2 A300
collective
2215 s. ford ave., suite 305 chicago, illinois 60616
2'-0" 9'-9" 9'-5 1/2" 3'-1 3/4" 3'-9 3/4"
41'-8" 13'-6" 12'-2" 5'-10 1/4" 1'-0 1/4" 9'-8 1/2" 28'-2" 11'-2" 7'-0" 2'-9" 4'-0" 13'-6" 12'-2" 4'-0" 4'-6" 5'-10 1/4" 1'-0 1/4"
1054
1055
1056
2'-0"
2'-4"
1053
ELECTRIC METERS TO REMAIN NEW 200 AMP SERVICE TO BE INSTALLED. - SEE ELECTRICAL DRAWINGS ELECTRIC METERS TO REMAIN NEW 200 AMP SERVICE TO BE INSTALLED. - SEE ELECTRICAL DRAWINGS
1057
12" CONCRETE PIERS (TYP.) - SEE A500 4X4 WOOD POSTS (TYP.) - SEE A500
10'-2"
9'-11"
12'-7 1/4"
003 A: 124 sq ft
1052
3'-0"
BREAKFAST ROOM
105 A: 129 sq ft
1058
4'-2"
STORAGE 2
3'-0"
CU-2
CU-1
1051
0015
2'-0"
1059 1044
REAR DECK
1071 1072 x
AIR CONDITIONING CONDENSERS ON CONCRETE PAD @ GRADE - SEE MECH. DRAWINGS NEW WOOD DECK AND STAIR - SEE A500
0051
2'-0"
WASHER
DRYER
MW-1
NEW KITCHEN APPLIANCES AND FIXTURES - SEE PLUMBING DRAWINGS EXPOSED ROUND SPIRAL MECH. DUCT ABOVE SEE MECH. DRAWINGS NEW FURNACE UNITS TO REPLACE EXITING - SEE MECHANICAL DRAWINGS
1061
2A
The Architect and his Consultants do not warrant or guarantee the accuracy and completeness of the work product therein beyond a reasonable diligence. If mistakes, omissions or discrepancies are found to exist within the work product, the Architect shall be promptly notied so that he may have the opportunity to take whatever steps necessary to resolve them. Failure to promptly notify the Architect of such conditions shall absolve the Architect from any responsibility for the consequences of such failure. Actions taken without the knowledge and consent of the Architect, or in contradiction to the Architect's work product or recommendation, shall become the responsibility not of he Architect, but of such parties responsible for taking such actions.
6'-1"
7'-0"
0011
6'-0"
2A
13'-0"
106 A: 108 sq ft
107 A: 109 sq ft
10'-10 1/2"
STORAGE 1
18'-2"
STORAGE 3
004 A: 124 sq ft
KITCHEN
104 A: 327 sq ft
6'-11 1/2"
OVEN-1
2'-2 1/2"
2
3'-9" 1071 4'-5"
18'-10"
FC-2
FC-1
19'-6"
1042
W/D
3A
19'-6"
002 A: 308 sq ft
OVEN-2
10'-3"
005 A: 78 sq ft
2'-3"
PANTRY
BENCH
LAUNDRY ROOM
30'-1"
1043
COOKTOP-1
1072 1062
2A
1'-9"
CLOSET
OFFICE / DEN
6'-0"
3A
EXISTING STAIR
0013
1063
LAUNDRY CLOSET
4'-0"
1'-10 1/2"
MECH ROOM
006 A: 120 sq ft
10'-9"
SHOWER
NEW FURRING FOR PLUMBING LINES AS NECESSARY - SEE PLUMBING DRAWINGS 30" MIN. CLEARANCE FOR TOILET (TYP.) NEW TILE FLOORING IN BATHROOMS (TYP.) SEE FINISH SCHEDULE NEW BATHROOM FIXTURES (TYP.) - SEE PLUMBING DRAWINGS
2A
REF-1
5'-2 1/2"
NEW COUNTERS, UPPER AND LOWER CABINETS NEW TILE FLOOR IN UTILITY ROOMS - SEE FINISH SCHEDULE
6'-5"
1041
2A
1'-0 1/4" 3'-10" 9'-4" 5'-3 1/2"
CORRIDOR 1
111 A: 60 sq ft
4'-0" 4'-7 1/2"
4'-5 3/4"
0014 2'-5"
0014
0012
57'-0"
3A
7'-8 3/4"
57'-0"
3'-8"
WH-1
WH-2
1081
108 A: 58 sq ft
1082
7'-4"
1064
BATH 2
BENCH
WALL-MOUNTED MIRROR
10'-11 1/4"
3'-4 1/2"
SHOWER
3'-7 1/2" 0041
2A
43'-3"
4'-4 1/2"
1032
3'-4 3/4" 9'-2"
0014
12'-11 1/4"
BATH 1
4'-11 1/4"
2A
4'-8 3/4"
5'-6"
3'-7 1/2"
3'-0"
0013
9'-5"
2A
CLOSET
25'-1"
23'-9"
2'-0"
24'-10"
24'-10"
5'-6"
001 A: 513 sq ft
1'-0"
1012 10"
2
8'-2 1/4"
4'-0"
0051 0014
0052
2
0083
3'-0"
SHELVING
11'-10"
SHELVING
6'-2" 3'-2" 5'-9 1/4" 3'-6" 2'-3 1/2"
0012
BEDROOM 1
008 A: 203 sq ft
1029
3'-3 1/2"
23'-9"
MEDIA ROOM
8'-0 3/4"
5'-0"
0053
1031 x
GREAT ROOM
103 A: 225 sq ft
STAIR
112 A: 82 sq ft
13'-11 1/4"
007 A: 100 sq ft
0071
2A
DINING ROOM
109 A: 153 sq ft
1091
43'-3"
5'-2"
5'-2"
3 A300
3 A300
3'-4 3/4"
1091
3A
1081
3 A300
1092
3'-4"
CERTIFICATION OF DRAWINGS
I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED UNDER MY DIRECTION AND TO THE BEST OF MY KNOWLEDGE CONFORM TO THE CITY OF WILMETTE BUILDING CODE AND ORDINANCES.
