You are on page 1of 19

DEFERRED SUBMITTAL NOTES

1. CONTRACTOR TO PROVIDE AND OBTAIN APPROVAL FOR A SITE MITIGATION AND CONSTRUCTION MITIGATION PLAN. SUCH PLANS SHALL ADDRESS ALL ACTIVITIES AND SHALL INCLUDE, BUT IS NOT LIMITED TO, VEHICLE PARKING, MATERIAL STORAGE, STREET CLEANING, WORK HOURS, ETC. CONTRACTOR TO MAINTAIN A CLEAN JOB SITE AND MINIMIZE NOISE AND DUST. WORK TO BE CONFINED TO THE HOURS SPECIFIED IN THE CONSTRUCTION MITIGATION PLAN. 2. HEATING SYSTEM SHALL BE GAS-FIRED FORCED AIR. CONTRACTOR IS RESPONSIBLE FOR GAS SYSTEM DESIGN, INCLUDING DUCT SIZING AND LAYOUT. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PROVIDING HEAT LOSS CALCULATIONS AND ENERGY ANALYSIS AND SUBMITTING THEM. 3. CONTRACTOR TO PROVIDE MAKE, MODEL, BTU's, APPROVAL LISTINGS, AND EFFICIENCY OF FURNACE AND ANY ADDITIONAL EQUIPMENT TO BUILDING DEPARTMENT. 4. CONTRACTOR TO PROVIDE APPLIANCE I.C.B.O. NUMBERS TO BUILDING DEPARTMENT AND INSTALLATION GUIDES FOR GAS FIREPLACE INSERTS. 5. THE CONTRACTOR SHALL PROVIDE GAS LINE SPECIFICATIONS, PLANS, AND CALCULATIONS TO BUILDING DEPARTMENT IF THE GAS PIPE LINE SYSTEM IS OVER 4 oz. PRESSURE. CONTRACTOR SHALL ALSO INCLUDE REGULATOR VALVE SPECIFICATIONS AND SHOW PLACEMENT ON PLANS. 6. CONTRACTOR TO PROVIDE THE NUMBER OF BACKFLOW PREVENTORS TO BE INSTALLED IN THIS STRUCTURE. 7. INSPECTIONS ARE REQUIRED FOR ALL STUCCO AND EIFS SYSTEMS. PROVIDE ICBO EVALUATION REPORT (OR EQUAL) FOR ANY SUCH SYSTEM USED. IRC R109.1.5

ROOF LIVE FLOOR DEAD FLOOR LIVE

68 psf 15 psf 40 psf D2 90 mph EXPOSURE C

Troy & Susan Schwinn


1

SEISMIC ZONE WIND

DEFERRED ITEMS
PRE-FABRICATED TRUSS DESIGN GAS PIPELINE SCHEMATIC GAS FIREPLACE INSERT SPECIFICATIONS ___# BACKFLOW PREVENTERS

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

2 3 4 5

DRAWING INDEX Sheet Number


A101 A201 A202 A203 A301 A302 A303 A304 E101 E102 S0 S101 S201 S202 S203 S301 S401 S402

Sheet Name
SITE PLAN MAIN LEVEL PLAN UPPER LEVEL PLAN AREA PLANS ELEVATIONS ELEVATIONS 3D VIEWS BUILDING SECTIONS MAIN LEVEL ELECTRICAL UPPER LEVEL ELECTRICAL STRUCTURAL NOTES FOUNDATION PLAN MAIN FLOOR FRAMING 2nd FLOOR FRAMING ROOF FRAMING SHEAR PLANS DETAILS DETAILS

BUILDER: BUILDERS SIGNATURE:_____________________________________ DATE:__________________________________________

DESIGNER:

ENGINEER OF RECORD:
PARK ENGINEERING, LLC 90 West 200 South, Suite #1 Heber City, Utah 84032 Ph: (435) 654-1456

385 West Airport Rd. - Heber City, Utah 84032 Ph: (435) 657-2120 - Fx: (435) 654-7555

SCHWINN RESIDENCE

385 West Airport Rd. - Heber City, Utah 84032 Ph: (435) 657-2120 - Fx: (435) 654-7555

RESIDENCE FOR:

DESIGN LOADS & CRITERIA


ROOF DEAD 12 psf

Lot 3
DATE

Lot 1

REVISIONS

Troy & Susan Schwinn SITE PLAN

ELEVATION MIN. 2'-0" BELOW TOW

70.00' S 89 58'18" W
ELEVATION MIN. 2'-0" BELOW TOW
DRAWINGS FOR:

46.48' N 00 01'42" W

20' - 0"

Lot 4

Rear Setback

Lot 2 Daniels Gate Sub Plat "B"

62.50' N 00 07'22" W

75 '-

10' - 0" Setback

10' - 0" Setback

DATE: CHECKED BY: DRAWN BY:

3"

58' - 5"

83 '-

TOW: 0'-4"

TOW: 0'-4"

7.13' N 89 59'00" W

80.25' N 00 01'42" W

PROPOSED HOUSE
UP

TOW: 0'-4" 10' - 0" Setback

74.50' S 00 01'42" W

Lot 5

2 6'

TOW: 0'-4"
Front Setb ack 20' - 0"

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

- 3"

ELEVATION MIN. 2'-0" BELOW TOW

77.83' N 82 27'26" W
30' - 0" ELEVATION MIN. 2'-0" BELOW TOW

2060 South
SITE PLAN
SCALE: 1" = 10'-0"

SHEET NUMBER

A101

N. Thomas

SHEET TITLE

T. Munford

April 2009

6"

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

61' 4"

18' - 2" 3' - 3" 11' - 0" 7' - 9" 4' - 9" 4' - 6" 18' - 6" 4' - 6"

2' - 6" 19' - 3" 5' - 0"

18' - 3" 5' - 11" 4' - 1"

7' - 1" 3' - 0"

7' - 0"

4' - 0" x 8' - 0" 3' - 3"

4' - 0" x 8' - 0"

4' - 0" x 8' - 0"

6' - 0" x 5' - 0" SL

4' - 0" x 6' - 0" SL

4' - 4"

2' - 0" x 2' - 0" 2' - 0" x 2' - 0" 2' - 0" x 2' - 0" Fixed Fixed Fixed

6' - 6"

3' - 0" x 6' - 8"

4' - 0"

7' - 0"

Covered Patio

7' - 9"

6' - 6"

6'

8" 3/

20'-1" x 14'-8" 11' - 0"

4' - 0" x 6' - 0" SL 3' - 3"

Great Room
17'-6" x 22'-8"

4' - 0" x 6' - 0" SL

TEMP PUMP ACCESS

5' - 0"

4' - 0"

W/H
FLOOR DRAIN

TEMP

8' - 10"

Mech. Room

BOILER

4' - 0"

21' - 6"

45' - 0"

2' - 10" x 6' - 8"

2' - 6" x 6' - 8"


G4

M. Bath
7 2' " 3 /4

8' - 1"

Closet

4' - 10"

1 4' - 0" x 4' - 0" SL A304

2' - 10"

Kitchen
2' 11 1/4 "

12' - 11"

2' - 0" x 6' - 8"

9' - 8"

G15

G16

G26

BENCH/COATS
6' - 4" 5' - 11" 1' - 5" 3' - 0" x 6' - 8" 4' - 11" 6' - 8"
FLOOR DRAIN

4' - 4"

2' - 0" x 6' - 8" 6' - 8" 3' - 0" 5' - 0"

2x6 BEARING WALLS

Mud/Laundry

Pantry
2' - 4"
ART NICHE

2' - 6" x 6' - 8"

G6

G8

17' - 8"

4' - 11"

(2-STORY)
12' - 0"

12' - 6"

Living Room
10'-6" x 11'-10"

Foyer
12'-4" x 23'-0" 2' - 4" x 6' - 8"

Mechanic
6'-0" x 11'-6"

G25

ATTIC ACCESS

5' - 3"

Bath

21'-0" x 21'-6" 2' - 0" 2' - 0" 6' - 0" x 5' - 0" SL 6' - 0" x 8' - 0"

22' - 0"

2-Car Garage

4' - 0" x 5' - 0" SL

10' - 3"

2' - 0" x 6' - 8"

10' - 0"

Covered Porch

STONE VENEER

2 A304

8' - 0" x 8' - 0"

8' - 0" x 8' - 0"

15' - 4" 7' - 3" 11' - 2" 8' - 11" 5' - 0" 6' - 8"

15' - 0" 6' - 8" 13' - 4" 57' - 0"

4' - 8" 5' - 10" 5' - 6" 10' - 4" 22' - 0" 5' - 10"

STONE VENEER W/CAP

PLUMBING NOTES: 1. ALL TANK TYPE WATER CLOSETS WILL HAVE A FLOW RATE OF 1.6 GALLONS OR LESS PER FLUSH. 2. ALL SHOWER HEADS WILL HAVE A FLOW RATE OF 2.5 GALLONS PER MINUTE OR LESS. 3. ALL HOSE BIBS SHALL HAVE NON-FREEZE TYPE BACK FLOW PREVENTERS, AND BE PROVIDED AT THE FRONT AND REAR OF THE HOME AND AS DIRECTED BY HOME OWNER. 4. ALL PLUMBING VENTS THROUGH ROOF SHALL BE A MINIMUM 3" PIPE. 5. EXPANSION TANK SHOULD BE INSTALLED ON THE CULINARY WATER SYSTEM. 6. AN ACCESS SHOULD BE PROVIDED TO THE PUMP AND MOTOR OF ALL JETTED TUBS. 7. SHOWERS TO BE FINISHED TO A HEIGHT OF 72" ABOVE THE FLOOR. 8. 1" WIDE SEISMIC STRAP TO ANCHOR UPPER 1/3 OF WATER HEATER TO STRUCTURAL MEMBER.

7' - 0"

13' - 10"

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

MAIN LEVEL PLAN


SCALE: 1/4" = 1'-0"

SHEET NUMBER

A201

N. Thomas

REF.

