 m3
I167
m3
I172.1 I172.2 I172.3 I172.4 I173.1 I173.2 I174 I175 I176 I177
Reinforced concrete bases. Reinforced concrete footings. Reinforced concrete pile caps. Reinforced concrete ground slabs. Reinforced concrete columns. Reinforced concrete piers. Reinforced concrete beams. Reinforced concrete walls. Reinforced concrete suspended slabs. Other concrete forms. Grade: C50
m3 m3 m3 m3 m3 m3 m3 m3 m3 m3
Reinforced concrete bases. Reinforced concrete footings. Reinforced concrete pile caps. Reinforced concrete ground slabs. Reinforced concrete columns. Reinforced concrete piers.
m3 m3 m3 m3 m3 m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I200
IN SITU CONCRETE PRESCRIBED MIX Rate for in situ concrete prescribed mix shall be deemed to include placing and compaction of concrete.
1:3:6 I211 I212 Mass concrete blinding, [50 mm] thick [to footing]. Mass concrete benching to sumps. 1:2:4 I221 Mass concrete blinding, [75 mm] thick [to clear water tank]. Mass concrete benching to sumps. Mass concrete benching to trenches. Mass concrete surround to pipes. Mass concrete screed to fall for roof. Reinforced concrete columns. Reinforced concrete beams. Reinforced concrete walls. Reinforced concrete suspended slabs. Other concrete forms. 1:1.5:3 I232.1 I232.2 Reinforced concrete base to [trenches]. Reinforced concrete footings to [Administration Building]. Reinforced concrete pile caps to [Workshop]. Reinforced concrete ground slab to [Workshop]. m3 m3 m2 m2 m3
m3 m3 m3 m3 m3 m3 m3 m3 m3
I232.3 I232.4
m3 m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I234
m3
I235 I236
m3 m3
I237
m3
I242.2
m3
Reinforced concrete pile caps. Reinforced concrete ground slabs. Reinforced concrete to columns for [Chlorine Building].
m3 m3 m3
I244
m3
I245 I246
Reinforced concrete walls to [bridge abutment]. Reinforced concrete suspended slabs to [bridge deck].
m3 m3
I247
m3
I300
PRECAST CONCRETE Item for precast concrete shall be deemed to include reinforcement, formwork, joints, and finishes; and items for prestressed precast units shall include prestressing.
I310.1
[Grade C35] [400 mm x 300 mm x 4 m long] columns to first floor. [Grade C45] columns with dimension as shown in Drawing No. () to mezzanine floor.
nr
I310.2
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I330
nr
I340
[Grade 45] Prestressed post-tensioned main beam,[ Tsection 800 mm x 1400 mm x 22 m long] as per Drawing No. (..) and Specification clause ().
nr
I350
[Grade 35], 6 m x 3 m x 150 mm thick walls to the first floor up to the fourth floor. [Grade 35] [half] slab, [3 m x 2 m x 75 mm thick] to the first floor. Segmental units with dimensions as shown in Drawing No. () Units for subways and vehicular or pedestrian culverts and ducts with dimensions as shown in Drawing No. (.)
nr
I360
nr
I370
nr
I380
I400
FORMWORK Rate for formwork shall be deemed to include the projections and intrusions and any temporary staging required. Sides
I411.1 I411.2 I411.3 I411.4 I412.1 I412.2 I412.3 I412.4 I413.1 I413.2 I414.1
F1: rough finish to bases. F1: rough finish to footings. F1: rough finish to pile caps. F1: rough finish to ground slabs. F2: fair finish to columns. F2: fair finish to piers. F3: smooth finish to columns. F3: smooth finish to piers. F2: fair finish to beams. F3: smooth finish to beams. F2: fair finish to walls.
m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I442 I444
m2 m2
I500
REINFORCEMENT Rate for reinforcement shall be deemed to include labour for cutting, bending, and placing. Mild Steel Bars
Nominal diameter: 6 mm. Nominal diameter: 10 mm. Nominal diameter: 12 mm. Nominal diameter: 16 mm. Nominal diameter: 20 mm. Nominal diameter: 25 mm. Nominal diameter: 32 mm.
t t t t t t t
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I540.2
nr
I550.1
m2
I550.2
m2
I550.3
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I550.5
High tensile steel fabric mesh A393 (A10), 6.16 kg/m2. High tensile steel fabric mesh B196 (B5), 3.05 kg/m2.
m2
I550.6
m2
I550.7
m2
I550.8
m2
I550.9
m2
I550.10
High tensile steel fabric mesh B785 (B10), 8.14 kg/m2. High tensile steel fabric mesh B1131 (B12), 10.90 kg/m2. High tensile steel fabric mesh C283 (C6), 2.61 kg/m2.
m2
I550.11
m2
I550.12
m2
I550.13
m2
I550.14
m2
I550.15
m2
I550.16
High tensile steel fabric mesh C785 (C10), 6.72 kg/m2. Fabric of other stated material.
m2
I560
m2
I600
CONCRETE ANCILLARIES Joints Rate for joints shall be deemed to include formwork.
I611 I612
Construction joint, [150 mm wide]. Contraction joints, [200 mm wide]. [Rate to include surface of joint with two coats of polyether paint].
m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I614.1
I614.2
I615.1
I615.2
I616
Dowels plain, [25 mm diameter x 300 mm long] steel bars at [600 mm] centres. Dowels sleeved and capped, [25 mm diameter x 300 mm long] steel bars at [600 mm] centres. Post-Tensioned Prestressing Rate for prestressing shall be deemed to include ducts, jacking, grouting, and other components and tasks ancillary to prestressing.
nr
I617
nr
I621
Horizontal internal tendons in in situ concrete, [seven] wire standard strand to BS 5896, Class 1; [nominal diameter 12 mm]; concrete cone anchors to BS 1477, [7 10] length for Beam No. [2]. Inclined internal tendons in in situ concrete, [seven] wire standard strand to BS 5896, Class 1; [nominal diameter 12 mm]; concrete cone anchors to BS 1477, [7 10] length for Beam No. [2].
nr
I622
nr
I623
Horizontal internal tendons in precast concrete, [seven] wire standard strand to BS 5896, Class 1; [nominal diameter 12 mm]; concrete cone anchors to BS 1477, [7 10] length for Beam No. [2]. Inclined internal tendons in precast concrete, [seven] wire standard strand to BS 5896, Class 1; [nominal diameter 12 mm]; concrete cone anchors to BS 1477, [7 10] length for Beam No. [2]. Finishing of Top Surfaces Rate for finishing of top surfaces shall be deemed to include wood float or steel trowel.
nr
I624
nr
I631
Power float.
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I652.2
nr
I652.3
nr
I652.4
nr
I660
nr
I700
ANCILLARY WORK FOR WATER RETAINING STRUCTURE Water proofing admixtures using [XYPEX] or equivalent to be in mix proportion as recommended by the manufacturer. Water tightness testing of [1000 m3 clear water] tanks. Rate to include provision of water and all testing equipment as per Specification clause (..). m3
I710
I720
m3
I730
Sterilizing and flushing of [1000 m3 clear water] tank. Rate to include provision of potable water and chemicals as per Specification clause (..). Linings and Coatings Rate for linings and coatings shall be deemed to include supply and installation/application.
m3
I741
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
I743
m2
I744
m2
I745
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
J111.2
m2
J111.3
m2
J111.4
m2
J111.5
m2
J121.1
[115 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical curved walls. [230 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for vertical curved walls. [Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for battered straight walls, average thickness of [172.5 mm], varying from 230 mm to 115 mm. [Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for battered curved walls, average thickness of [172.5 mm], varying from [230 mm to 115 mm]. [115 mm] thick [common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar as vertical facing to concrete. [Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for battered facing to concrete, average thickness of [172.5 mm], varying from [230 mm to 115 mm].
m2
J121.2
m2
J131
m2
J141
m2
J151
m2
J161
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
J180.1
m3
J180.2
[Common brickwork] laid in stretcher bond, jointed in [1:3] cement mortar for [600 mm x 600 mm] piers.
m3
J200
BLOCKWORK
Item for blockwork shall be deemed to include joint reinforcement, movement joints, fixing ties, bonds to existing work, and fixing clamps.
J211
[115 mm] thick lightweight blockwork laid in stretcher bond and jointed in [1:3] cement mortar for vertical straight walls. [115 mm] thick lightweight blockwork laid in stretcher bond and jointed in [1:3] cement mortar for vertical curved walls. [115 mm] thick lightweight blockwork laid in stretcher bond and jointed in [1:3] cement mortar as vertical facing to concrete. [115 mm] thick lightweight blockwork laid in stretcher bond and jointed in [1:3] cement mortar for casing to metal sections. [Lightweight blockwork] laid in stretcher bond, jointed in [1:3] cement mortar for [600 mm x 600 mm] column.
m2
J221
m2
J251
m2
J271
m2
J280.1
m3
J280.2
[Lightweight blockwork] laid in stretcher bond, jointed in [1:3] cement mortar for [600 mm x 600 mm] piers.
m3
J300
MASONRY Item for masonry shall be deemed to include fair face finish.
J311
[300 mm] thick natural stone masonry jointed in [1:3] cement mortar flush pointed for vertical straight walls.
m2
J321
[300 mm] thick natural stone masonry jointed in [1:3] cement mortar flush pointed for vertical curved walls.
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
J342
m2
J351
m2
J361
m2
J371
m2
J380.1
Natural stone masonry jointed in [1:3] cement mortar flush pointed for [600 mm x 600 mm] column.
m3
J380.2
Natural stone masonry jointed in [1:3] cement mortar flush pointed for [600 mm x 600 mm] piers.
m3
J400
Brick on edge coping. Bullnosed copings. Rounded copings as shown in Drawing No. (). Special sills as shown in Drawing No. (). [100 mm] deep rebates in brickwall. Decorative cornices as shown in Drawing No. (.).
m m m m m m
J414
Band courses for brickwall as shown in Drawing No. (..). Bullnose corbel as shown in Drawing No. (.).
J415
J416
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Concrete Grade C20 infills of 50 mm thick. Built-in 150 mm DN uPVC drainage pipes. Built-in 50 mm DN uPVC cable ducts.
m2 nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
K111.2
K112
K121.2
K122.1
K122.2
K131.2
K132.1
K132.2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
K142
[150 mm x 75 mm damar minyak ], kiln dry as per Specification clause (.) to [girders, ..]; length exceeding 6 m.
K200
DECKING AND BOARDING Rate for decking and boarding shall be deemed to include framework where expressly required; walls and soffits shall include for any temporary staging required. Grade A Heavy Hardwood; Wrot Finish
K211
[150 mm wide x 32 mm thick balau ] floor deck boards. [100 mm wide x 12 mm thick balau ] panelling to wall. [Rate to include 50 mm x 50 mm balau studs at 600 mm centres as framework].
m2
K212.1
m2
K212.2
[150 mm wide x 40 mm thick cengal ] baffle wall to flocculation tanks. [100 mm wide x 12 mm thick balau ] panelling to ceiling. [Rate to include 50 mm x 50 mm balau studs at 600 mm centres as framework].
m2
K213
m2
Grade B Medium Hardwood; Wrot Finish K221 [150 mm wide x 32 mm thick kempas ] with [preservative treatment] as per Specification clause (.) to floor deck. [100 mm wide x 12 mm thick keruing ] with [peservative treatment to Specification clause (..)] to wall panelling. [Rate to include 50 mm x 50 mm keruing studs at 600 mm centres as framework]. m2
K222
m2
K223
[100 mm wide x 12 mm thick keruing ] with [peservative treatment to Specification clause (..)] for panelling to ceiling. [Rate to include 50 mm x 50 mm balau studs at 600 mm centres as framework].
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
K232
m2
K233
[100 mm wide x 12 mm thick nyatoh ] with [peservative treatment to Specification clause (..)] for panelling to ceiling. [Rate to include 50 mm x 50 mm balau studs at 600 mm centres as framework].
m2
Grade D Softwood; Wrot Finish K241.1 [150 mm wide x 12 mm thick damar minyak ], [kiln dry as per Specification clause (.) to floor deck]. m2
K241.2
[150 mm wide x 12 mm thick sempilor ], [kiln dry as per Specification clause (.) to floor deck. [Rate to include 75 mm x 50 mm sempilor floor joists at 600 mm centres]. [100 mm wide x 12 mm thick damar minyak ], kiln dry as per Specification clause (..)] to wall panelling. [Rate to include 50 mm x 50 mm damar minyak studs at 600 mm centres as framework].
m2
K242
m2
K243
[100 mm wide x 12 mm thick nyatoh ], kiln dry as per Specification clause (..)] for panelling to ceiling. [Rate to include 50 mm x 50 mm damar minyak studs at 600 mm centres as framework].
m2
K300
K311
[100 mm high x 12 mm thick chengal ] wall skirting to [floor]. [Cengal ] hand rails with 75 mm x 75 mm post and 75 mm x 50 mm rails as shown in Drawing No. ().