UP
MEDIA
UP
NEW WOOD FRAMED STAIR WITH FINISHED WOOD TREADS TO MATCH FLOORING - SEE A500
5'-6"
11'-8 3/4"
0082
11'-0"
3'-0"
1028
LIVING ROOM
102 A: 268 sq ft
101 A: 58 sq ft
110 A: 31 sq ft
1101
0011
5'-4 3/4"
4'-0"
0081
GAS FIREPLACE
1011
1102
3'-11 1/2"
1027
2'-0"
2'-3 1/4"
3'-2"
4'-0"
HEARTH EXTENSION
FOYER
COAT CL
GENERAL FLOOR PLAN NOTES: 1. ALL INTERIOR NONBEARING WALLS TO BE TYPE 1, U.N.O. INSULATE FOR
2'-1"
2'-1"
2'-1"
4
4'-4 " 4'-1 1"
1
1026 1025
4'-1 1" 4'-4 "
4'-
" 3/4 /2 01
FRONT PORCH
5 4'" 3/4 0 5'" 1/2
ENTRY DOOR TO BE REPLACED - SEE DOOR SCHEDULE EXISTING FIREPLACE TO BE USED TO VENT NEW DOUBLE GAS FIREPLACE. EXISTING CONCRETE TO REMAIN, REPAIR/ REPLACE AS NECESSARY. EXISTING WOOD COLUMNS - REPAIR AS NEEDED EXISTING CONCRETE STEPS TO REMAIN REPAIR/REPLACE AS NEEDED EXISTING PORCH ROOF ABOVE - REPAIR/ REPLACE AS NEEDED
SOUND AT NEW BEDROOM AND BATHROOM WALLS (TYPICAL) - SEE PLANS FOR LOCATIONS. 2. PROVIDE BLOCKING FOR ALL WALL-MOUNTED CASEWORK AND EQUIPMENT. 3. ALL EXISTING EXTERIOR WALLS TO RECEIVE BLOWN-IN BIOFOAM CLOSEDCELL INSULATION. REPLACE PLASTER WITH DRYWALL AS NEEDED WHEN COMPLETE. 4. REPAIR EXISTING FLOORING AND PASTER/DRYWALL AT ALL WALL REMOVAL LOCATIONS. 5. ALL EXISTING RADIATORS TO BE REMOVED UNLESS NOTED OTHERWISE. PATCH EXISTING FLOOR TO MATCH ADJACENT FLOOR. 6. ALL BEDROOM CLOSETS TO HAVE CLOSET ORGANIZERS PROVIDED BY OWNER AND INSTALLED BY CONTRACTOR. 7. INSTALL MOLD-RESISTANT TILE BACKER BOARD AT ALL TILE AND WET AREAS. 8. PROVIDE PROPER FLASHING AT ALL DOORS AND WINDOWS. 9. ALL EXISTING WINDOWS TO BE REPLACED IN EXISTING OPENING UNLESS NOTED OTHERWISE. WINDOWS SHALL BE INSTALLED WITH MINIMUM AIR LEAKAGE. 12. SEAL ALL PLUMBING, ELECTRICAL, AND OTHER WALL AND FLOOR PENETRATIONS AND SEAL JOINTS. ALL EXTERNAL CRACKS, JOINTS, PENETRATIONS, EDGES, ETC. SHALL BE SEALED WITH CAULKING. INSTALL BITUMINOUS MEMBRANE AT ROOF PENETRATIONS. 13. MEASURES INDICATED IN THE LEED-HOMES THERMAL BYPASS CHECKLIST SHALL BE IMPLEMENTED AS REQUIRED.
