You are on page 1of 5

Jameco SKU Number: 2104022

45W Triple Output Medical Type


Features :
Universal AC input / Full range Low leakage current 0.3mA Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty

M P T- 4 5

series

EN60601-1 IEC60601-1

SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT POWER (max.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION
(Note 4)

MPT-45A CH1 5V 3A 0.4 ~ 5A 40.5W 120mVp-p 7.0% 2.0% 4.0% 60mVp-p 5.0% 1.0% 1.0% CH2 12V 2A 0.2 ~ 2.5A CH3 -5V 0.3A 0 ~ 0.5A

MPT-45B CH1 5V 3A 0.4 ~ 5A 42.6W 60mVp-p 4.0% 1.0% 3.0% 120mVp-p 7.0% 2.0% 4.0% 100mVp-p 5.0% 1.0% 1.0% CH2 12V 2A 0.2 ~ 2.5A CH3 -12V 0.3A 0 ~ 0.5A

MPT-45C CH1 5V 3A 0.4 ~ 5A 43.5W 60mVp-p 4.0% 1.0% 3.0% 120mVp-p 7.0% 2.0% 4.0% 100mVp-p 5.0% 1.0% 1.0% CH2 15V 1.6A 0.2 ~ 2.3A CH3 -15V 0.3A 0 ~ 0.5A

52W with 18CFM min. Forced air convection CH1:4.5 ~ 5.5V 4.0% 1.0% 3.0% 80ms/230VAC 90 ~ 264VAC 47 ~ 440Hz 73% 1.2A/115VAC 0.7A/230VAC 40A/230VAC COLD START 20A/115VAC <0.3mA / 264VAC 75% 75%

RIPPLE & NOISE (max.) Note.2 60mVp-p

800ms, 20ms/230VAC

800ms, 20ms/115VAC at full load

12ms/115VAC at full load 127 ~ 370VDC

53 ~ 75W rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75VDC on CH1 Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL2601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min. I/P-O/P, I/P-FG:100M Ohms/500VDC Compliance to EN55011 (CISPR11) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN60601-1-2, medical level, criteria A 271.5Khrs min. MIL-HDBK-217F (25 127*76*28mm (L*W*H) 0.21Kg; 72pcs/18Kg/1.35CUFT )

HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS


NOTE

DIMENSION PACKING

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Mounting holes M1 and M2 should be grounded for EMI purposes.

File Name:MPT-45-SPEC 2008-03-25

Jameco SKU Number: 2104022


45W Triple Output Medical Type
Mechanical Specification
127 115.8 5.6

M P T- 4 5

series

Unit:mm

5.6

FG M1 M2

CN2

64.8

FS1

AC FUSE T2A/250V 1 2

1 2 3 4 5 6

76

CN1

FS2

AC FUSE T2A/250V

SVR1

4-

3.

2 max.

28

DC Output Connector (CN2) : Molex 5273-06 or equivalent


Terminal Molex 5194 or equivalent Pin No. Assignment 1 +V 2,3 +5V 4,5 COM 6 -V RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. Mating Housing Molex 5195 or equivalent Terminal Molex 5194 or equivalent

AC Input Connector (CN1) : Molex 5277-02 or equivalent


Pin No. 1 2 Assignment AC/N AC/L Mating Housing Molex 5195 or equivalent

Block Diagram
+V I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING

fosc : 45KHz

+5V COM -V

FG

O.L.P.

PWM CONTROL

Derating Curve

Static Characteristics

100

100 90

80

80 70

60

LOAD (%)

40

LOAD(%)
0 10 20 30 40 50 60 (HORIZONTAL)

60 50 40

20

-10

90

100

110

135

155

230 264

AMBIENT TEMPERATURE ( )

INPUT VOLTAGE (V) 60Hz

File Name:MPT-45-SPEC 2008-03-25

Quality Engineering Test Report


SERIES: MPT-45 45W TRIPLE OUTPUT SWITCHING POWER SUPPLY SAMPLE: A.MPT-45A: V1: V2: V3: 5V/3A 12V/2A -5V/0.3A B.MPT-45B: V1: V2: V3: 5V/3A 12V/2A -12V/0.3A C.MPT-45C: V1: V2: V3: 5V/3A 15V/1.6A -15V/0.3A