K312
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
K314
K322
[Kempas ] hand rails with 75 mm x 75 mm post and 75 mm x 50 mm rails as shown in Drawing No. (). Timber to be treated with preservatives as per Specification clause (.).
K323
[100 mm high x 50 mm wide kempas] cornice to ceiling with profile as shown in Drawing No. (.). Timber to be treated with preservatives as per Specification clause (.).
K324
[50 mm wide x 25 mm high kempas] dado with profile as shown in Drawing No. (.) to be fixed at [1.2 m] from the finished floor level. Timber to be treated with preservatives as per Specification clause (.). Grade C Light Hardwood; Wrot Finish
K331
[100 mm high x 12 mm thick nyatoh ] wall skirting to [floor]. Timber to be treated with preservatives as per Specification clause (.).
K332
[Nyatoh ] hand rails with 75 mm x 75 mm post and 75 mm x 50 mm rails as shown in Drawing No. (). Timber to be treated with preservatives as per Specification clause (.).
K333
[100 mm high x 50 mm wide nyatoh] cornice to ceiling with profile as shown in Drawing No. (.). Timber to be treated with preservatives as per Specification clause (.).
K334
[50 mm wide x 25 mm high nyatoh] dado with profile as shown in Drawing No. (.) to be fixed at [1.2 m] from the finished floor level. Timber to be treated with preservatives as per Specification clause (.). Page Total carried to Summary of Class K
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
K342
K343
K344
[50 mm wide x 25 mm high damar minyak] dado with profile as shown in Drawing No. (.) to be fixed at [1.2 m] from the finished floor level. Timber to be treated with preservatives as per Specification clause (.).
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Supply and erection of structural members for frames; steel to [BS:4360]. Hot-Rolled Sections L111 [457 mm x 191 mm x 98 kg/m] mild steel universal column to [Grade 43A, BS 4360]. [457 mm x 152 mm x 82 kg/m] mild steel universal beam to [Grade 43A, BS 4360]. [406 mm x 146 mm x 32.74 kg/m] universal beam as portal frame as shown in Drawing No. (.). 15 m span mild steel truss, Grade 43A: BS 4360 for 250 mm DN pipe stream crossing as shown in Drawing No. (.). L114.1 L114.2 L114.3 L114.4 L115 203 mm x 102 mm x 23 kg/m universal beam. 150 x 75 x 10 mm thick x 17 kg/m angle. 80 x 80 x 8 mm thick x 9.63 kg/m angle. 60 x 60 x 6 mm thick x 5.42 kg/m angle. 12.5 mm thick x 103.1 kg/m2 Grade 43A mild steel chequred plates to BS 4360 as decking. [200 x 68 x 16 mm thick x 4.75 kg/m C-channel as wall bracings. [305 mm x 165 mm x 54 kg/m] universal beam at 800 mm centres as grillages. Cold-Rolled Sections L121 L122 [150 x 150 x 5 mm thick] box section as column. [200 x 100 x 5 mm thick] C-section as wall framing. t t t t t t t t
L112
L113
L116
L117
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
L126
Built-up or Fabricated Sections L131 [600 mm x 600 mm] built-up column comprising 20 mm thick steel plates as shown in Drawing No. (.). t
L132
L133
Pre-engineered steel portal frame as shown in Drawing No. (.). Extruded Sections
L141
[76.1mm OD x 3.2mm thick x 5.75 kg/m] circular hollw section to [wall]. [50 x 30 x 2.6mm thick x 3.03 kg/m] rectangular hollow section to [wall] [48.3 mm OD x 3.2 mm thick x 3.56 kg/m] circular hollow section to frame as shown in Drawing No. (.).
L142
L144
L146
[200 x 68 x 16 mm x 4.75 kg/m] C-channel as wall bracings. Rate for black bolts shall be deemed to nuts, washers, gusset and end plates, and other accessories.
Black Bolts L151 L152 L153 L154 L155 L156 L157 L158 Nominal diameter: 16 20 mm. Nominal diameter: 20 24 mm. Nominal diameter: 24 30 mm. Nominal diameter: 30 36 mm. Nominal diameter: 36 42 mm. Nominal diameter: 42 48 mm. Nominal diameter: 48 56 mm. Nominal diameter of [60 mm]. nr nr nr nr nr nr nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
L162
nr
L163
nr
L164
nr
L165
nr
L166
nr
L167
nr
L168
nr
L200
MISCELLANEOUS METALWORK Item for miscellaneous metalwork shall be deemed to include fixing to other work, supply of fixing components, and drilling or cutting of other work.
L210
Stairways and landings; [150 mm riser with 250 mm treads] as per Drawing No. (..). [2 m] wide walkways as per Drawing No. (.). Galvanised mild steel ladders; [70 x 70 x 10 mm thick x 10.3 kg/m stringer 400 mm] apart, with [20 mm] diameter steel rungs at [300 mm] centres. Rate to include full assemblies.
nr
L220 L230
m2 m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
L240
Galvanised mild steel handrail of 42.4 mm diameter tubular section of 3.2 mm thickness and 1100 mm high with fixing accessories as shown on the drawing.
L250
114.3 mm OD x 5.0 mm thick x 13.5 kg/m circular hollow section as parapets. Rate to include full assemblies. Decking Rate for decking shall be deemed to include supporting metalwork as framework.
L261
[8 mm] thick galvanised mild steel chequered plates trench covers. Galvanised mild steel open mesh cover complete with 50 mm x 50 mm x 5.82 kg/m angle frame built-in into the floor inclusive of RHS as supports. Welded mesh paneling. [6 mm] thick galvanised mild steel chequered plates flooring. [Colourbond metal deck, 0.48 mm] base steel thickness to wall cladding. 305 mm x 165 mm x 54 kg/m mild steel Grade 43A universal beam as waling.
m2
L262
m2
L263 L264
m2 m2
L270
m2
L280
L300
L311 L312
[50 x 50 x 5 mm thick x 3.77 kg/m] angle section. [102 mm x 51 mm x 10.42 kg/m] C-channel section.
m m
L313 L314
[152 mm x 89 mm x 17.09 kg/m] I-section. [100 x 50 x 3.2 mm thick x 7.18 kg/m] rectangular hollow section. Tanks
m m
L321
Uncovered metal steel tanks; capacity: [2140] litres; dimension: [3000 L x 1670 H x 465 W] as per Specification and as shown in the drawings. Covered stainless steel water tank; capacity: [1000] litres; grade [304]; dimension [1060 dia. x 1060 H] as per Specification and as shown in the drawings.
nr
L322
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M111.2
M111.3
M112
m2
Metal Roof Structure Rate to include connecting plates, bolts, nuts, all welding, and other fastening system. M113.1 [457 mm x 191 mm x 98 kg/m] mild steel universal column. [Grade 43A to BS 4360] as rafter as shown in Drawing No. (.). [75 x 75 x 4 mm thick x 8.60 kg/m] mild steel square hollow section, [Grade 43A to BS 4360] as top chord member as shown in Drawing No. (.). kg
M113.2
kg
M113.3
[150 x 75 x 4 mm thick x 18.60 kg/m] C-channel purlins. [Grade 43A to BS 4360] as shown in Drawing No. (.). [200 x 68 x 2 mm] thick cold formed galvanised mild steel C-channel as purlins. Mild steel, Grade 43A to BS 4360 roof truss system and components to be designed by Contractor as per Specification clause (.). Rate to include connecting plates, bolts, nuts, all welding, and other fastening system. Galvanised mild steel roof truss system and components using cold-rolled steel to be designed by Contractor as per Specification clause (.). Rate to include connecting plates, bolts, nuts, all welding, and other fastening system.
kg
M113.4
kg
M114.1
m2
M114.2
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M121.2
m2
M122
m2
M123
m2
M132
m2
M142
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Description
Unit
Qty.
Rate
Amount (RM)
m m m m
m nr nr nr
M161.2
M162.1
M162.2
M163
[2 m x 1 m x 6 mm thick] polycarbonate skylight as per Specification clause (.). [2 m x 1 m x 6 mm thick corrugated transparent sheet] as per Specification clause (.). [6 mm thick corrugated] ventilator sheet.
nr
M164
nr
M165
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M173
Mitred vertical angle tiles (coloured) to match interlocking tiles. Ridge capping [500 mm girth]. Hip capping [500 mm girth]. Vertical angle tiles (coloured) to match interlocking tiles. Saddle (coloured) to match interlocking tiles. Glass tiles to match interlocking tiles. Gutters and Downpipes Rate for gutters and downpipes to include fixing and supply of fixing components.
m m m
M176 M177
nr nr
[150 mm half round uPVC] rainwater gutters. [150 mm half round uPVC] elbow for gutters. [100 diameter uPVC] rain water down pipes. [100 diameter uPVC] elbow for rain water down pipes.
m nr m nr
M200
WATER PROOFING Rate for water proofing to include preparing surfaces, forming joints, overlaps, mitres, angles, fillets, built-up edges, and laying to falls or cambers. Asphalt
M211
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M213
m2
M214
M215
nr
M216
nr
M222
m2
M223
m2
M224
M225
nr
M226
[One layer of 6 mm thick bituminous lining] to sides of concrete gutter. Sheet Metal
nr
M231
[One layer of 0.5 mm thick zinc sheet] laid on sloping timber boarding roof. [One layer of 0.5 mm thick zinc sheet] laid on horizontal timber boarding roof. [One layer of 0.5 mm thick zinc sheet] laid on vertical surface area. [One layer of 0.5 mm thick zinc sheet] laid on timber surfaces of width not exceeding 300 mm. [One layer of 0.5 mm thick zinc sheet] laid on isolated group of surfaces not exceeding 1 m2.
m2
M232
m2
M233
m2
M234
M235
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M242
m2
M243
m2
M244
M245
nr
M246
nr
M252
m2
M253
m2
M254
M255
nr
M256
nr
M262
m2
M263
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M265
[One layer of 25 mm thick 1:3 cement sand mortar] laid on isolated group of surfaces not exceeding 1 m2.
nr
M266
[One layer of 25 mm thick 1:3 cement sand mortar] at rainwater outlet. Rendering in Water Proof Cement Mortar
nr
M271
[One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid on sloping surface area. [One layer of 25 mm thick 1:3 cement sand mortar with waterprofing agent] as per Specification clause (.) laid on horizontal surface area. [One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid on vertical surface area. [One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid on surface of width not exceeding 300 mm. [One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid on isolated group of surfaces not exceeding 1 m2.
m2
M272
m2
M273
m2
M274
M275
nr
M276
[One layer of 25 mm thick 1:3 cement sand mortar with waterproofing agent] as per Specification clause (.) laid rainwater outlet. Sprayed or Brushed Waterproofing
nr
M281
[One layer of 2 mm thick waterproofing material as per manufacturer's instruction] sprayed on sloping surface area. [One layer of 2 mm thick waterproofing material as per manufacturer's instruction] sprayed on horizontal surface area. [One layer of 2 mm thick waterproofing material as per manufacturer's instruction] sprayed on vertical surface area. [One layer of 2 mm thick waterproofing material as per manufacturer's instruction sprayed concrete gutter (measured separately) not exceeding 300 mm wide].
m2
M282
m2
M283
m2
M284
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M286
nr
M300
WINDOWS AND DOORS Rate for windows and doors to include fixing, supply of fixing components, drilling or cutting of associated work, and all associated glazing work. Timber
M312
[Grade A] timber windows; [1200 mm x 1200 mm] fitted with standard sill and complete with 6 mm thick float glass louvres and 10 mm security bar as shown in Drawing No. (). [Grade A, 2100 mm x 900 mm] timber doors frames as shown in Drawing No. (.). Single leaf solid [Grade A] timber door type (.] as shown in Drawing No. (.). Double leaf solid [Grade A] timber door type (.] as shown in Drawing No. (.). [Two-hour rated fire resistant] double leaf solid timber door type (..) as per Specification clause (.).
nr
M313
nr
M314.1
nr
M314.2
nr
M315
nr
All ironmongery to include necessary fixing screws. M317.1 M317.2 Pair of stainless steel hinges; [75 mm x 50 mm]. Pair of stainless steel butt hinges; [100 mm x 75 mm]. nr nr
M317.3
["Mobel C3600-70-SS-Ent-HOM" ] cyclindrical knobset with stainless steel finish. ["St Guchi D264-70-SS-HOM"] half deadbolt. ["Dorma"] door closers, [140 mm x 22 mm]. Supply and fix anti-vermin netting on outside to window.
nr
nr nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M322
nr
M323
nr
M324
Natural anodised aluminium door complete with 6 mm thick clear glass as showin in the drawings [Size: 900 mm x 2100 mm]. Natural anodised motorised aluminium roller shutter door complete with rollers, guide, pelmet, and locks; [4000 mm x 3500 mm] as shown in Drawing No. (..).
nr
M326
nr
Plastics M334 M337.1 M337.2 PVC doors; 32 mm thick; [2100 mm x 900 mm]. Pair of stainless steel hinges; [75 mm x 50 mm]. ["St Guchi D264-70-SS-HOM"] half deadbolt. nr nr nr
GLAZING 6 mm clear float glass, fixed with putty. 10 mm tinted glass, fixed with putty. [3000 x 2000 x 10 mm thick] clear float glass panel to be fixed with silicone. [3000 x 2000 x 10 mm thick] laminated glass panel to be fixed with silicone. Hermetically sealed units for double glazed panel. m2 m2 m2
M430
nr
M440
nr
M450
500 x 500 x 4 mm thick mirror with 4 nos. drilled holes, fixed with dome head mirror screws.