18'-6" x 9'-2"

UP

MECHANICAL NOTES: 1. PROVIDE COMBUSTION AIR FOR ALL FUEL BURNING APPLIANCES AT A MINIMUM RATE OF 1 SQ. INCH PER 3000 BTU/HR INPUT IN THE TOP 12" OF THE ROOM. 2. PROVIDE A SHUT-OFF VALVE AND SEDIMENT TRAP WITHIN 6 FEET OF ALL GAS APPLIANCES. 3. ALL HEAT DUCTS AND IN COLD AREAS SHOULD BE INSULATED. 4. FIREPLACE FLUES NEED TO EXTEND A MINIMUM OF 2 FEET ABOVE ANY ROOF LINE WITHIN 10 FEET, AND NOT LESS THAN 3 FEET ABOVE THE POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. 5. PROVIDE A MINIMUM OF 30" OF WORKING SPACE IN FRONT OF THE FURNACE AND MINIMUM OF 3" ALONG THE SIDES AND BACK. 6. VENT DRYER TO OUTSIDE WITH MAXIMUM LENGTH OF 25', WITH 2.5 FEET FOR 45 DEGREE BENDS AND 5 FEET FOR 90 DEGREE BENDS. 7. ALL BATHROOM FANS TO BE VENTED TO EXTERIOR. 8. HEATING SYSTEM SHOULD BE CAPABLE OF PROVIDING 68 DEGREES FAHRENHEIT IN ALL ROOMS 36" ABOVE FLOOR.

55' - 0"

SHEET TITLE

DRAWN BY:

T. Munford

4' - 0" x 6' - 0" SL

11'-0" x 11'-8"

2' - 0" x 6' - 8"

4' - 0" x 5' - 0" SL

Dining

G29

3' - 0"

8' - 11"

5' - 11"

3' - 10"

3' - 6"

5' - 8"

MAIN LEVEL PLAN

4' - 0" x 5' - 0" SL 2' - 1"

CHECKED BY:

April 2009

3' - 0" x 8' - 0"

3' - 10"

15' - 0"

Master Suite

GENERAL NOTES: 1. ERRORS AND OMISSION WHICH MAY OCCUR IN THE CONTRACT DOCUMENTS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER, IN WRITING AND WRITTEN INSTRUCTION SHALL BE OBTAINED PRIOR TO PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY ERRORS, DISCREPANCIES OR OMISSIONS FOR WHICH THE CONTRACTOR FAILED TO NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION AND OR FABRICATION OF THE WORK. 2. THE TOPS OF HANDRAILS SHALL BE PLACED 36" ABOVE THE NOSING OF TREADS. HANDRAIL ENDS SHALL RETURN TO WALL 1 " DIA HANDGRIPS. MAINTAIN A MINIMUM SPACE OF 1 " BETWEEN THE WALL AND THE HANDRAIL WHERE OPEN HANDRAIL OCCUR THERE SHOULD BE LESS THAN A 4" SPACE BETWEEN RAILING. 3. ALL DECKS AND UNENCLOSED FLOOR OPENINGS WHICH ARE MORE THAN 30" ABOVE GRADE OR FLOOR BELOW SHALL HAVE A GUARDRAIL AT LEAST 36" HIGH. THE SPACES BETWEEN RAILS SHALL BE LESS THAN 4". 4. USE GRACE ICE AND WATER SHIELD, EXTEND 36" BEYOND LINE OF EXTERIOR WALL AT EAVES, 24" EACH SIDE OF VALLEYS. 5. USE CONTINUOUS RIDGE VENT WITH " OPENING EACH SIDE OF RIDGE. 6. ENCLOSED ATTIC AND SPACES BETWEEN RAFTERS SHALL HAVE CLEAR CROSS VENTILATION AREA TO OUTSIDE VENTS. 1/150 OF SPACE VENTILATED FOR GABLE VENTS. 1/300 OF SPACE VENTILATED FOR BOTH GABLE AND EAVE VENTS. 7. USE A MINIMUM OF 4 MIL POLYETHYLENE TO BE INSTALLED OVER INSULATION AT COLDWALL APPLICATIONS AND UN-VENTED CEILINGS. 9. GARAGE TO BE SEPARATED FROM HOUSE BY A 20 MIN FIRE WALL. DOORS FROM GARAGE TO DWELLING TO BE A _ MINIMUM 1 3" THICK SOLID CORE 20 MINUTE FIRE RATED, AND NOT OPEN INTO A SLEEPING ROOM. 8 10. ROOF FELT UNDER 30 YEAR ASPHALT SHINGLES. 11. R-13 WALL INSULATION AND R-38 ATTIC INSULATION. 12. EVERY THIRD SOFFIT PIECE SHOULD BE POROUS TO ALLOW FOR ROOF VENTILATION. 13. PROVIDE AN ATTIC ACCESS TO ALL ATTIC SPACE WITH A MINIMUM DIMENSION OF 22" X 30"AND 30" HEADROOM. 14. ALL SHOWER DOORS AND WINDOWS IN SHOWER AND TUB AREAS SHOULD BE TEMPERED, AND SWING OUTWARD. 15. SMOKE ALARMS ARE REQUIRED TO BE INTERCONNECTED AND WIRED TO PRIMARY POWER SOURCE WITH BATTERY BACKUP. 16. ALL STAIRS SHALL HAVE A MINIMUM WIDTH OF 36" AND A MAXIMUM RISE OF 8 INCHES AND MINIMUM RUN OF 9 INCHES. 18. MAINFLOOR HAS A CEILING HEIGHT TO BE FOUND ON SECTIONS VIEW. 19. ALL WINDOWS TO BE VINYL SLIDER TYPE WINDOWS, WITH LOW E GLASS. 20. ALL GLASS THAT IS PART OF A DOOR ASSEMBLY, WITHIN 24" OF THE ARCH OF A DOOR, LESS THAN 60 INCHES ABOVE A WALKING SURFACE THAT IS WITHIN 5 FEET OF STAIRS, WITHIN 5 FEET OF SPAS OR POOLS, AND ALL FIXED GLASS PANELS SUBJECT TO HUMAN IMPACT SHALL BE TEMPERED. 21. SHINGLES INSTALLED ON A ROOFS WITH A SLOPE OF 4 TO 12 WILL REQUIRE A DOUBLE LAYER OF UNDERLAYMENT. 22. AUTOMATIC GARAGE DOOR OPENERS, TO BE IN ACCORDANCE WITH UL325. 1 _" A FOOT 23. SURFACE OF GARAGE FLOORS TO BE 3.5" MIN CONCRETE OF NON COMBUSTIBLE MATERIAL AND SLOPE 4 TOWARD VEHICLE ENTRY . 24. SLAB ON GRADE FLOORS TO BE AT EXTERIOR PERIMETER FOUNDATION WALLS THAT ARE ABOVE GRADE ARE REQUIRED TO BE INSULATED. 25. LANDINGS SHALL HAVE A MINIMUM DIMENSION MEASURED IN THE DIRECTION OF TRAVEL OF 36". 26. BASEMENTS WITH HABITABLE SPACE AND EACH SLEEPING ROOM SHALL HAVE EGREES OF AT LEAST: AN EXTERIOR DOOR OR WINDOW WITH A FINISHED SILL HEIGHT WITHIN 44" OF THE FLOOR, MINIMUM NET CLEAR OPENABLE AREA OF 5.7SQ. FT., MINIMUM NET CLEAR OPENABLE WIDTH OR 20" AND MINIMUM NET CLEAR OPENABLE HEIGHT OF 24". GRADE FLOOR OPENINGS MAY HAVE A MINIMUM NET CLEAR OPENING OF 5SQ. FT.

DATE

REVISIONS

Troy & Susan Schwinn

DRAWINGS FOR:

11' - 0"

3' - 10"

3' - 4"

DATE:

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

38' - 4" 6' - 7" 3' - 5" 7' - 7" 4' - 5" 8' - 3" 34' - 0" 16' - 2" 11' - 3" 11' - 2" 7' - 10" 4' - 4"

DATE

REVISIONS

Troy & Susan Schwinn UPPER LEVEL PLAN

Deck
9' - 0" x 5' - 0" CS/Fixed/CS 4' - 0" x 5' - 0" SL

11' - 0"

3' - 0" x 6' - 8"

15'-6" x 14'-8" 4' - 0" x 5' - 0" SL

10'-6" x 16'-4"
DATE:

4' - 0"

6' - 7" 2' - 6" x 5' - 0" CS

4' - 4"

7' - 4"
ATTIC ACCESS

13' - 3"

3' - 10"

7' - 4"

2' - 4"

G23

G26

9' - 6"

Loft
12'-11" x 8'-0" 4' - 2"
W/H FLUE BANISTER RAILING W/BALUSTERS

Bedroom 3
13'-3" x 15'-6" 2' - 6" x 5' - 0" CS

FURNACE (ABOVE)

DN

47' - 0"

SHEET TITLE

38" RAILING HEIGHT (TYPICAL)

13' - 8"

A304 5' - 4"

5' - 5" 3' - 0" x 1' - 6" SL 2' - 4" x 6' - 8"

5' - 8"

TEMP

Bath

2' - 4" x 6' - 8"


HALF WALL

3' - 2"

3' - 7"

7' - 2"
3'

3' -

1/4 "

2' - 10" x 6' - 8"

15' - 2"

12' - 2"

Bedroom 2
13'-6" x 11'-6"

14' - 0"

6' - 0" x 6' - 8"

ATTIC ACCESS

OPEN TO BELOW

4' - 0" x 5' - 0" SL


7'-0" x 4'-10" FIXED

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC.