NO
1

TEST ITEM

TEST CONDITION/SPECIFICATION
SPEC: 90~264VAC

RESULT
A: 54.812V ~ 264 V B: 54.943V ~ 264 V C: 58.881V ~ 264 V A:V1: V2: -0.24 % ~ +0.00 -0.05 % ~ %

VERDICT
P

I/P: TESTING AC INPUT VOLTAGE RANGE O/P: FULL LOAD I/P: 90~264VAC O/P: FULL LOAD

SPEC: A: V1:1% V2:2% V3:1% B: V1:1% V2:2% V3:1% C: V1:1% V2:2% V3:1% +0.56 % +0.00 % +0.00 % +0.62 % +0.00 % +0 % +0.79 % +0 % P

V3: +0.00 % ~ B:V1: -0.237 % ~ V2: -0.049 % ~ V3: +0.00 % ~ C:V1: -0.238 % ~ V2: V3: -0.04 % ~ +0 % ~

LINE REGULATION

I/P: 230VAC O/P: MIN. TO MAX.LOAD

SPEC: A: V1:3% V2:4% V3:1% B: V1:3% V2:4% V3:1% C: V1:3% V2:4% V3:1% A:V1: V2: V3: B:V1: V3: C:V1: V2: V3: -0.24 % ~ -0.05 % ~ +0.00 % ~ +0.12 % +0.26 % +0.00 % P

-0.355 % ~ +0.118 % -0.049 % ~ +0.049 % -0.237 % ~ +0.118 % -0.417 % ~ +0.458 % -0.00 % ~ +0.00 %

LOAD REGULATION

V2: +0.049 % ~ +0.207 %

I/P: 90~264VAC O/P: 20% TO MAX.LOAD

OUTPUT VOLTAGE TOLERANCE

SPEC: A: V1:4% V2:7% V3:5% B: V1:4% V2:7% V3:5% C: V1:4% V2:7% V3:5%

A:V1: V2: V3: V2: V3:

-1.37 % ~ +0.00 % ~ -0.08 % ~

+0.99 % +0.26 % +0.00 % P

B:V1: -1.479 % ~ +0.868 % -2.38 % ~ +3.578 % +0.00 % ~ +0.204 % +0.87 % +5.32 %

C:V1: -1.977 % ~ V2: -2.158 % ~ V3:

-0.00 % ~ +0.078 %

I/P: 230VAC O/P: FULL LOAD

SPEC: A: V1:60mV V2:120mV V3:60mV B: V1:60mV V2:120mV V3:100mV C: V1:60mV V2:120mV V3:100mV

V1: 6mV 28mV 8mV V2: 9mV 24mV 9mV V3: 21mV 78mV 6mV P

RIPPLENOISE

NO TEST ITEM
6 AC INPUT CURRENT

TEST CONDITION / SPECIFICATION


I/P: 230VAC O/P: FULL LOAD SPEC: 0.7A A: B: C: I/P: 230VAC SPEC:40A A:

RESULT
0.511A 0.518A 0.534A 27.9A

VERDICT
P

MAX. INRUSH CURREN

O/P: FULL LOAD COLD START

B: 36.414A C: 28.546A A: 4.41 V~ 4.27 V~ 4.223 V~ 6.02 V 5.97 V 6.45 V SPEC: 4.5V~5.5V

O/P VOLTAGE ADJ.RANGE

I/P: 230VAC O/P: MIN. LOAD I/P: 230VAC O/P: FULL LOAD I/P: 230VAC\60Hz O/P: FULL LOAD I/P: 230VAC

B: C:

SET UP TIME

SPEC: 800mS

10 HOLD UP TIME

SPEC: 20mS

A: 117.5mS B: 268.1mS C: 270.4mS A: 7.56mS B: 8.65mS C:10.664mS A: 74.26% B: 76.2% C: 76.4% A: 68% B: 64% C: 60.1% A: 6.24V B: 6.12V C: 6.239V 14mOhms I /P-O/P: >100MOhms I /P-FG : >100MOhms >100MOhms O /P-FG

SPEC: A: B: C:

73 % 75 % 75 %

11 EFFICIENCY

12

OVER LOAD PROTECTION OVER VOLTAGE PROTECTION GROUNDING CONTINUITY

I/P: 230VAC O/P: TESTING I/P: 230VAC O/P: TESTING SPEC:

SPEC: 53W~75W

13 14

SPEC:ON CH1 5.75V~6.75V

P P

FG--CHASSIS<0.1Ohms/2min

A: SPEC: INSULATION 15 RESISTANCE I/P-O/P: 500VDC/100MOhms MIN. I/P-FG: 500VDC/100MOhms MIN. O/P-FG: 500VDC/100MOhms MIN.