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M511
Homogeneous tiles; [300 x 300 x 7.6 mm thick]. Rate to include cement mortar screed. [25 mm thick] cement and sand pavings to floor. [25 mm] thick granolithic finish to floor. [10 mm] thick wash aggregates finish to floor. [500 mm x 500 mm] square carpet tiles with knot density of 30 knots per cm2 as per Specification clause (.). [4 mm] thick vinyl sheet floor covering. Rate to include approved adhesive bedding component. Floor hardener with iron aggregate or 100% ferrous metallic surface applied at the rate of 4.0 kg/m2, finished with a layer of acrylic based curing compound.
m2
m2 m2 m2 m2
M516
m2
M517
m2
Skirting to Floor Rate for skirting to floor shall be deemed to include fixing, supply of fixing component, drilling or cutting of associated work, preparing surfaces, forming joints, mitres, angles, fillets, built-up edges, laying to cambers or falls and cement mortar screed.
M520
Homogenous tiles skirting [100 mm high x 7.6 mm] thick; rounded top edge. Wall Finishes Rate for wall finishes to include fixing, supply of fixing components, drilling or cutting of associated work, preparing surfaces, forming joints, mitres, angles, fillets, and built-up edges.
M531
[200 mm x 250 mm] ceramic wall tiles. Rate to include cement mortar screed. [20 mm] thick cement and sand plastering to wall. [20 mm] thick granolithic finish to wall.
m2
M532 M533
m2 m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M543.1
m2
M543.2
m2
M543.3
m2
M543.4
m2
M544 M545
m nr
M600
FLOOR AND WALL SYSTEM Wall Partition Rate for wall partitions to include fixing, supply of fixing components, drilling or cutting of associated work, forming holes, cutting, and making good for services.
M611 M612
[100 mm] thick eco-solid wall system. [10 mm] thick full board
m2 m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M614 M620
nr m2
M700
M710
Cold water plumbing system as per Specification clause (.) and as shown schematically in Drawing No. (.). Rate to include all fittings, stop-cocks, and taps.
sum
Water Storage Tank M720 [3000 litres] HDPE water storage tank as per Specification clause (.). Rate to include supporting frame. Sanitary Plumbing System M730 Sanitary plumbing system as per Specification clause (.) and as shown schematically in Drawing No. (.). Rate to include all fittings. Sanitary Appliances and Fittings M740 Water closets; [Claytan 404 6-litre single flush side lever], bottom inlet overflow cistern with flapper valve internal fittings including medium duty plastic seat and cover. nr sum nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
M752
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
N112
N122
N162
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
N212
N222
Prepare and apply [one] coat of base primer and [two] coats of alkyd gloss paint to: N261 Pipework surfaces of members exceeding 300 mm girth. m2
N262
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
N331.2
m2
N331.3
m2
N331.5
m2
N331.6
m2
N341.3
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
N400
CEMENT PAINT Prepare and apply [one] coat of sealer and [two] coats of cement paint externally to: Rough Surfaces
N441
m2
N500
EPOXY OR POLYURETHANE PAINT Metal Surfaces Rate for painting of metal shall be deemed to include painting the surfaces of connecting plates, brackets, rivets, bolts, nuts, and similar projections. Prepare and apply [one] coat of base primer and two coats of epoxy paint externally to:
N511.1
Metal surfaces other than pipework; surfaces of members exceeding 300 mm girth. Metal surfaces other than pipework; surfaces of members not exceeding 300 mm girth. Prepare and apply [one] coat of base primer and two coats of polyurethane paint externally to:
m2
N512.1
N511.2
Metal surfaces other than pipework; surfaces of members exceeding 300 mm girth. Metal surfaces other than pipework; surfaces of members not exceeding 300 mm girth.
m2
N512.2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
N531.2
m2
N531.3
m2
N531.5
m2
N531.6
m2
N541.2
m2
Prepare and apply [one] coat of base primer and two coats of polyurethane paint externally to: N541.3 Rough rendered surfaces of [walls, columns, ...] exceeding 300 mm girth. Rough concrete surfaces of [walls, columns, .] formed using Class F1 formwork, exceeding 300 mm girth. m2
N541.4
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
N562.1
Pipework surfaces of members not exceeding 300 mm girth. Prepare and apply [one] coat of base primer and two coats of polyurethane paint externally to:
N561.2
m2
N562.2
N600
BITUMINOUS OR COAL TAR PAINT Prepare and apply [two] coats of bituminous or coal tar paint to: Metal Surfaces Rate for painting of metal shall be deemed to include painting the surfaces of connecting plates, brackets, rivets, bolts, nuts, and similar projections.
N611
Metal surfaces other than pipework; surfaces of members exceeding 300 mm girth. Metal surfaces other than pipework; surfaces of members not exceeding 300 mm girth. Smooth Surfaces
m2
N612
N631.1
Smooth plastered surfaces of [walls, columns, .] exceeding 300 mm girth. Smooth concrete surfaces of class F2 exceeding 300 mm girth. Smooth concrete surfaces of [walls, columns, .] formed using Class F2 formwork, exceeding 300 mm girth.
m2
N631.2
m2
N631.3
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
N641.2
m2
Pipework Rate for painting of pipeworks shall be deemed to include painting the surfaces of flanges, valves, other projecting fittings and hangers. N661 Pipework surfaces of members exceeding 300 mm girth. m2
N662
N700
CHLORINATED RUBBER PAINT Prepare and apply [one] coat of base primer and [two] coats of chlorinated rubber paint to: Metal Surface Rate for painting of metal shall be deemed to include painting the surfaces of connecting plates, brackets, rivets, bolts, nuts, and similar projections.
N711
Metal surfaces other than pipework; surfaces of members exceeding 300 mm girth. Metal surfaces other than pipework; surfaces of members not exceeding 300 mm girth. Smooth Surfaces
m2
N712
N731.1
Smooth plastered surfaces of [walls, columns, .] exceeding 300 mm girth. Smooth concrete surfaces of [walls, column, .] formed using Class F2 formwork exceeding 300 mm girth.
m2
N731.2
m2
N731.3
Smooth concrete surfaces of [walls, columns, .] formed using Class F3 formwork exceeding 300 mm girth.
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
N741.2
m2
Pipework Rate for painting of pipework shall be deemed to include painting the surfaces of flanges, valves, and other projecting fittings and hangers. N761 Pipework surfaces of members exceeding 300 mm girth. m2
N762
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O100 Description TRENCH EXCAVATION Trench excavation shall be deemed to include preparation of surfaces, excavation for bedding, multiple handling, disposal of surplus excavated material (including unsuitable material), upholding sides of excavation, allowance for working space, backfilling, removal of dead services, and reinstatement of original surface unless covered by separate items. Unit Qty. Rate Amount (RM)
100 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 100 mm DN pipe, depth not exceeding 1.5 m. In earth for 100 mm DN pipe, depth 1.5 2.0 m. In earth for 100 mm DN pipe, depth 2.0 2.5 m. In earth for 100 mm DN pipe, depth 2.5 3.0 m. 150 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 150 mm DN pipe, depth not exceeding 1.5 m. In earth for 150 mm DN pipe, depth 1.5 2 m. In earth for 150 mm DN pipe, depth 2.0 2.5 m. In earth for 150 mm DN pipe, depth 2.5 3.0 m. 200 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 200 mm DN pipe, depth not exceeding 1.5 m. In earth for 200 mm DN pipe, depth 1.5 2.0 m. In earth for 200 mm DN pipe, depth 2.0 2.5 m. In earth for 200 mm DN pipe, depth 2.5 3.0 m. m m m
m m m
m m m
m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description 300 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 300 mm DN pipe, depth not exceeding 1.5 m. In earth for 300 mm DN pipe, depth 1.5 2 m. In earth for 300 mm DN pipe, depth 2.0 2.5 m. In earth for 300 mm DN pipe, depth 2.5 3.0 m. 400 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 400 mm DN pipe, depth not exceeding 1.5 m. In earth for 400 mm DN pipe, depth 1.5 2 m. In earth for 400 mm DN pipe, depth 2.0 2.5 m. In earth for 400 mm DN pipe, depth 2.5 3.0 m. 500 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 500 mm DN pipe, depth not exceeding 1.5 m. In earth for 500 mm DN pipe, depth 1.5 2 m. In earth for 500 mm DN pipe, depth 2.0 2.5 m. In earth for 500 mm DN pipe, depth 2.5 3.0 m. In earth for 500 mm DN pipe, depth 3.0 4.0 m. 600 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 600 mm DN pipe, depth not exceeding 1.5 m. In earth for 600 mm DN pipe, depth 1.5 2.0 m. In earth for 600 mm DN pipe, depth 2.0 2.5 m. m m m m Unit Qty. Rate Amount (RM)
m m m
m m m
m m m m
O112 O113
m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O114 O115 Description In earth for 600 mm DN pipe, depth 2.5 3.0 m. In earth for 600 mm DN pipe, depth 3.0 4.0 m. 800 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 800 mm DN pipe, depth not exceeding 1.5 m. In earth for 800 mm DN pipe, depth 1.5 2.0 m. In earth for 800 mm DN pipe, depth 2.0 2.5 m. In earth for 800 mm DN pipe, depth 2.5 3.0 m. In earth for 800 mm DN pipe, depth 3.0 4.0 m. 1000 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1000 mm DN pipe, depth not exceeding 1.5 m. In earth for 1000 mm DN pipe, depth 1.5 2.0 m. In earth for 1000 mm DN pipe, depth 2.0 2.5 m. In earth for 1000 mm DN pipe, depth 2.5 3.0 m. In earth for 1000 mm DN pipe, depth 3.0 4.0 m. 1200 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1200 mm DN pipe, depth not exceeding 1.5 m In earth for 1200 mm DN pipe, depth 1.5 2 m In earth for 1200 mm DN pipe, depth 2.0 2.5 m In earth for 1200 mm DN pipe, depth 2.5 3.0 m In earth for 1200 mm DN pipe, depth 3.0 4.0 m m m m Unit m m Qty. Rate Amount (RM)
m m m m
m m m m
m m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description 1400 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1400 mm DN pipe, depth not exceeding 1.5 m. In earth for 1400 mm DN pipe, depth 1.5 2.0 m. In earth for 1400 mm DN pipe, depth 2.0. 2.5 m In earth for 1400 mm DN pipe, depth 2.5 3.0 m. In earth for 1400 mm DN pipe, depth 3.0 4.0 m. 1600 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1600 mm DN pipe, depth not exceeding 1.5 m. In earth for 1600 mm DN pipe, depth 1.5 2.0 m. In earth for 1600 mm DN pipe, depth 2.0 2.5 m. In earth for 1600 mm DN pipe, depth 2.5 3.0 m. In earth for 1600 mm DN pipe, depth 3.0 4.0 m. In earth for 1600 mm DN pipe, depth 4.0 5.0 m. 1800 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 1800 mm DN pipe, depth not exceeding 1.5 m. In earth for 1800 mm DN pipe, depth 1.5 2.0 m. In earth for 1800 mm DN pipe, depth 2.0 2.5 m. In earth for 1800 mm DN pipe, depth 2.5 3.0 m. In earth for 1800 mm DN pipe, depth 3.0 4.0 m. In earth for 1800 mm DN pipe, depth 4.0 5.0 m. m m m Unit Qty. Rate Amount (RM)