"
5'-
1023
6 5 4 3 2 1
02 AUG 2012 16 JUL 2012 11 JUL 2012 03 JUL 2012 26 JUN 2012 04 JUN 2012
ISSUED FOR BUILDING PERMIT ISSUED FOR VILLAGE REVIEW ISSUED FOR CLIENT REVIEW ISSUED FOR CLIENT REVIEW ISSUED FOR CLIENT REVIEW ISSUED FOR CLIENT REVIEW
2'-0"
41'-8"
2 A300
2 A300
14. ALL EXPOSED WOOD SHALL BE 12" MIN. ABOVE SOIL. 15. INSULATION R-VALUE SHALL MEET OR EXCEED REQUIREMENTS LISTED IN CHAPTER 4 OF THE INTERNATIONAL ENERGY CONSERVATION CODE. 16. INSULATE CONCRETE SLAB EDGES WHERE APPLICABLE. 17. INSULATION GAPS AROUND WIRING, ELECTRICAL OUTLETS, ETC. AND INCOMPLETE FILL SHALL AMOUNT TO NO MORE THAN 10% OF THE TOTAL SURFACE AREA COVERED BY INSULATION. GAPS RUNNING CLEAR THROUGH INSULATION SHALL AMOUNT TO NO MORE THAN 2% OF THE TOTAL
2
A100
NORTH
1
A100
NORTH
SURFACE AREA COVERED BY INSULATION. WALL INSULATION SHALL BE ENCLOSED ON ALL 6 SIDES AND IN SUBSTANTIAL CONTACT WITH SHEATHING MATERIAL ON AT LEAST 1 SIDE (INTERIOR OR EXTERIOR) OF CAVITY. 18. NO INVASIVE PLANTS OR LANDSCAPING SHALL BE PLANTED ON SITE.
/ /12008-Proposed3d-120730.pln
A100
2 A300
2 A300
collective
2215 s. ford ave., suite 305 chicago, illinois 60616 312-212-3882 www.collectiveo ce.com
COPYRIGHT Collective O ce, PC. shall retain all copyrights, statutory and common law right with regard to the plans and design content. Reproduction, changes or assignment to any third party shall not occur without obtaining expressed written permission and consent of Collective O ce, PC. LIMITATION OF WARRANTY The Architect and his Consultants do not warrant or guarantee the accuracy and completeness of the work product therein beyond a reasonable diligence. If mistakes, omissions or discrepancies are found to exist within the work product, the Architect shall be promptly notied so that he may have the opportunity to take whatever steps necessary to resolve them. Failure to promptly notify the Architect of such conditions shall absolve the Architect from any responsibility for the consequences of such failure. Actions taken without the knowledge and consent of the Architect, or in contradiction to the Architect's work product or recommendation, shall become the responsibility not of he Architect, but of such parties responsible for taking such actions.
NEW PLUMBING VENT STACK - SEE PLUMBING DRAWINGS
35'-0 3/4" 13'-9 1/2" 4'-2" 3'-6" 3'-6" 5'-2 1/2" 5'-0" 7'-6 1/4" 3'-6" 14'-1 1/4" 3'-6" 4'-2"
2044
2045
2046
2051
2061
2062
2063
3'-8 1/2"
2A
2A
1
4'-4"
3'-6"
2043
3'-8 1/2" 1'-10 1/2"
BATH 3
2051
205 A: 55 sq ft
2053
2064
14'-5"
3'-8 1/2"
5'-10"
204 A: 176 sq ft
2041 2065
26'-2" 11'-7" 3'-5" 5'-9" 2'-6" 5'-4"
2A
3A
2042
SHOWER
2062
2A
2'-5"
11'-10 3/4"
2041
2061
7'-4" 3'-6 1/2"
2A
CORRIDOR 2
207 A: 109 sq ft
36'-10"
3'-0"
3'-5"
WALL-MOUNTED MIRROR 30" MIN. CLEARANCE FOR TOILET (TYP.) NEW FURRING FOR PLUMBING LINES AS NECESSARY - SEE PLUMBING DRAWINGS
2A
34'-4"
2031
2011
3A
CLOSET
CLOSET
7'-4"
2043
2063
206 A: 188 sq ft
14'-5"
2042
BEDROOM 2
2052
BEDROOM 3
2011
1'-0 1/4"
2
9'-3 1/2" 4'-8 1/4"
2A
6'-7"
3 A300
NEW BATHROOM FIXTURES (TYP.) - SEE PLUMBING DRAWINGS NEW TILE FLOORING IN BATHROOMS (TYP.) SEE FINISH SCHEDULE
36'-10"
SHOWER
MASTER BATH
203 A: 114 sq ft
2A
2'-1 1/4"
MASTER BEDROOM
201 A: 232 sq ft
11'-0" 10'-7 1/2" 18'-2"
3 3 A300 A300
3 A300
BENCH
2'-5"
6'-3"
3'-6 1/2"
1'-0 1/4"
11'-5"
2A
2A
CERTIFICATION OF DRAWINGS
2012 I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED UNDER MY DIRECTION AND TO THE BEST OF MY KNOWLEDGE CONFORM TO THE CITY OF WILMETTE BUILDING CODE AND ORDINANCES.