2' - 0"

7' - 3" 14' - 2"

8' - 11" 2' - 0"

6' - 8" 13' - 4" 38' - 4"

6' - 8" 8' - 10"

ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

2 A304

UPPER LEVEL PLAN


SCALE: 1/4" = 1'-0"

SHEET NUMBER

A202

DRAWN BY:

2' - 10" x 6' - 8"

FURNACE/ ATTIC ACCESS

N. Thomas

47' - 0"

CHECKED BY:

16' - 2"

2' - 10" x 6' - 8"

T. Munford

4' - 0"

2' - 6" x 6' - 8"

5' - 0" x 6' - 8"

April 2009

Bedroom 4

17' - 0"

Rec. Room

15' - 4"

6' - 6"

DRAWINGS FOR:

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

10' - 0"

4' - 6"

10' - 0"
" 11

DATE

REVISIONS

Troy & Susan Schwinn AREA PLANS

DRAWINGS FOR:

Area 2052 SF
UP

Area 1131 SF
DN

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555

Main Level Area Plan (Finished SF)


SCALE: 1/8" = 1'-0"

Upper Level Area Plan (Finished SF)


SCALE: 1/8" = 1'-0"

COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

SHEET NUMBER

A203

N. Thomas

SHEET TITLE

DRAWN BY:

T. Munford

CHECKED BY:

April 2009

DATE:

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

Roof 30' - 8 3/4"


SHINGLE SIDING

ARCH. GRADE ASPHALT SHINGLES

12 8

Troy & Susan Schwinn ELEVATIONS

12 8
SHINGLE SIDING

Upper Level Area Plan (Finished SF) 10' - 0" Top Plate (Main) 9' - 0"
DRAWINGS FOR:

VERTICAL BOARD & BATTON OR SIMILAR SIDING

Main Level Area Plan (Finished SF) 0' - 0" TOW -0' - 4" Garage Level (GRADE) -2' - 0" TOF -4' - 2" BOF -5' - 0"

STONE VENEER

SCALE: 1/4" = 1'-0"

CHECKED BY: DRAWN BY:

FRONT ELEVATION

12 8

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

REAR ELEVATION
SCALE: 1/4" = 1'-0"

SHEET TITLE

PROVIDE ATTIC VENTING THROUGH ROOF TO ALLOW MIN. 7 SQ. FT. NET FREE VENTING AREA

SHEET NUMBER

A301

N. Thomas

T. Munford

April 2009

0' - 4"

DATE:

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

Top Plate (Upper) 19' - 0"

DATE

12

REVISIONS

Roof 30' - 8 3/4"

12 8

DATE

REVISIONS

Troy & Susan Schwinn ELEVATIONS

12 8

Top Plate (Upper) 19' - 0"

12 8

Top Plate (Main) 9' - 0"

Top Plate (Lower) -1' - 0" Garage Level (GRADE) -2' - 0" TOF -4' - 2" BOF -5' - 0"

RIGHT SIDE ELEVATION


SCALE: 1/4" = 1'-0"
ARCH. GRADE ASPHALT SHINGLES

12 8
VERTICAL BOARD & BATTON OR SIMILAR SIDING

12 8

12 3

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

STONE VENEER

LEFT SIDE ELEVATION


SCALE: 1/4" = 1'-0"

SHEET NUMBER

A302

N. Thomas

SHEET TITLE

DRAWN BY:

T. Munford

CHECKED BY:

April 2009

Main Level Area Plan (Finished SF) 0' - 0"


DATE:

DRAWINGS FOR:

12

Upper Level Area Plan (Finished SF) 10' - 0"

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

DATE

REVISIONS

Troy & Susan Schwinn 3D VIEWS

DRAWINGS FOR:

3D View - Front
SCALE:

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

SHEET NUMBER

3D - Main Level
SCALE:

3D - Upper Level
SCALE:

A303

N. Thomas

SHEET TITLE

DRAWN BY:

T. Munford

CHECKED BY:

April 2009

DATE:

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

Roof 30' - 8 3/4"


REVISIONS
R-38 R-19 PRE-ENGINEERED TRUSSES

Troy & Susan Schwinn BUILDING SECTIONS

PRE-ENGINEERED TRUSSES

BEDROOM 3
2x4 INT. WALLS R-19 FLOOR JOISTS (PER PLAN)

HALF WALL

LOFT
R-38 BLOCKING

6'-8" HEADROOM CLEARANCE

Upper Level Area Plan (Finished SF) 10' - 0" Top Plate (Main) 9' - 0"
DRAWINGS FOR:

2x6 WALLS (TYP. EXT.)

HANDRAIL TO BE 36" ABOVE TOE OF TREAD

R-19

0' - 7 1/2"

KITCHEN
0' - 10"

2x6 BEARING WALL

M. BATH
2x4 INT. WALLS

Main Level Area Plan (Finished SF) 0' - 0" TOW -0' - 4" Garage Level (GRADE) -2' - 0" TOF -4' - 2"

4" SLAB ON GRADE FLOOR

MIN

36"

FOUNDATION (PER PLAN)

FOOTING (PER PLAN)

FOUNDATION (PER PLAN)

FOOTING (PER PLAN)

FOOTING (PER PLAN)

Section 1
SCALE: 1/4" = 1'-0"

PRE-ENGINEERED TRUSSES

OVERBUILD RAFTERS
SHEET TITLE

PRE-ENGINEERED ATTIC TRUSSES

GIRDER TRUSS

R-38

FURNACE

HANGER (PER PLAN)

2x6 EXT. WALLS (TYPICAL)

LOFT
FLOOR BEAM (OPTIONAL SB-2 SHOWN)

REC. ROOM
FLOOR BEAM (OPTIONAL SB-1 SHOWN)

R-19

RAFTERS (PER PLAN)

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
DECK JOISTS (PER PLAN) DECK BEAM (PER PLAN)
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

HANGER HANGERS BOTH SIDES OF BEAMS

PORCH BEAM

FLOOR JOISTS (PER PLAN)

HANGER

KITCHEN
4" SLAB ON GRADE FLOOR

MIN.

GRADE

MIN.

36"

6"

SHEET NUMBER

Section 2
SCALE: 1/4" = 1'-0"

A304

N. Thomas

DRAWN BY:

T. Munford

BOF -5' - 0"

CHECKED BY:

April 2009

STAIR INFO: - 16 RISERS @ 7 1/2" - 14 TREADS @ 10" - 1 LANDING

DATE:

MIN.

6"

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

Top Plate (Upper) 19' - 0"

DATE

ELECTRICAL NOTES
E1. PLEASE CONTACT ELECTRICIAN & LOG STACKER PRIOR TO CONSTRUCTION OF BUILDING TO ENSURE ACCURACY OF ALL ELECTRICAL WIRING. E2. ELECTRICAL WIRING ON THESE PRINTS ARE USED AS A GUIDE ONLY. CONSULT ELECTRICIAN FOR PROPER PLACEMENT OF ELECTRICAL FIXTURES. E3. ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS, IN GARAGES, BATHS, UNFINISHED BASEMENTS AND OUTSIDE RECEPTACLES SHALL BE GFCI PROTECTED (IRC E3802). E4. EXTERIOR OUTLETS SHALL HAVE WATERPROOF COVERINGS. E5. ALL ELECTRICAL OUTLET BRANCH CIRCUITS IN ALL BEDROOMS TO BE PROVIDED W/ ARC FAULT PROTECTION. E6. PROVIDE SMOKE DETECTORS CONFORMING TO IRC SECTION R313. ALL LEVELS, ALL BEDROOMS, ACCESS TO ALL BEDROOMS, AND IN ALL ROOMS WITH SLOPED CEILINGS NEXT TO HALLS SERVING BEDROOMS. ALL SMOKE DETECTORS SHALL BE WIRED IN SERIES W/ BATTERY BACK UP. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCH THAT ACTUATION OF ONE SHALL ACTUATE ALL SMOKE DETECTORS. (R313.1-2) E7. CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON EACH HABITABLE LEVEL OF A DWELLING UNIT EQUIPPED WITH A FUEL BURNING APPLIANCE AND SHALL BE INTERCONNECTED W/ SMOKE DETECTORS & HARD WIRED W/ BATTERY BACK-UP. (R313.2 AS AMENDED BY STATE). E8. ALL BATHROOM FANS TO BE VENTED TO EXTERIOR AT A RATE OF 50 CUBIC FEET PER MINUTE FOR INTERMITTENT OR 20 CUBIC FEET PER MINUTE FOR CONTINUOUS VENTILATION (IRC R303.3). E9. COPPER GROUND ROD TO BE 1/2" x 8" DRIVEN VERTICALLY INTO GROUND BELOW METER BASE/DISCONNECT LOCATION FOR GROUNDING AND BONDING OF ALL METAL PIPING INCLUDING GAS E10. ALL RECEPTACLES SERVICING UNFINISHED BASEMENTS TO BE GFCI PROTECTED. E11. ELECTRICAL PANELS MUST HAVE 30" WIDE BY 36" DEEP WORKING SPACE & 6'-6" HEADROOM. PROVIDE PROPER FIRE RATING FOR BOXES FACING INTO GARAGES. E12. ALL SPAS AND HOT TUBS SHALL COMPLY WITH THE CURRENT INTERNATIONAL RESIDENTIAL CODE, SPECIFICALLY EQUIPMENT LOCATION AND CLEARANCES SHALL COMPLY WITH E4103. E13. PROVIDE A COMFORT HEATING SYSTEM CAPABLE OF MAINTAINING 68 DEGREES F AT A POINT 36 INCHES ABOVE THE FLOOR IN ALL ROOMS (IRC R303.8). E14. OUTLETS ARE REQUIRED TO BE INSTALLED SO THAT NO POINT ALONG WALLS IS MORE THAN 6 FEET FROM AN OUTLET.

DATE

REVISIONS

Troy & Susan Schwinn MAIN LEVEL ELECTRICAL

AFCI

SD
AFCI

S/C

AFCI

DRAWINGS FOR:

30"

GFCI (PUMP)

PERIMETER CLEARANCE FOR PANEL W/ 6'-6" HEADROOM

30"

- Standard Single Light Switch - Electric Vent & Light Comb.