m m m m
m m m m m
m m m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description 2000 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O111 In earth for 2000 mm DN pipe, depth not exceeding 1.5 m. In earth for 2000 mm DN pipe, depth 1.5 2.0 m. In earth for 2000 mm DN pipe, depth 2.0 2.5 m. In earth for 2000 mm DN pipe, depth 2.5 3.0 m. In earth for 2000 mm DN pipe, depth 3.0 4.0 m. In earth for 2000 mm DN pipe, depth 4.0 5.0 m. 2200 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O112 O113 O114 O115 O116 In earth for 2200 mm DN pipe, depth 1.5 2.0 m. In earth for 2200 mm DN pipe, depth 2.0 2.5 m. In earth for 2200 mm DN pipe, depth 2.5 3.0 m. In earth for 2200 mm DN pipe, depth 3.0 4.0 m. In earth for 2200 mm DN pipe, depth 4.0 5.0 m. 2400 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O112 O113 O114 O115 O116 O117 In earth for 2400 mm DN pipe, depth 1.5 2.0 m. In earth for 2400 mm DN pipe, depth 2.0 2.5 m. In earth for 2400 mm DN pipe, depth 2.5 3.0 m. In earth for 2400 mm DN pipe, depth 3.0 4.0 m. In earth for 2400 mm DN pipe, depth 4.0 5.0 m. In earth for 2400 mm DN pipe, depth 5.0 6.0 m. 2600 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O112 In earth for 2600 mm DN pipe, depth 1.5 2.0 m. m m m m m m m m m m m m m Unit Qty. Rate Amount (RM)
m m m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O113 O114 O115 O116 O117 Description In earth for 2600 mm DN pipe, depth 2.0 2.5 m. In earth for 2600 mm DN pipe, depth 2.5 3.0 m. In earth for 2600 mm DN pipe, depth 3.0 4.0 m. In earth for 2600 mm DN pipe, depth 4.0 5.0 m. In earth for 2600 mm DN pipe, depth 5.0 6.0 m. 2800 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos. () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O112 O113 O114 O115 O116 O117 O118 In earth for 2800 mm DN pipe, depth 1.5 2.0 m. In earth for 2800 mm DN pipe, depth 2.0 2.5 m. In earth for 2800 mm DN pipe, depth 2.5 3.0 m. In earth for 2800 mm DN pipe, depth 3.0 4.0 m. In earth for 2800 mm DN pipe, depth 4.0 5.0 m. In earth for 2800 mm DN pipe, depth 5.0 6.0 m. In earth for 2800 mm DN pipe, depth exceeding 6.0 m. m m m m m m m Unit m m m m m Qty. Rate Amount (RM)
3000 mm DN pipe [Jalan Paip to Jalan Besi] as shown in Drawing Nos () to (). Width of trench shall be as shown in Drawing No. () and Specification clause (). O113 O114 O115 O116 O117 O118 In earth for 3000 mm DN pipe, depth 2.0 2.5 m. In earth for 3000 mm DN pipe, depth 2.5 3.0 m. In earth for 3000 mm DN pipe, depth 3.0 4.0 m. In earth for 3000 mm DN pipe, depth 4.0 5.0 m. In earth for 3000 mm DN pipe, depth 5.0 6.0 m. In earth for 3000 mm DN pipe, depth exceeding 6.0 m. m m m m m m
Extras to Trench Excavation O121 O122 O123 Rock. Natural hard material. Artificial hard material. m3 m3 m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O124 Description Roads and pavement, rate to include road cutting and reinstatement. Excavation for Manholes and Chambers O131.1 O131.2 O132.1 O132.2 In earth for [manholes]. In earth for [valve chambers]. Roads and pavement for [manholes]. Roads and pavement for [valve chambers], rate to include road cutting and reinstatement. Artificial hard material for [manholes]. Artificial hard material for [valve chambers]. Natural hard material for [manholes]. Natural hard material for [valve chambers]. In rock for [manholes]. In rock for [valve chambers]. m3 m3 m2 m2 Unit m2 Qty. Rate Amount (RM)
m3 m3 m3 m3 m3 m3
O200
O211
[150 mm thick] sand bedding as per Specification clause (..) and as shown in Drawing No. (.). [150 mm thick] granular material as bedding as per Specification clause (..) and as shown in Drawing No. (.). [150 mm thick] Grade C20 mass concrete bedding. Rate to include formwork. [150 mm thick] Grade C25 reinforced concrete bedding with one layer of high tensile steel fabric mesh A193 (A7), 3.02 kg/m2. Rate to include formwork.
O212
O213
O214
Surround O221 [250 mm] sand surround as per Specification clause (..) and as shown in Drawing No. (.). [200 mm] granular material surround as per Specification clause (..) and as shown in Drawing No. (.). m
O222
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O223 Description [150 mm] Crade C20 mass concrete surround. Rate to include formwork. [150 mm] Grade C25 reinforced concrete surround with one layer of high tensile steel fabric mesh A193 (A7), 3.02 kg/m2 all round. Rate to include formwork. Unit m Qty. Rate Amount (RM)
O224
O232
m3
O300
PIPES Supply, laying or install. Rate to include all pipe cutting, wrapping, lining and lagging as required.
Sewerage Pipework Vitrified clay pipes, spigot socket ended including supply and making joints complete as per Specification clause (.) for the following: O311.1 [100 mm DN] in standard length of 1.25 m. Rate to include all fittings and valves. [150 mm DN] in standard length of 1.50 m. [200 mm DN] in standard length of 1.50 m. [225 mm DN] in standard length of 2.0 m. [300 mm DN] in standard length of 2.50 m. [400 mm DN] in standard length of 2.50 m. [600 mm DN] in standard length of 2.50 m. [1400 mm DN] in standard length of 2.0 m. [Centrifugally spun] reinforced concrete pipes, spigot socket ended to [MS 881] lined internally with [12 mm thick high alumina cement mortar] as per Specification clause (.). Rate to include supply and making joint complete for the following: O312.1 O312.2 450 mm DN in standard length of 3.0 m. 600 mm DN in standard length of 3.0 m. m m m
m m m m m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O312.3 O312.4 O312.5 O312.6 O312.7 Description 750 mm DN in standard length of 3.0 m. 900 mm DN in standard length of 3.0 m. 1200 mm DN in standard length of 3.0 m. 1500 mm DN in standard length of 3.0 m. 1800 mm DN in standard length of 3.0 m. High density polyethylene corrugated wall pipes to [DIN 16961]. Rate to include supply and making joints complete. O313.1 100 mm DN in standard length of 6 m. Rate to include all fittings and valves. 150 mm DN in standard length of 6 m. 200 mm DN in standard length of 6 m. 300 mm DN in standard length of 6 m. 450 mm DN in standard length of 6 m. 600 mm DN in standard length of 6 m. [Spigot socket ended] ductile iron pipes to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause (). Rate to include supply and making joints complete for the following: m Unit m m m m m Qty. Rate Amount (RM)
m m m m m
O314.1
100 mm DN in standard length of 6 m. Rate to include all fittings and valves. 150 mm DN in standard length of 6 m. 200 mm DN in standard length of 6 m. 300 mm DN in standard length of 6 m. 400 mm DN in standard length of 6 m. 500 mm DN in standard length of 6 m. 600 mm DN in standard length of 6 m. 700 mm DN in standard length of 6 m.
m m m m m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description [Mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] as per Specification clause (.) for the following: Unit Qty. Rate Amount (RM)
O315.1
100 mm DN [spigot socket ended] in standard length of 6 m. Rate to include all fittings, valves, and joints.
O315.2
150 mm DN [spigot socket ended] in standard length of 6 m. 200 mm DN [spigot socket ended] in standard length of 6 m. 300 mm DN [spigot socket ended] in standard length of 6 m. 400 mm DN [spigot socket ended] in standard length of 6 m. 450 mm DN [spigot socket ended] in standard length of 6 m. 500 mm DN [spigot socket ended] in standard length of 10 m. 600 mm DN [spigot socket ended] in standard length of 10 m. 800 mm DN [spigot socket ended] in standard length of 10 m.
O315.3
O315.4
O315.5
O315.6
O315.7
O315.8
O315.9
O315.10 1000 mm DN [spigot socket ended] in standard length of 10 m. O315.11 2200 mm DN [spigot socket ended] in standard length of 10 m. O315.12 2300 mm DN [spigot socket ended] in standard length of 7.5 m. O315.13 2600 mm DN [spigot socket ended] in standard length of 7.5 m. O315.14 3000 mm DN [spigot socket ended] in standard length of 7.5 m. Spigot socket ended glass reinforced plastic pipes, as per Specification clause (). Rate to include supply and making joints complete for the following:
O316.1
[300 mm DN, PN 16] with stiffnes of [10 kN/m2] in standard length of [12 m].
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O316.2 Description [375 mm DN, PN 16] with stiffnes of [10 kN/m2] in standard length of [12 m]. [450 mm DN, PN 10] with stiffnes of [10 kN/m2] in standard length of [12 m]. [600 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [750 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [900 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [3000 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. High density polyethylene (HDPE) solid wall plain ended pipe to MS 1058 as per Specification clause (.) for the following: O317.1 [110 mm OD, PE 80, PN 16] in standard length of 12 m. m Unit m Qty. Rate Amount (RM)
O316.3
O316.4
O316.5
O316.6
O316.7
O317.2
[110 mm OD, PE 100, PN 20] in standard length of 12 m. [200 mm OD, PE 80, PN 16] in standard length of 12 m.
O317.3
O317.4
O317.5
[710 mm OD, PE 80, PN 12.5] in standard length of 12 m. Acrylonitrile butadiene styrene (ABS) pipe plain ended to MS 1419 as per Specification clause () for the following:
O318.1
[140 mm OD, PN6] in standard length of 5.8 m. Rate to include all fittings, valves, and joints. [225 mm OD, PN 10] in standard length of 5.8 m. [250 mm OD, PN 12] in standard length of 5.8 m. [355 mm OD, PN 15] in standard length of 5.8 m. [400 mm OD, PN 15] in standard length of 5.8 m. [450 mm OD, PN 15] in standard length of 5.8 m.
m m m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O318.7 O318.8 O318.9 Description [560 mm OD, PN 15] in standard length of 5.8 m. [630 mm OD, PN 15] in standard length of 5.8 m. [710 mm OD, PN 10] in standard length of 5.8 m. Water Supply Pipework [Mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] as per Specification clause (.) for the following: Unit m m m Qty. Rate Amount (RM)
O321.1
100 mm DN [spigot socket ended] in standard length of 6 m. Rate to include all fittings, valves, and joints.
O321.2
150 mm DN [spigot socket ended] in standard length of 6 m. 200 mm DN [spigot socket ended] in standard length of 6 m. 300 mm DN [spigot socket ended] in standard length of 6 m. 400 mm DN [spigot socket ended] in standard length of 6 m. 450 mm DN [spigot socket ended] in standard length of 6 m. 500 mm DN [spigot socket ended] in standard length of 10 m. 600 mm DN [spigot socket ended] in standard length of 10 m. 800 mm DN [spigot socket ended] in standard length of 10 m.
O321.3
O321.4
O321.5
O321.6
O321.7
O321.8
O321.9
O321.10 1000 mm DN [spigot socket ended] in standard length of 10 m. O321.11 2200 mm DN [spigot socket ended] in standard length of 10 m. O321.12 2300 mm DN [spigot socket ended] in standard length of 7.5 m. O321.13 2600 mm DN [spigot socket ended] in standard length of 7.5 m. O321.14 3000 mm DN [spigot socket ended] in standard length of 7.5 m.