4'-4"
10'-8"
10'-8"
MASTER CLOSET
202 A: 102 sq ft
2021
3'-2 1/4"
2A 1 1
9'-1" 9'-1"
2'-10 1/2"
2'-6"
GENERAL FLOOR PLAN NOTES: 1. ALL INTERIOR NONBEARING WALLS TO BE TYPE 1, U.N.O. INSULATE FOR SOUND AT NEW BEDROOM AND BATHROOM WALLS (TYPICAL) - SEE PLANS FOR LOCATIONS. 2. PROVIDE BLOCKING FOR ALL WALL-MOUNTED CASEWORK AND EQUIPMENT. 3. ALL EXISTING EXTERIOR WALLS TO RECEIVE BLOWN-IN BIOFOAM CLOSED-CELL INSULATION. REPLACE PLASTER WITH DRYWALL AS NEEDED WHEN COMPLETE. 4. REPAIR EXISTING FLOORING AND PASTER/DRYWALL AT ALL WALL REMOVAL LOCATIONS. 5. ALL EXISTING RADIATORS TO BE REMOVED UNLESS NOTED OTHERWISE. PATCH EXISTING FLOOR TO MATCH ADJACENT FLOOR. 6. ALL BEDROOM CLOSETS TO HAVE CLOSET ORGANIZERS PROVIDED BY OWNER AND INSTALLED BY CONTRACTOR. 7. INSTALL MOLD-RESISTANT TILE BACKER BOARD AT ALL TILE AND WET AREAS. 8. PROVIDE PROPER FLASHING AT ALL DOORS AND WINDOWS. 9. ALL EXISTING WINDOWS TO BE REPLACED IN EXISTING OPENING UNLESS NOTED OTHERWISE. WINDOWS SHALL BE INSTALLED WITH MINIMUM AIR LEAKAGE. 12. SEAL ALL PLUMBING, ELECTRICAL, AND OTHER WALL AND FLOOR PENETRATIONS AND SEAL JOINTS. ALL EXTERNAL CRACKS, JOINTS, PENETRATIONS, EDGES, ETC. SHALL BE SEALED WITH CAULKING. INSTALL BITUMINOUS MEMBRANE AT ROOF PENETRATIONS. 13. MEASURES INDICATED IN THE LEED-HOMES THERMAL BYPASS CHECKLIST
6 5 4 3 2 1
02 AUG 2012 16 JUL 2012 11 JUL 2012 03 JUL 2012 26 JUN 2012 04 JUN 2012
ISSUED FOR BUILDING PERMIT ISSUED FOR VILLAGE REVIEW ISSUED FOR CLIENT REVIEW ISSUED FOR CLIENT REVIEW ISSUED FOR CLIENT REVIEW ISSUED FOR CLIENT REVIEW
2 A300
2 A300
SHALL BE IMPLEMENTED AS REQUIRED. 14. ALL EXPOSED WOOD SHALL BE 12" MIN. ABOVE SOIL. 15. INSULATION R-VALUE SHALL MEET OR EXCEED REQUIREMENTS LISTED IN CHAPTER 4 OF THE INTERNATIONAL ENERGY CONSERVATION CODE. 16. INSULATE CONCRETE SLAB EDGES WHERE APPLICABLE. 17. INSULATION GAPS AROUND WIRING, ELECTRICAL OUTLETS, ETC. AND INCOMPLETE FILL SHALL AMOUNT TO NO MORE THAN 10% OF THE TOTAL SURFACE AREA COVERED BY INSULATION. GAPS RUNNING CLEAR THROUGH
2
A101
NORTH
1
A101
NORTH
INSULATION SHALL AMOUNT TO NO MORE THAN 2% OF THE TOTAL SURFACE AREA COVERED BY INSULATION. WALL INSULATION SHALL BE ENCLOSED ON ALL 6 SIDES AND IN SUBSTANTIAL CONTACT WITH SHEATHING MATERIAL ON AT LEAST 1 SIDE (INTERIOR OR EXTERIOR) OF CAVITY. 18. NO INVASIVE PLANTS OR LANDSCAPING SHALL BE PLANTED ON SITE.
/ /12008-Proposed3d-120730.pln
A101