GFCI GFCI DW

SD
GFCI GFCI

- Smoke Detector - CO Detector

- Ceiling Fan

CO

GFCI

GFCI

220

GFCI

- Fluorescent Light

SHEET TITLE

TO ENSURE ACCURACY OF ELECTRICAL WIRING PLEASE CONTACT ELECTRICIAN & LOG STACKER PRIOR TO CONSTRUCTION OF BUILDING. ELECTRICAL WIRING ON THESE PRINTS SHOULD BE USED AS A GUIDE ONLY. CONSULT ELECTRICIAN FOR PROPER PLACEMENT OF ELECTRICAL FIXTURES.

GFCI GFCI

GFCI

ELECTRICAL SYMBOL LEGEND


LIGHT
GFCI GFCI

WALL LIGHT RECESSED LIGHT


GFCI

BATHROOM VENT
CEILING CEILING

WP/GFCI

CEILING FAN

FLUORECENT LIGHT

110 VOLT OUTLET


U-FER GROUND

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

GFCI

GFCI OUTLET
GFI

AFCI OUTLET
AFI

220 VOLT OUTLET


220

SD S/C

SMOKE DETECTOR SMOKE / CARBON MONOXIDE DETECTOR COMBO SWITCH

Main Level Electrical


SCALE: 1/4" = 1'-0"

3-WAY SWITCH

SHEET NUMBER

E101

N. Thomas

GFCI

DRAWN BY:

T. Munford

GFCI

CHECKED BY:

GFCI

ELEC. PANEL

GFCI
36"

- 110 Volt Outlet


220 GFCI AFI

- Ceiling Light Outlet - Recessed Lighting


TV
P

W/H

- 220 Volt Outlet - GFCI 110 Volt Outlet - AFI 110 Volt Outlet

- T.V. Outlet - Telephone Jack

BOILER FOR RADIANT FLOORING

DATE:

ELECTRICAL SYMBOL SCHEDULE

April 2009

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

AFCI

AFCI

WP/GFCI

AFCI

W P / G FC I
AFCI GFCI
GFCI

220

GFCI
GFCI

GFCI GFCI

ELECTRICAL NOTES
E1. PLEASE CONTACT ELECTRICIAN & LOG STACKER PRIOR TO CONSTRUCTION OF BUILDING TO ENSURE ACCURACY OF ALL ELECTRICAL WIRING. E2. ELECTRICAL WIRING ON THESE PRINTS ARE USED AS A GUIDE ONLY. CONSULT ELECTRICIAN FOR PROPER PLACEMENT OF ELECTRICAL FIXTURES. E3. ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS, IN GARAGES, BATHS, UNFINISHED BASEMENTS AND OUTSIDE RECEPTACLES SHALL BE GFCI PROTECTED (IRC E3802). E4. EXTERIOR OUTLETS SHALL HAVE WATERPROOF COVERINGS. E5. ALL ELECTRICAL OUTLET BRANCH CIRCUITS IN ALL BEDROOMS TO BE PROVIDED W/ ARC FAULT PROTECTION. E6. PROVIDE SMOKE DETECTORS CONFORMING TO IRC SECTION R313. ALL LEVELS, ALL BEDROOMS, ACCESS TO ALL BEDROOMS, AND IN ALL ROOMS WITH SLOPED CEILINGS NEXT TO HALLS SERVING BEDROOMS. ALL SMOKE DETECTORS SHALL BE WIRED IN SERIES W/ BATTERY BACK UP. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCH THAT ACTUATION OF ONE SHALL ACTUATE ALL SMOKE DETECTORS. (R313.1-2) E7. CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON EACH HABITABLE LEVEL OF A DWELLING UNIT EQUIPPED WITH A FUEL BURNING APPLIANCE AND SHALL BE INTERCONNECTED W/ SMOKE DETECTORS & HARD WIRED W/ BATTERY BACK-UP. (R313.2 AS AMENDED BY STATE). E8. ALL BATHROOM FANS TO BE VENTED TO EXTERIOR AT A RATE OF 50 CUBIC FEET PER MINUTE FOR INTERMITTENT OR 20 CUBIC FEET PER MINUTE FOR CONTINUOUS VENTILATION (IRC R303.3). E9. COPPER GROUND ROD TO BE 1/2" x 8" DRIVEN VERTICALLY INTO GROUND BELOW METER BASE/DISCONNECT LOCATION FOR GROUNDING AND BONDING OF ALL METAL PIPING INCLUDING GAS E10. ALL RECEPTACLES SERVICING UNFINISHED BASEMENTS TO BE GFCI PROTECTED. E11. ELECTRICAL PANELS MUST HAVE 30" WIDE BY 36" DEEP WORKING SPACE & 6'-6" HEADROOM. PROVIDE PROPER FIRE RATING FOR BOXES FACING INTO GARAGES. E12. ALL SPAS AND HOT TUBS SHALL COMPLY WITH THE CURRENT INTERNATIONAL RESIDENTIAL CODE, SPECIFICALLY EQUIPMENT LOCATION AND CLEARANCES SHALL COMPLY WITH E4103. E13. PROVIDE A COMFORT HEATING SYSTEM CAPABLE OF MAINTAINING 68 DEGREES F AT A POINT 36 INCHES ABOVE THE FLOOR IN ALL ROOMS (IRC R303.8). E14. OUTLETS ARE REQUIRED TO BE INSTALLED SO THAT NO POINT ALONG WALLS IS MORE THAN 6 FEET FROM AN OUTLET.
REVISIONS DATE

Troy & Susan Schwinn UPPER LEVEL ELECTRICAL

AFCI

220

- 220 Volt Outlet - GFCI 110 Volt Outlet - AFI 110 Volt Outlet - Standard Single Light Switch - Electric Vent & Light Comb.
TV
P

- Recessed Lighting - T.V. Outlet - Telephone Jack

AFCI

GFCI AFI

SD
AFCI

S
S/C

DATE: CHECKED BY: DRAWN BY:

- 110 Volt Outlet

- Ceiling Light Outlet

SD
AFCI

- Smoke Detector - CO Detector

- Ceiling Fan

CO

- Fluorescent Light
AFCI

SD
TO ENSURE ACCURACY OF ELECTRICAL WIRING PLEASE CONTACT ELECTRICIAN & LOG STACKER PRIOR TO CONSTRUCTION OF BUILDING. ELECTRICAL WIRING ON THESE PRINTS SHOULD BE USED AS A GUIDE ONLY. CONSULT ELECTRICIAN FOR PROPER PLACEMENT OF ELECTRICAL FIXTURES.
AFCI

AFCI

AFCI

ELECTRICAL SYMBOL LEGEND


LIGHT

SD WALL LIGHT
AFCI

RECESSED LIGHT BATHROOM VENT

CEILING FAN
AFCI

FLUORECENT LIGHT

110 VOLT OUTLET GFCI OUTLET


GFI

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

AFCI OUTLET
AFI

220 VOLT OUTLET


220

SD S/C

SMOKE DETECTOR SMOKE / CARBON MONOXIDE DETECTOR COMBO SWITCH 3-WAY SWITCH

Upper Level Electrical


SCALE: 1/4" = 1'-0"

SHEET NUMBER

E102

N. Thomas

SHEET TITLE

T. Munford

April 2009

ELECTRICAL SYMBOL SCHEDULE


AFCI

DRAWINGS FOR:

AFCI

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

WP/GFCI

AFCI AFCI

WP/GFCI

AFCI AFCI

A FC I

AFCI

Date

ROOF FRAMING NOTES GENERAL STRUCTURAL NOTES:


DESIGN CODE: 2006 INTERNATIONAL BUILDING CODE DESIGN LOADS: LIVE LOADS USED IN DESIGN: 1. ROOF A) GROUND SNOW LOAD, Pg B) SNOW EXPOSURE COEFFICIENT, Ce C) FLAT ROOF SNOW LOAD, Pf D) DEAD LOAD D) IMPORTANCE FACTOR, I 2. FLOOR LIVE DEAD 6. WIND PRESSURE A) BASIC WIND SPEED B) BUILDING CATEGORY C) IMPORTANCE FACTOR, Iw D) EXPOSURE CLASSIFICATION 7. SEISMIC LOADS A) SEISMIC DESIGN CATEGORY B) SITE CLASS C) IMPORTANCE FACTOR, Ie 2. 96 psf 1.0 67.5 psf 1.0 40 psf 15 psf 90 MPH II 1.0 C C D 1.0

STRUCTURAL MATERIALS:
1. CONCRETE SLABS 3000 psi @ 28 DAYS ELSEWHERE 3000 psi @ 28 DAYS REINFORCING STEEL #4-#10 BARS: ASTM A615, GRADE 60 #3 BARS: ASTM A185, GRADE 40 MESH: ASTM A185 WELDED BARS AND ANCHORS ASTM A706, GRADE 60 WELDED WIRE AND FABRIC TUBES STEEL SHAPES ASTM A185 1. 2. 3. 4. 5. 6. 7. 6. W SHAPES: ASTM A992, Fy=50 KSI OTHER SHAPES: ASTM A36, Fy=36 KSI PLATES: ASTM A36, Fy=36 KSI E70XX ELECTRODES 8. 9. 7. 8. 9. WELDED CONNECTIONS BOLTS ASTM A325N ANCHOR BOLTS ASTM A307 or ASTM A36

NAILING SCHEDULE (U.N.O.):


ALL NAILS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE. JOIST TO SILL PLATE OR GIRDER (TOENAIL) BRIDGING TO JOIST (TOENAIL EA. END) (3) 8d (2) 8d

1.

ALL TRUSSES TO BE SECURED ON EACH END w/ SIMPSON H-1 CLIPS AND GIRDER TRUSSES w/ LGT HOLDOWNS AT EACH END (U.N.O.). BEARING

BOTTOM PLATE TO JOIST OR BLOCKING (FACE NAIL)(3) 16d @ 16" O.C. TOP PLATE TO STUD (END NAIL) STUD TO BOTTOM PLATE DOUBLE STUDS (FACENAIL) DOUBLE TOP PLATES (FACE NAIL) (2) 16d 4. 5.

3. 4. 5.