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description [Spigot socket ended] ductile iron pipes to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause (). Rate to include supply and making joints complete for the following: Unit Qty. Rate Amount (RM)
O322.1
100 mm DN in standard length of 6 m. Rate to include all fittings and valves. 150 mm DN in standard length of 6 m. 200 mm DN in standard length of 6 m. 300 mm DN in standard length of 6 m. 400 mm DN in standard length of 6 m. 500 mm DN in standard length of 6 m. 600 mm DN in standard length of 6 m. 700 mm DN in standard length of 6 m. High density polyethylene (HDPE) solid wall plain ended pipe to MS 1058 as per Specification clause (.) for the following:
m m m m m m m
O323.1
O323.2
[110 mm OD, PE 100, PN 20] in standard length of 12 m. [200 mm OD, PE 80, PN 16] in standard length of 12 m.
O323.3
O323.4
O323.5
[710 mm OD, PE 80, PN 12.5] in standard length of 12 m. Unplasticised polyvinyl chloride (uPVC) pipes to MS 628, with bell mouth joints as per Specification clause (.). Rate to include supply and making joints complete for the following:
O324.1
[100 mm DN, PN 15] in standard length of 6 m. Rate to include fittings and valves. [155 mm DN, PN 15] in standard length of 6 m. [200 mm DN, PN 15] in standard length of 6 m. [250 mm DN, PN 15] in standard length of 6 m.
m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O324.5 Description [300 mm DN, PN 15] in standard length of 6 m. Spigot socket ended glass reinforced plastic pipes, as per Specification clause (). Rate to include supply and making joints complete for the following: Unit m Qty. Rate Amount (RM)
O325.1
[300 mm DN, PN 16] with stiffnes of [10 kN/m2] in standard length of [12 m]. [375 mm DN, PN 16] with stiffnes of [10 kN/m2] in standard length of [12 m]. [450 mm DN, PN 10] with stiffnes of [10 kN/m2] in standard length of [12 m]. [600 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [750 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [900 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [3000 mm DN, PN 6] with stiffnes of [5 kN/m2] in standard length of [12 m]. [300 mm DN] plain ended stainless steel pipes as per Specification clause (.). Acrylonitrile butadiene styrene (ABS) pipe plain ended to MS 1419 as per Specification clause () for the following:
O325.2
O325.3
O325.4
O325.5
O325.6
O325.7
O326
O327.1
[88.9 mm OD, PN6] in standard length of 5.8 m. Rate to include all fittings, valves, and joints. [225 mm OD, PN 10] in standard length of 5.8 m. [250 mm OD, PN 12] in standard length of 5.8 m. [355 mm OD, PN 15] in standard length of 5.8 m. [400 mm OD, PN 15] in standard length of 5.8 m. [450 mm OD, PN 15] in standard length of 5.8 m. [560 mm OD, PN 15] in standard length of 5.8 m. [630 mm OD, PN 15] in standard length of 5.8 m. [710 mm OD, PN 10] in standard length of 5.8 m.
m m m m m m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description Multilayer polyvinyl chloride(MPVC) pipes to JIS K6742 with bell moouth joints as per Specification clause (.). Rate to include supply and making joints complete for the following: O328.1 [100 mm DN, PN 15] in standard length of 6 m. Rate to include fittings and valves. [155 mm DN, PN 15] in standard length of 6 m. [200 mm DN, PN 15] in standard length of 6 m. [250 mm DN, PN 15] in standard length of 6 m. [300 mm DN, PN 15] in standard length of 6 m. Other Pipework [Spigot socket ended] ductile iron pipes to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause (). Rate to include supply and making joints complete for the following: m Unit Qty. Rate Amount (RM)
m m m m
O331.1
100 mm DN in standard length of 6 m. Rate to include all fittings and valves. 150 mm DN in standard length of 6 m. 200 mm DN in standard length of 6 m. 300 mm DN in standard length of 6 m. 400 mm DN in standard length of 6 m. 500 mm DN in standard length of 6 m. 600 mm DN in standard length of 6 m. 700 mm DN in standard length of 6 m. [Mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] as per Specification clause (.) for the following:
m m m m m m m
O332.1
100 mm DN [spigot socket ended] in standard length of 6 m. Rate to include all fittings, valves, and joints.
O332.2
150 mm DN [spigot socket ended] in standard length of 6 m. 200 mm DN [spigot socket ended] in standard length of 6 m.
O332.3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O332.4 Description 300 mm DN [spigot socket ended] in standard length of 6 m. 400 mm DN [spigot socket ended] in standard length of 6 m. 450 mm DN [spigot socket ended] in standard length of 6 m. 500 mm DN [spigot socket ended] in standard length of 10 m. 600 mm DN [spigot socket ended] in standard length of 10 m. Unplasticised polyvinyl chloride (uPVC) pipes to MS 628, with bell moouth joints as per Specification clause (.). Rate to include supply and making joints complete for the following: O333.1 [100 mm DN, PN 15] in standard length of 6 m. Rate to include fittings and valves. [155 mm DN, PN 15] in standard length of 6 m. [200 mm DN, PN 15] in standard length of 6 m. [250 mm DN, PN 15] in standard length of 6 m. [300 mm DN, PN 15] in standard length of 6 m. m Unit m Qty. Rate Amount (RM)
O332.5
O332.6
O332.7
O332.8
m m m m
High density polyethylene (HDPE) solid wall plain ended pipe to MS 1058 as per Specification clause (.) for the following: O334.1 [110 mm OD, PE 80, PN 16] in standard length of 12 m. m
O334.2
[110 mm OD, PE 100, PN 20] in standard length of 12 m. [200 mm OD, PE 80, PN 16] in standard length of 12 m.
O334.3
O334.4
O334.5
[710 mm OD, PE 80, PN 12.5] in standard length of 12 m. Vitrified clay pipes, spigot socket ended including supply and making joints complete as per Specification clause (.) for the following:
O335.1
[100 mm DN] in standard length of 1.25 m. Rate to include all fittings and valves.
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O335.2 O335.3 O335.4 O335.5 O335.6 O335.7 O335.8 Description [150 mm DN] in standard length of 1.50 m. [200 mm DN] in standard length of 1.50 m. [225 mm DN] in standard length of 2.0 m. [300 mm DN] in standard length of 2.50 m. [400 mm DN] in standard length of 2.50 m. [600 mm DN] in standard length of 2.50 m. [1400 mm DN] in standard length of 2.0 m. Reinforced concrete pipes to [MS 881] butt jointed with collars as per Specification clause (.). Rate to include supply and making joint complete for the following: O336.1 [450 mm DN, Class X] in standard length of 3.0 m. m Unit m m m m m m m Qty. Rate Amount (RM)
[600 mm DN, Class Y] in standard length of 3.0 m. [750 mm DN, Class Z] in standard length of 3.0 m. [900 mm DN, Class X] in standard length of 3.0 m. [1200 mm DN, Class Y] in standard length of 3.0 m.
m m m m
O336.6
O336.7
O337
[300 mm DN] plain ended stainless steel pipes as per Specification clause (.). Exposed Pipework
O341
[300 mm DN] plain ended mild steel pipes to BS 534, concrete lined internally and painted externally with primer and finishing coat as per Specification clause () for stream-overcrossing at Sg. () as shown in Drawing No. (). [300 mm DN] plain ended stainless steel pipes as per Specification clause () for elevated pipe as shown in Drawing No. (). [300 mm DN double flanged] ductile iron pipes to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause () for drain overcrossing as shown in Drawing No. (...).
O342
O343
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O400 Description FITTINGS, VALVES, AND JOINTS Straight Specials Item for straight specials shall be deemed to include cutting where applicable. [Mild] steel pipes and fittings, shall be to Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] as per Specification clause (.): Unit Qty. Rate Amount (RM)
Ductile iron pipes and fittings shall be to [BS EN 545, with metallic zinc and bitumen external coating and cement mortar lined internally] as per Specification clause (). O411 [300 mm DN] mild steel plain ended pipes, [2000 mm] long. [300 mm DN] plain and flanged ended mild steel pipes, [2000 mm] long. Flanges shall be [PN 16 to BS EN 1092-1]. [300 mm DN] flanged ended mild steel pipes, [2000 mm] long. Flanges shall be [PN 16 to BS EN 1092-1]. nr
O412
nr
O413.1
nr
O413.2
[300 mm DN] flanged ended ductile iron pipes, [2000 mm] long. Flanges shall be [PN 16 to BS EN 1092-1].
nr
O414
[300 mm DN] plain ended mild steel pipe, [2000 mm] long with puddle flange at [1000 mm] from one end. Details of puddle flange shall be as shown in Drawing No. (). [300 mm DN] plain and flanged ended mild steel pipe, [2000 mm] long with puddle flange at [1000 mm] from flange end. Flange shall be [PN 16 to BS EN 1092-1] and details of puddle flange shall be as shown in Drawing No. (). [300 mm DN] flanged ended mild steel pipe, [2000 mm] long with puddle flange at [1000 mm] from one end. Flanges shall be [PN 16 to BS EN 1092-1] and details of puddle flange shall be as shown in Drawing No. ().
nr
O415
nr
O416.1
nr
O416.2
[300 mm DN] flanged ended ductile iron pipe, [2000 mm] long with puddle flange at [1000 mm] from one end. Flanges shall be [PN 16 to BS EN 1092-1] and details of puddle flange shall be as shown in Drawing No. ().
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Fittings O421.1 [300 mm DN, 90-degree plain ended mild steel gusseted] horizontal bend. [300 mm DN, 45-degree plain ended mild steel gusseted] horizontal bend. [300 mm DN, 45-degree plain ended mild steel gusseted] vertical bend. [300 mm DN, 45-degree plain ended mild steel gusseted] vertical bend painted externally with primer and finishing coat as per Specification clause (). nr Description Unit Qty. Rate Amount (RM)
O421.2
nr
O421.3
nr
O421.4
nr
O421.5
[300 mm DN, 90-degree double socket ended ductile iron] horizontal bend. [300 mm DN, 90-degree double flanged ductile iron short radius] horizontal bend. [300 mm DN, 45-degree double flanged ductile iron short radius] vertical bend. [300 mm DN, 90-degree double flanged ductile iron long radius] horizontal bend. [300 mm DN, 90-degree plain ended HDPE gusseted] horizontal bend. [300 mm DN] vitrified clay bellmouth Y-junction [300 mm DN] vitrified clay bellmouth tee. [300 mm DN] plain ended barrel with [100 mm DN] flanged branch concentric mild steel tee for air-valve as shown in Drawing No. (). [300 mm DN] plain ended barrel with [100 mm DN] flanged branch level invert mild steel tee for washout as shown in Drawing No. (). [600 mm DN] plain ended barrel with [400 mm DN] flanged branch concentric mild steel wye as shown in Drawing No. (). [600 mm DN] to [400 mm DN] plain ended mild steel concentric taper as shown in Drawing No. ().
nr
O421.6
nr
O421.7
nr
O421.8
nr
O421.9
nr
nr nr nr
O423.2
nr
O424
nr
O425.1
nr
O425.2
[600 mm DN] to [400 mm DN] plain ended mild steel level invert taper as shown in Drawing No. ().
