You are on page 1of 2

PILE BEARING CAPACITY CALCULATION BASED ON S.P.T.

VALUE
------------------ -----------------Project Name :
Location
:
BH-1
Borehole No. :
Date
:
------------------ -----------------MAYERHOF Formula :
K1
2.0
Skin, Ps
=
K1 x Nav x As
SAND
2.5
Bearing, Pb =
K2 x Nb x Ab
SILT
3.0
Ult. Load, Pu =
Ps + Pb
CLAY
All. Load, Pa =
Ps/Fs + Pb/Fb
Factor of safety :

Skin, Fs
=
Bearing, Fb =

------------------ -----------------To calculate allowable soil bearing capacity :


Pile used :
Type
:
(c = circular)
Width, b =
(s = square)
(= dia. for type c)

K2
400
250
100

2
3

s
0.4

Perimeter:
Ab:
Qa(conc):

1.600
0.160
1800

========== ========== ====== ========== ========== ============ =======================


Depth
Soil
SPT
Skin
Total
Base
Working Load
Type
N
As
Fric
Skin
Load
Fs = 2.0 Fb = 3
(m)
(m)
(kN)
(kN)
(kN)
(KN)
------------------ ------------------ ---------- ------------------ ------------------ -------------------- --------------------------------------0.0
1.5
3.0
4.5
6.0
7.5
9.0
10.5
12.0
13.5
15.0
16.5
18.0
19.5
21.0
22.5
24.0
25.5
27.0
28.5
30.0
31.5
33.0
34.5
36.0
37.5
39.0
40.5
42.0
43.5
45.0
46.5

SAND
SAND
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT

0
16
18
11
15
16
20
19
22
21
24
17
20
18
21
21
23
25
31
33
35
26
30
32
36
38
50

11
9
13
15
17

0.0
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

0.0
76.8
108.0
66.0
90.0
96.0
120.0
114.0
132.0
126.0
144.0
102.0
120.0
108.0
126.0
126.0
138.0
150.0
186.0
198.0
210.0
156.0
180.0
192.0
216.0
228.0
300.0
66.0
54.0
78.0
90.0
102.0

0.0
76.8
184.8
250.8
340.8
436.8
556.8
670.8
802.8
928.8
1,072.8
1,174.8
1,294.8
1,402.8
1,528.8
1,654.8
1,792.8
1,942.8
2,128.8
2,326.8
2,536.8
2,692.8
2,872.8
3,064.8
3,280.8
3,508.8
3,808.8
3,874.8
3,928.8
4,006.8
4,096.8
4,198.8

0.0
1,024.0
720.0
440.0
600.0
640.0
800.0
760.0
880.0
840.0
960.0
680.0
800.0
720.0
840.0
840.0
920.0
1,000.0
1,240.0
1,320.0
1,400.0
1,040.0
1,200.0
1,280.0
1,440.0
1,520.0
2,000.0
440.0
360.0
520.0
600.0
680.0

0.0
379.7
332.4
272.1
370.4
431.7
545.1
588.7
694.7
744.4
856.4
814.1
914.1
941.4
1,044.4
1,107.4
1,203.1
1,304.7
1,477.7
1,603.4
1,735.1
1,693.1
1,836.4
1,959.1
2,120.4
2,261.1
2,571.1
2,084.1
2,084.4
2,176.7
2,248.4
2,326.1

For a designed load of 100 KN, the estimated depth is 16.5m.


Note : 1. The clay skin friction for the top soil layer is assume to be 7.5kN/m2
2. The pile is designed as floating pile where the pile would settle together with the soil and therefore there
is no effective negetive skin friction.
3. The final depth of piles penetration shall be decided on site by load test.

PILE BEARING CAPACITY CALCULATION BASED ON S.P.T. VALUE


------------------ -----------------Project Name :
Location
:
BH-1
Borehole No. :
Date
:
------------------ -----------------MAYERHOF Formula :
K1
2.0
Skin, Ps
=
K1 x Nav x As
SAND
2.5
Bearing, Pb =
K2 x Nb x Ab
SILT
3.0
Ult. Load, Pu =
Ps + Pb
CLAY
All. Load, Pa =
Ps/Fs + Pb/Fb
Factor of safety :

Skin, Fs
=
Bearing, Fb =

------------------ -----------------To calculate allowable soil bearing capacity :


Pile used :
Type
:
(c = circular)
Width, b =
(s = square)
(= dia. for type c)

K2
400
250
100

2
3

s
0.4

Perimeter:
Ab:
Qa(conc):

1.600
0.160
1800

========== ========== ====== ========== ========== ============ =======================


Depth
Soil
SPT
Skin
Total
Base
Working Load
Type
N
As
Fric
Skin
Load
Fs = 2.0 Fb = 3
(m)
(m)
(kN)
(kN)
(kN)
(KN)
------------------ ------------------ ---------- ------------------ ------------------ -------------------- --------------------------------------0.0
1.5
3.0
4.5
6.0
7.5
9.0
10.5
12.0
13.5
15.0
16.5
18.0
19.5
21.0
22.5
24.0
25.5
27.0
28.5
30.0
31.5
33.0
34.5
36.0
37.5
39.0
40.5
42.0
43.5
45.0
46.5

SAND
SAND
SAND
SAND
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT
SILT

0
11
12
15
17
19
19
17
19
11
18
17
19
20
18
14
0
22
20
20
22
25
23
23
24
23
25
26
50

0.0
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4

0.0
52.8
57.6
72.0
102.0
114.0
114.0
102.0
114.0
66.0
108.0
102.0
114.0
120.0
108.0
84.0
0.0
132.0
120.0
120.0
132.0
150.0
138.0
138.0
144.0
138.0
150.0
156.0
300.0
0.0
0.0
0.0

0.0
52.8
110.4
182.4
284.4
398.4
512.4
614.4
728.4
794.4
902.4
1,004.4
1,118.4
1,238.4
1,346.4
1,430.4
1,430.4
1,562.4
1,682.4
1,802.4
1,934.4
2,084.4
2,222.4
2,360.4
2,504.4
2,642.4
2,792.4
2,948.4
3,248.4
3,248.4
3,248.4
3,248.4

0.0
704.0
768.0
960.0
680.0
760.0
760.0
680.0
760.0
440.0
720.0
680.0
760.0
800.0
720.0
560.0
0.0
880.0
800.0
800.0
880.0
1,000.0
920.0
920.0
960.0
920.0
1,000.0
1,040.0
2,000.0
0.0
0.0
0.0

0.0
261.1
311.2
411.2
368.9
452.5
509.5
533.9
617.5
543.9
691.2
728.9
812.5
885.9
913.2
901.9
715.2
1,074.5
1,107.9
1,167.9
1,260.5
1,375.5
1,417.9
1,486.9
1,572.2
1,627.9
1,729.5
1,820.9
2,290.9
1,624.2
1,624.2
1,624.2

For a designed load of 100 KN, the estimated depth is 16.5m.


Note : 1. The clay skin friction for the top soil layer is assume to be 7.5kN/m2
2. The pile is designed as floating pile where the pile would settle together with the soil and therefore there
is no effective negetive skin friction.
3. The final depth of piles penetration shall be decided on site by load test.

You might also like