PROVIDE SOLID BLOCKING UNDER ALL GIRDER TRUSSES AND BEAMS TO FOUNDATION. TRUSS BLOCKING SHALL BE NAILED SOLID TO SHEATHING WITH NAILING THROUGH SHEATHING INTO BLOCKING. LESS

(4) 8d TOENAIL or (2) 16d ENDNAIL 16d @ 24" O.C. 16d @ 16" O.C.

ASTM A500, Fy=46 KSI

6. VALLEY AND HIP RAFTERS ARE NOT TO BE LESS THAN 2" THICK AND NOT IN DEPTH THAN THE CUT END OF THE RAFTER.

PARK ENGINEERING, LLC

TOP PLATES, LAPS & INTERSECTIONS (FACE NAIL) (2) 16d @ 12" O.C.

10. CONTINUOUS HEADER (2 PIECES) 16d @ 16" O.C. ALONG EACH EDGE 11. ROOF JOIST TO PLATE (TOENAIL) 12. CONTINUOUS HEADER TO STUD (TOENAIL) ANCHORS USED. (3) 8d (4) 8d

SHEATHING NOTES:
FLOOR SHEATHING: 3/4" (48/24) APA RATED T&G SUBFLOOR 10d COMMON @ 6" O.C. AT PANEL EDGES, 10d COMMON @ 10" O.C. FIELD. ATTACH PANEL TO FRAMEWORK w/ A CONTINUOUS BEAD OF CONSTRUCTION ADHESIVE OR AS REQ'D BY FINISH FLOOR MATERIAL. ROOF SHEATHING: 5/8" (40/20) APA RATED SHEATHING 8d COMMON @ 6" O.C. AT PANEL EDGES, 8d COMMON @ 12" O.C. FIELD. EXTERIOR WALL SHEATHING: 7/16" STRUCTURAL "I" RATED PANELS 8d COMMON @ 4" O.C. AT PANEL EDGES, 8d COMMON @ 12" O.C. FIELD. BLOCK ALL SHEATHING EDGES w/ 2" NOMINAL BLOCKING. (TYPICAL UNLESS NOTED OTHERWISE ON SHEAR WALL SCHEDULE) INTERIOR WALL SHEATHING: 1/2" GYPSUM WALL BOARD #6 x 11/4" SCREWS @ 4" O.C. AT PANEL EDGES & 8" O.C. FIELD. (U.N.O.)

10. EXPANSION BOLTS RED-HEAD ANCHORS, WEDGE-ALL ANCHORS, OR NATIONAL FASTENERS. PROVIDE ICBO REPORT FOR EXPANSION

13. ROOF JOISTS, LAPS OVER PARTITIONS (FACE NAIL) (3) 16d 14. ROOF JOISTS TO PARALLEL RAFTERS (FACE NAIL) (3) 16d 15. BUILT-UP CORNER STUDS & COLUMNS 16d @ 24" O.C.

11. DIMENSIONAL FRAMING LUMBER DOUGLAS FIR-LARCH #2 OR BETTER (M.C. NOT TO EXCEED 19%) Fb = 900 psi Fcr = 625 psi Fv = 180 psi Fcq = 1,350 psi E = 1,600,000 psi 12. POSTS (2005 NDS) DOUGLAS FIR-LARCH #1 OR BETTER (POSTS AND TIMBERS) Fb = 1,200 psi (M.C. NOT TO EXCEED 19%) Fcq = 1,000 psi 13. TIMBER MEMBERS (2005 NDS) DOUGLAS FIR-LARCH #2 OR BETTER (BEAMS AND STRINGERS) Fb = 875 psi Fcr = 625 psi (M.C. NOT TO EXCEED 19%) Fv = 170 psi Fcq = 600 psi E = 1,300,000 psi DOUGLAS FIR-LARCH #1 OR BETTER Fb = 1,350 psi Fcr = 625 psi Fv = 170 psi Fcq = 925 psi E = 1,600,000 psi 14. LVL MEMBERS (I-LEVEL TRUS JOIST OR EQUIVALENT) Fb = 2600 psi Fv = 285 psi E = 1,800,000 psi Fcr = 750 psi Fcq = 2,510 psi

16. BUILT-UP BEAMS (FACE NAIL AT TOP & BOTTOM 20d @ 32" O.C. STAGGERED ON OPPOSITE SIDES) 17. RIM JOIST TO TOP PLATE (TOENAIL) 16d @ 6" O.C.

FLOOR FRAMING NOTES:


1. 2. 3. 4. PROVIDE BLOCKING BETWEEN JOISTS OVER BEARING WALLS AND OVER FOUNDATION AT BAY WINDOWS AND FLOOR CANTILEVERS. FLOOR SHEATHING TO BE INSTALLED PERPENDICULAR TO FLOOR JOISTS. USE SIMPSON ITT2 OR IUS HANGERS AT JOIST TO BEAM CONNECTIONS. USE SIMPSON HHUS HANGERS OR APPROVED EQUAL AT BEAM TO BEAM CONNECTIONS (U.N.O.).

CONCRETE NOTES
1. 2. 3. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE AND LOCAL CODES. REINFORCED CONCRETE DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 318-08. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. ALL SLABS ON GRADE ARE TO BE PLACED ON COMPACTED BACKFILL. ALL REINFORCING STEEL SHALL BE NEW GRADE 60 DEFORMED BARS AND SHALL BE TIED IN PLACE PRIOR TO POURING CONCRETE. REINFORCING STEEL CONCRETE COVER: SURFACE CAST AGAINST EARTH: 3"

15. GLU-LAM BEAMS (2005 NDS) 24F-V4 DF/DF Fb = 2,400 psi Fcr = 650 psi Fv = 265 psi Fcq = 1,650 psi E = 1,800,000 psi 16. JOISTS I-LEVEL TRUS JOIST, LOUISIANA PACIFIC, OR EQUIV. (INSTALL PER MFR's SPEC's)

4. 5. 6.

17. LOG MEMBERS DOUGLAS FIR-LARCH #1 OR BETTER (T.P.I. GRADED AND STAMPED) Fb = 1200 psi Fcr = 625 psi (M.C. NOT TO EXCEED 19%) Fv = 180 psi Fcq = 1,550 psi E = 1,800,000 psi 18. ERRORS AND OMISSION WHICH MAY OCCUR IN THE CONTRACT DOCUMENTS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER, IN WRITING AND WRITTEN INSTRUCTION SHALL BE OBTAINED PRIOR TO PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY ERRORS, DISCREPANCIES OR OMISSIONS FOR WHICH THE CONTRACTOR FAILED TO NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION AND OR FABRICATION OF THE WORK.

FORMED SURFACES IN CONTACT WITH EARTH OR EXPOSED TO WEATHER: #5 OR SMALLER: 2" #6 OR LARGER: 11/2" FORMED SURFACES NOT IN CONTACT WITH EARTH OR EXPOSED TO WEATHER WALLS, SLABS, JOISTS: 3/4" 7. 8. 9. TOP OF FOUNDATION WALLS TO BE A MINIMUM OF 6" ABOVE FINISHED GRADE. BLOCK OUT OPENINGS FOR GARAGE DOORS AS REQUIRED. ALL CONCRETE EXPOSED TO FREEZING AND THAWING SHALL CONTAIN 5-7% ENTRAINED AIR.

10. ALUMINUM CONDUIT OR PIPING MAY NOT BE EMBEDDED IN ANY CONCRETE. 11. CALCIUM CHLORIDE IS NOT ALLOWED AS AN ADDITIVE TO CONCRETE MIX.

SHEET:

S0
PROJECT ID: SCALE:

Project Number 1/4" = 1'-0"

\\Master_drive\volume_1\Drawings\Drawings2009\Schwinn\Schwinn 2012.3.5 DECK REV.rvt

1/4/2013 6:17:36 PM

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

STRUCTURAL NOTES

Troy & Susan Schwinn

Drawings for:

90 WEST 200 SOUTH, SUITE #1 HEBER CITY, UTAH 84032 Ph. (435) 654-1456 Fx. (800) 375-2156

DESIGNER:

3.

USE SIMPSON ITT TOP FLANGE HANGERS AT ALL RAFTER TO BEAM CONNECTIONS (U.N.O.).

No.

GEJ

2. PROVIDE SOLID BLOCKING BETWEEN TRUSSES AND RAFTERS OVER WALLS.

Description

ENGINEER:

SJP

57' - 0"

HOLD DOWN SCHEDULE


TOW -0' - 10" TOW -4' - 2" F3 LOC AA BB CC DD EE DESCRIPTION MST 36 MST 48 STHD 14 PHD6 HDQ8-SDS3 NOTES INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO 6x6 DF#2 w/ SSTB28 ANCHOR

Description

10' - 0"

FFE -0' - 6" TOW -0' - 10"

F3

10' - 0"

F3

UNEXCAVATED
SLAB ON GRADE

TOW -4' - 2"

F1

11' - 0"

6' - 6"

4' - 6"

F2

TOW -0' - 10"

F2

F2

F2

Loc Wall 1 Wall 2 Wall 3 Wall 4 Wall 5 Wall 6 Wall 7 Wall 8 Wall 9 Wall 10 Wall 11 Wall 12 Wall 13 Wall 14 Wall 15 Wall 16 Wall 17 Wall 18

Description UPPER - REAR UPPER - RIGHT SIDE UPPER - STAIRWELL FRONT ENTRY RIGHT SIDE UPPER - FRONT UPPER - LEFT SIDE MAIN - REAR MAIN - INTERIOR @ MASTER MAIN - INTERIOR MAIN - INTERIOR GARAGE MAIN - RIGHT SIDE MAIN - GARAGE FRONT GARAGE LEFT SIDE MAIN - FRONT WALL MAIN - FRONT WALL LEFT MAIN - LEFT SIDE UPPER - INTERIOR WALL MAIN - INTERIOR

Shear Wall Floor Tie SW-3 none SW-1 MST 37 SW-2 none SW-2 none SW-2 MST 37 SW-1 none SW-2 none SW-2 none SW-2 none SW-2 none SW-1 none SW-2 none SW-3 none SW-2 none SW-2 none SW-3 none SW-2 MST 48 SW-2 none

Hold Down none none HDQ8 HDQ8 none none none PHD6 PHD6 STHD14 none STHD14 STHD14 STHD14 STHD14 STHD14 none PHD6

Anchor Bolts AB-1 AB-1 AB-3 AB-3 AB-1 AB-1 AB-1 AB-2 AB-3 AB-1 AB-1 AB-2 AB-4 AB-2 AB-1 AB-2 AB-3 AB-2

PARK ENGINEERING, LLC

SHEAR WALL LOCATION SCHEDULE


6' - 4 31/32" 25' - 0"

4' - 7 1/32"

F5 TOW -0' - 4"

4' - 1"

CRAWLSPACE

F7

ANCHOR BOLT SCHEDULE


FFE 0' - 0"

LOC
4' - 0"
F2 8' - 11" 18' - 3" 10' - 0"

ANCHOR BOLT
5/8"DIA x 12" ANCHOR BOLT 5/8"DIA x 12" ANCHOR BOLT 5/8"DIA x 12" ANCHOR BOLT 5/8"DIA x 12" ANCHOR BOLT 5/8"DIA x 12" ANCHOR BOLT 5/8"DIA x 12" ANCHOR BOLT

SPACING
32" O.C. 24" O.C. 16" O.C. 12" O.C. 24" O.C. 12" O.C.