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O426 Description [600 mm DN] ductile iron flanged bell mouth. Flanges shall be [PN 6 to BS EN 1092-1]. [600 mm DN] ductile iron blank flanges. Flanges shall be [PN 10 to BS EN 1092-1]. [600 mm DN] mild steel blank flanges. Flanges shall be [PN 10 to BS EN 1092-1]. [300 mm DN] double flanged ductile iron duckfoot bend. Valves O431.1 [100 mm DN] single orifice air valves. Rate to include isolating butterfly valve. [150 mm DN] double orifice air valves. Rate to include isolating butterfly valve. [600 mm DN] double flanged butterfly valves, PN 10 manually operated as per Specification clause (). Rate to include reduction gears. [600 mm DN] double flanged butterfly valves, PN 16 complete with electric actuators as per Specification clause (). Rate to include reduction gears. nr Unit nr Qty. Rate Amount (RM)
O427.1
nr
O427.2
nr
O428
nr
O431.2
nr
O432.1
nr
O432.2
nr
O433
[300 mm DN] double flanged gate valves, PN 10 manually operated as per Specification clause (). Rate to include reduction gears. [600 mm DN] full bore altitude valves as per Specification clause (). [600 mm DN] pressure reducing valves as per Specification clause (). [600 mm DN] pressure sustaining valves as per Specification clause (). [300 mm DN] double flanged non return valves, nonslam type, PN 16 as per Specification clause ().
nr
O434
nr
O435
nr
O436
nr
O437
nr
O438
[300 mm DN] double flanged plug, PN 16 as per Specification clause (). Valves
nr
O441
[600 mm square] stainless steel penstocks as per Specification clause (). [300 mm DN] cast iron flap gates as per Specification clause (.).
nr
O442
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O443 O444 Description [200 mm DN] flat seat valves. Pillar hydrants with double outlets as per Specification clause (.). [150 mm DN] stainless steel strainer. Joints Items for joints shall include supply of all jointing materials, bolts, nuts, washers, gaskets, making good of joints both internally and externally. O451.1 O451.2 [600 mm DN] mild steel welded collar joints. [800 mm DN] mild steel welded collar joints. Rate to include welding to internal of pipe and air testing of joints. HDPE welded collar by electrofusion for [180 mm OD, PE 80, PN 16] pipe. [600 mm DN] mild steel welded slip joints. [800 mm DN] mild steel welded slip joints. Rate to include welding to internal of pipe and air testing of joints. Butt fusion welded joints for [180 mm OD, PE 80, PN 16] pipe. [300 mm DN] mechanical coupling joints. [300 mm DN] mechanical stepped coupling joints. nr nr Unit nr nr Qty. Rate Amount (RM)
O445
nr
O451.3
nr
O452.1 O452.2
nr nr
O453
nr
O454.1 O454.2
nr nr
O455
[300 mm DN] flange adaptor joints as shown in Drawing No. (.). [600 mm DN] expansion joints as shown in Drawing No. (.). Push-on collar joints for 300 mm DN HDPE profiled wall pipes. Push-on slip joints for [900 mm DN] centrifugally spun reinforced concrete pipes. [200 mm DN] flow meter/bulk meter of the "Kent Helix" type. [200 mm DN] electromagnetic flow meter. [200 mm DN] ultrasonic flow meter.
nr
O456
nr
O457
nr
O458
nr
O460.1
nr
O460.2 O460.3
nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O500 Description BELOW GROUND CROSSINGS Rate for below ground crossings shall include reinstatement work. River, Stream, Culvert, or Canal O511 River, stream, culvert, or canal width, 1 3 m for [300 mm DN] pipe. River, stream, culvert, or canal width, 3 10 m for [300 mm DN] pipe. River, stream, culvert, or canal width exceeding 10 m for [300 mm DN] pipe. Fence O541 Crosssing under fence for [300 mm DN] pipe. Sewer or Drain O551.1 Crosssing over existing [400 mm DN] sewer pipe for [300 mm DN] pipe. Rate to include concrete surround to existing existing sewer pipe. Crosssing under 600 mm block drain for [300 mm DN] pipe. Rate to include concrete surround to pipe. nr nr nr Unit Qty. Rate Amount (RM)
O521
nr
O531
nr
O551.2
nr
Wall O561 Crossing under brickwall fence for [300 mm DN] pipe. Rate to include concrete surround to pipe. Other Stated Underground Services O571 Crossing under existing 600 mm DN water mains for [300 mm DN] pipe. [Rate to include sand surround to both existing and new pipe]. nr nr
O600
SPECIAL PIPE LAYING METHODS Item for special pipe laying methods is deemed to include mobilisation and demobilisation. Pipe Jacking Road crossing for [600 mm DN] water pipe at Jalan [Besi} by pipe jacking as shown in Drawing No. (.).
O611
Design, excavate, construct, and maintain jacking pits including sheet piling, bracing, waling, concrete thrust wall, anchor foundation, guide rails, and backfilling, etc.
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O612 Description Design, excavate, construct, and maintain receiving pits including sheet piling, bracing, waling, concrete thrust wall, anchor foundation, guide rails, and backfilling, etc. Unit nr Qty. Rate Amount (RM)
O613
Supply, haul, handle, jack in, and install of 1200 mm DN Reinforced Concrete jacking pipe class 'Z'. Rate to include mild steel joint and excavation within pipe sleeve and other materials for complete installation.
O615
Install [600 mm DN mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] within pipe sleeve. Pressure grouting for annulus space in between [600 mm DN steel pipe] and pipe sleeve as per Specification clause (.). Microtunneling Road crossing for [600 mm DN] water pipe at Jalan [Besi} by microtunneling as shown in Drawing No. (.).
O616
m3
O621
Design, excavate, construct, and maintain jacking pits including sheet piling, bracing, waling, concrete thrust wall, anchor foundation, guide rails, and backfilling, etc. Design, excavate, construct, and maintain receiving pits including sheet piling, bracing, waling, concrete thrust wall, anchor foundation, guide rails, and backfilling, etc.
nr
O622
nr
O624
Supply, haul, handle, jack in, and install of 1200 mm DN concrete cladded steel composite pipe. Rate to include mild steel joint and excavation within pipe sleeve and other materials for complete installation.
O625
Install [600 mm DN mild] steel pipes, Grade 43A to [BS 534, with bitumen wrap externally and concrete lining internally] within pipe sleeve. [450 mm OD, PE 80, PN 16] butt fusion welded HDPE pipe using the horizontal directional drilling method.
O630
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description Submarine Pipelaying O641 Bathymetric survey as per Specification clause (.) of approximately [25 km] by [500 m] at 25 meters line interval with cross ties at [250 m]. Sub-sea geophysical survey as per Specification clause (.) of approximately [25 km] by [500 m] at 50 meters line interval with cross ties at [500 m]. Rate to include report by a geophysicist. Mobilisation of all necessary plant and equipment, marine vessels, [winches], [lar-barge], etc to suit the method statement adopted for laying the sub-sea pipelines. Rate to include demobilisation upon completion of work. Provision of winch equipment to suit method statement adopted for laying the sub-sea pipelines. m Unit Qty. Rate Amount (RM)
O642
O643
sum
O644
sum
O645
Trenching across Sg. (.) for [300 mm DN] pipe as shown in Drawing No. (.) with cover of at least 1.5 m cover at the banks and 0.3 m at the deepest section of the river. [60 mm thick] concrete cladding to [300 mm DN] steel pipe. Lay [300 mm DN] API grade steel pipes by float and sink method. Lay [300 mm DN] API grade steel pipes by bottom pull method. Lay [500 mm DN] mild steel pipes by lay barge method.
O646
O651
O652
O653
O654
Carry out tie-in of riser pipe to land pipe as detailed in approved methd statement. Swabbing and gauging of completed pipeline until pipeline is clean and confirm integrity of pipeline to Specification clause (.). Inspection of sub-sea pipeline by divers. Pipe Bursting
sum
O655
O656
sum
O661
[450 mm OD, PE 80, PN 16] butt fusion welded HDPE pipe using the pipe bursting method.
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Slip Lining O671 Slip lining to existing 450 mm DN asbestos cement pipe using [450 mm OD, PE 80, PN 16] butt fusion welded HDPE pipe m Description Unit Qty. Rate Amount (RM)
O700
O711
Cleaning, jetting, and removal of carbonaceous formation intrusions. Rate to include making good existing sewer pipe. Local internal repairs. Pipe joint sealing, with cement mortar. Pipe joint sealing, with epoxy mortar under pressure.
m2 m m
O714 O715
External grouting using 4 nos. of holes. External grouting by injection of cement grout as per Specification clause (..). Rehabilitation of Existing Pipework
nr m3
O721
Cured in place lining with resin impregnated felt tube to finished internal daimeter of [600 mm]. In situ jointed pipe lining using glass reinforced plastic as per Specification clause (.) to finished internal diameter of 900 mm. Circular segmental lining using glass reinforced plastic as per Specification clause (.), with miniumum finished internal diameter of 900 mm. Circular segmental lining using 15 mm thick glass reinforced concrete as per Specification clause (.), with miniumum finished internal diameter of 900 mm.
O722
O723.1
O723.2
O724 O725
Stated proprietory lining, diameter stated. [50 mm thick] gunite coating to [900 mm DN] sewer pipe. Cement grout as per Specification clause (..) as annulus grouting to [900 mm DN} pipe.
m m2
O726
m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description Rehabilitation of Existing Manholes O731 Abandonment of existing manholes as per Drawing No. (.) for depth of [2.5 m] including removing cover slab, breaking back shaft sealing off the ends of existing pipework and backfilling with sand. nr Unit Qty. Rate Amount (RM)
O732
Modification of existing manholes for manhole as shown in Drawing No. (..) including work to benching and inverts, breaking out, re-haunching, and dealing with flows.
nr
O800
O811
Brick manholes Type [A] with heavy duty cover and frame for [2.5 m depth] as shown in Drawing No. (.). Rate to include blinding, reinforced concrete base and top slabs. Reinforced concrete manholes with heavy duty cover and frame Type [1] as shown in Drawing No. (..).
nr
O812
nr
O813
Reinforced concrete manholes with backdrops, heavy duty cover, and frame Type [1] as shown in Drawing No. (..). Rate to include the pipework and associated fittings comprising the backdrops.
nr
O814
Precast concrete manholes Type [2] with heavy duty cover and frame as shown in Drawing No. (..).
nr
O815
Precast concrete manholes with backdrops Type [3] with heavy duty cover and frame as shown in Drawing No. (.). Rate to include the pipework and associated fittings comprising the backdrops.
nr
Testing and Inspection Rate for testing and inspection shall be deemed to include provision, and removal of all equipment, and ancillaries required for testing. O821 Testing of [300 mm DN vitrified clay pipe] gravity sewer. Rate to include testing by infiltration and provision of all water required for testing. m
O822
Testing of [300 mm DN vitrified clay pipe] vacuum sewer. Rate to include all equipment required.
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O823 Description Pressure and leakage testing for [600 mm DN mild steel pipe] from Jalan [Pipe] to Jalan [Besi]. Rate to include provision of all water required for testing. Flushing and sterilisingf or [600 mm DN mild steel pipe] from Jalan [Pipe] to Jalan [Besi]. Rate to include chemicals and provision of water. Close circuit television inspection survey for [300 mm DN] sewer pipe from Manhole [A] to Manhole [B] as shown in Drawing No. (..). Radiographic test for 3% of all welds for mild steel pipeline. Holiday detector test, rate to include provision of equipment, testing, and maintenance. Ultrasonic test, rate to include provision of equipment, testing, and maintenance. Temporary Diversion O831 Temporary diversion of existing utilities. Rate to include coordination with relevant authorities and provision of and removal of all equipment and ancillaries required, including pumping over. Temporary diversion of sewage flows for [300 mm DN] pipe from Manhole [A] to Manhole [B} as shown in Drawing No. (.......). Rate to include coordination with relevant authorities and provision of and removal of all equipment and ancillaries required including pumping over. Connections to Existing Sewer System Item for connections to existing sewer system shall be deemed to include coordination with authorities, payment of fees, isolations for shutdown of flows, and dewatering. O841 At existing [brick] manhole, size [1.5 m x 1.5 m x 2.0 m deep of [600 mm DN] vitrified clay sewer pipe. nr sum Unit m Qty. Rate Amount (RM)
O824
O825
O826
nr
O827
sum
O828
sum
O832
sum
O842
At Y-junction of existing [600 mm DN] vitrified clay sewer pipe. With saddle connection to existing [600 mm DN] vitrified clay sewer pipe.
nr
O843
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. O844 Description New manhole at existing [600 mm DN] vitrified clay sewer pipe. Rate to include breaking away of existing sewer pipe as required and all pipework and metalwork within the manhole. Connection to Existing Water Mains O851 Hot tapping connection work to existing [900 mm DN steel pipeline] as shown in Drawing No. (..). Rate to injclude tapping tees, isolating valve, and testing. nr Unit nr Qty. Rate Amount (RM)
O852
Shut down connection work to existing [900 mm DN steel pipeline] as shown in Drawing No. (..). Rate to include coordination with authorities, payment of fees, isolations for shutdown of flows, and dewatering.
nr
Pipework Ancillaries O861 Marker posts for air valve, washout, and isolating valves as shown in Drawing No. (.). Rate to include supply, installation, and painting. Ring girder for [1000 mm DN] mild steel pipe stream crossing at Sg. () as shown in Drawing No. (.). Rate to include supply, installation, and painting. nr
O862
nr
O863
Pipe straps for [600 mm DN] exposed pipelines. Rate to include supply, installation, and painting. Spike guard for [600 mm DN] mild steel pipe stream crossing at Sg. () as shown in Drawing No. (.). Rate to include supply, installation, and painting.
