You are on page 1of 2

DESIGNCALCULATIONS Ref.No.

TQDC20131 Date:17March2013

ROUGHCALCULATIONSCHECKFORLIGHTPOLEFOUNDATION:
1.Thiscalculationisbasedona22mhighpolewith750mmdia.baseshowninDwg.5089236/008/SL/1313. Topdiameteroftaperedcircularpoleisassumedas250mmforpurposesofcalculatingprojectedarea. Otherpoleconfigurationswithequivalentprojectedareamaybeused. 2.Resultantwindforcesonelements,fixturesandfixingsonthepoleareapproximateintheabsenceof specificdataoneffectiveprojectedareas(EPAs)fromthepoleandfixturesmanufacturer. 3.Netwindpressureisassumedat1KN/m2

P4

P3

P1= 11 KN(pole) P2= 5 KN(banner) P3= 0.5 KN(streetlight) P4= 1 KN(eventlighting) V= 18 KN

20m

22m

P1 P2 12m

7.33m 6.2m

Prepared:RN Page1

DESIGNCALCULATIONS Ref.No.TQDC20131 Date:17March2013

OVERTURNINGMOMENT: M= P1(7.33)+P2(6.2)+P3(12)+P4(20) M= 140 KNm FACTOREDMOMENT: MF= 279 KNm (consideringafactorofsafetyof2)

SHEARLOADATTHEBASE: V= 17.5 KN FACTOREDSHEAR V F = 35 KN (consideringafactorofsafetyof2)

MOMENTTOSHEARRATIO: H= MF/VF H= 7.98 m

COEFFICIENTq: q= VF/9cD q= 0.005 m

where:
2 c= shearstrengthofsoil(KN/m ) c= 492

D= widthordiameteroffoundation(m) D= 1.5 BYBROMS'DESIGNMETHOD: REQUIREDEMBEDMENTDEPTH: 4H+6D L= 1.5D+q1+2+ q 2.72 m < 3m (OK!)

CHECKALLOWABLEMAXIMUMMOMENT: MFmax= VF(H+1.5D+0.5q) MFmax= 358 KNm > 279 KNm(OK!)

BASEDONTHEABOVEROUGHCALCULATIONS, DIA.1.5mx3mDEEPAUGERPILEFOUNDATIONFOR22mHIGHLIGHTMASTISADEQUATE. AMOREDETAILEDDESIGNSHALLBECARRIEDOUTBYTHEDESIGNENGINEERBASEDONSPECIFIC DESIGNDATAI.E.,EPAs,SOIL&FOUNDATIONCHARACTERISTICSANDALLPROJECTREQUIREMENTS.

Prepared:RN Page2