SILL PLATE
2x6 2x6 2x6 2x6 3x6 3x6

18' - 6"

AB-1 AB-2 AB-3

62' - 0"

21' - 9"

20' - 10"

F5

4' - 0"

F3 F2

AB-4
65' - 0"

AB-5 AB-6

18' - 0"

1 A304

NOTES:
1. 2. 3. Minimum Anchor Bolt spacing should be AB-1 unless otherwise specified All Anchor bolts should be embedded a minimum of 7" and should be placed between two rebar. All washers should be a plate washer Simpson BP 5/8-3.

F3 F7

34' - 0"

9' - 8" F6 F7 F6 13' - 6" F3 15' - 10"

9' - 0"

11' - 10"

F2

CRAWLSPACE
9' - 6"
FFE 0' - 0"

12' - 3"

11' - 8"

F2

40' - 0"

F2

F2 F2

FFE -2' - 0"

F2 TOW -0' - 4"

F6

UNEXCAVATED
SLAB ON GRADE

F6

SLAB ON GRADE

F2 F3 RECESS DOOR OPENINGS TOW -2' - 0" TOW -0' - 4" F2

TOW -0' - 10"

2 A304 16' - 2" 35' - 0" 57' - 0" 13' - 4" 5' - 6" 1' - 8" 8' - 4" 2' - 0" 22' - 0" 8' - 4" 1' - 8"

10' - 4"

F3

UNEXCAVATED

FFE -0' - 6"

SHEET:

S101
FOOTING / FOUNDATION PLAN
SCALE: 1/4" = 1'-0"

PROJECT ID: SCALE:

Project Number 1/4" = 1'-0"

\\Master_drive\volume_1\Drawings\Drawings2009\Schwinn\Schwinn 2012.3.5 DECK REV.rvt

1/4/2013 6:17:37 PM

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

7' - 0"

FOUNDATION PLAN

Troy & Susan Schwinn

SLOPE FLOOR TOWARD DOOR OPENINGS

2' - 0"

Drawings for:

22' - 0"

90 WEST 200 SOUTH, SUITE #1 HEBER CITY, UTAH 84032 Ph. (435) 654-1456 Fx. (800) 375-2156

10' - 7"

15' - 0"

DESIGNER:

No.

Designer

ENGINEER:

Checker

34' - 0"

16' - 0"

7' - 0"

Date

DATE

REVISIONS

Troy & Susan Schwinn MAIN FLOOR FRAMING

FLOO R JOISTS

DRAWINGS FOR:

DATE: CHECKED BY: DRAWN BY:

BEARING WALLS

1 A304

385 WEST AIRPORT RD. HEBER CITY, UT 84032 Ph. (435) 657-2120 Fx. (435) 654-7555
COPYRIGHT 2008. ALL RIGHTS RESERVED BY KYUNE DESIGNS. NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN PERMISSION. KYUNE DESIGNS IS A D IVISION OF LOG CRAFT, INC. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC., SHALL BE CONSIDERED AS PART OF SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PREFERENCE OVER ANYTHING SHOWN, DESCRIBED, OR IMPLIED WHERE SAME ARE AT VARIANCE.

2 A304

MAIN FLOOR FRAMING


SCALE: 1/4" = 1'-0"

SHEET TITLE

SHEET NUMBER

S201

Author

Checker

07/07/09

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

BEAM SCHEDULE
Loc B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 Beam Name 9' Upper Level Header 4' Upper Level Headers PORCH BEAMS PORCH BEAM WINDOW HEADERS 6' WINDOW HEADERS GIRDER BEAM FLOOR GIRDER BEAM FLOOR GIRDER BEAM FRONT PORCH BEAM GARAGE DOOR HEADERS FLOOR BEAM Beam Type (2) 1.75 x 11.25 LVL (2) 2 x 10 DF-L #2 (1) 3.125 x 9 GLB (1) 3.125 x 10.5 GLB (2) 1.75 x 9.5 LVL (3) 2 x 10 DF-L #2 (3) 1.75 x 14 LVL (1) 5.125 x 19.5 GLB (1) 5.125 x 15 GLB (1) 3.125 x 12 GLB (3) 2 x 10 DF-L #2 (2) 2 x 10 DF-L #2 Trimmer Remarks 2 1 1 2 2 1 2 Option: (1) 5.125 x 15 GLB 3 2 2 1 1

Date

C-1

C-1

C-1

C-1

B-3

B-3

B-3

Description

HANG JOISTS w/ LUS28

C-4 C-1

C-3 C-3

B-4

LOAD ABV

HIP TRUSSES

FLOOR JOIST SCHEDULE


GIRDER TRUSS 2x10 LEDGER ATTACHED TO HOUSE w/ (3) SIMPSON SDS SCREWS @ 16" O.C. Loc FJ-1 FJ-2 Joist Name UPPER FLOOR JOISTS DECK JOISTS Joist (1) 11.875in 110 TJI Joist(s) @ 19.2in O.C. (1) 2in x 10in DF#2 Joists(s) @ 16in O.C.

B-7

DBL JOIST

HANG w/ HHUS26-2

C-3

ROOF RAFTER SCHEDULE


Loc RR-1 Rafter Name PORCH ROOF RAFTERS Rafter (1) 2in x 8in DF#2 Joists(s) @ 24in O.C.

B-8 (SB-1)
C-3

C-2

19 .2" O.C .

C-3

HDR

STEEL BEAM SCHEDULE


Loc SB-1 SB-2 Beam Name B-8 STEEL OPTION B-9 STEEL OPTION Beam Type W10x39 W10x19 Remarks

TJ I1 10 's @

BRG WALL

HDR

C-3

FJ 1: 11 -7/8 "

C-2

C-1

B-9 (SB-2)
LSL RIM BOARD 1 A304

B-12
UP

BRG WALL

BEARING WALL C-4

PRE-ENGINEERED TRUSSES @ 24" O.C.

C-4 BRG WALL

OVERBUILD @ 24" O.C. GIRDER TRUSS

HANG w/ HUS26 w/ (14) 16d NAILS

B-6 B-6
2x10 LEDGER ATTACHED TO HOUSE w/ (3) SDS SCREWS @ 24" O.C. C-4

C-4

PRE-ENGINEERED TRUSSES @ 24" O.C.

C-1

B-10

C-1

B-10

C-1

B-10
C-1

B-11
JACK TRUSSES @ 24" O.C. -ORRR1: 2x8 DF#2 @ 24" O.C. 2 A304

B-11

SHEET:

2nd FLOOR FRAMING


SCALE: 1/4" = 1'-0"

S202
PROJECT ID: SCALE:

Project Number 1/4" = 1'-0"

\\Master_drive\volume_1\Drawings\Drawings2009\Schwinn\Schwinn 2012.3.5 DECK REV.rvt

1/4/2013 6:17:39 PM

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

2nd FLOOR FRAMING

Troy & Susan Schwinn

Drawings for:

90 WEST 200 SOUTH, SUITE #1 HEBER CITY, UTAH 84032 Ph. (435) 654-1456 Fx. (800) 375-2156

C-3

B-5

B-5

B-5

PARK ENGINEERING, LLC

C-3

B-6

Loc C-1 C-2 C-3 C-4 C-5 C-6 C-7

Column Name (2) 2in x 4in DF-L #2 (3) 2in x 4in DF-L #2 (2) 2in x 6in DF-L #2 (3) 2in x 6in DF-L #2 (1) 4in x 4in DF-L #2 (1) 4in x 6in DF-L #2 (1) 6in x 6in DF-L #2

Column Type (2) 2in x 4in DF-L #2 (3) 2in x 4in DF-L #2 (2) 2in x 6in DF-L #2 (3) 2in x 6in DF-L #2 (1) 4in x 4in DF-L #2 (1) 4in x 6in DF-L #2 (1) 6in x 6in DF-L #2

Remarks Built-up Column Built-up Column Built-up Column Built-up Column

DESIGNER:

COLUMN SCHEDULE
No.

Designer

ENGINEER:

Checker

PRE-ENGINEERED TRUSSES @ 24" O.C.

Description

C-3

B-1

C-3

B-2

PARK ENGINEERING, LLC

Loc C-1 C-2 C-3 C-4 C-5 C-6 C-7

Column Name (2) 2in x 4in DF-L #2 (3) 2in x 4in DF-L #2 (2) 2in x 6in DF-L #2 (3) 2in x 6in DF-L #2 (1) 4in x 4in DF-L #2 (1) 4in x 6in DF-L #2 (1) 6in x 6in DF-L #2

Column Type (2) 2in x 4in DF-L #2 (3) 2in x 4in DF-L #2 (2) 2in x 6in DF-L #2 (3) 2in x 6in DF-L #2 (1) 4in x 4in DF-L #2 (1) 4in x 6in DF-L #2 (1) 6in x 6in DF-L #2

Remarks Built-up Column Built-up Column Built-up Column Built-up Column

B-2

FLOOR JOIST SCHEDULE


Loc FJ-1 FJ-2 Joist Name UPPER FLOOR JOISTS DECK JOISTS Joist (1) 11.875in 110 TJI Joist(s) @ 19.2in O.C. (1) 2in x 10in DF#2 Joists(s) @ 16in O.C.

