Professional Documents
Culture Documents
413243
CUSTOMER: SEADRILL
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11409
W.O.NO.
DATE: 03-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
6 7 8 9 10 11 12 13 14
Max Reqd. Min Reqd.
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
03-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11410
W.O.NO.
DATE: 03-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
17
16
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
DAMAGE THREAD
18
SPEC
1.5/8
OK
YES
1.27
19
SPEC
1.5/8
OK
YES
1.27
20
SPEC
1.5/8
OK
YES
1.27
21 22 23 24 25 26 27 28 29
Max Reqd. Min Reqd.
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
13 0 0 1 14
COMMENTS:
03-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11411
W.O.NO.
DATE: 03-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
31
30
SPEC
1.5/8
DAMAGE THREAD
SPEC
1.5/8
OK
YES
1.27
32
SPEC
1.5/8
OK
YES
1.27
33
SPEC
1.5/8
OK
YES
1.27
34
SPEC
1.5/8
OK
YES
1.27
35 36 37 38 39 40 41 42 43
Max Reqd. Min Reqd.
OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
12 0 0 2 14
COMMENTS:
03-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11412
W.O.NO.
DATE: 03-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
45
44
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
46
SPEC
1.5/8
OK
YES
1.27
47
SPEC
1.5/8
OK
YES
1.27
48
SPEC
1.5/8
OK
YES
1.27
49 50 51 52 53 54 55 56 57
Max Reqd. Min Reqd.
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
03-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11413
W.O.NO.
DATE: 03-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
59
58
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
60
SPEC
1.5/8
OK
YES
1.27
61
SPEC
1.5/8
OK
YES
1.27
62
SPEC
1.5/8
OK
YES
1.27
63 64 65 66 67 68 69 70 71
Max Reqd. Min Reqd.
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
03-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11414
W.O.NO.
DATE: 03-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
73
72
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
74
SPEC
1.5/8
OK
YES
1.27
75
SPEC
1.5/8
OK
YES
1.27
76
SPEC
1.5/8
OK
YES
1.27
77 78 79 80 81 82 83 84 85
Max Reqd. Min Reqd.
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
03-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11415
W.O.NO.
DATE: 03-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
182
161
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
103
SPEC
1.5/8
OK
YES
1.27
104
SPEC
1.5/8
OK
YES
1.27
105
SPEC
1.5/8
OK
YES
1.27
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
03-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11416
W.O.NO.
DATE: 04-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
116
115
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
117
SPEC
1.5/8
OK
YES
1.27
118
SPEC
1.5/8
OK
YES
1.27
119
SPEC
1.5/8
OK
YES
1.27
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
04-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11417
W.O.NO.
DATE: 04-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
130
129
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
131
SPEC
1.5/8
OK
YES
1.27
132
SPEC
1.5/8
OK
YES
1.27
133
SPEC
1.5/8
CORRODED THREAD
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
04-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11418
W.O.NO.
DATE: 04-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
144
143
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
145
SPEC
1.5/8
OK
YES
1.27
146
SPEC
1.5/8
OK
YES
1.27
147
SPEC
1.5/8
OK
YES
1.27
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
04-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11419
W.O.NO.
DATE: 05-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
158
157
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
159
SPEC
1.5/8
OK
YES
1.27
160
SPEC
1.5/8
OK
YES
1.27
161
SPEC
1.5/8
OK
YES
1.27
OK OK OK OK
CORRODED THREAD OK OK OK OK YES YES YES YES 1.27 1.27 1.27 1.27
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
05-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11420
W.O.NO.
DATE: 05-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
172
171
SPEC
1.5/8
OK
YES
1.27
SPEC
1.5/8
OK
YES
1.27
173
SPEC
1.5/8
OK
YES
1.27
174
SPEC
1.5/8
OK
YES
1.27
175
SPEC
1.5/8
OK
YES
1.27
OK OK OK OK OK OK OK OK OK
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
14 0 0 0 14
COMMENTS:
05-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
RIG:
P.O.NO.
11421
W.O.NO.
DATE: 05-12-2012
INSPECTION PROGRAM:
ID. NO
DESCRIPTION
Conn. Type
OD
Bevel Dia.
PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
PIN NECK
Dia
Length
Conn. Length
Lead Guage
Tong Space
Cond.
Length (Ft.)
REMARK
185
SPEC
1.5/8
OK
YES
1.27
186
SPEC
1.5/8
OK
YES
1.27
187
SPEC
1.5/8
OK
YES
1.27
188
SPEC
1.5/8
OK
YES
1.27
189
SPEC
1.5/8
OK
YES
1.27
190
SPEC
1.5/8
OK
YES
1.27
SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads
CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads
RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band
LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED
5 0 0 0 5
COMMENTS:
05-12-2012
CUSTOMER SIGNATURE:.. DATE: INSPECTOR:
NNANNA COLUMBUS
ASNT LEVEL II
Member