nr
O864
nr
O870
Reinstatement of landscaping from Ch (.) to Ch (.) for [600 mm DN] pipelaying work along Jalan [Besi].
sum
O880
Water sampling station as per Specification clause (). Rate to include connections to mains.
nr
Page Total carried to Summary of Class O Class O: Pipework Page BQO138 of BQO173
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
CLASS O Pipework
Item No. Code No. Description Summary of Class O: Pipework Page BQO1 Page BQO2 Page BQO3 Page BQO4 Page BQO5 Page BQO6 Page BQO7 Page BQO8 Page BQO9 Page BQO10 Page BQO11 Page BQO12 Page BQO13 Page BQO14 Page BQO15 Page BQO16 Page BQO17 Page BQO18 Page BQO19 Page BQO20 Page BQO21 Page BQO22 Page BQO23 Page BQO24 Page BQO25 Page BQO26 Page BQO27 Page BQO28 Total of Class O carried to Grand Summary Unit Qty. Rate Amount (RM)
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
[600 mm] precast concrete block drain for Road [A] as shown in Drawing No. (.). P111.1 In earth for [600 mm precast concrete block drain], depth not exceeding 1.5 m. In earth for [600 mm precast pipe culvert], depth not exceeding 1.5 m. In earth for [600 mm precast concrete block drain], depth 1.5 2.0 m. In earth for [900 mm precast pipe culvert], depth 1.5 2.0 m. In earth for [600 mm precast concrete block drain], depth 2.0 2.5 m. In earth for [1200 mm precast pipe culvert], depth 2.0 2.5 m. In earth for [600 mm precast concrete block drain], depth 2.5 3.0 m. In earth for [1200 mm precast pipe culvert], depth 2.5 3.0 m. In earth for [600 mm precast concrete block drain], depth exceeding 3.0 m. In earth for [1800 mm precast pipe culvert], depth exceeding 3.0 m. Extras to Drain Excavation P121 Roads and pavement, rate to include road cutting and reinstatement. Artificial hard material. Natural hard material. Rock. m2 m
P111.2
P112.1
P112.2
P113.1
P113.2
P114.1
P114.2
P115.1
P115.2
m3 m3 m3
Page Total carried to S ummary of Class P Class P: Drainage Work Page BQP140 of BQP173
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
P131.2 P132
m3 m2
m3 m3 m3
P200
SURFACE DRAINS Item for surface drains shall be deemed to include cement jointing, sand and concrete beddings, shuttering, struts, and weepholes.
P210
Interceptor drains; reinforced concrete grade 20; 1200 mm wide (average) x 600 mm deep x 75 mm thick trapezoidal shape. Bench and berm drains; reinforced concrete grade 20; 900 mm wide x 500 mm deep x 75 mm thick V-shape.
P220
P230
Roadside drain; 600 mm wide block drain with average 900 mm high brick wall and plastering including 600 mm x 100 mm x 100 mm precast concrete struts at 6 m c/c. Median drain; precast concrete U-shaped drain with dry weather flow; 600 mm wide x 1200 mm deep including precast concrete struts at 6 m c/c. Toe drain; precast concrete U-shaped drain with dry weather flow; 1200 mm wide x 1200 mm deep including precast concrete struts at 6 m c/c. Cascade drains; precast concrete block drain; 600 mm wide x 400 mm deep at berms. Monsoon drain; precast concrete U-shaped drain with dry weather flow; 2400 mm wide x 2400 mm deep including precast concrete struts at 6 m c/c. Grass swale; with shape as shown in Drawing No. (..).
P240
P250
P260
P270
P280
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
P320
Outlet drains; 100 mm diameter UPVC pipe including fittings. Rate to include bends, filter fabric and concrete surround. 300 mm thick sand as drainage blanket as per Specification clause (.). [150 mm] diameter scupper drains.
P330
m2
P340
P400
Rate for downpipes to include fixing and supply of fixing components. P410 P420 [150 diameter uPVC] rain water down pipes. [150 diameter uPVC] elbow for rain water down pipes. m nr
P500
DRAIN COVERS Item for drain covers shall be deemed to include lifting hook/hole and all associated fittings.
P510
Precast concrete; 600 mm wide x 75 mm thick for [100 kN load] median drain. Galvanised mild steel grating cover for [100 kN load], 600 mm wide as shown in Drawing No. (.) for road side drain. Fibre reinforced plastic for [100 kN load] as per Specification clause (.); 225 mm wide for roadside drain.
P520
P530
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Item for culverts shall be deemed to include all joints, water stop, concrete base, and concrete surround unless otherwise stated. P611 [1200 mm] diameter single precast concrete pipe culvert, Class [X] in standard length of 1 m. [1200 mm] diameter twin precast concrete pipe culvert, Class [X] in standard length of 1 m. [1200 mm] diameter triple precast concrete pipe culvert, Class [X] in standard length of 1 m. Precast Box Culvert P621.1 [1200 mm x 1200 mm] single precast box culvert in standard length of 1 m. [1200 mm x 1200 mm] single precast box culvert with dry weather flow in standard length of 1 m. [1200 mm x 1200 mm] twin precast box culvert in standard length of 1 m. [1200 mm x 1200 mm] twin precast box culvert with dry weather flow in standard length of 1 m. [1200 mm x 1200 mm] triple precast box culvert in standard length of 1 m. [1200 mm x 1200 mm] triple precast box culvert with dry weather flow in standard length of 1 m. Corrugated Metal Pipe P631 [1200 mm] diameter single corrugated metal pipe culvert in standard length of [] m. [1200 mm] diameter twin corrugated metal pipe culvert in standard length of [] m. [1200 mm] diameter triple corrugated metal pipe culvert in standard length of [] m. m m m
P612
P613
P621.2
P622.1
P622.2
P623.1
P623.2
P632
P633
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Item for sumps shall be deemed to include sand and concrete bedding, cement plastering, and metalwork.
P710
Bricks sumps; 900 mm x 900 mm x 1.20 m deep including mild steel grating cover for [100 kN load].
nr
P720
In situ concrete; 900 mm x 900 mm x 1.20 m deep including mild steel grating cover for [100 kN load].
nr
P730
Precast concrete; 900 mm x 900 mm x 1.20 m deep including mild steel grating cover for [100 kN load].
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Q120
m2
Q130
m2
Q141
Stabilise subgrade for [300 mm] top layer of subgrade using [100 kg] of lime per cubic metre of soil
m2
Q142
Stabilise subgrade for [300 mm] top layer of subgrade using [800 kg] of cement per cubic metre of soil
m2
Q200
Q210
Geotextile of the [non woven] type as per Specification clause (.). Granular material with a [CBR value of more than 30, complying with Type C] of Specification clause (..) in [100 mm] thick. Granular material with a [CBR value of more than 30, complying with Type C] of Specification clause (..) in [100 mm] thick to road shoulders. Laterite as per Specification clause (..) in [100 mm] thick. [Grade C15] lean concrete in 150 mm thick. Stabilised sub-base in proportion of [one part] lime to [four parts] approved earth as per Specification clause (..) in [100 mm] thick. Soil cement in proportion of [one part] cement to [four parts] approved earth as per Specification clause (.) in [100 mm] thick.
m2
Q220.1
m2
Q220.2
m2
Q230
m2
Q240 Q251
m2 m2
Q252
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Q320
m2
Q330.1
m2
Q330.2
m2
Q341
m2
Q342
m2
Q343
m2
Q352
m2
Q353
m2
Q400
Q410
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Q500 Q510.1
SURFACING Removal of flexible surface. Rate to include scarifying the existing exposed surface. Removal of flexible surfaces. Rate to include milling of existing roadbase before receiving the new roadbase material. [Bituminuous single layer] surface dressing, [20 mm thick using 10 mm chippings]. [Bituminuous double layer] surface dressing, [30 mm thick using 14 mm chippings]. Tack coat to be applied at a rate of [0.5 litre per square metre] as per Specificatio clause (.). Prime coat to be applied at a rate of [0.35 litres per square metre] as per Specificatio clause (.). [12 mm] nominal thickness polymer modified asphalt in [2] layers as per Specification clause (.). m2
Q510.2
m2
Q520.1
m2
Q520.2
m2
Q530
m2
Q540
m2
Q550
m2
Asphaltic Concrete Q561 Binder course, [60 mm] thick as per Specification clause (.). Wearing course [40 mm] thick as per Specification clause (.). Dense Bituminuous Macadam Q571 Binder course, [60 mm] thick as per Specification clause (.). Wearing course [40 mm] thick as per Specification clause (.). Regulating bituminous macadam levelling course BML 10 to the required formation level. m2 m2
Q562
m2
Q572
m2
Q580
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Q612
m2
Q613
m2
Q621.2
Q622.1
Q622.2
Q622.3
Q623.1
m2
Q623.2
m2
Q623.3
m2
Q624 Q630
Fabric of other stated material. Carriageway slab in [Grade C30, 200 mm] thick. Rate to include steel formwork. Concrete slab to apron [Grade C30, 150 mm] thick. Rate to include steel formwork. Joints in Concrete Pavement Joints in concrete pavements shall be deemed to include base preparation, joints, and cutting.
m2 m2
Q640
m2
Longitudinal joints, [200 mm] deep. Expansion joints, [200 mm] deep. Construction joints, [200 mm] deep.
m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Q657
Q662
m2
Q663
m2
Q700
KERBS, CHANNEL, AND EDGINGS Rate for kerbs, channels, and edgings shall be deemed to include beds, backings, reinforcement, joints, and cutting.
Q710.1
Precast concrete kerbs, Type I as shown in Drawing No. (.). Precast concrete kerbs, Type II as shown in Drawing No. (.). Precast concrete kerbs, Type III as shown in Drawing No. (.). Precast concrete kerbs, Type IV as shown in Drawing No. (.). In situ concrete kerbs, Type II as shown in Drawing No. (.). Concrete edgings of [150 mm x 100 mm high]. Concrete channels, Type A as shown in Drawing No. (.).
Q710.2
Q710.3
Q710.4
Q720
Q730 Q740
m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Q811.1
nr
Q811.2
Non-illuminated retro-reflective mounted on [aluminium] sheeting for [BERI LALUAN SIGN, RP.13]. Non-illuminated retro-reflective mounted on [aluminium] sheeting for [ROUNDABOUT AHEAD SIGN, WD.31]. Non-illuminated retro-reflective in [aluminium] sheeting for [SIDE ROAD, WD.27b to be mounted on gantry].
nr
Q811.3
nr
Q811.4
nr
Q812
Illuminated in [plastic] sheeting for [SIDE ROAD, WD.27b to be mounted on gantry]. Electronic sign of [2.5 m] x [1.5 m] as per Specification clause (). Pavement Markings Pavement markings shall generally be hot-applied superimposed reflectorised thermoplastic and in accordance with JKR Arahan Teknik (Jalan) 2D/85.
nr
Q813
m2
Q821.1
nr
Q821.2
nr
Q821.3
nr
[150 mm] wide continuous line [centre line] [150 mm] wide continuous line [edge line] [100 mm] wide intermittent [centre] line with [1000 mm] line and [1700 mm] gap
m m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Q823.3
m2 m2 m2
Q832 Q833
nr nr
Q841.2
Q842
Q843.1
Q843.2
[Single mounted corrugated steel beam] guardrail [with post at 3.8 m spacing inclusive of delineators]. Rate to include bolts, nuts, posts, and other ancillary work.
Q843.3
[Double mounted corrugated steel beam] guardrail [with post at 1.95 m spacing inclusive of delineators]. Rate to include bolts, nuts, posts, and other ancillary work.
Q843.4
[Double mounted corrugated steel beam] guardrail [with post at 3.8 m spacing inclusive of delineators]. Rate to include bolts, nuts, posts, and other ancillary work.