RIDGE

ROOF RAFTER SCHEDULE


Loc RR-1 Rafter Name PORCH ROOF RAFTERS Rafter (1) 2in x 8in DF#2 Joists(s) @ 24in O.C.

OVERBUILD @ 24" O.C.

RIDGE

STEEL BEAM SCHEDULE


Loc SB-1 SB-2 Beam Name B-8 STEEL OPTION B-9 STEEL OPTION Beam Type W10x39 W10x19 Remarks

A304

A LL EY

GIRDER TRUSS

C-4

C-4

PRE-ENGINEERED TRUSSES @ 24" O.C.

RIDGE

HANG w/ HUS26 w/ (14) 16d NAILS

ROOF FRAMING PLAN


SCALE: 1/4" = 1'-0"

2 A304

SHEET:

S203
PROJECT ID: SCALE:

Project Number 1/4" = 1'-0"

\\Master_drive\volume_1\Drawings\Drawings2009\Schwinn\Schwinn 2012.3.5 DECK REV.rvt

1/4/2013 6:17:40 PM

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

ROOF FRAMING

Troy & Susan Schwinn

Drawings for:

90 WEST 200 SOUTH, SUITE #1 HEBER CITY, UTAH 84032 Ph. (435) 654-1456 Fx. (800) 375-2156

DESIGNER:

COLUMN SCHEDULE
No.

Designer

Loc B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12

Beam Name 9' Upper Level Header 4' Upper Level Headers PORCH BEAMS PORCH BEAM WINDOW HEADERS 6' WINDOW HEADERS GIRDER BEAM FLOOR GIRDER BEAM FLOOR GIRDER BEAM FRONT PORCH BEAM GARAGE DOOR HEADERS FLOOR BEAM

Beam Type (2) 1.75 x 11.25 LVL (2) 2 x 10 DF-L #2 (1) 3.125 x 9 GLB (1) 3.125 x 10.5 GLB (2) 1.75 x 9.5 LVL (3) 2 x 10 DF-L #2 (3) 1.75 x 14 LVL (1) 5.125 x 19.5 GLB (1) 5.125 x 15 GLB (1) 3.125 x 12 GLB (3) 2 x 10 DF-L #2 (2) 2 x 10 DF-L #2

Trimmer Remarks 2 1 1 2 2 1 2 Option: (1) 5.125 x 15 GLB 3 2 2 1 1

Date

BEAM SCHEDULE

ENGINEER:

Checker

EY LL A V

Date

WALL 7 SW-2

SW-3

Description

WALL 1

CC AA

PARK ENGINEERING, LLC

WALL 8 SW-2

WALL 2

DD DD

DD

CC

WALL 9

CC

SW-2

DN

1 A304 UP 1 A304 DD SW-2 CC

WALL 6

WALL 18 EE EE CC

WALL 16

SW-3

SW-1

DD

DD EE WALL 3 SW-2 WALL 10 SW-2

CC WALL 17 SW-2 WALL 3 SW-2

WALL 11

WALL 4

SW-2

SW-1

WALL 4

SW-2 WALL 14

CC

EE CC CC CC AA SW-2 WALL 15 AA WALL 5

SW-2

SW-1

AA

Troy & Susan Schwinn

SCALE: 1/4" = 1'-0"

2 A304

CC WALL 12 SW-2

CC

CC

HOLD DOWN SCHEDULE


LOC AA BB CC DD EE DESCRIPTION MST 36 MST 48 STHD 14 PHD6 HDQ8-SDS3 NOTES INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO (2) STUDS MIN. INTO 6x6 DF#2 w/ SSTB28 ANCHOR

2 A304

SHEAR WALL TYPE SCHEDULE


LOC
SW-1 SW-2

SHEATHING
7/16" OSB 7/16" OSB 7/16" OSB 7/16" OSB 7/16" OSB 7/16" OSB 19/32" OSB

BOTH SIDES
NO NO NO NO NO YES NO

EDGE STUD
2x4 2x4 2x4 2x FLAT OR 4x 2x FLAT OR 4x 2x FLAT OR 4x 2x FLAT OR 4x

NAILING
SIZE
8d 8d 8d 8d 8d 8d 10d

EDGE
6" 4" 3" 3" 2" 4" 4"

FIELD
12" 12" 12" 12" 12" 12" 12"

SHEAR PLAN - MAIN LEVEL


SCALE: 1/4" = 1'-0"

SHEAR WALL LOCATION SCHEDULE


Loc Wall 1 Wall 2 Wall 3 Wall 4 Wall 5 Wall 6 Wall 7 Wall 8 Wall 9 Wall 10 Wall 11 Wall 12 Wall 13 Wall 14 Wall 15 Wall 16 Wall 17 Wall 18 Description UPPER - REAR UPPER - RIGHT SIDE UPPER - STAIRWELL FRONT ENTRY RIGHT SIDE UPPER - FRONT UPPER - LEFT SIDE MAIN - REAR MAIN - INTERIOR @ MASTER MAIN - INTERIOR MAIN - INTERIOR GARAGE MAIN - RIGHT SIDE MAIN - GARAGE FRONT GARAGE LEFT SIDE MAIN - FRONT WALL MAIN - FRONT WALL LEFT MAIN - LEFT SIDE UPPER - INTERIOR WALL MAIN - INTERIOR Shear Wall Floor Tie SW-3 none SW-1 MST 37 SW-2 none SW-2 none SW-2 MST 37 SW-1 none SW-2 none SW-2 none SW-2 none SW-2 none SW-1 none SW-2 none SW-3 none SW-2 none SW-2 none SW-3 none SW-2 MST 48 SW-2 none Hold Down none none HDQ8 HDQ8 none none none PHD6 PHD6 STHD14 none STHD14 STHD14 STHD14 STHD14 STHD14 none PHD6 Anchor Bolts AB-1 AB-1 AB-3 AB-3 AB-1 AB-1 AB-1 AB-2 AB-3 AB-1 AB-1 AB-2 AB-4 AB-2 AB-1 AB-2 AB-3 AB-2

SW-3 SW-4 SW-5 SW-6 -or-

NOTES:
1. 2. 3. 4. less 5. All studs for shear walls shall be 16" o.c. unless otherwise noted. All sheathing should be completely blocked. 16d common nail transfer through sill, or toe nail through joist or blocking. ALL Framing members recieving edge nailing from abbutted panels shall not be than Edge Stud Specified for the specified Shear Wall. All Exterior Walls are SW-2 unless otherwise noted.

Drawings for:

SHEAR PLAN - UPPER LEVEL

SHEET:

S301
PROJECT ID: SCALE:

\\Master_drive\volume_1\Drawings\Drawings2009\Schwinn\Schwinn 2012.3.5 DECK REV.rvt

1/4/2013 6:17:41 PM

SHEAR PLANS

SW-2

Project Number 1/4" = 1'-0"

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

WALL 13

SW-3

90 WEST 200 SOUTH, SUITE #1 HEBER CITY, UTAH 84032 Ph. (435) 654-1456 Fx. (800) 375-2156

DESIGNER:

No.

Designer

ENGINEER:

Checker

SECTION A-A
(2) 2x6 STUDS NAILING PER SIMPSON SPEC.

Date

SIMPSON STRAP (REFER TO HOLDOWN SCHEDULE)

10d @ 6" O.C.


PRE-ENGINEERED ROOF TRUSSES ROOF SHEATHING NAIL THROUGH SHEATHING INTO BLOCKING TO PROVIDE SHEAR TRANSFER FULL HEIGHT BLOCKING

10d NAIL @ 3" O.C. ALL AROUND 16d ALL AROUND 2x BLOCKING TO PFT. 1/2" PL Y WOOD P ANE L 2x4 BLKG ALL AROUND 16d @ 16" O.C. PFT @ 24" O.C.

Description

SIMPSON STRAP CENTERED OVER FLOOR LINE

FLOOR JOISTS BEYOND

(2) 2x6 STUDS

A
SIMPSON H-1 CLIP EA. TRUSS SIMPSON A35 WALL SHEATHING 2x STUD WALL
3 1_" 4 3 1_" 4

10d @ 6" O.C. WALL SHEATHING -SEE SHEAR WALL SCHED.

2x EMBEDMENT LENGTH +12" MIN. REBAR LENGTH

DOUBLE TOP PLATE

2_"

1 2

2
S401

STRONG-TIE MST48

3
S401

TRUSS TO WALL DETAIL

4
S401

SHEAR TRANSFER AT TRUSSES (PERPENDICULAR)

EDGE NAILING PER PLAN EDGE NAILING PER PLAN PRE-ENGINEERED TRUSS DESIGNED TO TRANSFER LOAD BY MANUF.

SHEAR WALL PANEL


PRE-ENGINEERED TRUSS DESIGNED TO TRANSFER LOAD BY MANUF.

