Parameter name Inter-frequency Measure Report Mode Inter-frequency Measure Filter Coeff Inter-frequency Measure Periodical Measurement Report

Period 2B Hysteresis 2D Hysteresis 2F Hysteresis HHO Hysteresis Weight for Used frequency Event 2B Trigger Delay Event 2D Trigger Delay Event 2F Trigger Delay HHO Period Trigger Delay Inter-freq CS Measure Start Ec/No THD Inter-freq CS Measure Stop Ec/No THD Inter-freq R99 PS Measure Start Ec/No THD Inter-freq H Measure Start Ec/No THD Inter-freq R99 PS Measure Stop Ec/No THD Inter-freq H Measure Stop Ec/No THD Inter-freq CS Measure Start RSCP THD Inter-freq CS Measure Stop RSCP THD Inter-freq R99 PS Measure Start RSCP THD Inter-freq H Measure Start RSCP THD Inter-freq R99 PS Measure Stop RSCP THD Inter-freq H Measure Stop RSCP THD Inter-freq CS Target Frequency Trigger Ec/No THD Inter-freq R99 PS Target Frequency Trigger Ec/No THD

vallue Periodical reporting D3 D500 <NULL> 4 4 0 0 <NULL> D320 D1280 0 -18 -16 -18

-18 -16 -16 -115 -113 -115 -115 -113 -113 -16 -16

Inter-freq HSPA Target Frequency Trigger Ec/No THD Inter-freq CS Target Freqency Trigger RSCP THD Inter-freq R99 PS Target Frequency Trigger RSCP THD Inter-freq HSPA Target Freqency Trigger RSCP THD Inter-freq CS Used frequency trigger Ec/No THD Inter-freq R99 PS Used frequency trigger Ec/No THD Inter-freq H Used frequency trigger Ec/No THD Inter-freq CS Used frequency trigger RSCP THD Inter-freq R99 PS Used frequency trigger RSCP THD Inter-freq H Used frequency trigger RSCP THD Inter-freq Measure Timer Length 2B Event Retry Period 2B Event Retry Max Times Inter-freq Coverage Handover Trigger Delay

-16 -113 -113 -113 -16 -16 -16 -113 -113 -113 60 <NULL> <NULL> 0

Parameter Intra-frequency L3 Filter Coefficient Intra-frequency Measurement Quantity Event 1A to Periodical Report Number Event 1A to Periodical Report Period Event 1C to Periodical Report Number Event 1C to Periodical Report Period Event 1J to Periodical Report Number Event 1J to Periodical Report Period VP Service Event 1A Relative Threshold CS Non-VP Service Event 1A Relative THD PS Service Event 1A Relative Threshold VP Service Event 1B Relative Threshold CS Non-VP Service Event 1B Relative Threshold PS Service Event 1B Relative Threshold Event 1F Absolute Ec/No Threshold Event 1F Absolute RSCP Threshold

value D3

CPICH_EC/NO

D16

D4000

D16

D4000

D64

D1000

10

10

10

-24

<NULL>

1A Hysteresis 1B Hysteresis 1C Hysteresis 1D Hysteresis 1F Hysteresis 1J Hysteresis Weighted factor Event 1A Triggering Delay Event 1B Triggering Delay Event 1C Triggering Delay Event 1D Triggering Delay Event 1F Triggering Delay

0 0 8 8 8 8 0

D320

D640

D640

D640

D640

Event 1J Triggering Delay Max Evaluation Period of SHO Failure Threshold Number of SHO Failure Relative Threshold of SHO Failure Period of Penalty Timer for SHO Failure After Down Rate Min Quality THD for SHO

D640

60

30

-24

Max Number of Cell in Active Set Event 1F Blind Handover Trigger Condition -115 3

Intra-Frequency Measurement Report Interval D250 of Blind HO Intra-Frequency Masurement Report Amount of Blind Handover

D2

Parameter Inter-RAT Report Mode 2D/2F Filter Coefficient 3A Measure Quantity Inter-RAT Filter Coefficient Weight for Used Frequency Inter-RAT Period Reporting Interval 2D Hysteresis 2F Hysteresis 3A Hysteresis Inter-RAT Hysteresis 2D Event Trigger Delay Time 2F Event Trigger Delay Time 3A Event Trigger Delay Time Time to Trigger Handover to NonVerified GSM Cell Time to Trigger Handover to Verified GSM Cell BSIC Verify Switch