Page Total carried to Summary of Class Q Class Q: Roads and Pavings Page BQQ152 of BQQ173
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Q845
Kilometre post, [Type A]. Kilometre post, [Type B]. Hectometre marker in [3 mm] thick [galvanised steel plate] at 100-metre intervals. Anti-glare screen of [1.5 m height using corrugated sections]. [Polycarbonate] noise barrier [of 1.5 m height] as per Specification clause (.). Rate to include supply, fabrication, installation, bolts, nuts, posts, and other ancillary work and maintenance. Right of way (ROW) marker as shown in Drawing No. (.). [Carbon steel overhead] gantry of [ 20 m wide and 6 m high].
nr nr nr
Q855
Q856
Q857
nr
Q860
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
R122
sum
R123 R124
Lighting system as per Specification clause (). Compressed air system as per Specification clause ().
sum sum
R125
Telecommunication system as per Specification clause (). Dewatering system as per Specification clause ().
sum
R126
sum
R129
sum
Tunnel Portal R130 Tunnel portal as per Specification clause () and as shown in Drawing No. (). Rate to include steel ribs, shotcrete, sandbags, and all other necessary material and work including its subsequent removal. sum
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
R211.2
m3
R212
m3
R221.1
m3
R221.2
m3
R222
m3
R231
m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
R300
[100 mm] thick plain shotcrete to [smooth finish]. [50 mm] thick plain shotcrete to [rough finish]. [150 mm] thick [mesh] reinforced shotcrete to [smooth finish]. [100 mm] thick [steel fibre] reinforced shotcrete, [30 kg/m3] to [fair finish].
m2 m2 m2
R312.2
m2
Page Total carried to Summary of Class R Class R: Tunnel Work Page BQR157 of BQR173
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
R334
m2
Formwork Rate for formwork shall be deemed to include travel steel form for all inclination, alignment, and end form to construction joints. R340 Smooth finish to [tunnel] lining. Water Proofing R351.1 [230 mm] wide rubber waterstop. Rate to include cutting and jointing of waterstops and provision of special fittings at angles and junctions. [250 mm] wide PVC waterstop. Rate to include cutting and jointing of waterstops and provision of special fittings at angles and junctions. [1 mm] thick [HDPE] membrane. [2 mm] thick [PVC] membrane. [Water proofing paint] as per Specification clause (). m m2
R351.2
m2 m2 m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
R411
[5 m] internal diameter x [200 mm] thick segmental ring as shown in Drawing No.(). [200 mm] thick invert segment as shown in Drawing No.(). [Steel Lining, Cast Iron Lining and Ductile Iron Lining] Rate for [steel, cast iron and ductile iron] lining shall be deemed to include cutting and jointing, internal and external corrosion protection, stiffeners, fish tails, and purpose-made holes for annulus grouting.
R412
R420
[50 mm thick, grade 50B] steel lining of [3.5 m] internal diameter as per Specification clause (). [40 mm thick, grade 600/3] cast iron lining of [4 m] internal diameter as per Specification clause ().
R430
R440
[30 mm thick, grade 500/7] ductile iron lining of [5 m] internal diameter as per Specification clause ().
Annulus Grouting R450 Annulus grouting with [cement grout of w/c ratio 0.45:1] under [2] bars pressure. Water Proofing R460 [1 mm] thick [HDPE] membrane. m2 m3
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
R510.1 R510.2
Steel rib [H100 x 100 x 8 mm thick, 17.2 kg/m]. Steel rib [H125 x 125 x 9 mm thick, 23.8 kg/m].
t t
R522 R523
Steel plate [5 mm] thick. Mesh fabric [A142 (A6), 2.22 kg/m2]. Rate to include lapping and mesh pin. Bolting Rate for bolting shall be deemed to include all accessories and ancillary work as shown in the drawings. Exposed elements shall be protected against corrosion.
t m2
[T20 mm dia.] rock dowel of [1.5 m] long. [T25 mm dia.] rock dowel of [2 m] long. [T25 mm dia.] rock bolt of [2 m] long. [T25 mm dia.] rock bolt of [3 m] long. Pull out test for [T25 mm dia. rock bolt x 3 m long] with test load of [200 kN]. Shotcrete
nr nr nr nr nr
R541
[50 mm] thick plain shotcrete as per Specification clause () to [rough finish]. [150 mm] thick [steel fibre reinforced shotcrete (30 kg/m3)] as per Specification clause () to [rough finish]. Fibre Mortar
m2
R542
m2
R550
[25 mm] thick fibre mortar as per Specification clause () and as shown in the drawings.
m2
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
R562
nr
R600 R611 R612 R613 R614 R615 R621 R622 R623 R624 R631
BACKFILL Backfill invert with concrete [grade C20]. Backfill invert with plain shotcrete. Backfill invert with mortar [1:3]. Backfill invert with [cement grout 0.45:1]. Backfill invert with tunnel muck. Backfill behind lagging with concrete [grade C20]. Backfill behind lagging with plain shotcrete. Backfill behind lagging with mortar [1:3]. Backfill behind lagging with [cement grout 0.45:1]. Backfill [adit entrance] with concrete [grade C30] as shown in Drawing No.(). m3 m3 m3 m3 m3 m3 m3 m3 m3 m3
R700
INSTRUMENTATION Rate for instrumentation shall include all provision as expressly required in Specification clause ().
Convergence measurement. Settlement measurement. Stress measurement with strain gauges. Stress measurement with pressure cells. Inclinometer. Stress measurement with pneumatic piezometer.
nr nr nr nr nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
S112
m2
S113 S120
m2 m2
S130
m2
S140
m2
S150
m3
S160
m3
S200
SUPPLYING Item for supplying shall be deemed to include delivery of components to the Site.
S210
Flat bottom rails, [reference 113A] as per Specification clause (.), mass [56 kg/m]. Check and guard rails, mass 0.10 tonne/m as per Specification clause (.). Conductor rails as per Specification clause (.). Twist rails.
S220
S230 S240
t nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
S252
nr
Fittings Item for supplying fittings shall be deemed to include fixings, keys, clips, bolts, nuts, screws, spikes, ferrules, track circuit insulators, pads, conductor rail insulator, and packing. S261 S262 Type (.) chairs as per Specification clause (). Type (.) baseplates as per Specification clause (). nr nr
S263
[Pandrol] rail fastenings, type [.] as per Specification clause (). Type (.) plain fishplates as per Specification clause (). Type (.) plain insulated fishplates as per Specification clause (). Conductor rail insulators as per Specification clause (.). Conductor rail side ramps. SUPPLYING Item for supplying shall be deemed to include delivery of components to the Site.
nr
S264
nr
S265
nr
S266
nr
S267 S300
nr
S310
Type [..] turnouts as shown in Drawing No. (.). Rate to include timbers, fittings, and check rails.
nr
S320
Type [..] diamond crossing as shown in Drawing No. (.). Rate to include timbers, fittings, and check rails.
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
nr nr nr nr
S400
LAYING Item for laying shall be deemed to include work carried out after delivery of components to the Site or where track is not to be supplied by the Contractor, to the location stated in Specification clause ().
Flat Bottom Rails S411 Plain track, rail reference 113A, mass 56 kg/m and prefabriacted in [10m] length, fish plated joints on timber sleepers. Form curve in plain track radius not exceeding 300 m, welded joints on concrete sleepers Form curve in plain track radius exceeding 300 m, fishplated joints on timber sleepers. Turnouts type [..] as shown on Drawing No. (.), length [.] m, fishplated joints on timber sleepers. m
S412
S413
S414
nr
S415
Diamond crossings type [..] as shown on Drawing No. (.), length [.] m, fishplated joints on timber sleepers.
nr
S416
Welded joints by quick thermit process as per Specification clause (.). Spot re-sleepering. Check and Guard Rails
nr
S417
nr
Rail. Length ends. Side ramps. Welded joints by quick thermit process as per Specification clause (.).
m nr nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
nr nr nr m
S500
DISMANTLING Dismantling shall include taking up, lifting, packing and slewing, and to include opening out, packing and boxing in with ballast and insertion of closure rails.
Flat Bottom Rails S511 Plain trackrail reference 113A, mass 56 kg/m, fish plated joints on timber sleepers. Dismatled material shall be stored at [storage yard at main site office]. m
S512
Turnouts type [..], length [.] m, fishplated joints on timber sleepers. Rate to include checkrail, guardrail, and conductor rails. Diamond crossings type [..], length [.] m, fishplated joints on timber sleepers. Rate to include checkrail, guardrail, and conductor rails. Check and guard rails. Conductor rails.
nr
S513
nr
S520 S530
m m
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
nr nr nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
T110
[1200 mm wide x 25 mm thick close boarded wrot finish Grade A balau heavy hardwood complete with 150 mm x 150 mm posts at 3 m centres, 1.80 m high] as shown in Drawing No. (). [40 x 40 x 2.6 mm thick square mild steel hollow section at 100 mm centres bothways welded as a frame 1.5 m high with 80 x 80 x 3.6 mm thick post at 2 m centres] as shown in Drawing No. (.). [3 mm] diameter [PVC-coated galvanised] mild steel wire of [50 mm] square mesh, [2 m] overall height chain link fencing complete with post at [3 m] centres as shown in Drawing No. (.). Rate to include all posts, raked angle, straining wires, barb wires, concrete kerbs, and foundations as shown.
T120
T130
Barb/Bladed Wire T140 [12 SWG galvanised mild steel] barbed/bladed wire fencing; [1.2 m] high with [50 x 50 x 4.5 mm thick] mild steel angle as post planted in mass concrete bases at [2.0 m] centres and including [150 mm high] concrete kerb as shown in Drawing No. (..). [Brick and mild steel grille fencing; comprising 500 mm high, 115 mm thick brick wall with concrete coping rendered with 19 mm thick cement sand plaster; 230 mm x 230 mm brickwork post; mild steel decorative grille fencing 750 mm high; framed and welded together, all on and including reinforced concrete strip footing as shown in Drawing No. (.....)]. m
T150
T200
GATES Items for gates shall be deemed to include excavation, preparation of surfaces, disposal of excavated material, upholding sides of excavation, backfilling, concrete, formwork, reinforcement, posts and foundations, hinges, bolts, rollers, lockplates, and all necessary welding.
T210
Double leave Grade A balau heavy hardwood gate [2400 mm x 1500 mm high] overall complete with [100 mm x 100 mm] hardwood posts and ironmongery as shown in Drawing No. ().
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
T220.2
Single leaf mild steel automatic gate [3000 mm x 1500 mm high], consisting of [50 x 30 x 3.2 mm thick] rectangular hollow section as frame welded together with [30 x 30 x 2.6 mm thick] square hollow section; including painting, ironmongery; fixing with hinges on lugs built in masonry backing as shown in Drawing No. (........). Rate to include motor and automatic control system.
nr
Chain Link Item for chain link shall be deemed to include all posts, raked angle, straining wires, barb wires, kerbs where applicable and their foundation. T230 [3 mm] diameter [PVC-costed galvanised mild steel wire of 50 mm square mesh, [3.0 m wide x 2.5 m overall height double leave chain link gate with 60.3 mm OD x 5 mm thick circular hollow section as frame as shown in Drawing No. (.....). Rate to include all posts, hinges, bolts, lock plates, angle braces, barb wires, all necessary welding and foundations as shown. nr
T240
Double leave galvanised barbed wire [2400 mm x 2000 mm high] gates; comprising [50 x 50 x 4.5 mm thick] mild steel angle frame as shown in Drawing No (..). Double leave gate, [2400 mm x 1200 mm high] with 100 mm x 100 mm Grade A wrot finish heavy hardwood as frame and 12 SWG galvanised barbed wire as shown in Drawing No. (.).
nr
T250
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
T310.2
nr
External Signages T320 Paint lettering for [water tank] at [Taman Gembira Cheras] as per Specification clause (.) and detailed in Drawing No. (.). Internal Signage Internal signage shall be as per Specification clause (). T330.1 T330.2 T330.3 T400 Laboratory. Work manager room. Control room. BEARING PADS Bridge bearing Supply and install the following bearings inclusive of mortar grout, epoxy mortar, and all temporary work. nr nr nr nr
T411.2
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
Rocker T413.1 Cylindrical rocker bearing as shown in Drawing No. (..). Spherical rocker bearing as shown in Drawing No. (..). nr
T413.2
nr
Plain rubber T414 [300 x 300 x 60 mm thick] plain rubber bearing as shown in Drawing No. (..). Laminated rubber T415 [300 x 300 x 80 mm thick] elastomer laminated rubber bearing as shown in Drawing No. (..). Pot bearing T416.1 Sliding guided pot bearing as shown in Drawing No. (..). Free standing pot bearing as shown in Drawing No. (..). Other bearing T424 300 mm wide x 60 mm thick plain rubber bearing for joint between dome roof and wall as shown in Drawing No. (..). nr nr nr nr
T416.2
nr
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office
\\vboxsrv\conversion_tmp\scratch_6\167229266.xls.ms_office