Professional Documents
Culture Documents
The BG-6 64 is a miniatu ure, low-cost, , flexible redu undant ADM-64/MADM-1 16 MSPP for access net tworks, offere ed as part of the t overall EC CI Telecom so olution. It sup pports interopera ability with th he XDM Prod duct Line and BG Product L Line in all asp pects, including SDH, PDH, data, d DCC, m management, and a other net-wide functio ons.
Two power p supply (INF_64) mo odule slots One MCP64 M slot Two XIO64 X card sl lots One fa an unit (FCU_ _64) slot Seven n traffic card slots s (Tslots)
The BG-6 64 can be insta alled in 2,200 0 mm or 2,600 0 mm ETSI racks, or in 19 9 racks. The BG-6 64 is fed by -4 48 VDC powe er sources. Tw wo INF-64 m modules can be e configured in i two power supply mod dule slots for redundant r pow wer supply. The BG-6 64 subrack can n be expanded via expansi ion shelf, the BG-30E. Thi is is the same expansion n shelf used to o expand the B BG-30B. The e BG-30E she elf contains tw wo power supplies, a fan unit, and d three tributa ary slots.. The follow wing table list ts the module es that can be configured in n each slot in the BG-64.
Table Error! No text of sp pecified style in n document.-1: BG-64 cards and modules Name Descr ription MS XS S A& &B TS1 to TS7 PS A&B
Main control card Cross-connect, timin ng control, erface card and 1 x STM-64 inte Cross-connect, timin ng control, and 4 x STM-16 inte erface card 2 x ST TM-1o/e modu ule 1 x ST TM-4 module
Name
Description
MS
XS A&B
TS1 to TS7
PS A&B
SMQ1&4 SMS16 PME1_211 PM345_3 DMFE_4_L1 DMFX_4_L1 DMFE_4_L2 DMFX_4_L2 DMGE_4_L1 DMGE_2_L2 DMGE_4_L2 DMEoP_4
4 x STM-1/4 module 1 x STM-16 module 21 x E1 module, 120 3 x DS-3/E3 module 4 x 10/100BaseT module, L1 functionality 4 x 100Base-FX module, L1 functionality 4 x 10/100BaseT module, L2 functionality (MPLS ready) 4 x 100Base-FX module, L1 functionality (MPLS ready) 4 x GbE module, L1 functionality 2 x GbE module, L2 functionality with MPLS support 4 x GbE module, L2 functionality with MPLS support 4 x EoP module with total WAN bandwidth of 32 x E1 and L2 functionality Power filter unit (-48 VDC)
INF_64
BG-30E Overview
The BG-30E shelf is housed in a 240 mm deep, 465 mm wide, and 88 mm high equipment cage with all interfaces accessible from the front. The shelf consists of three expansion cards, redundant power feed modules, and an extractable fan module. All cards in the BG-30E are connected using a backplane that supports one traffic connector for the connection between the BG-30E and the BG-30B or BG-64. NOTE: the BG-30E can be used to expand traffic for the BG30B and BG-64 shelves. All information described for the BG-30E is applicable for both shelves.
This module/card can provide only balanced E1 interfaces directly. For unbalanced E1 interfaces, an external DDF with balanced-to-unbalanced conversion should be used.
A BG-30E shelf is an extension or slave unit of the BG-30B or BG-64 and should always be connected to one of these shelves. The fan unit, used to cool the system, is extractable and located on the right side of the shelf. The fan control system is on the MCP30 or MCP64 in accordance with the type of shelf it is being installed on.
The BG-30E houses three traffic expansion slots supporting different types of PDH, SDH, data, and PCM interface expansion cards. Either 220 VAC or -48 VDC power feeds can be selected. BG-30E has one slot that is used for configuring the power input module. Two types can be configured: INF_30E and AC_CONV-30E:
|
INF_30E, used for -48 VDC power feed, provides two D-type connectors for external power line connection, and supports dual power feed. AC_CONV-30E is used for 220 VAC power feed to implement AC/DC conversion. It supports external power line connection through a special power connector. NOTE: Adding a BG-30E expansion unit to a working BG30B in the field is a non-traffic-affecting operation.
ES1
ES2
ES3
PS
PE1_63
63 x E1 card, 120 3 x DS-3/E3 card L2 card supporting 2 x GbE combo ports and 8 x 10/100BaseT ports, MPLS feature and up to 64 EoS/MoT ports with total bandwidth of 4 x VC-4
P345_3E MPS_2G_8F
This module/card can provide only balanced E1 interfaces directly. For unbalanced E1 interfaces, an external DDF with balanced-to-unbalanced conversion should be used.
Name
Description
ES1
ES2
ES3
PS
SM_10E