Value Periodical reporting

D3

<NULL>

D3

D1000

<NULL>

D320

D1280

<NULL>

Verify mode

Inter-RAT CS Measure Start -14 Ec/No THD

Inter-RAT CS Measure Stop Ec/No THD Inter-RAT R99 PS Measure Start Ec/No THD Inter-RAT HSPA Measure Start Ec/No THD Inter-RAT R99 PS Measure Stop Ec/No THD Inter-RAT HSPA Measure Stop Ec/No THD Inter-RAT CS Measure Start RSCP THD Inter-RAT CS Measure Stop RSCP THD Inter-RAT R99 PS Measure Start RSCP THD Inter-RAT HSPA Measure Start RSCP THD Inter-RAT R99 PS Measure Stop RSCP THD Inter-RAT HSPA Measure Stop RSCP THD Inter-RAT CS Handover Decision THD Inter-RAT R99 PS Handover Decision THD Inter-RAT HSPA Handover Decision THD Inter-RAT CS Used Frequency Trigger Ec/No THD Inter-RAT R99 PS Used Frequency Trigger Ec/No THD Inter-RAT HSPA Used Frequency Trigger Ec/No THD

-11

-15

-15

-12

-12

-102

-98

-110

-110

-105

-105

21

16

16

<NULL>

<NULL>

<NULL>

Inter-RAT CS Used Frequency Trigger RSCP THD

<NULL>

Inter-RAT R99 PS Used Frequency <NULL> Trigger RSCP THD Inter-RAT HSPA Used Frequency Trigger RSCP THD Inter-RAT Measure Timer Length Inter-RAT Ping-Pong Timer Inter-RAT Ping-Pong Hysteresis 3A Event Retry Period 3A Event Maximum Retry Times Inter-RAT HO Physical Channel Failure THD Inter-RAT HO Physical Channel Failure Penalty Timer <NULL> <NULL> 0 0

<NULL>

60

30

Inter-RAT Filter Coefficient = D3 3C Hysteresis = 0 Event 3C Trigger Delay = D640 BSIC Verify Switch = Verify mode Inter-RAT CS Handover Decision THD = 21 Inter-RAT PS Handover Decision THD = 21 Inter-RAT Handover Max Attempt Times = 16 Inter-RAT Measure Timer Length = 60 Send Load Info to GSM Ind = OFF NCOV Reloc Ind Based on GSM Cell Load = ON CS Domain Reloc GSM Load THD = 80 PS Domain Reloc GSM Load THD = 60 Event 3C Retry Period = 4 Event 3C Retry Max Times = 1 Inter-RAT HO Physical Channel Failure THD = 3 Inter-RAT HO Physical Channel Failure Penalty Timer = 30 (Number of results = 1)

Softer Handover Combination Indication Switch = NodeB chooses whether combine at NodeB HSPA Hysteresis Timer Length = 0 Inter-Freq and Inter-RAT Coexist Measure Threshold Choice = Choosing the inter-RAT oriented parameters Max Number of Cell in EDCH Active Set = 3 The Timer Length of Anti Pingpong NCOV Interfreq Handover = 30 (Number of results = 1)

nted parameters

CQI Power Offset = PO_24/15 CQI Power Offset Multi-RLS = PO_24/15 CQI Repetition Factor = 1 CQI Repetition Factor Multi-RLS = 1 CQI Feedback Cycle k = D2 CQI Feedback Cycle k Multi-RLS = D2 Conv Services CQI Feedback Cycle K = D2 MIMO Services CQI Feedback Cycle k = D2 DC MIMO Services CQI Feedback Cycle k = D4 (Number of results = 1)

Inter-frequency Measure Filter Coeff = D3 2C Hysteresis = 6 Event 2C Trigger Delay = D640 Inter-freq measure target frequency trigger Ec/No THD = -16 Inter-freq Measure Timer Length = 60 2C Event Retry Period = 4 Event 2C Retry Max Times = 1 (Number of results = 1)