16d NAILS, STAGGERED NAILING TO BOTTOM PLATE FLOOR SHEATHING 2x SOLID BLOCKING

Simpson Strong-Tie STHD Edge Installation


2x8 BLOCKING @ 24" O.C. (3) SIMPSON 1 1 SDS _"x4 _ " EA. BLOCK
4 2

A35 EA. SIDE OF BLOCK

A35 CLIP @ 16" O.C. 2x4 SHEARWALL PER PLAN 2x6 SHEARWALL PER PLAN

FLOOR JOIST SIMPSON A35 @ 16" O.C. SHEAR WALL PANEL

1
S401

STRONG-TIE STHD14

5
S401

SHEAR TRANSFER AT TRUSSES (PARALLEL)

6
S401

SHEAR TRANSFER AT TRUSS (PARALLEL)

7
S401

SHEAR TRANSFER - INTERIOR (PERP)

HEADER AS PER PLAN NAIL KING STUD TO GARAGE HEADER w/ (6) 16d NAILS STAGGERED

4'-0" MIN STUD WALL STUD WALL FLOOR SHEATHING (8) 16d NAILS FLOOR SHEATHING RIM BOARD NAIL SHEATHING TO RIM BOARD PER SHEARWALL PLAN EDGE NAILING. (TREAT RIM BOARD AS EDGE) NAIL SHEATHING TO RIM BOARD PER SHEARWALL PLAN EDGE NAILING. (TREAT RIM BOARD AS EDGE) SOLID BLOCKING @ 24" O.C. RIM BOARD LAP TOP PLATE A MINIMUM OF 48"

4'-0" TYP.

16d NAILS @ 3" STAGGERED NAILED THRU BLOCKING AND INTO HEADER

SIMPSON MST37 STRAP (TYP) NOTCH SHEATHING AROUND EDGES SHEATHING JOINT

SIMPSON STRAP (TYP.) BLOCKING @ SHEATHING JOINTS USE DOUBLE 2" SILL PLATE w/ 12" ANCHOR BOLTS MIN. 7" EMBEDMENT

WALL SHEATHING PER PLAN JOIST PER PLAN JOIST PER PLAN WALL SHEATHING PER PLAN END TOP PLATE ON STUD

(2) 2x4

STUDS @ 16" O.C.

4"-12" FROM EDGE (TYP.) (MINIMUM OF 2 BOLTS)

SHEET:

S401
8
S401

SHEAR TRANSFER (PERPENDICULAR)

9
S401

SHEAR TRANSFER (PARALLEL)

10
S401

TOP PLATE SPLICE DETAIL

11
S401

NARROW WALL DETAIL

PROJECT ID: SCALE:

Project Number 1/4" = 1'-0"

\\Master_drive\volume_1\Drawings\Drawings2009\Schwinn\Schwinn 2012.3.5 DECK REV.rvt

1/4/2013 6:17:42 PM

Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

Troy & Susan Schwinn

DETAILS

Drawings for:

90 WEST 200 SOUTH, SUITE #1 HEBER CITY, UTAH 84032 Ph. (435) 654-1456 Fx. (800) 375-2156

(2) 10d COMMON NAILS @ 8" O.C. TYP. (2) 2x6 PLY ATTATCHMENT

TRUSS SHALL BE DESIGNED TO BEAR ON BEAM AS SHOWN HEADER WHERE OCCURS

PARK ENGINEERING, LLC

TOP PLATES

No.

NO NAILING REQUIRED AT RIM JOIST

DESIGNER:

GEJ

ENGINEER:

SJP

3/4" T&G WFR. BRD. SHEATHING FLOOR JOISTS PER FRAMING PLANS

Date

STRAP OVER RIDGE BEAM TO EACH RAFTER w/ 20" OF CS18 STRAP


BEARING FOR DOOR OR WINDOW HEADER
Strap per code if top plate is not continuous over header For information on lateral load capacities, refer to current Trus Joist rim board literature.

WEB STIFFENER ATTACHMENT

1 1/2 "

DOUBLE TOP PLATE BLOCKING BETWEEN FLOOR JOISTS

Three 8d (2 1/2 ") box nails, clinched (Three 16d ( 3 1/2 ") box nails at 3 1/2 " TJI joist flange widths) 1 1/2 " W Web stiffener each side. See sizes below. Tight fit W 1 1/2 " 1 3/4 " 2 5/16 " 3 1/2 " WEB STIFFENER SIZE
1/ " 2 5/ " 8

Description

Gap: 1/ " minimum 8 2 3/4 " maximum

VERTICAL REINFORCING FIRE BLOCKING @ WALL MIDHEIGHT (STAGGERED) 2x INTERIOR BEARING WALL 2x TREATED SILL PLATE

x2 x2

5/ " 16 5/ " 16

minimum minimum

5/8" x 10" ANCHOR BOLT (PER SHEAR WALL SCHEDULE) 4" CONC. SLAB

(18" MIN FOR SHEAR WALLS)

SHEATH MAIN ROOF PRIOR TO OVERBUILD (TYP) 2x10 OR SIMILAR NAILERS NAILED w/ (6) 16d NAILS EA. TRUSS OR RAFTER JOIST OR RAFTERS (PER FRAMING PLANS) GRAVEL FILL COMPACTED FILL OR UNDISTURBED EARTH

8" diameter maximum hole for 11 7/ 8 " - 20" joists; 6" diameter maximum for 91/2 " joists or for blocking panels less than 12" long.Do not cut flanges .

Web stiffeners required each side

20"x10" THICKENED SLAB FOOTING

Over Build Framing (30 lbs Snow)


Rafter 2 X 4 DF-L #2 2 X 6 DF-L #2 2 X 8 DF-L #2 2 X 10 DF-L #2 Maximum Span 3 Feet 5 Feet 7 Feet 9 Feet

Twist strap and backer block required with slopes greater than 3" per foot

TJI

rim joist

Trus Joist rim board closure

Must have 1 3/4" minimum joist bearing at ends

Beveled bearing plate required when slope exceeds 1/4 " per foot

All Spans over 9 Feet to be supported at midspan.

1
S402

BEARING WALL TO FOOTING

2
S402

FOUNDATION WALL CORNER

3
S402

ROOF OVERBUILD DETAIL

4
S402

JOIST DETAILS

FLASHING NOTES:
1- LINE-WIRE, WHEN USED AS BACKING TO SUPPORT BUILDING PAPER BENEATH WIRE LATH (NETTING) FOR PORTLAND CEMENT (STUCCO), SHALL BE INSTALLED, AS FOLLOWS: WIRE GAUGE, SPACING AND ATTACHMENT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SPECIFICATIONS. PERIPHERAL FLASHING AT ALL EDGES OF WALL OPENINGS MUST COVER THE WIRE BACKING. NO ATTACHMENT DEVICES NOR THE WIRE BACKING SHALL COVER OR PENETRATE THE FLASHING MATERIAL. 2 - FLASHING TO BE A MINUMUM OF 6" WIDE. 3 - PROVIDE SEALANT AS RECOMMENDED BY WINDOW MANUFACTURER PRIOR TO INSTALLATION OF WINDOW OR SLIDING DOOR.
WALL SHEATHING PER SHEAR PLANS FRAME WALL: 2x6 DF#2 STUDS @ 16" O.C.

STONE VENEER

5/8" ANCHOR BOLT PER FDN PLANS 2x TREATED SILL PLATE

7" MIN. EMBEDMENT

4" CONC. SLAB

STEP 1
LINTEL
4 . 0 0

STEP 2
LINTEL WINDOW

WINDOW ROUGH OPENING SILL


1 "

ROUGH OPENING

FOUND. WALL PER FDN. PLANS

6" MIN.

PRE-MOLDED EXPANSION JOINT FILLER STRIP

8 "

CONTINUOUS FOOTING

ATTACH SILL STRIP WITH TOP EDGE LEVEL WITH, ROUGH SILL, EXTEND BEYOND EDGE OF ROUGH OPENING 8" MIN. SECURE ALL APPROVED FLASHING MATERIAL W/ GALVANIZED NAILS OR POWER-DRIVEN STAPLES.

ATTACH JAMB STRIPS WITH SIDE EDGE EVEN WITH ROUGH JAMB FRAMING, START STRIP 1" BELOW LOWER EDGE OF SILL STRIP AND EXTEND 4" ABOVE LOWER EDGE OF LINTEL.

UNDISTURBED EARTH

6
S402

WALL TO FOUNDATION
Lot 2, Plat 'B', Daniels Gate Sub. 177 East 2060 South Heber, Utah

STEP 3

STEP 4
C
Drawings for:

Troy & Susan Schwinn

B
2 "

INSTALL WINDOW INTO ROUGH OPENING WITH SILL AND JAMB FLANGES OVER PREVIOUSLY INSTALLED FLASHING. ATTACH HEAD FLASHING OVER THE WINDOW FLANGE.

COMMENCING AT THE BOTTOM (SOLE PLATE) OF THE WALL, LAY BUILDING PAPER UNDER SILL STRIP. NOTE: CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND ABOVE THE SILL FLANGE LINE ON EA. SIDE OF THE OPENING (SHOWN AS DASHED LINES). DO NOT SPLICE BUILDING PAPER HORIZONTALLY SO THAT THE PAPER WILL LAP OVER THE JAMB STRIPS. INSTALL SUCCESSIVE LINES OF BUILDING PAPER (B,C,D, ETC.) OVER JAMB AND HEAD FLASHING, LAPPING EA. COURSE.

SHEET:

S402
PROJECT ID: SCALE:

5
S402

NOTES-FLASHING

\\Master_drive\volume_1\Drawings\Drawings2009\Schwinn\Schwinn 2012.3.5 DECK REV.rvt

1/4/2013 6:17:43 PM

DETAILS

Project Number 1/4" = 1'-0"

90 WEST 200 SOUTH, SUITE #1 HEBER CITY, UTAH 84032 Ph. (435) 654-1456 Fx. (800) 375-2156

HORIZONTAL REINFORCING

ROOF BOUNDARY NAILING

2x OVERBUILD RAFTERS

Web stiffeners required each side

INTERMEDIATE BEARING Blocking panels or shear blocking may be specified for joist stability at intermediate supports

PARK ENGINEERING, LLC

CORNER LAP BAR TO MATCH HORIZONTAL REINFORCEMENT (MIN. LAP 3'-0" EACH WAY)

1" x 2 2x4

5/ " 16

minimum

No.

SUPPORT OVERBUILD RIDGE EVERY 6'

Must have 1 3 " minimum joist /4 bearing at ends

DESIGNER:

Trus Joist rim board

GEJ

ENGINEER:

SJP