I /P-O/P: >100MOhms I /P-FG : >100MOhms B: >100MOhms O /P-FG C: I /P-O/P: >100MOhms I /P-FG : >100MOhms >100MOhms O /P-FG I/P-O/P A: I/P-FG :1.74mA :0.723mA

O/P-FG :3.03mA SPEC: DIELECTRIC / 16 WITHSTAND VOLTAGE I/P-O/P: 4000VAC/ 1 MIN(10mA CUT-OFF) I/P-FG: 1500VAC/ 1 MIN(10mA CUT-OFF) O/P-FG: 500VAC/ 1 MIN(10mA CUT-OFF) I/P-O/P B: I/P-FG :2.19mA :1.47mA P

O/P-FG : 2.93mA I/P-O/P C: I/P-FG :2.243mA :1.46mA

O/P-FG :3.47mA 17 BURNIN TEST I/P: 230VAC O/P:FULL LOAD TA:23.1C BURN-IN DURATION:1hrs 1.LOW TEMPERATURE TEST I/P:230VAC O/P:FULL LOAD AFTER 1hrs POWER ON OK AMBIENT TEMPERATURE:-9.6C 2.HIGH AMBIENT TEMPERATURE FULL LOAD TEST ENVIRONMENT 18 TEST I/P:230 VAC O/P:FULL LOAD AFTER 12hrs NON BREAK P AMBIENT TEMPERATURE:32.1C 3.ACCELERATED LIFE TEST I/P:272 VAC O/P:FULL LOAD AMBIENT TEMPERATURE:25C AMBIENT HUMIDITY:95% AFTER13hrs POWER ON/OFF OK NO BREAK P

NO

TEST ITEM

TEST CONDITION/SPECIFICATION
I/P :230VAC O/P :FULL LOAD POSITION BD1 Q1 T1 D6 D4 D5 L1 R6 D1 C21 C5 LF1 AFTER 1hrs BURN-IN TA:23.1C TEMP 62.3C 70.0C 66.6C 70.9C 85.8C 80.1C 69.4C 64.4C 69.6C 66.8C 42.8C 48.0C

RESULT

VERDICT

19

TEMPERATURE RISE T rise OF PARTS

P/N BRIDGE DIODE MAIN TRANSISTER MAIN TRANSFORMER COIL V1 O/P DIODE V2 O/P DIODE V3 O/P DIODE O/P CHOCK SNAB R CLAMP DIODE O/P FILTER CAPACITOR I/P FILTER CAPACITOR LINE FILTER TRANFORMER

T rise 39.2C 46.9C 43.5C 47.8C 62.7C 57.0C 46.3C 41.3C 46.5C 43.7C 19.7C 24.9C

SUPPOSE C21IS THE MOST CRITICAL COMPONENT 20 LIFE CYCLE I/P:230VAC O/P:FULLLOAD Ta:25C Tc21:66.6C Life time:57445 hrs I/P:230VAC O/P:FULLLOAD Ta:30C Tc21:75C Life time:37120hrs FUSE BRIDGE DIODE CRITICAL COMPONENT RECORD ( FOR QC INSPECTION REFERENCE ONLY ) LINE FILTER TRANSFOMER POWER SWITCHER OUTPUT DIODE OUTPUT CAPACITOR INPUT CAPACITOR P.C.B : 4AL/250V UL : D3SB60 : TF484-R1 ET-20V : TF586 : 2SK2545 :MR1545CT : RUYCON 1200uf/16V 105C ZL :HITACHI 100 uf/400V 85C HP3 : MPT-65-R3 P

21

DATE

SAMPLE RD SAMPLE MPT-45A MPT-45B MPT-45C PORDUCTION SAMPLE A109C24 MPT-45A MPT-45B MPT-45C PORDUCTION SAMPLE A112A10 MPT-45B PORDUCTION SAMPLE A207B17 MPT-45C

TEST RESULT

TEST

APPROVAL

20010910

PASS

VINCENT

Max Lin

20011105

PASS

VINCENT

Max Lin

20020120

PASS

VINCENT

Max Lin

20020905

PASS

VINCENT

Max Lin